Loading...
T6-81 1 1. • Ordinance No. T6-81 AN ORDINANCE PROVIDING FOR THE MAKING OF A LOCAL IMPROVEMENT IN AND FOR THE CITY OF ELGIN, KANE COUNTY, ILLINOIS BE IT ORDAINED by the Mayor and City Council of the CITY OF ELGIN, Kane County, Illinois: SECTION 1: That a local improvement shall be made in the City of Elgin, Kane County, Illinois, the nature, character, locality and descrip- tion of which improvement is as follows: Installation of an eight (8) inch sanitary sewer in Larkin Avenue between Lyle Avenue and Airlite Street in the City of Elgin. r r • .1 1, SPECIAL CONDITIONS 1.1 BULKHEAD: The Contractor shall install a permanent masonry bulkhead at the poin�of f connection to the existing sanitary sewer. The bulkhead shall not be removed until final acceptance by the City of Elgin. 1.2 TRAFFIC CONTROL: The Contractor shall not obstruct the normal flow of traffic on Larkin Avenue (U.S. Route 20). Flag men shall be provided to insure the orderly movement of traffic when the work is adjacent to the roadway surface and at all times when required by the Illinois Department of Transportation permit. The cost of providing traffic control shall be considered incidental to the cost of the work. The Contractor shall also be responsible for signing and maintaining detours when intersecting streets are closed. 47) I I f I I I SC-1 01 • , • • ' I (eft DETAILED SPECIFICATIONS GENERAL The Detailed Specifications of material and labor required for the construction of the Larkin Avenue Sanitary Sewer for the Board of Local Improvements of the City of Elgin, Illinois are contained herein. These Specifications accompany the Plans prepared by: EVERETT SCHEFLOW ENGINEERS A Professional Corporation 1814 Grandstand Place Elgin, Illinois 60120 Said Plans include Sheets 1 through 4. . The Plans and Specifications are intended to be complementary and provide for a completed project, in accordance with the obvious or expressed intent of the Contract. The General Conditions are part of these Detailed Specifications and the Contractor shall consult them for instructions pertaining to work under the various headings. l I I I I DS-1 t SECTION 1 STANDARD SPECIFICATIONS 4' The following Standard Specifications shall govern the construction . of this project to the extent that they are specifically incorporated by reference herein and except as modified herein or as modified by applicable laws, ordinances or regulations. a) Standard Specifications for Water and Sewer Main Construc- tion in Illinois, Third Edition, dated September, 1978 (Standard Specifications) - Divisions II and III. SECTION 2 STANDARD DETAILS The following Standard Details shall be used. Where information shown on these details is in conflict with the Specifications or with details included on the Plans, these Standard Details shall govern. The Standard Details are included in these Specifications. Standard Drawing No. 1 - Typical Detail of Conduit Installation . Standard Drawing No. 2 - Payment Quantities per Foot of Conduit Standard No. 1001 - Manhole - Type A Standard No. 1002 - Sanitary Sewer - Drop Manhole Standard No. 1004 - Sanitary Service Standard No. 1005 - Sanitary Service - Riser SECTION 3 PAY ITEMS 3.1 SANITARY SEWER COMPLETE IN PLACE: Payment for sanitary sewer complete in place shall be per lineal foot and include all excavation necessary, granular cradle, pipe, select granular backfill to 1 foot above the pipe (Case II backfill), backfill , trench compaction and all surf restoration not paid for specifically as a pay item. Pipe material shall be vitrified clay pipe (VCP) in accordance with paragraph 30-3.01 C, polyvinyl chloride (PVC) sewer pipe in accordance with paragraph 30-3.02 I or acrylonitrile-butadiene-styrene (ABS) sewer pipe (including "Truss Pipe") in accordance with paragraph 30-3.01 J. Joint material shall be as recommended by the manufacturer except that VCP pipe shall be of "no bell" construction. 3.2 MANHOLES: Manholes shall be paid lump sum for each 48" diameter by 8 feet deep manhole complete in place with a unit price per vertical foot for manhole height in excess of 8 feet. 11 3.3 DROP MANHOLE CONNECTIONS: Drop manhole connections shall be paid for per each connection. 3.4 CASING PIPE: Casing pipe shall be paid for per lineal foot of pipe of the diameter shown on the plans jacked and augered complete in place including pits, select granular fill , restoration, etc. 3.5 SELECTED GRANULAR BACKFILL: Selected granular backfill shall be provided where shown on the plans or ordered by the Engineer. The type shall be as determined by the Engineer. Measurement shall be as provided in Standard Drawings 1 and 2. Payment shall be per cubic yard complete in place including disposal of excess excavated material. 111 DS-2 • • • 3.6 BITUMINOUS SURFACE REMOVAL AND REPLACEMENT: Bituminous surface removal and replacement where shown on the plans or ordered by the Engineer shall be paid for per square yard of surface removed and replaced. The measurement for payment purposes shall be in accordance with Table 1 shown on Standard Drawing No. 2. All joints shall be saw rft cut prior to replacing the surface. The minimum compacted thickness of the bituminous concrete shall be 2". 3.7 P.C. CONCRETE SURFACE REMOVAL AND REPLACEMENT: P.C. concrete surface removal and replacement where shown on the plans or ordered by the Engineer shall be paid for per square yard of surface removed and replaced. The measurement for payment purposes shall be in accordance with Table 1 shown on Standard Drawing No. 2. All joints shall be saw cut prior to replacing the surface. 3.8 WYE FITTINGS: Wye fittings shall be provided and installed complete with stopper where shown on the plans or ordered by the Engineer. Payment shall be per wye fitting installed. The Contractor shall keep a record of the location of all wye fittings installed. 3.9 SEWER SERVICE RISER PIPE: Sewer service riser pipe shall be provided and installed complete with stopper in accordance with the detail where shown on the plans or ordered by the Engineer. Payment shall be per vertical feet of riser pipe installed. 3.10 SEWER SERVICE PIPE: Sewer service pipe shall be installed where shown on the plans or where ordered by the Engineer complete with stopper and shall be paid per lineal foot of pipe installed. SECTION 4 DIVISION II EXCAVATION AND CLEANUP 4.1 GENERAL: Certain notes appear on the plans that modify or clarify the Detailed Specifications. These notes where in conflict with the Detailed Specifications or Modification to Detailed Specifica- tions shall govern. 4.2 PARAGRAPH 20-2.08A - BRACED AND SHEETED TRENCHES - GENERAL: The Contractor's attention is directed specifically to the requirement that tight sheeting is required along State Highways under certain conditions. All sheeting used shall be pulled. Select granular backfill shall be placed before sheeting is pulled where required. 4.3 PARAGRAPH 20-2.19 - UNDERGROUND CONDUIT CONSTRUCTED IN TUNNEL: The following paragraphs shall be added to the applicable sub-paragraph. Where they are in conflict they shall govern. STEEL CASING PIPE IN PLACE: Where shown on the plans the Contractor shall construct casing pipe below ground surfaces by augering and jacking as herein specified. DS-3 r • Casing pipe jacked in place shall be welded steel pipe, in accordance with ASTM Designation A 139 Grade B and a minimum yield of 35,000 psi. The casing pipe shall have a minimum wall thickness as shown on the plans. Each jacking shaft shall be completely sheeted to provide proper support for the bank and adequate support for reaction blocks. The shaft shall be constructed long enough to provide room for jacking head, frame, reaction blocks and a minimum of 15 feet of casing pipe. The width shall be sufficient to allow ample working room. The backstops or reaction blocks shall be placed absolutely perpendicular in all directions to the axis of the pipe and the guides carefully installed to the proper line and grade. Jacking pressure must be applied by a pushing frame at right angles to the line to avoid forcing the casing pipe out of alignment. The first section of casing pipe shall be equipped with a steel cutting shield placed over the upper one-third of its circumference and securely fastened to the pipe. The casing pipe shall be installed using equipment that encases the excavated hole as earth is removed. Excavation and/or boring without the concurrent installation of the casing pipe will not be permitted. All joints in the casing pipe shall be continuously welded. The jacking operation shall be continuous insofar as possible to prevent seizure of the casing pipe. The Contractor shall excavate and dispose of material of any nature required to carry out the work. Shaft excavation shall be in accordance with applicable paragraphs of the Specifications. All 4!) excavated material from shaft and casing pipe placement shall be promptly removed and disposed of. Upon completion of casing pipe placement and after the sanitary sewer carrier pipe is installed within the casing the shaft shall be filled with selected granular backfill . The cost of said backfill shall be considered incidental to the cost of the contract and no additional compensation will be allowed. After the casing pipe is in place the Contractor shall install the sanitary sewer carrier pipe, of the size and material specified, within the casing pipe and to the line and grade established by the Engineer. When treading of the carrier pipe is complete and approved by the Engineer, the Contractor shall fill the voids between the inner wall-of the casing pipe and the outer wall of the carrier pipe with sand. The ends of the casing pipe shall then be sealed by placement of a minimum of ten (10) inches of concrete, or in some other manner approved by the Engineer. The Contractor shall furnish, install and maintain all facilities for collecting, conveying, and displacing of ground and/or surface waters within or around the shaft excavation until the completion of the work. The Contractor shall have on hand at all times sufficient machinery for all emergencies that are likely to arise on work of this character and such machinery shall be kept in good working order. The pumping and power supply to the pumps, etc. , shall be under the direct charge of competent mechanics. DS-4 I • 4.4 PARAGRAPH 20-2.21 BACKFILL: The plans show where selected granular fill is required. Selected granular fill shall be type A, B, C or D as specified in the Specifications or as determined during construction. Where selected granular fill is not required excavated material may be used for backfill if suitable. All backfill not requiring mechanical tamping shall be jetted. The Contractor shall make arrangements for the purchase of water for jetting from the City of Elgin and pay all costs. 4.5 PARAGRAPH 21-2.01 TEMPORARY SURFACE OVER TRENCH: Temporary surfaces for driveways shall be provided as soon as the trench is backfilled. This work shall be incidental. SECTION 5 SANITARY SEWERS AND STORM DRAINS 5.1 GENERAL: Certain notes appear on the plans that modify or clarify the Detailed Specifications. These notes where in conflict with the Detailed Specifications or Modifications to Detailed Specifica- tions shall govern. 5.2 PARAGRAPH 31-1.02 PIPE LAYING: All pipe shall be laid utilizing a laser device for controlling line and grade. 5.3 PARAGRAPH 31-1.11 TESTING FOR ACCEPTANCE OF SANITARY SEWERS: Testing shall be by lamping and the air test method. If flexible thermoplastic pipe is used deflection testing is required. Prior to testing the Contractor shall thoroughly clean the pipe using a cleaning ball or other approved method. 5.4 SECTION 32 MANHOLES: Manholes shall be in accordance with the details attached to these Specifications. r l I I I I DS-5 I AI'PLCATION FOR PAYMENT NO. 1 t (OWN Contract for Dated OWNER'S Project No ENGINEER'S hoject No. For Wort oaaomololmd through the date of r" CIDW ACTOR.fad.l M Yaw. Won C.eM+.� Ur later Pawl Ari Ornate)- Ammo • I I t f I I I I I Accompanyinf Documentation: GROSS AMOUNT DUE S_ _ LESS 4.RETAINAGE S AMOUNT DUE TO DATE S_ LESS PREVIOUS PAYMENTS S AMOUNT DUE THIS APPLICATION S CONTRACTOR's Ccn Meat ion: • The undersifned CONTRACTOR cenifet that(I)all presious prnftesi pa'ments'revised(tom OWNER or a:count of v cr1 done under the Contractt refuted to abort hs+e been applied to dischatje in full all oblications of CONTRACTOR incurred in connection with Work cosered by prior Applications for Payment numbered I lhrouch inclusise;and(2)title to al! materials and equipment incorporated in said Wort or otherwise listed in or cosered by this Application for Payment will pass to OWNER at time of payment free and clear of all liens,claims,security interests and encumbrances(except such as cos erect b) • Bond acceptable to OWNER). • Dated • 19- COI.TRACIOR • By ENGINEER'S Recommendation: This Application(with aceotnpanyinl documentation)meets the requirements of the Contract Documents and payment of the above AMOUNT DUE THIS APPLICATION is recommended. • (IL fief-n;anenf o s v t onan74 'ewe%/ % rt,/resineef for ,oy,n9 f.../•ses E•/si Lentrefs • V Eliot. LL`.i1 �Crelr,e�f�partwotp+y er boat O` �tOis• L p/ic ./1 I �_• • . • ♦ • ►.• ••4 ! •• =_�"`' =. At1 toiJti[?‘s- •.'►. - • A. �. . 01 ► . ''•. • ► •. . ► • • • • ••/:o • • . •• • �Lo" • _ wi ■ p [ v Oay`.s.iie• %Mee bit, d lit OP' Box *4 `y i1 ` so •% 44,,V i A V ICI a v 11 .4113 i 4 . • • • . . I�►- ,,,o rips,...,, TrencA }' .e • ti b w:/f!, .f Trop .f eondl.;1` .. 4 i ' k - a dies Sect ?O-Z.03 j t • �' 0 ; v I ti■: ate: t ! • ...4 `a1 s iv Lo/av/OXOn bored •:F1't. i Chore! Gr.dis : c • '� + t 14,4:" I Li." t. far t14Oril:pff fa. peyesene CI'.d/e ('O-Z.Z ~ pkrpvse, ore es shs...n, see isA/e A'.. •I set s7aiw/i,e •%...►:�.s 0y. 2 any 91/42 re ■ •reveal:On dkegend TYPICAL DETAIL Mess /%pls;t. /rift iv iOC+417/esl w;th a./e4.1 fron../o.- bock{,•/I of OF CONDUIT 1be dispense .l Mt .on>'.roeta. INSTALLATION •irk - nil,. V/STANDARD DRAWING NO.�' PAGE: 129 X L -: • - , . . k . 4.:...-..--._-..-.--,.------.....-.,...........--,.-----___--.......,, 1 74901. E .I t A9 y/44f Air 40 vo P/vr/Tie 5 .°4 POT comps",r V I..e. • I ii 1111 k • A j k .', I i S 1■ *el 4 J., 1 k I ••2 1 It■ Os l.) %4.% N'‘ t=! tt . Z 'ktt tv 4 IgiWK" Vt .Z■ 4 % t I \ *44, k 11 i. 1Z) C " I ‘‘: %.4.1 %) gi'L'. Et ; k • % t't 4 oii 1 .%\3 0 0 Nr; v,b 1/4 . , k . .4.ktti ■ VE '4: % Ell ilv: 0 . . k II V v I is. c k 14 40. 1 (‘11% k;k tiN . 4 \ - 4 ' t 0 l‘\ 0 e. si 4 4 • i tttk c l!.xt k! c; 4 x, : 1 kN: t ft Z I ■ 11i 1. 11) 61 '•■ 1 V q 94%. i ■ tz IL tv , Vort, a 414 , E x . 11,, ■ ; % 49)" t1/4) ICNEi■ORV'ell ‘J141:61ZI it01/41 4;.1/44, • v. - '. I.”7 O. - 0 7 5/7 5./7 c -4 0./5 1 Min- in nriliiIIIMMI - 0 11/7GFA ilrar211- I ,. - wait Irma IMF/11MM=MIMI NEM= o - 1111P711111 VIM VIM,MEM -11/272111r3r7311111101711111.11P-7111M17:111: I /5" 3;-L. 4/3 01-z 0 a/ ts"So .57So 0.06 0-Z /8 5:-/o- .0/4 DAC 0.6S S.1 is .s:pi.r a 07 022 2/ 4‘ •41 0./6 0.19 4a 70 1 ' 33 4.33 008 0.27 i t 2 " fe.-ir- 42./7 i:7.2/ D.74. I _0.47 047 0.09 0,3,7 27 44tf/.. ..0./..- .0. 0 0.9 0. - -.09.09 #. 1 WOOL InifirTa 11 IM EMI IIMIC7111 1111F71711 . - - OrnINI inn, =ram ,,,,c, . WWI IreMil o 1111%111111111n_00 , MIMS I 11171111111M12111112F71111M211rn_,__- - 111717311 48 %alai infra Ira°33111111104311 Mr-/_MM- -111r7- 231111100MMI ! 4.11i a 3z 0/L 0,75 114111011 , w PAIIKIIMPAI .44 . i EllIFIESP151„„„„..° 7e 1%111MINI e'..//e- I 47.1/2 • 111711111111MER c. o w*,...ktal FATE 119=1111172711 .zo I - • ac REM NMI o. - - 0 FX1711111077-111MMI OMNI -Q MilgalranIri WWII 111017111 11,2SrT1 17772 111-117‘111/7411111 f 56 J2 -8 4o.47 l./1- / 3 /447 /4. 7 023 /34 /02 hr:-3' 0.45 /Z4 /49 /s.LS 4-. z 5 a z 5' /98 /Pe /-i"le- 047 132 /.7 7.47 E3 J.S.R3 0.Z /-„re I No TES• I ...■■=1 • s PAYMENT QUANTITIES PER FOOT L-......-...:,:,,:,..:,..- :"- ;;;___ OF CONDUIT PAYMENT..,_.../........................MA r..1 te• V:STANZ:ARD C4W.V:itit3 n 0.2 .doi -. 1-A.2E : 130- - -. .. .... . . . - - • - --'. ". * - • . , --• - - . . . .. . . . . t. , ...-, .: • . . . . .. . •. . . .. - .. . . . _. ._ ... „ , _ -* ,--,--------i- "--rWi: er:••••wer,•-aZt•a-ei.:JR. A.*.•a.•Tire....t ...- . • . "2•_t10....dlii'.:ae7'.'Z.:d.:111714 .. ft,"77:11:1'11." .,...;i .....tilf2r:jr.•-•,.:7*!'..4:.r..:.a, ......,...•..,.... . . . . • • . . . MANHOLE - TYPE A • STANDARD NO. 1 001 BID PRICE FOR MANHOLE SHALL INCLUDE FURNISHING AND PLACING CAST IRON FRAME AND LID TO FINISHED GRADE OF EXISTING PAVEMENT, EXISTING GROUND SURFACE OR FINISHED GRADE AS ESTABLISHED BY THE ENGINEER. MATERIALS: FRAME AND LID EQUAL TO NEENAH FOUNDRY CO. CATALOG • MOS • NO. R-1031 WITH TYPE B LID - 1" CONCEALED Iowa ,...7..... PICK HOLE AND THE WORD "SEWER" CAST IN LID. WALLS PRECAST REINFORCED CONCRETE RISER UNITS. '' � MINIMUM THICKNESS C./,. ' .. 5" FOR 4' INSIDE DIAMETER •s K.o.c. 6" FOR 5' INSIDE DIAMETER • RISER JOINTS • •��:o. of/re ROUND RUBBER GASKET OR PREMOLDED n_ 1' BITUMINOUS JOINT COMPOUND - CEMENT MORTAR PLASTER COAT TO BE APPLIED ON INTERIOR AND EXTERIOR AT ALL RISER ' • JOINTS AND MANHOLE STEPS. FRAME ;.•.. 0 TO BE SET TO FINISHED GRADE IN CEMENT f• • •;, t MORTAR. , BOTTOM ••• PRECAST REINFORCED AND CAST INTEGRAL ~ WITH FIRST VERTICAL SECTION. '.,. ...:!:...1 • sL.721 SANITARY MANHOLES ".' �• ALL INLET AND OUTLET PIPES, SHALL BE � �'•t �'�''' CAST INTEGRAL WITH FIRST VERTICAL �.... , • -.1:'•..'.. . • . ..• . j� SECTION. ALL PIPES SHALL EXTEND A `' .' '` �,NNO 0445,0//off MINIMUM OF 12" OUTSIDE PRECAST SECTION•�'' '� `'� e•/1//N. OR AN APPROVED FACTORY FABRICATED FLEXIBLE I SECTION A-A MANHOLE SLEEVE CAST IN THE MANHOLE. INSIDE DIAMETER 4'-0" FOR 18" MAIN SEWER AND UNDER A 5'-0" FOR 21" TO 42" MAIN SEWER BOTH INCLUSIVE. xoPE- TIP E vavi y :` FOR SHALLOW MANHOLE OR WHEN REQUIRED AI ; A PRECAST REINFORCED CONCRETE FLAT I ' SLAB TOP MAY BE USED. REFER TO • G `/ STANDARD NO. 1003. 1 rk \ *.. atoPrc Ia¢.,^/ A I SECTIONAL PLAN SEPTEMBER 1980 . . . . 1 s SANITARY SEWER , 0 [DROP MANHOLE CONNECTION DETAIL I STANDARD RD NO. 1002 I A DROP MANHOLE SHALL BE CONSTRUCTED WHEN THE INVERT OF THE INFLUENT SEWER IS 2.0 FEET OR MORE ABOVE THE OUTLET OR MAIN I _ SEWER INVERT. MUM 3" -:; ,R ABOV 11s4h f ! LBNCH EL OF !..: MORTAR DAM IN INVERT • II .. '• R_ii '11 INCOMING SE!JER SMALLER THAN 12" USE •I :. _ VERTICAL PIPE OF SAME DIAMETER. FOR INCOMING SEWER 12" OR GREATER, USE 12" ;'. VERTICAL PIPE. a A!) :Ili r . • bc • . . . • . - ---_J.I a: IIii •! 0 •:•• •.'.:..•.:••:a.:f.• I SECTION A-A MINIMUM 6" ! I CLEAR OF I 1 BELL 1 .. •' . DROP MANHOLES SHALL BE CONSTRUCTED IN A • L .. A ACCORDANCE WITH APPLICABLE PARTS AND '/��"'• SPECIFICATIONS• REFERTO STANDARD NO.MANHOLE NO. 1001•TYPE A. 1 '. :•' 1 I / 1 SECTIONAL PLAN SEPTEMBER 1980 . . SANITARY SERVICE r STANDARD NO. /004 NOTE: 1 SERVICE PIPE SHALL SE OF TSE TYPE SPECIFIED AND/OR ALLOWED BY THE MUNICIPALITY. IF DISSIMILAR FROM MAIN LIE SEWER, • MANUFACTURED ,. ADAPTOR OR ADAPTOR FITTING SHALL SE USED. IF MANUFACTURED r1Q ADAPTOR IS NOT AVAILABLE, METHOD AND KANNEER OF CONNECTION �a k OR JOINTING SHALL SE APPROVED BY THE ENGINEER IN WRITING PRIOR TO C NSTEUCTION. Q Ir .� li I 0 STANDARD VYZ BRANCH AND 45 0 SEND OR I STANDARD TEE NITH 450 BEND, IF APPROVED. C BRANCH SIZE AS INDICATED ON PLAN OR AS • SPECIFIED. r..1 r 4 it, END PIPE OP SERVICE LINE SHALL RAVE A WATERTIGHT STOPPER SECURED IN PLACE AND BLOCY.ED. I / �� I , . : ‹ rG . 00-' c 4 PLAN r/N/MLA�K/MI $LOP( �co+i , ...t., /"M-16)10111111111111111111111 . . . . .. ....acc• ir - • , .,'. :.:':p - °.:.fir..,.':^. .. SECTION A•A MINIMUM 4" APPROVED, COMPACTED GRANULAR BEDDING AND BACIoILL TO SPRING LIME OF SERVICE LINE. I , SANITARY SERVICE - RISER I STANDARD A /005 I woTE: RISERS SHALL BE CONSTRUCTED WHERE MAIN LI1Z SEWER INVERT IS 10'•0" OR MORE BELOW THE GROUND SURFACE. 1 111111 T. kg [ � . Lh, i. .� k Iits I . I b .I Ill —I ii PLAN E �i I Z,`a IiW• r • i 6 4: k 4100 _NNW . II III *.■ .. .. r .. kI 4 MA7XII4JM SLOPE 1:1 C _. =mum 4" APPROVED COMPACTED 1 I i GRANULAR BEDDING TO EXTEND TO % to .0--SSPRING LINE OF PIPE. ;Z o t ' ,:-. ::`., STANDARD ZEE' - ERANCH SIZE AS INDICATED Z a -,:..\\. ON THE PLAN OR AS SPECIFIED. t SV ::,;..., .. ox ill . _SECTION A-A al e"' POURED CONCRETE ENCASEMENT, SHALL EXTEND TO UNDISTURBED VERTICAL WALL OF TRENCH • EACH SIDE. VOTE: END PIPE OF SERVICE LINE TO HAYS WATERTIGHT STOPPER SECURED IN PLACE AND BLOCKED. -1�r I♦ - !-: 4-� _ r.�':i��- d-. CR`IV SOIL AND MATERIAL CONSULTANTS, INC. C ' ` J •WEST COLLEGE DRIVE • ARLINGTON HEIGHTS,ILLINOIS BOOO4 • 31247x-0544 March 31, 1981 File No. 6447 •lift Everett Scheflow Engineers 1814 Grandstand Place Elgin, IL 60120 Attn: Mr. Everett Scheflow APR 2 1981 RE: Larkin Avenue Sanitary Sewer Dear Mr. Scheflow: We are submitting the results of our subsurface soil investigation completed for the proposed sanitary sewer improvements along Larkin Avenue between Lyle Avenue and Airlite Street in the City of Elgin, Illinois. For this investigation a total of five borings were drilled at the locations and to the depths indicated by your office. We are enclosing copies of the boring logs, summary of test results and location sketch. At the location of borings 1 thru 4, topsoil and topsoil mixed with silt is indicated in the upper soil layers. The underlying soils are found to be predominantly granular soils consisting of silt and fine sand mixed with lesser portions of clay and gravel. Occasional layers of predominantly clay soils are encountered at borings 1 and 2. The test results indicate that the upper portions of the underlying soils are found to be high in moisture content. Reduced moisture contents are indicated at the deeper elevations, except in the area of boring 3, where high moisture content is recorded in the brown-gray clay layer between 6.0 feet and 9.5 feet. No measurable ground water was encountered at the location of borings 1, 4 , and 5. At borings 2 and 3 high water level readings of 3.0 feet and 12.5 feet were recorded respectively. Further, at the location of boring 3, a saturated layer of sand is encountered between 4.0 feet and 6.0 feet. Meas- urable water seepage from this layer was not recorded. The enclosed boring logs indicate the elevation of the proposed sanitary sewer. As can be seen, sand and silt soils are generally encountered at this elevation. Excavations to this depth will remove confining pressures on the embankment soils. These soils are anticipated to become unstable when pressures are removed. Adequate protection should be provided in the work area against slope instability. Shallow excavations of less than 5.0 II Irk I ENGINEERING • TESTING • INSPECTION • OUALITY CONTROL r . • v i Everett Scheflow Engineers March 31, 1981 RE: Larkin Avenue Sanitary Sewer File No. 6447 Page 2 • feet may be sloped in order to prevent embankment failure. At the deeper 1 elevations it is anticipated that vertical cuts will be made requiring a steel box to protect the working area. In particular, those areas where saturated soil layers are encountered are anticipated to provide the great- est amount of instability at the earliest time. Were silt and fine sands are encountered at the bedding elevation and high moisture is present it is probable that these soils will become unstable. The result is a loosening or fluffing of these soils. If instability is observed, a bedding of 8.0 inches to 10.0 inches of crushed granular material should be provided to establish a stable working surface. The soils indicated at borings 4 and 5 are fine grain soils consisting of sand and silt. Little or no trace of cobbles and boulders was observed at the locations drilled. The augering or jacking operation under Larkin Avenue ` should encounter few or no obstructions. The 16.0 inch diameter steel casing already planned to protect the sanitary pipe is necessary to prevent cave-in in the augered shaft. 47)` After you have reviewed the enclosed information we would be pleased to dis- cuss any questions which you may have. If we may be of further assistance, please let us know. IVery truly yours, SOIL AND MATERIAL CONSULTANTS, INC. Gerald J. Kissner, P.E. President CJK:ek Enc. I I / SOIL BORING LOC tIrli SOIL AND MATERIAL CONSULTANTS. INC. N WEST COLLEGE OWE • ARLINGTON MESKTS.WNOIS 101O4 BORING NO: 1_ 1 CLIENT: EVERETT SCHEFLO'W ENGINEERS LOCATION SITE: Larkin Avenue - Sanitary Sewer • Elgin, I1 VSCONFINED COMPRESSION TEST, Strength �� (tons/sq.ft.) 1_%%111-1A- 1....1 LPr1.No. 6447 Dates 3/27/81 Bv:_.�! 2�� a Equipt. Used: CHI Drill a . }r+Q ;J2 P P o - g Comments: 21444 PENETROMETER READING WATER CONTENT, T- DESCRIPTION OF MATERIAL to 4 /�� " u — - —)( — — — -- -�- - a a , c A° TANDARD "N" PENETRATION (blows/ft.) 11 4 Existing Surface - Elev. ft: 832.5 :)'" 10 20 0 40 0 Black topsoil, some silt, damp - (24.0") IIIBrown clay, some silt, trace sand and '98,3 , 0 i IN iravel. damp, tough f , Brown sand, some silt , 'damp, medium ,` dense L.� Brown silt, some fine sand, very damp, _ /fix medium dense ) 0 n Town silt, some fine sand, very damp, loll Jense Q v i JC End of Boring II t 'j I al 1 . i 1 _ _:_ I iai Ir II _ 'titer Encountered At none During Drilling Operations Page No.1 of 1 'Water T..v.1 ! _. _ Hours After Completion Of Boring • SOIL BORING LOG 1041 SOIL AND MATERIAL CONSULTANTS. INC./ •WEST COLLEGE OIWE • NIUNGTON Mt3GMMTL.(LPIOIS 10001 2 BORING NO: CLIENT: EVERETT SCREFLOW ENGINEERS LOCATION SITE: Larkin Avenue - Sanitary Sever Elgin, 11 OBCONFINED CQiPRESSIOIi TEST a7.(t Strength :f7 Pro 110 6447 t 3 27 81 ona/aq,ft•) Equipt. Used: OfE Drill Q �.Q 4,0 : Comments: w PENETRQSETER READING j MATER CONTENT, ec oc t. • DESCRIPTION OF MATERIAL c • • e.a ANIVRD ~N" PENETRATION (bless/ft,) a' Existing Surface Elev. ft; • 0 , D 0 0 0 40 Black topsoil, damp, soft - (48.d) 7i•$� Brown silt, some clay, trace sand and gravel, damp, tough 1_) lit* • Gray silt, some clay and gravel, trace .0 sand, damp, very tough End of Boring ` I er Encountered At 5.0' During Drilling Operations Page No.1 of 1 lat.♦ T....1 1.0' • U... Aft.. . +nn f1f Wnwf•►e SOIL DOLING LOG % SOIL AND MATERIAL CONSULTANTS. INC. • II%TEST COLLEGE OWE • All JNGTON NBM1TS.LOOS 1000 I soli= NO: 3 CLIENT: EVERETT SCHEFLOW ENGINEERS LOCATION SITE Larkin Avenue - Sanitary Sewer 1 Elgin, I1 UNCONFINED COMPRESSION TEST, Strength (tons/sq.ft.) I M ---1.110.6447 Dat e: 3/W-e.. sv: 11:e I Equipt. Used: ME Drill a _ '� Comments: PENETROMETER READING W1TER CON!'ENT, %- DESCRIPTION OP MATERIAL p BSI4. a 'IrSTANDARD "N" PENETRATION (blows/ft.) ' II 4 Existin: Surface - lee • 841.5 110 0 10 40 I Brown sand and ravel dam. 11111 Black topsoil, some clay, damp, tough /ej ` IBrown sand, some silt, trace gravel, • III saturated medium dense ram Brown-gray clay, some silt, trace sand col,? 0 N and gravel, damp, tough Brown silt, some sand, trace gravel, 0 damp, medium dense 1/111 Gray silt, some fine sand, trace clay - �_ and gravel, dense IL • an Ind of Boring 1. I . a . r . _______. . ___ -- . _____ i . la . I - ■ l . L - I 1 III ter Encountered At 12.5' During Drilling Operations Page No.1 of 1 • • I �• SOIL BORING LOC �V',,� SOIL AND MATERIAL CONtULTANTA MIC � •WEST COLLEGE OWE • MASONS NNW&LINOS IoODr 11 BORING OD: 4 4 CLIENT: EVERETT SCREFLOH ENGINEERS LOCATION SITE:j,arkin Avenue - Sanitary Sewer Elgin, 11 UNCONFINED COMPRESSION TEST, Strength (tons/sq.ft.) E Pso 1 110 6447 Date: 3/27/81 fv: , e _Equipt. Used: CIME Drill i"s Y aevm Comments: �� PENETROMETER READING YATER CONTENT sic • • oESCRIPiION or MATERIAL — --- '�'—� — — — — ———Q— — — 6 E � c �STANDIIRD "N" PENETRATION (blows/ft.) 6, ' • isti Surface - Elev. ft: 864.0 0 0 0 • 40 fyr �� Brown sand, some silt, trace gravel, damp, loose 1JE ■■ I,II Brown fine sand, some silt, trace clay, _A_11III re5 damp to very damp, medium dense i' End of Boring 'LA (a) Black topsoil, damp - 3.0" N j 2 i1111 _AI NS a ■/ sr/ is ter Encountered At none During Drilling Operations Page No.1 al ater Tivol a Tine £fr.r rew,,l.ftnr, of Rnrine SOIL BORING LOG tt SOIL AND NATIONAL CONSULTANTS. INC. WEST COLLEGE DONE • MIUMCTOM MBGKTS.LLP OIS GM BORING M0: s CLIENT: ERETT SCREFLOW ENGINEERS LOCATION SITE:, Larkin Avenue - Sanitary Sewer r Elgin, I1 UNCONFINED COMPRESSION TLST, Strength Aral' ;41____G____�(tona/sq.ft.: j Pro1.No. 6447 Date: 3/21/81 Bv: #� t a s, Equipt. Used: C1� Dril �4 U Comments: �w PENETROMETER READING iUTER CONTENT e a DESCRIPTION OF MATERIAL c 4 _ _ _ _ — — —tit C TANDARD "N" PENETRATION (blows/ft.) 14450f Existing Surface - Ele ft: 862.0 , Dom! v 10 0 30 40 0 t_ (a) see below A 1 Brown sand, some silt, trace gravel, , xe\ _ damp, loose 1:1:: IBrown fine sand, some silt, trace gravel, AT ')(. .A. damp, medium dense ■ Fr 1 End of Boring 1 lir (a) Brown silt, some clay, trace sand and gravel, damp, tough 'rpm I it— I-, • sJ , iT` 1 ater Encountered At none During Drilling Operations Page No. 1 of 1 ■ �1wtwr ♦....1 Nnitr• aft*. PA.....l.r.nn of RnTteme ■ EVERETT SCHEFLOW ENGINEERS March 27, 1981 EE: Larkin Avenue - Sanitary Sewer File No. 6447 Elgin. I1 1[ 410 II AM= QE MDORATQtj MI UNCONFINED IFBORING SAMPLE DEPTH PERCENT UNIT MEIGET COMPRESSIVE STUNG= M0. M0. TT. MOISTURE (lba./eu.ft.) (tone/eq.ft.) i 1 1 1.5 26.7 II 1 2 2.5 27.7 98.3 1.8 II1 3 6.0 9.9 1 4 7.5 13.1 1 5 12.0 10.4 2 1 2.5 24.2 76.8 0.4 2 2 2 5.0 16.0 3 7.5 10.8 111.2 2.4 3 1 2.5 14.3 105.6 1.1 3 2 5.0 21.5 3 3 7.5 29.9 102.7 1.6 3 4 12.5 10.5 3 5 15.0 11.3 4 1 2.5 9.1 4) 4 2 7.5 15.1 4 3 12.5 12.9 5 1 0.5 18.8 5 2 2.5 5.5 S 3 7.5 13.5 . . . ._......... . 4 r . . 1 ' ' : 1 I i fio%s6 D I I sEs.,E2 �,E,,,�H J r ♦ - 1 ...---)El - Y • £f Vst�w S. w j 1 r s r . u 4 ,.. is, , r I ..,,1 • _ 9 : . Y L r) • a I 1 Al LOCATION "Tr: ...___ ��t�.t SKETCH �� ' . I Client tI' 1t ''E SU1Efi e&.I edveraE-CZ . Project 111020.'1 /EVE ' l.✓iT�1i2�' 5 �� Proj. Location�S Sim 4 SLLt^1 o if 1 ¢ 3-3e- Scale .S • Pro'. No.�—Z Oste t • .,....n.• r�.�..... in / ,°// .. . �...� .... t k f.Y t• ' f4:v' i J. •�I ...• .4427 .• . ,.u-•�-�r 'r.e�r_.rte.s I . I/ r /0� 1 iGo ....8 IT co , . • • • • ..1: : . er .ft ti o .: .� ..:. V ........ _ — I.-4 •_ . .17•• ./S - 1 . me i joit) .,4,..■••■•■•••gm. ."7".. "'"'.....•■• .tg"S J SA ht j • 8_ �SEWER : 44 N s I ...411c. 1.004.,,10 tiJ Cre BK�CHN et, 4/n7 at � / ,�t�tion . N �,„►• � Ede .. vv4L4WZ ate`'!_ 4I� ~° f-,S '`` ��Sca/e The standard specifications referred to herein are made a part by eift reference and copies are on file with the City Clerk. r r SECTION 2: That the recommendation of the Board of Local Improvements of the City of Elgin, providing for the improvement, and the estimate of the cost thereof made by the President of the Board of Local Improvements, both hereto attached and made part hereof, be, and the same are hereby approved. 411) SECTION 3: That said improvement shall be made and the whole cost thereof, together with an amount not exceeding six per cent (6%) of the estimated cost, to-wit: ONE HUNDRED SEVENTY-NINE THOUSAND 'THREE HUNDRED FOUR DOLLARS ($179,304), which is hereby provided for to apply towards the cost and expense of making, levying and collecting said special assessment and all other expenses allowed by law, being the amount included in the estimate thereof, shall be paid by special assessment, in accordance with the Illinois Municipal Code, Article 9, Division 2, and amerdments thereto. SECTION 4: That the aggregate amount herein ordered to be assessed against the property and against the municipality, if any, and also the assessment on each lot and parcel of land herein assessed shall be divided as follows: The said assessment to pay the cost of construction of said improvement and the cost of levying, making and collecting said assessment and all expenses allowed by law, shall be divided into ten (10) installments, in the manner provided by the statute in such case made and provided. So much of the aggregate amount of the assessment as represents the cost of levying, making and collecting the special assessment and all expenses allowed by law, together with all fractional amounts so as to leave the remaining installments of the aggregate assessment equal in amount and each in multiples of $100.00 shall be apportionate to the first installment of the said special assessment. The first installment shall be due and pay- able on the 2nd day of January next after the filing of the first voucher issued on account of work done on the said improvement. The second install- ment of said assessment shall be due and payable one year thereafter, and so on annually until all assessments have been paid. IT IS HEREBY made the duty of the Board of Local Improvements of the CITY OF ELGIN, to file in the Office of the Clerk of the Court in which such assessment was confirmed, a certificate signed by the Secretary of the Board of Local Improvements of the CITY OF ELGIN of the date of the first voucher and the amount of the said voucher, within thirty (30) days after the issuance of the said voucher. All installments shall bear interest until paid at the rate of seven per cent (7%) per annum, being the rate now per- mitted by law. Interest on all installments shall begin to run in accordance with the provisions of the Illinois Municipal Code, Article 9, Division 2, and amendments thereto. Interest on such first installment shall be due and payable and shall be collected at the same time as the first installment. Interest on the second and succeeding installments shall be due and payable and shall be collected with the installments respectively as in said Code relating to special assessment provided. SECTION 5: That for the purpose of anticipating the collection of the second and succeeding installments of said assessment for the cost of said improvements, the CITY OF ELGIN shall issue bonds payable out of said install- ments, bearing interest at the rate of seven per cent .(7%) per annum, being 47) the rate now permitted by law, signed by the Mayor of the CITY OF ELGIN, and attested to by the City Clerk of said City. Said bonds shall be issued in accordance with and shall in all respects conform to the provisions of the Illinois Municipal Code, Article 9, Division 2, and amendments thereto. • • SECTION 6: That the Mayor of the CITY OF ELGIN be and he is hereby directed to file a Petition in the Circuit Court of the 16th Judicial rCircuit, Kane County, Illinois, in the name of the people of the CITY OF ELGIN, praying that steps may be taken to levy a special assessment for the purpose of defraying the expense of said improvement so far as the same may lawfully be done and to ascertain what property will be benefited, in accordance with the provisions of this ordinance, and in the manner pre- scribed by law. SECTION 7: That all ordinances, or parts of ordinances, in conflict with this ordinance, be, and the same are hereby repealed. SECTION 8: That this ordinance shall be in full force and effect from and after its passage and approval thereof according to law. s/ Richard L. Verbic Richard L. Verbic, Mayor Presented: September 23, 1981 Passed: September 23, 1981 Vote: Yeas 7 Nays 0 Recorded: Published: Attest: rik s ' Marie Yearman Marie Yearman, City Clerk r