Loading...
HomeMy WebLinkAbout22-130 Resolution No. 22-130 RESOLUTION AUTHORIZING EXECUTION OF A PURCHASE AGREEMENT WITH FIRE SERVICE, INC. FOR THE PURCHASE OF THREE WHEELED COACH AMBULANCES BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN, ILLINOIS, that pursuant to Elgin Municipal Code Section 5.02.020B(9)the City Council hereby finds that an exception to the requirements of the procurement ordinance is necessary and in the best interest of the city; and BE IT FURTHER RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN, ILLINOIS,that Richard G. Kozal, City Manager, and Kimberly A. Dewis, City Clerk, be and are hereby authorized and directed to execute a Purchase Agreement on behalf of the City of Elgin with Fire Service, Inc., for the purchase of three Wheeled Coach Ambulances, a copy of which is attached hereto and made a part hereof by reference. s/David J. Kaptain David J. Kaptain, Mayor Presented: July 27, 2022 Adopted: July 27, 2022 Omnibus Vote: Yeas: 8 Nays: 0 Attest: s/Kimberly Dewis Kimberly Dewis, City Clerk PURCHASE AGREEMENT This Agreement is hereby made and entered into this 27 day of July 12022, by and between the City of Elgin, Illinois, a municipal corporation (herein referred to as "City") and Fire Service, Inc.,an Indiana corporation,(herein referred to as "Fire" or"Seller"). NOW THEREFORE, for and in consideration of the mutual promises and covenants contained herein, the sufficiency of which is hereby mutually acknowledged, the parties hereto hereby agree as follows: l. PURCHASE. City shall purchase, and Fire shall sell the goods described by Attachment A attached hereto and made a part hereof, and as described in the Wheeled Coach specifications attached hereto and made a part hereof as Attachment B. 2. TERMS. This agreement shall be subject to the terms and conditions contained herein and as provided by Attachments A and B. 3. CONFLICT. In the event of any conflict between any of the terms and provisions of this purchase agreement and Attachment A or B hereto, the terms and provisions of this purchase agreement shall supersede and control. In the event of any conflict between Attachments A and B, Attachment A shall supersede and control. 4, LAWIVENUE. This agreement is subject to and governed by the laws of the State of Illinois. Venue for the resolution of any disputes or the enforcement of any rights arising out of or in connection with this agreement shall be the Circuit Court of Kane County, Illinois,without jury. SEC hereby irrevocably consents to the jurisdiction of the Circuit Court of Kane County, Illinois for the enforcement of any rights, the resolution of any disputes and/or for the purposes of any lawsuit brought pursuant to this agreement or the subject matter hereof.and Fire agrees that service by first class U.S. mail to Jeff Meyer, Fire Service, Inc., 9545 North Industrial Drive, Saint John, Indiana 46373 shall constitute effective service. 5. NO MODIFICATION. There shall be no modification of this agreement, except in writing and executed with the same formalities as the original. 6. MERGER. This agreement embodies the whole agreement of the parties. There are no promises,terms, conditions, or obligations other than those contained herein, and this agreement shall supersede all previous communications,representations,or agreements,either verbal,written or implied between the parties hereto. 7. INTEREST. Fire hereby waives any and all claims or rights to interest on money claimed to be due pursuant to this agreement, and waives any and all such rights to interest to which it may otherwise be entitled, pursuant to law, including, but not limited to, pursuant to the Local Government Prompt Payment Act (50 ILCS 505/1,et seq.)as amended or the Illinois Interest Act (815 ILCS 205/1 et seq.)as amended.The provisions of this paragraph shall survive any expiration, completion,and/or termination of this agreement. 8. SEVERABILTTY. The terms of this agreement shall be severable. In the event any of the terms or the provisions of this agreement are deemed to be void or otherwise unenforceable for any reason, the remainder of this agreement shall remain in full force and effect. 9. COMPLIANCE WITH LAW. Notwithstanding any other provision of this agreement it is expressly agreed and understood that in connection with the performance of this agreement, Fire shall comply with all applicable, federal, state,city and other requirements of law, including, but not limited to, any applicable requirements regarding prevailing wages, minimum wage, workplace safety and legal status of employees. Without limiting the foregoing, Fire hereby certifies, represents, and warrants to City that all of Fire's employees and/or agents who will be providing products and/or services with respect to this agreement shall be legally authorized to work in the United States. Fire shall also at its expense secure all permits and licenses, pay all charges and fees, and give all notices necessary and incident to the due and lawful prosecution of the work,and/or the products and/or services to be provided for in this agreement. City shall have the right to audit any records in the possession or control of Fire to determine Fire's compliance with the provisions of this section. In the event City proceeds with such an audit, Fire shall make available to City, Fire's relevant records at no cost to City. City shall pay any and all costs associated with any such audit. 10. PAYMENT. City shall pay Nine Hundred Sixteen Thousand Nine Hundred Twenty-Four and 00/100 Dollars($916,924.00) pursuant to Attachment A within thirty(30)days of delivery or City's receipt of invoice whichever is later.The aforementioned total sum is inclusive of all freight, shipping and applicable taxes, which shall be at Fire's sole expense. TRADE VALUE: Fire Service, Inc. will take in trade at time of delivery or sooner, (1) 2013 Wheeled Coach Ford F450 Type 1 Ambulance with Power Load, VIN#IFDUF4HT8BED5978, Production Number 311213 with l 109,838 miles at time of evaluation on or about May 18,2022. The value of the trade vehicle at this time is Twelve Thousand Dollars($12,000.00);and(1)2015 Wheeled Coach Ford F450 Type 1 Ambulance with Power Load,VIN# FDUF4HTOFEC83352, Production Number 351177 with 1 13,486 miles at the time of evaluation on or about May 20, 2022. The value of the tract vehicle at this time is Fourteen Thousand Dollars($14,000.00). The trade vehicle must be in the same physical and operating condition as when evaluated with all systems functioning as presented, or the trade value may be adjusted or withdrawn. Fire shall provide a Ford GPC Credit of$4,100.00 to City. Net totals: 3 Ambulances as proposed per ambulance $318,408.00 [$ 955,224.00J Trade Value—2013 WC#311213 ($ 12,000.00) Trade Value—2015 WC#351177 ($ 14,000.00) FORD GPC Credit(Per 3 ambulances) ($ 4,100.00) [$ 12,300,00] Total Net purchase: $916,924.00 The City is a tax exempt governmental entity All prices are inclusive of any taxes. NOTE: Payment shall be made to: 2 Fire Service, Inc. 9545 North Industrial Drive Saint John, Indiana 46373 it. TERMS OF PAYMENT. F.O.B. St. John, IN. Zero down payment, full payment via wire transfer or municipal check. The purchase price payment reflects US dollars and does not include any authorized change orders which, if applicable,shall be paid at time of final inspection and signed acceptance. The ambulance and equipment covered by this contract shall remain the property of Fire and shall not be placed in service until the full contract price has been paid. 12. DELIVERY. Delivery is as provided by Attachments A and B hereto. Due to the uncertainty within Ford manufacturing, any changes to Ford GPC concessions applied to this contract or change to model year availability by Ford shall not be the liability of the seller. Proof of Ford concession changes, if applicable will be provided for the buyer to validate. Purchaser shall be liable for the OEM GPC and Model year cost changes after the date of this contract. Due to current and ongoing restraints of the Chassis manufacturer and the Upfitters(Manufacturer) to control supply chain materials outside of their control, Fire will advise the City at each stage of the process, and establish tentative timelines only after the receipt and signed acceptance of this contract at the REV Ambulance Group Orlando Corporate Headquarters, Winter Park, FL., the confirmation of the build order, and the arrival of Customer chassis. Fire shall not be liable for penalties and I or delays due to strikes, failures to obtain materials, fires, accidents, force majeure, global pandemic or any other causes beyond Fire's control. In order to establish a stable design,procurement,and build schedule,City unilateral change orders shall have a cutoff date of eight(8)days from the date of the execution of the contract shall apply. Changes in major components, configuration, or other items that may change the major components or configuration, (e.g.: Chassis, Motor, Transmission, Wheel Base) shall not be allowed after the contract execution date. If inability to obtain exclusive or brand name materials causes completion or delivery problems, Fire shall advise the City of said problem in a timely manner. Fire shall examine alternative sources of said materials. Material substitutions shall be mutually agreed upon by the City and Fire. No substitutions shall be made without the execution of a written change order by the City. 13. LIMITATION OF DAMAGES. Notwithstanding anything to the contrary herein, in no event shall City be liable for any monetary damages in excess of the purchase price contemplated by this agreement. In no event shall City be liable for anv consequential, special, or punitive 3 damages resulting from loss of profit. 14. EXECUTION. This agreement may be executed in counterparts, each of which shall be an original and all of which shall constitute one and the same agreement. For the purposes of executing this agreement, any signed copy of this agreement transmitted by fax machine or e-mail shall be treated in all manners and respects as an original document. The signature of any party on a copy of this agreement transmitted by fax machine or e-mail shall be considered for these purposes as an original signature and shall have the same legal effect as an original signature. Any such faxed or e-mailed copy of this agreement shall be considered to have the same binding legal effect as an original document. At the request of either party any fax or e-mail copy of this agreement shall be re-executed by the parties in an original form. No party to this agreement shall raise the use of fax machine or e-mail as a defense to this agreement and shall forever waive such defense. 15. TRANSFER OF TITLE/RISK Transfer of title, and risk of loss shall pass to City upon delivery of the goods. All transportation and delivery costs shall be at Fire's sole expense. 16. CHANGE ORDERS. Changes to the contract may be requested by either party hereto after the execution of this contract. Changes shall be reviewed for cost and schedule impact by both parties. Changes shall be sequentially numbered. The price of the apparatus shall be adjusted to take into account any change orders. Any and all change orders may extend the completion and delivery of the ambulance. 17. SPECIFICATIONS. Fire agrees that all material and workmanship in and about this apparatus shall comply with the attached Wheeled Coach proposal dated May 20, 2022 and clarifications and as described by Attachments A and B hereto. (3)2022 Ford F550 Wheeled Coach Type 1 Ambulance per City of Elgin FD Specifications. 18. WARRANTY. Shall be as proposed in the attached Wheeled Coach specifications. 19. The unit shall be inspected and /or delivered within seven (7) days of notice that the unit had been completed. 20. CANCELLATION. This contract is subject to cancellation by City only upon payment to Fire of reasonable cancellation charges, which shall take into account expenses already incurred and commitments made by Fire. This contract, to be binding, must be signed by an officer of Fire Service, Inc. or a person authorized, in writing, by Fire Service, Inc. to do so. 21. TAG-ON /ADDITIONAL ORDERS. At its sole discretion, Fire may allow the terms of this contract to be extended to both City and similar agencies for the purchase of a similar unit(s) under similar terms for a period of three (3) years from the date of the execution of this contract. Should Fire choose to exercise this option, it shall be permitted to adjust the contract pricing for such similar units which may be purchased in the future to account for equitable price adjustments 4 associated with the change in the cost of the materials used to produce the unit. Such adjustments will be based upon the Producer Price Index (PPI) for fire trucks and / or heavy transportation equipment or by itemizing price changes expected by Fire from the component vendors. If there are any changes between the unit(s) purchased via this contract and any subsequent orders, those changes shall be documented via properly signed and executed change orders, including any necessary price adjustments. If the purchasing agency is not the City, a separate contract will be required to complete the additional purchases. This contract, including its appendices, embodies the entire understanding between the parties relating to the subject matter contained herein and merges all prior discussions and agreements between them. No agent or representative of Fire has authority to make any representations, statements, warranties, or agreements not herein expressed and all modifications of amendments of this agreement, including any appendices, must be in writing signed by an authorized representative of each of the parties hereto. No surety of any performance bond given by Fire to City in connection with this Agreement shall be liable for any obligation of Fire arising under-the standard warranty. IN WITNESS WHEREOF, City and Fire have caused this contract to be executed by their duly authorized representatives this 27 day of July 2022. FIRE SERVICE, INC. CIT GIN Jeff Meyer tRichard G. Koza Ci ty Manager Signature C ! Attesti JJes oe City Cler Title i..Bul I>opt Agrocwcut-Ilic 5cnitu hm-7-0-22,11Ucx 5 �0 ATTACHMENT A do Emergency Vehicle Sales and Service Robb Cagann May 20,2022 Elgin Fire Department 150 Dexter Ct. Elgin,IL 60120 Hey Robb, Thank you for allowing us the opportunity to work with you on this project.I have quoted you the Wheeled Coach 1170 on a Ford F550 4x4 Diesel chassis.The unit has been upgraded to include the lights according to your configuration,Stryker Power Load,and custom interior design.The chassis model year may change depending on the timeframe of your decision and the manufacturer's build schedule. Please pay special attention to the times and disclosures that are included with this proposal. Here are the proposed estimates that you requested.Proposal expires on July 18,2022. Ambulance-Diesel 2022 Ford F550 WC 1170 Diesel per attached specs each $318,408.00 GPC Ford Concession(05/18/22)* ($4 100 00)* Net Amount Each Ambulance $314,308.00 2013 WC Prod#311213 Trade Value w/Power Load (12,000.00) 2015 WC Prod#351177 Trade Value w/Power Load (14,000.00) Net Total for 3 Ambulances $916,924.00 * Due to the uncertainty within Ford manufacturing,we will honor the price of this bid,although any changes to Ford GPC concessions applied to this quotation or change to model year availability by Ford cannot be the responsibility of the seller. Proof of Ford concession changes,if applicable will be provided,for the purchaser to validate. Purchaser will be responsible for the OEM cost changes after the date of this proposal. *Components and Vendor Supplied Items included in the contract price(Stretchers,Equipment Mounts,etc.)are subject to inflationary price increases unless prepaid by the customer. Terms:Zero down FOB Winter Park,FL.Payment by wire transfer or corporate check at delivery. Delivery timetable:Expected delivery is 22 months from date of order.Due to the current and on going restraints of the Chassis manufacturers and the Upfitters(Manufacturers)to control supply chain materials outside of their control,The Company will advise the Buyer at each stage of the process,and establish tentative timelines only after,the receipt and signed acceptance of this contract at the REV Ambulance Group Orlando Corporate Headquarters,Winter Park,FL.,the confirmation of the build order and the arrival of customer chassis. The Company cannot be held liable for penalties and/or delays due to strikes,failures to obtain materials,fires,accidents,force majeure,global pandemic or any other causes beyond the Company's control. I am confident that when we work together,we will be able to reach your needs to perform your jobs,but also stay fiscally responsible for the Village. Thanks again and I look forward to working with you! P# Jeff Meyer,Ambulance Sales Rep—Northern IL Jmever(@fireserviceinc.com cell:224-828-1597 1719 South Franklin Road 9545 Industrial Drive North 1743 Quincy Avenue, Suite 155 Indianapolis, Indiana 46239 St. John, Indiana 46373 Naperville, Illinois 60540 219-365-715 7. Office Phone Website: www.Treserviceinc.com 219-365-8572:Office Fax Toll Free:800-578-4281 ATTACHMENT B , Wheeled Enach' Iq--- /GR0UP Elgin Fire Department Fire Service Inc Robb Caggan Jeff Meyer 150 Dexter 1743 Quincy Ave Elgin, IL 60120 Ste 155 January 22, 2019 Naperville, IL 60540 224-828-1597 jmeyer@fireserviceinc.com Exp. Date: 01/01/2022 Rev. Date: 12/05/2021 Quote No: 10039-0002 12/05/2021 11-01:01 Pa e 1 PART NO • QTY ID _=WC-Wheeled Coach Boilerplate -1.017 11/12/21 == 1 REV ORDER COORDINATOR 1 REV 00-00-0015 Order Coordinator-Factory to assign 1 REV INFORMATION 1 REV 00-01-4005 > State Contract 1 REV WARRANTY 1 REV 00-02-8720 WC, Warranty, Paint, 60 month Prorated, Standard 1 REV 00-02-8730 WC, Warranty, Structural, 20 Years, Std., Mods 1 REV 00-02-8740 WC, Warranty, Limited Electrical 1 REV 00-02-8750 WC, Warranty, Cabinet Construction 1 REV 00-02-8775 > WC, Warranty, Extended to 3 Year/36K Miles, Types 1, 3, 9 1 REV _=WC-Type 1 170 Module -1.017 11/12/21 == 1 REV CERTIFICATIONS REQUIRED 1 REV 00-05-0050 < This unit built in accordance with KKK-A-1822-F in effect on 1 REV SHOP NOTE: the date of order with exceptions as noted herein. 00-05-0100 < MD, This unit built in accordance with KKK-A-1822-F CN 10 Cabinet 1 REV Requirements SHOP NOTE: This unit as specified meets all requirements of KKK-Al822-F Change notice 10. All cabinets shall be labeled as to their capacity Rating. 01-CHASSIS REQUIREMENTS 1 REV FORD CHASSIS 1 REV 01-01-2518 < > WC, 2022 Ford F550, XLT 4X4, 193"W/B, 18,000 GVWR (Special Order)2022-4 1 REV SHOP NOTE: Auto throttle OEM Ford Dual Alternators OEM Ford Mirrors, OEM, Heated/Remote Cab seats OEM 40/20/40 split bench (Center removed) New for 2020-Sync 3 Enhanced voice recognition communication and entertainment system 8" LCD Capacitive Touch screen in center stack w/swipe Capability Pinch to Zoom ca abilit 12/05/2021 11:01:01 Pape 2 PART NO S DESCRIPTIONCITY ID AppLink 911 assist Apple carPlay and Android Auto Smart-charging USB-C Ports (2) 01-02-0100 Domestic Chassis 1 REV 01-02-01SR X < OEM Front Bumper Black 1 SHOP NOTE: SR# OEM Front Bumper Black ILOS (SAP#10814190) Part#10499042 Ref only unit#433688 note bumper only Ford F550 bumper Primed Paint shop will paint this bumper Black Line X Provided by Rich @ Greenway Ford 01-02-02SR X < Ignition Security System, Intermotive Idle Lock 1 SHOP NOTE: SR# Ignition Security System, Intermotive Idle Lock (SAP#10549291) SR#220349F With sw. located on dash to the right of the steering column, Set up, per Elec Eig . P/N-B-Idle505-A for a 2023 F550 ALTERNATORS 1 REV 01-03-1001 Alternator-Standard OEM 1 REV SUSPENSION 1 REV 01-07-7614 < MD, Rear Suspension, Liquid Spring-2017+ F550, 18k GVWR, 4x4 1 REV SHOP NOTE: Dump Feature activated by the Left rear access door. Override switch to be on right rear entry door Ignition switch Hot, Standard. Per KKK, the rear suspension shall only lower the module when the vehicle is in ark and the parking brake is set. HIGH IDLE 1 REV 01-13-1675 High Idle Controls, OEM 1 REV FRONT END ALIGNMENT 1 REV 01-17-7501 Front End Alignment, None-QC Check-Standard 1 REV 01-19-0003 < WC, Wheeled Coach Stainless Grille Logo, with Red Reflective backing 1 REV SHOP NOTE: Red reflective behind cut out. OUTSIDE REAR VIEW MIRRORS 1 REV 01-20-0104 Mirrors, OEM-STD 1 REV WHEEL COVERS 1 REV 01-24-2023 < > MD, Wheel Covers, Delete& Paint Inside&Outside of Rim (per tire) 5 REV SHOP NOTE: Paint Code Red#FRE 3015 5 wheels, Outside and Spare 01-24-2202 < > MD, Extenders,Valve, Air Max, Installed 1 REV SHOP NOTE: (will not work on aluminum wheels) BASE CONVERSION 1 REV 12/05/2021 11:01:01 Pa e 3 PART NO S DESCRIPTIONQTY ID 01-45-0226 MD, Conversion, Type 1, 170 Module, F550 4x4 21-4 1 REV MODULE BODIES: 1 REV 02-01-2122 MD, Interior Headroom, 72 Inches 1 REV 02-01-3124 < MD, Module, Type 1, 170" Body Length, Duraseam Doors, 1 REV SHOP NOTE: 170" L x 95"W 02-01-3152 MD, Body Width 95"Standard 1 REV 02-01-9564 < MD,Aisle Space, 50", Type 1 1 REV SHOP NOTE: (49-50" actual) Requires stainless steel wheel well covers attached to squad bench and base wall cabinets that will protrude up to 1.5" into aisle way on each side. 02-02-1301 > MD,All Module Skins, 0.125 inch 1 REV STRUCTURAL FRAMING-RFP 1 REV 03-01-1501 MD, Type 1, General Body Construction Spec 1 REV 03-01-1503 MD, Type 1, Vehicle Body Structure Spec 1 REV UNDERCOATING 1 REV < EXTERIOR MODULE CONSTRUCTION 1 REV SHOP NOTE: Prod note see Line X package IATS Front bumper-Rear bumper-Front stone guards and corner caps-Rear kick plate and corner caps-fuel fill/Def housing's and splash guards-rear tag holder recessed D cylinder storage in CS entry step well for FW521 brackets 6 inch drop skirt 03-03-1000 X < Zinc Anode Plates 1 SHOP NOTE: DO NOT UNDERCOAT Each Plate Welded to the Aluminum Floor Structure Near the OEM Frame Rails, (3) Each Side of Module for Dealer Installation of Zinc Anode Plates 03-03-1049 MD, Stone Guard, Front, Diamond Plate, 24" 1 REV 03-03-10SR X < Polyurea Package, All Exterior Diamond Plate, Black Polyurea 1 SHOP NOTE: SR# (SAP# 10768851) Previous SR#2181312F In house Black Poly urea/Line X Black-out front bumper. Running Boards, Stone Guards, corner caps,Kick plate, front stone guards, License plate holder, fuel fill plates (2)fuel fill housing's, rear bumper. DROP SKIRTS 1 REV 03-03-2513 < > MD, Drop Skirt both sides, 6"forward of rear wheels 1 REV SHOP NOTE: Note: Bright finish fender flares will not work, must use rubber 12/05/2021 11:01:01 Pa g 4 PART NO S DESCRIPTIONOTY ID < FUEL FILLS&SPLASH PLATE 1 REV SHOP NOTE: Black Out package 03-03-8030 > MD, Housing Fuel Fill, Cast Aluminum, Type 1 1 REV 03-03-8335 < MD, Fuel Fill Splash Plate, Stainless, 10in Wide 1 REV SHOP NOTE: - installed below fuel fill full perimeter to bottom of skirt rail to protect body- atta h to body using double sided tape-no screws < DEF FILL HOUSING AND SPLASH PLATE 1 REV SHOP NOTE: Black Out 03-03-8615 MD, DEF Fill, Housing, For Ford F series 1 REV 03-03-8630 < MD, DEF FILL Splash Plate, Stainless, 10in Wide 1 REV SHOP NOTE: - installed below fuel fill full perimeter to bottom of skirt rail to protect body- atta h to body using double sided tape-no screws < REAR KICKPLATE 1 REV SHOP NOTE: Black Out 03-03-9066 WC, Rear Kick plate,Under-Ride Bumper, w/Tag recess, No lights 1 REV SUB-FLOOR SYSTEM 1 REV 03-04-0166 MD, Flooring, 3/4" Marine Grade Plywood, Type 1 1 REV MODULE ENTRANCE 1 REV 03-05-0200 MD, Module Access, CS Door standard location 1 REV MODULE DOORS, HANDLES& HOLD OPENS 1 REV 03-06-0115 < WC, Duraseam Hinged Doors with Hidden Jambs 1 REV SHOP NOTE: -Magnetic door switches, Standard 03-06-0713 < > MD, Hold Open Rear Entry Doors, (2) 5.5"Cast Grabber 1 REV SHOP NOTE: - Installed so doors will open as wide as possible - Mount at Bottom of doors. 03-06-0817 < MD, Hold Open-Gas Strut, Curb Side Entry Door, 35# 1 REV SHOP NOTE: New Code Per ECN 1823 03-06-1027 < WC, Patient Entry Door Handles, Trimark Black/Chrome Pull Handle 1 REV w/"SafePass" SHOP NOTE: With Round Push button Emergency release top and bottom of interior door panels 03-06-1047 > WC, Rear Entry Door Trailing Latch, Side release Paddle 1 REV 03-06-4201 MD, Electrical Feed to Required Doors, Spring Protector 1 REV POWER DOOR LOCKS 1 REV 03-06-6120 < > WC, Power Door Lock, Trimark, Each Entry Door 2 REV SHOP NOTE: Module entry doors. Pick switches in 03-06-6130 12/05/2021 11:01:01 Page 5 PART NO S DESCRIPTIONQTY ID 03-06-6121 < > WC, Power Door Lock, Trimark, Each Compartment Door 6 REV SHOP NOTE: All module compartments(except battery comp) . (unless other specified) 03-06-6130 < > MD, Switch, Momentary Rocker,Activate Power Door Locks 1 REV SHOP NOTE: If 1 then Installed on C/S wall at head of S/B. If 2 2nd located on right rear door 03-06-6134 < > MD, Switch, Remote Stealth, Cab/Mod Doors 1 REV SHOP NOTE: In grille on passenger's side. 03-06-6137 < > MD, Relay Control Circuit, Power Door Locks 1 REV SHOP NOTE: (Use drop down menu to pick keyless entry if required) 03-06-6140 MD, Circuit, OEM Door Lock to activate Mod Doors 1 REV 03-06-6207 > MD, Intermotive CAN module for 2017+ Ford F-series 1 REV ENTRY DOOR INNER PANELS 1 REV 03-06-7335 < > WC, Entry Door Panels, Durasafe, S/S,w/Chevrons & Red Reflective LOGO 1 REV SHOP NOTE: -Durasafe Design -Aluminum Center Panels covered: white/red reflective tape - Logo to be cut in the lower entry door panel with a RED reflective 3M materia (to match the chevron on the lock box) attached to an aluminum panel behind the logo 03-06-73SR X < Aluminum Centers with Chevron 1 SHOP NOTE: SR# (SO-PANEL-351178) SR220147F Alum center panels will be covered with diamond grade NFPA Red/Yellow 4" the ron striping by 24/7. 45 degree andle to match rear of module. < SIDE DOOR STEP 1 REV SHOP NOTE: Eng note recessed at wall 1for(2) D cylinder storage cabinet at head of squad bench. 03-08-2112 MD, Side Entry Step Well, Type I,Aluminum Diamond Plate 1 REV 03-08-2157 < MD, Double Step Step Well 1 REV SHOP NOTE: Black Line X step area, recessed cylinder storage at head of bench! 03-08-21SR X < Polyurea CS Stepwell 1 SHOP NOTE: SR# Polyurea CS step area ILOS SR#220147F Delete lower S/Steel threshold at CS door way. Extend Line X to bottom edge of CS body Skin See reference drawings, Black Line X ILOS, contact sales ext. 285 if you have Any questions 03-08-3056 MD, Light, Side Entry Step well, LED, Whelen#TOCACCCR, 2" 1 REV WINDOWS 1 REV 12/05/2021 11:01:01 Pa e 6 PART NO S DESCRIPTIONQTY ID 03-09-4109 > MD, Window, Upper, CS/Slider, Rr/Fixed, Privacy Tint, PAN 1 REV MODULE TO CHASSIS MOUNTING SYSTEM 1 REV 03-10-1210 MD, Module to chassis mounting system, Type 1 1 REV CAB TO MODULE 1 REV 03-11-2502 < > MD, Bellows, Pass thru, Unigrip, F1 2008+, 1 REV SHOP NOTE: With Aluminum cab insert. REAR BUMPER AND REAR STEP CONSTRUCTION 1 REV 03-12-2503 < MD, Rear Bumper w/Skids & Flip Up, F1/C1, w/LED DOT lights 1 REV SHOP NOTE: w/Gator Grip on flip up step. 03-12-2550 < MD, Coating, Polyurethane, Rear Bumper Supports 1 REV SHOP NOTE: Black 03-12-25SR X < Rear Bumper 12" Deep ILOS Standard 1 SHOP NOTE: S R# Bumper, Rear, w/Skids&Flip Up, F1, w/LED DOT Its, 12" ILOS (SO-BMPR-351178) SR 220147F Eng same as 488594 with under ride style, k k plate, rear bumper Black Line X. 12 INCH DEEP BUMPER ILOS w/Gator Grip on Flip up Step INSULATION 1 REV 03-13-3008 < > MD, Insulation, Severe Weather Package 1 REV SHOP NOTE: one inch block foam in modular walls and roof covered with reflective insulation. Under Floor to be Spray Foam insulated after the production assembly procesE is complete by 24/7. All edges of reflective insulation on walls and ceiling must be taped. std. RUB RAIL AND FENDER RINGS 1 REV 03-15-66SR X < Skirt Rail, Black Plastic, FDNY Style ILOS 1 SHOP NOTE: SR# Skirt Rail, Black Plastic, FDNY Style ILOS (SAP#10498898) SR#2181312F FDNY style skirt rails should be same as 488594 03-15-8350 MD, Fender Flare, Black Rubber 1 REV SPLASH GUARDS AND RUNNING BOARDS 1 REV 03-16-1721 WC, Mud Flaps, Rear, w/Wheeled Coach Logo 1 REV 03-16-3605 < MD, Running Boards, F450, w/Gator Grip 1 REV SHOP NOTE: NOTE LED Lights in front stone guard! Adjust light, as needed due to running bo rd, Black Line X DRIP RAILS 1 REV 03-17-1020 MD, Drip Rail Trim Moldings Over Door Openings 1 REV CAB TO PATIENT AREA ACCESS 1 REV 12/05/2021 11:01:01 Pa e 7 PART NO S DESCRIPTIONQTY ID 03-19-2301 MD, Bulkhead, Unigrip, Type 1F/D, Pass Thru, w/Sliding Lexan Window 1 REV 03-19-23SR X < Bulkhead 1 SHOP NOTE: SR# Bulkhead (SO-BH-351178) SR220147F AC unit over pass through. Eng ref only 357921 Pass through, with Lexan slider at pass through (1) Bi fold door for CB access to the drivers side of pass through (1) Bi fold door for PC board, above pass through (1) Door under pass through same as 357921 LICENSE PLATE HOLDER 1 REV 03-20-4053 < WC, License Plate Holder, Cast LP0002-1 for Under ride Bumper 1 REV SHOP NOTE: Part of Blackout package in rear kick plate, centered License holder comes with (2) LED lights. EXTERIOR COMPARTMENT CONSTRUCTION 1 REV 04-01-0504 < > MD, Exterior Compartment, Sweepout, Each 6 REV SHOP NOTE: -All Compartments are standard sweep out 04-01-3017 < MD, Door Sill Protector, Stainless, All Compts 1 REV SHOP NOTE: Door Sill Protection - Install Stainless Steel sill protector on lower edge of all oor frames to prevent paint damage NOTE No sill protector at CS entry door. door jamb will have black Line X ILO , to bottom edge of skin under CS entry door way. 04-01-5106 < MD, Polyurethane Coating per compartment 6 REV SHOP NOTE: light gray EXTERIOR COMPARTMENT DOORS 1 REV 04-02-0506 > WC, Compartment Comp Handle, Trimark, Oval Pull Handle, Black/Chrome 6 REV 04-02-0514 < > WC, Compartment Door Latch, Edge Paddle, Trimark, Trailing Door 1 REV SHOP NOTE: Interior edge style handle comps"#2" &/or"#4" COMPARTMENT DOOR HOLD OPEN 1 REV 04-02-7751 < > MD, Hold Open, Gas Strut, Ext Compt,601b 1 REV SHOP NOTE: for comp. #4 hold open 04-02-7755 < MD, Hold Open, Gas Strut, Comp Door Only, 110 Degree, 301b 1 REV SHOP NOTE: Compartments 1, 2 (2) , 6, 6.5 04-02-7757 MD, Hold Open, Gas Strut, RF Compt, 301b 1 REV COMPARTMENT LIGHTING 1 REV 04-03-1483 X < MD, Compartment Light, LED, Whelen#TOCACCCR, 2 in, Each 1 SHOP NOTE: Compartment#1 for 02 04-03-1486 < MD, Compartment Lighting, LED Hi-Brite Flex, 160+ Module 1 REV SHOP NOTE: (new code) both vertical edges near door jambs and across top edge 12/05/2021 11:01:01 Pa e 8 PART NO S DESCRIPTIONCITY ID near door jamb, compartments "1", "2", "4", "6", "6.5", & "8". 6" Hi-Brite Piece a 02 light EXTERIOR COMPARTMENT INTERIOR 1 REV 04-04-2714 > MD, Dri Deck, Black,All Compt. Floors and Shelves 1 REV 04-05-7014 < > MD, Reinforcement, Compartment Wall, For SCBA Bracket 1 REV SHOP NOTE: Wall 2 Comp D for 3 scba brackets, 2 in comers and 1 on wall 2, between the 2 in the corners. Eng same as 525251 COMPARTMENT#1 -STREETSIDE FWD 1 REV 04-06-0451 < MD, Compartment#1, Full Height 1 REV SHOP NOTE: Reference 357921 customer's 2019/2020 With Dogleg for Stairchair in Compt"F" (9.5"wide) DOG LEG FOR STAIR CHAIR. Door to open past 90 degrees. Eng note this 2020 unit will have a TOCACCCR LED 02 light ILOS 04-06-0475 < MD, With Dogleg for Stair chair in Compartment#1, 1 REV SHOP NOTE: (not available when electric 02 rack is selected) (this will decrease space for attend seat&cot by 5.25") for stair chair 04-06-1550 < > MD, Compartment#1, Shelf,Adjustable, W/Alum Track, First shelf 1 REV SHOP NOTE: Wall 1 to divider above stair chair height 04-06-1551 < MD-Compartment#1, Shelf, Adjustable,Additional, Each 1 REV SHOP NOTE: Wall 3 to divider above 02 window height 04-06-1831 < MD, Compartment#1, Fixed Divider, Vertical, Full Height 1 REV SHOP NOTE: Mounted at edge of dogleg 1/2 height divider, mounted wall 2 &ceiling Customer requires lower area of compt to be clear for stair chair storage. Same as 525251 04-06-1939 < MD, Compartment#1, Strap, Seat Belt style, Each 1 REV SHOP NOTE: Compt 1, wall 1 to wall 2 to hold stair chair in place. Leave 4 inch tail for strap adjustment COMPARTMENT#2-STREETSIDE FWD WHEELWELL 1 REV 04-07-2144 < WC, Compartment#2, 50"Aisle, Standard Configuration 1 REV SHOP NOTE: Eng reference 357921 With Double Doors Eng note see AA tray Unit will only have a slide out tray in AA, but will require space to bolt in a monitor on the AA cabt above this dogleg. Drop writing tray 3/4 on an inch below standard for inside height of 2.75" space to allow 1/4 alum plate for defib mount in rearward end of AA, thru bolted. 12/05/2021 11:01:01 Page 9 PART NO S DESCRIPTIONQTY ID 04-07-2632 < MD, Compartment#2. Shelf, Fixed, Electrical storage, No Divider 1 REV SHOP NOTE: Elec Eng note. Relocate GFI breaker box to compt 2, on wall 1 of compt, up high on electrical shelf, toward outer edge of shelf for easy access, trim elec overflow cage so the customer can reset breaker easily if needed. Install black stampro on sharp edges of cage as needed. 04-08-2100 > MD, Compartment#3, NONE 1 REV COMPARTMENT#4-STREETSIDE AFT 1 REV 04-09-3247 MD, Compartment#4, Mid Height 1 REV 04-09-4550 < > MD, Compartment#4, Shelf,Adjustable,w/Aluminum Track, First Shelf 1 REV SHOP NOTE: Just above SCBA tanks 04-09-8000 X Compartment#4, Unistrut Backwall for SCBA brackets 1 04-09-8004 < MD, Compartment#4, Zico ABS, Angled bracket for Mounting SCBA, Each 2 REV SHOP NOTE: A .250 aluminum plate welded into comer of wall and Wall _ of compartment to be used for mounting SCBA Brackets. Floor level COMPARTMENT#6 -CURBSIDE AFT 1 REV 04-11-1097 MD, Compartment#6, Full Height 1 REV 04-11-2097 < MD, Compartment#6, Divider, Vertical, Fixed, 3/16"Thick , Each 1 REV SHOP NOTE: (divider to be full depth if a shelf is requested) 10.5" off wall#1 04-11-4530 < > MD, Compartment#6, Shelf,Adjustable, First shelf w/Aluminum Track 1 REV SHOP NOTE: From divider to wall 3 approx 44"off finished floor COMPARTMENT#6.5-CURBSIDE AFT WHEELWELL 1 REV 04-12-0130 WC, Compartment#6.5, Below Squad Bench Floor Level 1 REV COMPARTMENT#8-CURBSIDE UPPER FORWARD 1 REV 04-14-2160 > MD, Compartment#8/8.5, Split Doors, Reduced Height Upper 1 REV 04-14-21 SR X < Custom#8/8.5 1 SHOP NOTE: SR# Custom RFC #8 SR220147F Engineering same as 357921 Dealer requires a Modeled view of design for appro fal prior to assembly still applies to this new unit!! U8 cabinet over Drawer over L8 cabinet. Door Compt 8 to be L8 (ISOS access). Eng door#8 sized to access L8 area only. Lower compartment for 2 battery tray. (8.5) 04-14-8010 < > MD, Compartment#8, Shelf,Adjustable, RF Cabt, First shelf w/Aluminum Track 1 REV SHOP NOTE: (1) RF Compt"A"/cabt"U8"area, 14.5"from center of shelf to ceiling of cabinet. Shelf from wall 1 to wall 3 of upper U8 cabinet, below upper cabt dogleg that's on wall 3 and above knox box closeout. 04-14-8015 < > MD, Compartment#8, Shelf, Adjustable,Additional, for Aluminum Track, Each 1 REV SHOP NOTE: 12/05/2021 11:01:01 Pape 10 PART NO S DESCRIPTION RF Compt"A"/cabt"18"area evenly spaced. INTERIOR TRIM AND FEATURES 1 REV 05-01-0105 < > MD, Interior Cabinets, Duralite Construction, Wood, CN10 compliant 1 REV SHOP NOTE: All cabinets shall be labeled with their Rated Weight Capacity. INTERIOR ADJUSTABLE SHELVES 1 REV 05-02-0050 < > MD, Shelf, Interior,Wood , (1)adjustable, in Cabinet 4 REV SHOP NOTE: (2) C4/C3, one each side of divider U4 Combo U2 Combo 05-02-0054 < > MD, Shelf Track, Cabinet, #HA24663, CN 10 Upgrade 4 REV SHOP NOTE: ("C"channel/exterior shelf style track) "This option may require quantity adjustment"* < HEADLINER 1 REV SHOP NOTE: SEE Antenna Placement on work order. Eng note provide liner layout for customer's file 05-06-2860 < >WC, Headliner, Flat, PVC, Hinged trough cover, 160"+ 1 REV SHOP NOTE: ref only 525251 Eng note no 02 and only 1 IV hanger. FLOORING 1 REV 05-07-0120 < > MD, Flooring, Lon Seal"Lonplate II " 1 REV SHOP NOTE: With approximately 3"roll up both street side and curbside. 05-07-0122 MD, Color, Gunmetal Gray#424 1 REV 05-07-9896 MD, Floor, Thresholds, Stainless Steel,Painted w/Black Poly-urea coating 1 REV Entry Door Grab Handles 1 REV 05-10-1529 < MD, Entry Door Grab Handles(3), Custom"L"Shape, 1", Yellow 1 REV SHOP NOTE: -Yellow Powder Coat Finish Stainless Steel Grab Handles Ceiling Grab Rail -Center 1 REV 05-10-1931 < > MD, Ceiling Grab Rail, Overhead,112", 1"diameter Handicap Style, Yellow 1 REV SHOP NOTE: Yellow Powder Coat Finish GRAB HANDLES 1 REV 05-10-7528 < MD, Grab Bar, 12" Long, 1.25" Handicap Style, Stainless Steel 1 REV SHOP NOTE: mounted on exterior outside CS entry door PAINTED to match module job color Red#FR#3015 IV FLUID HANGERS 1 REV 05-11-0015 > MD, IV Hook, Perko Snap Hook w/Velcro Strap, Each 2 REV 05-11-0017 < > MD, IV Hook, Cast, Fold Down Recessed Each 1 REV SHOP NOTE: (1) Between dome 2 and 3 curbside 12/05/2021 11:01:01 Pa a 11 PART NO S DESCRIPTIONQTY ID ACTION WALL AREA#2 1 REV 05-13-3086 MD, Cabinet,A/A, 50"Aisle, No Bio waste, Rounded corners 1 REV 05-13-4322 < > MD, Tray,A/A, 50"Aisle, No Bio waste, Poured, Gray 1 REV SHOP NOTE: —only for 50"aisle space units" 05-13-4398 < > MD, Writing Tray, Slide out, Under A/A Tray 1 REV SHOP NOTE: REF 525251 Drop writing tray 3/4 of an inch below standard for inside height of 2.75"space to a low 1/4 alum plate for defib mount in rearward end of AA, thru bolted. Eng note see barrel bolt option added, to hold this tray in the closed position. (Only available with no bio waste in A/A) 05-13-4414 MD, AA Upper Cabinets, U2.5, U2, Combine into 1 Large Cabinet, Full Ht Comp 1 1 REV CABINET DOORS 1 REV 05-13-4574 > MD, Doors, "U2.5,U2,U1" Combined, Gray Poly carbonate Slider, CN 10 C 1 REV Interior Streetside#3-CPR Seat 1 REV 05-14-1532 MD, CPR side seat, Fixed Backrest 1 REV 05-14-1534 < MD, CPR, Lid, Hinged Flip Up 1 REV SHOP NOTE: With Trimark Latch 05-14-1547 MD, Cabinet U3.5 1 REV 05-14-1559 < > MD, Cabinet U3, w/CPR seat(ONLY Available in 72"HR) 1 REV SHOP NOTE: Note: TO meet 43" minimum KKK requirement for space between cushion on S de seat and bottom of splint cabinet. 05-14-1577 MD, Cabinet C3.5, deleted For Telemetry Area 1 REV 05-14-1591 XS < > MD, Cabinet L3.5, Custom 1 REV SHOP NOTE: SR# Custom L3.5 (SO-0-351178) Prev SR220147F Reference 525251 Wood door hinged at bottom. Note single southco latch Add (2) cables to hold door at approx. 30 degrees 05-14-4418 < MD, "U" Barrier Bar, Padded, 1.5"SS, CPR Seat, Gunmetal 1 REV SHOP NOTE: Mounted at the front of the CPR side seat vertically in line with the Padded h ad cushion on the upper AA cabinets. 05-14-4552 MD, Telemetry Tray, Poured, Gray 1 REV CABINET DOORS 1 REV 05-14-4592 MD, Doors, U3.5 Gray Poly carbonate Slider, CN 10 Compliant 1 REV 05-14-4614 < > MD, Door, U3 Gray Lexan Flap Glass, CN 10 Compliant 1 REV SHOP NOTE: Must use M1 latches for CN 10 certification. 05-14-4650 MD, Doors, L3.5, Gray Poly carbonate Slider, CN 10 Compliant 1 REV STREETSIDE REAR AREA#4 1 REV 05-15-5051 > MD, Cabinet U4, Combined with U3.5 1 REV 05-15-5051 X < Cabinet C4 Custom 1 SHOP NOTE: SR SAP# 10168440) Prev SR 220147F Ref 525251 12/05/2021 11-01:01 Pane 12 PART NO S DESCRIPTIONQTY ID Combine C4 and C3 cabinets into a single cabinet, CN 10. Single divider centered in cabinet with a shelf on each side of cabinet. 05-15-5118 MD, Cabinet L4, Deleted 1 REV CABINET DOORS 1 REV 05-15-6112 MD, Doors, U4/U3.5 Combined, Gray Poly carbonate Slider-CN 10 Compliant 1 REV SQUAD BENCH AREA 1 REV 05-16-0066 S < >WC, Squad Bench, Custom 1 REV SHOP NOTE: SR# Custom SB (SAP# 10522452) SR220147F Ref 357921 Recessed vertical style D cylinder storage to fit (2) Cylinder, Single, Zico QR -2 Strapless, No waste Decrease depth of seat cushion 2 inches so it doesn't hit restraints on cs wall. Install lid strut to allow lid to open 05-16-0070 MD, Lid, Squad Bench, Single, No Bio-Waste 1 REV 05-16-0080 MD, Handle, Trimark, CPR Seat, Std. 1 REV 05-16-0082 MD, Handle, Trimark, Squad Bench, STD 1 REV 05-16-0088 X < Bolt, Barrell, Installed 1 SHOP NOTE: Installed on AA writing tray, to keep tray in closed position. 05-16-0094 MD, Strut, Gas, 30 LB, Installed 1 REV 05-16-0214 < MD, Seatbelt, Assy, (4 Point), Per Wax, Black, Vert. Mount, (1) Each, CN-8 1 REV SHOP NOTE: Above bench Lid mounting (1)for CPR side seat (Delete shop note if not required) (2)for squad Bench 05-16-0214 < MD, Seatbelt, Assy, (4 Point), Per Wax, Black, Vert. Mount, (1) Each, CN-8 2 REV SHOP NOTE: Above bench Lid mounting (1) for CPR side seat (Delete shop note if not required) (2)for squad Bench 05-16-0222 MD, Patient Restraint Belts, Squad Bench (3) 1 REV 05-16-9909 X < MD,CS Splint, 7 in deep, 2 Sect Gray 1 SHOP NOTE: Note: TO meet KKK requirement for space between cushion on squad bench and bottom of splint cabinet. Gray Lexan Flap glass with Spring hinge hold open and one plunger latches to hold closed. Must use (2) M1 latches on each door for CN 10 certification < CURBSIDE REAR 1 REV SHOP NOTE: Eng note Dump switch is RELOCATED to RR entry door 05-16-9923 < MD, Cabinet, Curbside Rear, Standard 1 REV SHOP NOTE: Eng note Dump switch is RELOCATED to RR entry door 05-17-2508 < > MD, Cabinet, Glove Box Holder, (3), Above C/S door, 1 REV SHOP NOTE: 12/05/2021 11:01:01 Pa a 13 PART NO S DESCRIPTIONQTY ID Must use M1 latches for KKK Change notice 10 compliance < CURBSIDE RIGHT STACK STORAGE#8 1 REV SHOP NOTE: Engineering same as 525251 Eng note customer requires reference drawing of RF cabinet for approval on this unit Austin Gen 2 doors will close over dealer installed knox box, decrease depth of knox cab and leave the back open, close out will be 2 inches deeper than the depth of the knox box, space behind this close out will be used for storage. 05-18-0055 MD, RF ALS, Split Upper/Lower w/Ctr drawer, HVAC Relocated 1 REV 05-18-OOSR X < RF#8 Custom 1 SHOP NOTE: SR# Custom RFC Interior 8 (SAP#10522451) SR220147F Same as 357921 U8 Inside access only(upper) Drawer center section L8 ISOS access (Lower) Eng note close out bottom left area of U8 at wall 1 for a dealer installed knox box ini no flange and recessed ENGINEERING Same as 357921 Note set Knox box cabinet back, Austin Gen 2 doors will close over Knox b x, decrease depth of cab, and leave the back open, close out will be 2 inches deeper than the depth of the knox box, space behind this close out will be used for storage, 05-18-5158 MD, Doors, RF, U8, Dual Gen II OHO, Poly carbonate Doors, Gray 1 REV 05-18-5216 < MD, RF ALS, C8 Center Drawer, 6" high x Full width x 22"D 1 REV SHOP NOTE: Metal Drawer with Solid Face for maximum drawer space 05-18-5354 MD, Doors, RF, L8, Dual Gen II OHO, Poly carbonate Doors, Gray 1 REV ATTENDANT SEAT 1 REV 05-19-6902 < MD, Attendant's Seat, EVS 1880,Comfort, Hi-Back Child Safety w/Per4Max 1 REV SHOP NOTE: Locate seat exactly as 525251 05-19-6904 > MD, Color, Gunmetal, Per4Max Belt, Black 1 REV 05-19-7215 < > MD, Attendant's Seat Base, EVS CBS Box Style 1 REV SHOP NOTE: Box opening to be toward Bulk head cabinet ILOS INTERIOR COLORS 1 REV 05-20-0075 MD, Mica, Dove Gray Over Pewter Brush (Matte) 1 REV UPHOLSTERY 1 REV 05-20-5918 < > MD, Upholstery Color, Gunmetal 1 REV SHOP NOTE: Prod/Eng note decrease depth of squad bench seat cushion by 2 inches, so lid will fully open and seat cushion doesn't hit restraints 05-20-5970 > WC, Backrest Cushion, EVS, Gunmetal,w/WC Logo, Each 3 REV 05-21-2028 < MD, Divider,Vertical, Streetside Upper Cab, Each 1 REV SHOP NOTE: Between C4/C3 combo Centered 12/05/2021 11:01:01 Pane 14 PART NO S DESCRIPTIONCITY ID CABINET KICK PANELS 1 REV 05-21-5106 < MD, Kick plate, Full Height Brushed Stainless Steel, Squad Bench 1 REV SHOP NOTE: to the bottom of the S/B Lid 05-21-5108 MD, Kick plate, 8"Brushed S/S, On Face of Base wall 1 REV CABINET LATCHES-INTERIOR 1 REV 05-21-8196 X < Handle ,C Pull Installed 1 SHOP NOTE: AA tray 05-21-8213 < > MD, Latch, Southco M1, 2"S/S, (3/4" door) Non-Locking, CN 10-Rated 10lb 2 REV SHOP NOTE: (self latching) Flush Mount. Non-Locking RF Cabinet Door Cabinet L3.5 drop down door 05-21-8219 < > MD, Latch, Southco M1, 2"S/S, (3/8" Door) Non-Locking, CN 10-Rated 101b 5 REV SHOP NOTE: (self latching) Flush Mount. Non-Locking (2) GB cabt(1) U3 (1)each CS Upper Cabs < GENERAL WIRING 1 REV SHOP NOTE: Reference only 525251 06-01-0130 MD, Electrical System: Printed Circuitboard 1 REV 06-01-0250 MD, Vanner, "E"Spec, PC Board, No LB 1 REV 06-06-12SR X < Back Up Camera 1 SHOP NOTE: SR# BU Camera (SAP# 10184826) SR 220147F make sure mirror bracket fits on a 2022 F550 Mount camera exterior on rear of module, off center, toward drivers side, above rear entry door (1)#HC430RVM rearview mirror with 4.3" integral monitor (1)#IR250 Camera, BLACK, with 35'of cable COMMUNICATION 1 REV 06-06-5538 < > MD, Coax Cable, RG58/U, Each,Terminate: 2 REV SHOP NOTE: (1) - From module roof Dome#3 to behind passenger seat with 6'pigtails (1)- From module roof port Dome#7 to behind the passenger seat Standard - with 6' pigtails 06-06-55SR X < Custom Antennas Package Installed 1 SHOP NOTE: SR# Custom Antennas Package Installed (SO-ANT-351178) BOM Eng Ref co Je 10184762 SR220147F Ref 357921 (2) Laird A150S VHF ant with spring plus associated nmo mount (1) Dome 6 to terminate at the CB (Tag Elgin#3) (1) Dome 1 to terminate at the CB (Tag Elgin#6) (1) Laird 4503 (1) Dome 4 to terminate at the CB (Tag Elgin#4) Laird TRA7603 UHF 3db low profile antenna plus associateed nmo mount instal ed 12/05/2021 11:01:01 Pa pp 15 PART NO S DESCRIPTION ILOS- Laird TRA4503: 450-470 Phantom Antenna, White RF Cable with NMOK Motorola Style roof connector 06-06-56SR X < Additional NEW Antenna 1 SHOP NOTE: (SAP# 10523273) (1) Centered on module roof,just rearward of HVAC unit, accessed at absolute forward of wire trough. Terminate tails at CB cab. Tag Elgin#2 AP-CCWG-Q-S2222-RP3-BL 06-07-6604 < > MD, Clock,Analog, Self Cont, 12/24 Hr, 8" 1 REV SHOP NOTE: LOCATION: CSR cabinet see ref drawing 07-00-0610 < MD, Light, in Circuit Board Area, for Electrical Troubleshooting 1 REV SHOP NOTE: -with integral switch; wired constant hot. POWER SOURCES 1 REV 07-01-1002 < MD, Power Source, 12VDC, 20A, Ignition/Shoreline Hot 1 REV SHOP NOTE: 20amp 12 volt DC circuit ran to two locations, (1) pre-wire coil and tagged in aeon area and (1) pre-wire coil and tagged behind driver's seat. 07-01-1004 < > MD, Power Source,12 VDC,15 Amp(+-), Constant Hot 2 REV SHOP NOTE: Termination: (1) Constant Hot to cab console (2) Constant Hot to circuit board (1) Constant hot to behind AA SW panel (1) Constant Hot to RF cabt U8 knox box cabinet 07-01-1008 < > MD, Power Source, 12 VDC, 15 Amp(+_), Ignition Hot 5 REV SHOP NOTE: (1) Ignition hot, terminating in cab console (1) Ignition Hot to behind AA SW panel 07-01-1010 < > MD, Power Source, 12 VDC, 20 Amp (+-), Constant Hot 1 REV SHOP NOTE: Termination: cab console 07-01-1016 < > MD, Power Source, 12 VDC, 30 Amp(+_) Constant Hot 2 REV SHOP NOTE: -Constant Hot, to terminate in the circuit board -with 6 foot tails (hot and ground). VOLTMETER 1 REV 07-02-1150 < WC, Voltmeter, Analog, F1 1 REV SHOP NOTE: On center console SWITCH panel 12/05/2021 11:01:02 Pa a 16 PART NO S DESCRIPTION 07-02-1155 < MD, Alarm, Low Voltage,Audio/Visual 1 REV SHOP NOTE: Light in cab console and Buzzer in cab. BATTERY SYSTEM 1 REV 07-04-8723 < > MD, Battery Sw, 5min Timer, F1, Fig 5B, (2) OEM Batt, (2) in RF 1 REV SHOP NOTE: (SO-BATT-351178) Elec Eng note same as 357921 Timer ILOS set up per Elec Eng for check out lights only. Batt sw will be ign only ! (2) Batteries under hood. (1) Delco 1150 in RF batt compt on a tray IATS, note see battery charger also. BATTERIES 1 REV 07-05-0919 < MD, Battery, Delco, 1150, Each 1 REV SHOP NOTE: Lower RF compt 07-09-1023 < > MD, Battery Charger, Kussmaul, Auto 1200, 40 amp w/remote Ind. Light 1 REV SHOP NOTE: BOM Eng check BOM MOUNTED IN BATTERY COMPT as in previous 525251 Charger/Conditioner mounted in comp #2 with the indicator light above the shorel ne inlet Circuit breaker for the charger wiring MUST be 80 amp inline. Kussmaul remote indicator panel installed next to SL inlet above 2 (wired per E EC ENG80 amp breaker) 07-10-1101 < > MD, Outlet, Power Point Style, (2),A/A 1 REV SHOP NOTE: -on standard 20-amp ignition hot circuit. ("elect battery switch") 07-10-1105 < > MD, Outlet, Power Point Style, Each 1 REV SHOP NOTE: Constant hot, RF Cabinet U8 Wall 2 up high and to the right 07-10-1109 < MD, Power Outlet, Kussmaul, USB Dual Port, 5VDC,4.8 Amp, switch panel 1 REV SHOP NOTE: Located in the cab switch panel per Electrical Engineering 07-10-1111 < MD, Power Outlet, Kussmaul, USB Dual Port, 5VDC,4.8 Amp, switch panel, Each 1 REV SHOP NOTE: Location in the Action area outlet panel. FRONT CONSOLE 1 REV 08-01-3525 < WC, Console, Drivers Switch & Radio, Center,Aluminum, Black,Type1 Ford 1 REV SHOP NOTE: Elec Eng note provide panel layouts for customer's file Eng note same as 357921 Black polyurethane coated .125 Aluminum See below for Optional panels 10.75 x 12.5 x 7" deep storage area at rear 08-01-3650 MD, Map Pocket Below Pass Thru, Type 1 1 REV 12/05/2021 11:01:02 Pa a 17 PART NO S DESCRIPTIONCITY ID 08-01-4652 > WC, Single Blank Panel 1 REV 08-01-4654 >WC, Double Blank Panel 1 REV 08-01-4660 >WC, Cup Holder Panel (No Handle Notch) 1 REV 08-01-4666 WC, Flat Switch Panel 1 REV 08-02-0006 < MD, Module Electrical Panels, Brushed Stainless Steel 1 REV SHOP NOTE: brushed stainless steel panels for the Outlet panels, switch panels and ob er faceplates in the MODULE only. ATTENDANT CONTROL PANEL 1 REV 08-03-0306 < WC, Console, A/A, Wood,Angled 1 REV SHOP NOTE: Eng Note reference only 488594 CM5000 thermostat. Top row 3 switches & 1 blank. Bottom row 2 switches, USB and 1 blank only 08-04-6105 X < MD, Switch, 12VDC, Rocker Amber, Additional 1 SHOP NOTE: CAB CONSOLE 10 amp constant hot Additional switch in cab console, terminate wires in CB cabt w/ 6' tail, tag wire ir CB cabt Wi-Fi 08-04-6109 X < MD, 3-way Switch, Dome Master Circuit 1 SHOP NOTE: DOME MASTER (1) switch in CC (1) svvitch in AA 08-04-6111 < > MD, Switch, Momentary, Rocker, (1) 3 REV SHOP NOTE: CC Switch panel driver and passenger side, (Air Horns)same as 525251 In AA Lower panel to activate 15 minute check out timer IATS, to allow activation and de-activation, Wire to all dome lights in liner-High intensity SIREN ELECTRONIC -CONTROL HEADS/AMPS 1 REV 09-03-1802 > MD, Siren, Whelen, WS-295-SLSA1 1 REV < SIREN SPEAKERS 1 REV SHOP NOTE: NO LINEX ON SPEAKERS 09-03-2708 < WC, Siren Speakers, Cast SAD/PSAD3827-20FSD-1, F-Series 2020 1 REV SHOP NOTE: Thru Front Bumper DO NOT Line X !!!! < AIR HORNS 1 REV SHOP NOTE: DO NOT LINEX TRUMPETS 09-03-3502 > MD,Additional,Air Tank, For Buell Air Horns 1 REV 09-03-3510 < > MD,Air Horn, Buell, 5440 comp, 10 & 12 inch horns 1 REV SHOP NOTE: mount compressor on fixed shelf in compt"E" 09-03-3522 < > MD, Brackets,Air horn Under Front Bumper, F-Series, 2017+ 1 REV SHOP NOTE: 12/05/2021 11:01:02 Pa a 18 PART NO • • Brackets Per Eng design ID Under front bumper through plastic fairing. 09-03-3530 MD, Switch, Siren/Horn Thru Horn Ring 1 REV BACK-UP ALARMS 1 REV 09-05-1116 > MD, Back-Up Alarm, w/Cutoff, Auto Reset 1 REV < EMERGENCY SEQUENCER/LOAD MANAGER 1 REV SHOP NOTE: ENG NOTE: Same as 525251 09-06-0026 < > MD, Emergency Sequencer, Kussmaul, Load Manager,w/Switch 1 REV SHOP NOTE: Eng ref 525251 W/Sequencer switch and override on console TRAFFIC MANAGEMENT LIGHTS 1 REV 09-44-01SR X < Whelen TANF85 Traffic Advisor 1 SHOP NOTE: SR# Whelen TANF85 8-lamp linear-LED Traffic Advisor, approx. 46.75" long. TACT D1 control head (SO-TA-351178) Prev. SR 220147F Same as 525251 Mounted above load lights Mount control head in cab console per engineering 09-44-02SR X < Spotlight, Go Light, Black, #2021 1 SHOP NOTE: SR# Go Light(SO-GOLT-351032) SR 220147F Mount Go Light in cab roof -centered. Toggle control to be in CC switch panel at top close to passenger 09-70-5247 < > MD, Traffic Pre-Empt, Tomar, T792HL-R 1 REV SHOP NOTE: wire the power supply to the parking brake to disable the system when the park g brake is set-system wired to switch in front console labeled: PRE-EM Chrome Bezel Cool Bar Center above 7L Clear PRI ONLY WARNING LIGHT FLASHERS 1 REV 09-80-2006 < > MD, Flasher, Whelen AFM-560 1 REV SHOP NOTE: Set flash pattern to Comet Flash unless otherwise specified. 09-80-5920 > MD, Circuit, Neutral Power 1 REV 09-80-7009 < MD, Brake Override Circuit 1 REV SHOP NOTE: (Must use IATS Stop/tail lights with this option) Rear Window lower red same as 525251 09-80-7011 < > MD, Automatic Secondary, Park/Neutral,w/Momentary Switch, Auto Reset 1 REV SHOP NOTE: the circuit would automatically reset when the gear shift lever is placed back into g ar. 12/05/2021 11:01:02 Pane 19 PART NO S DESCRIPTIONQTY ID WARNING LIGHTS 1 REV LED Series-900(Flange Separate) 1 REV 09-95-1375 < > MD, Light,Whelen 900 LED, Red, Red Lens, 90RR5SRR, External Flasher 12 REV SHOP NOTE: (2) Each side standard locations (2) Front Module upper outer corners (2) Rear Module upper outer corners (2)to show thru lower rear windows (2) Cool Bar one each side of center clear PRI/SEC thru AFM560 09-95-1381 < > MD, Light,Whelen 900 LED,Amber, Amber Lens, 90AA5SAR, External Flasher 2 REV SHOP NOTE: (1)CS upper rear window show thru (1) SS upper rear window show thru 09-95-1389 < > MD, Light,Whelen 900 LED, R/C, Clear Lens, 90RC5SCR, External Flasher 2 REV SHOP NOTE: (2) Cool Bar angled pods PRI ONLY NFPA thru AFM 560 09-95-1430 MD, Flange, Super 900 LED, #90FLANGC 16 REV LED Series -700(Flange Separate) 1 REV 09-95-2334 < > MD, Light, Whelen 700 LED, Red, Red Lens, 70R02FRR 4 REV SHOP NOTE: (2) as front intersection lights. (1) Each over rear wheels PRI Only NFPA thru AFM 560 09-95-2346 < > MD, Light, Whelen 700 LED, Clear LED, 70CO2FCR 1 REV SHOP NOTE: Center Clear on Cool bar under Tomar PRI ONLY-NFPA thru AFM 560 09-95-3004 < MD, Flange, Whelen, For 7E lights(1), Mods 5 REV SHOP NOTE: -For 7 Series Lights Whelen 500 Series Super-LEDO(Flange Separate) 1 REV 09-95-4247 < > MD, Light, 5L TIR6, Whelen, Red, Red Lens, 50RR3ZRR 3 REV SHOP NOTE: (3) Installed on the Rear and CS entry door interior panels, lower outer corners Wired Ignition Hot, to flash when door is open, thru internal flasher, factory default. 09-95-4259 < > MD, Light, 5L LIN6, Whelen, Red, Red Lens, 50R02ZRR 2 REV SHOP NOTE: (2) as grille lights wired thru AFM560 flasher Prim Only Shut down in Park/Neutral 09-95-4311 > MD, Housing, 5L Series, #5LSMAC, (1) 3 REV WHELEN LINZ6 1 REV 09-95-4802 < MD, Light, Whelen, LINZ6R, LED-Red 2 REV SHOP NOTE: with chrome flanges 12/05/2021 11:01:02 Pa a 20 PART NO S DESCRIPTIONQTY ID (2)front intersectors PRI ONLY NFPA internal flasher 09-95-9393 MD, Housings, Cast, 500 Series, Upper Grille, Ford, 2020 F series, Pair 1 REV < EXTERIOR AUTOMOTIVE LIGHTING 1 REV SHOP NOTE: No LINEX 10-01-0040 < WC, Taillights, Whelen, LED Stop/Tail, Halogen Backup, w/WC logo 1 REV SHOP NOTE: - Brake-Steady Burn -Turn Arrow—sequential arrow No Line X !!! ICC/MARKER LIGHTS 1 REV 10-01-2177 < MD, Light, Clearance,Amber LED, Each 3 REV SHOP NOTE: On front as clearance lights. 10-01-2178 < MD, Light, Clearance, Red LED, Each 3 REV SHOP NOTE: On rear as clearance lights. 10-01-2255 < WC, Corner Cap Lts, Multi, LED, (2)Amber(2) Red w/Flashers, No switch 1 REV SHOP NOTE: -High intensity flashers; thru Primary/Secondary FLOOD AND LOAD SYSTEMS 1 REV 10-02-2214 < > MD, Light, Whelen, 700 Series, 12LED, Scene Light 2 REV SHOP NOTE: Rear Loads under the traffic advisor. See drawings 10-02-2232 < MD, Light, LED, Whelen, Clear, #9SCOENZR, 24 LED,w/Chrome Flange 4 REV SHOP NOTE: (new code) (2) each side as scene lights 10-02-2242 MD, Scene Lighting,All to Activate w/Reverse Gear 1 REV 10-02-2250 MD, Scene Lighting, CS,Activate on Opening of Entry Door 1 REV 10-02-8043 < > MD, Lights, Running Board, Pair,Trucklite 4" LED, Constant Hot 1 REV SHOP NOTE: Light placed upward to avoid obstruction from running board flange!!! Ref 525251. Activated with the cab doors. Activated with the cab doors. < 11 -INTERIOR LIGHTING 1 REV SHOP NOTE: ELEC ENGINEERING NOTE 1 HI-Off-Low switch in AA panel to turn all liner dome lights on and off! Same as 525251 11-01-2809 < MD, Lights, Dome, LED, Whelen, White Fing, (4) S/S, (3)C/S 1 REV SHOP NOTE: NOTE: NO VISABLE FASTENERS OR HOLES. 12/05/2021 11:01:02 Pa a 21 PART NO S DESCRIPTIONQTY ID 11-01-2818 < MD, Light, Dome, LED,Whelen, White Fing, (1)Additional 3 REV SHOP NOTE: Location F/G/H NOTE: NO VISABLE FASTENERS OR HOLES. 11-01-2871 WC, No Lighting Recessed into Trough Cover 1 REV 11-01-9032 < > MD, Timer, Momentary Switch, 15 Minute, Constant Hot 1 REV SHOP NOTE: (must have ECX timed battery switch with this option) Mount switch on C/S wall at the head of the squad bench in the standard location. Switch to allow activation and also deactivation. Wire to Streetside Domes in liner on High. SPOTLIGHTS/HANDHELD LIGHTS 1 REV 11-02-1003 MD, Handheld Spotlight-Sho-Me 200,000 CP 1 REV ATTENDANT LIGHT 1 REV 11-03-2031 < MD, Light, Intertek ZY-PIR38 12v, LED, Each 1 REV SHOP NOTE: Install on bottom of L cabinets!!! 12 -ELECTRICAL 125 VOLT AC 1 REV SHORELINE INLET 1 REV 12-01-9114 < > MD, Shoreline, 20A, Super Auto Eject, Red 1 REV SHOP NOTE: -with red cover; mounted above comp"#2" Elec Eng note relocate GFI breaker box to Compt 2, on wall 1 of compt, up h gh above electrical shelf, toward outer edge of shelf for easy access, trim electric ovelflow cage so the customer can reset breaker easily if needed. OUTLETS-125VAC 1 REV 12-02-2110 < MD, Outlets, 125 VAC, Duplex, (1)Action Wall, (1) Right Front Cabinet 1 REV SHOP NOTE: -(1) outlet in action area - (1)outlet in the RF Cabinet"U8", wall#2, upper right. 12-02-2114 < > MD, Outlet, 125 VAC, Duplex, Each, State Location: 1 REV SHOP NOTE: -telemetry area, wall#2. Low Note: 125V outlet horizontal ILOS same as 525251 BLOCKHEATERS 1 REV 12-02-4001 < Block Heater-With OEM Plug 1 REV SHOP NOTE: This option does not include a switch. (STANDARD). INVERTER-125VAC 1 REV AUXILIARY ENVIRONMENTAL SYSTEMS 1 REV 13-02-0111 MD, Exhaust Fan, Single 12V, in Line Blower 1 REV WHEELED COACH HVAC UNITS 1 REV 13-02-5751 > MD, Hoses, Heater, No Max, to Rear 1 REV 13-02-5763 < > WC, Heat/AC, F1, Combo,w/Coolbar 1 REV SHOP NOTE: (new code) 12/05/2021 11:01:02 Page 22 PART NO S DESCRIPTIONQTY ID with thermostat in action area. 12vdc External Condenser, in Coolbar mounted on front of module. Painted to match front of module. Note: pick warning lights separately !! 13-02-6028 WC, Air Conditioning Face Plate, Brushed Stainless Steel with Logo 1 REV 13-02-6052 < > MD, Heat/AC Re-Located Center over WT/PT 1 REV SHOP NOTE: HVAC evaporator relocated to front bulkhead above the pass thru/walk Thru 13-02-6082 > MD, Generation I, Steel Cool Bar cover 1 REV 13-02-7754 < MD, Thermostat, Hoseline Master Control Digital CM5000 1 REV SHOP NOTE: With cover over standard switch location. Mount probe in front of evaporator 13-02-SR01 X < Splash/Cover over Elec Heater valves 1 SHOP NOTE: SR# (SO-CVR-351178) Prev SR 218065F Same as 357921 A cover made out of aluminum to protect elec heater valves/solenoids under module, customer requirement COT MOUNTING PROVISIONS 1 REV Cot Mounts 1 REV 14-01-1546 < MD, Cot Mount, Stryker Power Load, No Wheel Guides, CN 8 Compliant 1 REV SHOP NOTE: includes constant hot power supply for battery charging. 14-01-4028 < Center Mount 1 REV SHOP NOTE: Eng ref 525251 OXYGEN AND AIR SYSTEMS 1 REV 14-02-1010 < > MD, 02 Cylinder Wrench ,Tethered 1 REV SHOP NOTE: in oxygen comp. 14-02-2242 < MD, 02 Cylinder Bracket, Multiversal, #QR-MV, W/Straps 1 REV SHOP NOTE: (Uni-strut track mounting is now std) Specify 02 bottle size. 14-02-2244 MD, Track, Unistrut for Oxygen Rack 1 REV 14-02-3005 MD, Manual, 02 System 1 REV 14-02-3156 < MD, 02 Regulator, Preset 50 PSI 1 REV SHOP NOTE: Ship Loose unless otherwise directed 14-02-4153 < > MD, 02 Outlets, Ohio Style(2 in Action Area, 1 CS Wall) 1 REV SHOP NOTE: SEE REF DRAWING AA Layout 02-02-VAC (vac port close to suction container.) Reference only 525251 12/05/2021 11:01:02 Page 23 PART NO S DESCRIPTION QTY ID (2) in Action Area, (1) CS wall above squad bench 14-02-4920 > MD, Lexan Flap,w/Hinge 1 7REV14-02-6282 < > MD, 02 Cylinder Holder, Single, Zico QR-D-2 Strapless, CN 10 Certified 2 SHOP NOTE: (2) Mounted at head of bench in recessed cabinet 14-02-9045 < > MD,Bracket, SCBA, Zico, UN-6-30-3-F-CRS, Each 3 REV SHOP NOTE: Compartment 4 on corner brackets and 1 centered on wall 2 down low. REF 52525 See reference pic on server in wo folder SUCTION SYSTEM 1 REV 14-03-3000 < WC, Suction Outlet and Container Relocated to Face of A/A 1 REV SHOP NOTE: Relocate forward in AA to under the AA switch panel, see drawings for reference (1) vacuum port in action area (Down low close to suction container see ref drawing) 14-03-3030 MD, Suction Pump, SSCOR 90206 1 REV 14-03-3045 > MD, Suction Port 1 REV 14-03-3070 < > MD, Suction System, SSCOR 23002 Disposable w/Canister Clip& Regulator 1 REV SHOP NOTE: NO Ohio style vacuum outlet - plumb hose from SSCOR canister through hole in AA wall panel Meets SAE J3043 Requirements Relocate forward in AA to under the AA switch panel, see drawings for reference. MISC MEDICAL 1 REV 14-04-1200 < > MD, Fire Extinguisher, 5#ABC with Surface Mount Brkt., Each 2 REV SHOP NOTE: HD Amerex Bracket#861 H with Amerex 5LB fire extinguisher. 14-04-12SR X < Ferno DFIB Mount 1 SHOP NOTE: SR# Ferno DF1B Mount(SAP#10523254) Prev SR21837OF REF 525251 Rearward end of AA mount per customer ref drawing with measurements on serve in work order folder. Also see ref pics < PAINT AND FINISH 1 REV SHOP NOTE: See (SO-PT-351178) Same as 525251 Pt Code Red#FRE 3015 (5)Wheels, Outer's and SPARE tire. (Both sides of Rim) Black poiyurea CS entry door jamb ILOS call extension 285 for information if needed, Line X needs to cover at CS entry door to the bottom edge of the CS skin. In house Black Poly urea/Line X Black-out front bumper. Running Boards, Stone Guards, corner caps,Kick plate,front stone guards, License plate holder,fuel fill plates (2)fuel fill housing's, rear bumper. 15-00-0200 WC, Wheeled Coach Paint Process 1 REV 15-01-2010 < > Module Paint, Single Color, Paint other than OEM, Other than Red or Metallic 1 REV SHOP NOTE: 12/05/2021 11:01:02 Pa a 24 PART NO • • Same as 525251 ID Color RED Sikkens paint Code#FRE3015 Module Roof and Drip Rail OEM White FA91:YZ Ref pies on server in wo folder Note: Must state color with paint code and request a paint spray-out for approval. NOTE: When requesting a dark module color, REV Group Orlando recommen s option 15-01-4010 to paint the roof sheet White. This will reduce heat transfer into the module and increase A/C system efficiency. 15-01-4010 < Module Paint, Flat Portion of Roof to be Painted White 1 REV SHOP NOTE: Ford white: FA91:YZ Module Roof and Drip Rail OEM White FA91:YZ 15-01-5500 < Cab Paint-Single Color, Repaint other than OEM, Other than Red or Metallic 1 REV SHOP NOTE: Same as 4885941 Color RED Sikkens paint Code#FRE3015 Note: Must state color with paint code and request a paint spray-out for approval. < PAINT STRIPING DESIGN 1 REV SHOP NOTE:. Note Door Panel Chevron SR previously in build. 15-02-1200 Paint Belt, None 1 REV 15-02-8013 X Rear Chevron to be installed by dealer Fire Service 1 DECALS AND NOMENCLATURE 1 REV 15-05-0038 WC, Ship Loose, W.C. Standard Items 1 REV 15-05-0047 > MD, Bracket, Spare Tire Mounting, Ship Loose 1 REV 15-05-0055 > MD, Spare Tire, OEM only, Ship Loose 1 REV 15-05-OOSR X < Ship Loose Sharps 1 SHOP NOTE: SR# Ship Loose Sharps (SO-SL-351178) SR 220147F Same as 357921 Armstrong Medical 5 qt Sharps disposal & mounting bracket. Boundtree#298507 3A 5-Quart transparent red sharps container&#298516 wall enclosure with lock 74-09-0099 < Indemnification Statement 1 REV SHOP NOTE: The purchaser agrees to defend, indemnify and hold Rev Ambulance Grotip harmless from any claims, costs (including actual attorneys' fees), damages and liabilities caused in whole or in part by any alteration or modification of, or changes or additions to the purchased products OR use of product for purposes it was riot designed or intended for. End Of Order 1 REV _= Factory Ship Loose-EMS Equipment-1.017 11/12/21 == 1 REV