Loading...
HomeMy WebLinkAbout20-22 Resolution No. 20-22 RESOLUTION AUTHORIZING EXECUTION OF A PURCHASE AGREEMENT WITH FIRE SERVICE, INC. FOR THE PURCHASE OF A WHEELED COACH FIRE AMBULANCE BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN,ILLINOIS,that pursuant to Elgin Municipal Code Section 5.02.020B(9) the City Council hereby finds that an exception to the requirements of the procurement ordinance is necessary and in the best interest of the city; and BE IT FURTHER RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN, ILLINOIS, that Richard G. Kozal, City Manager, and Kimberly A. Dewis, City Clerk, be and are hereby authorized and directed to execute a Purchase Agreement on behalf of the City of Elgin with Fire Service,Inc., for the purchase of a Wheeled Coach fire ambulance, a copy of which is attached hereto and made a part hereof by reference. s/David J. Kaptain David J. Kaptain, Mayor Presented: February 26, 2020 Adopted: February 26, 2020 Omnibus Vote: Yeas: 7 Nays: 0 Attest: s/Kimberly Dewis Kimberly Dewis, City Clerk PURCHASE AGREEMENT This Agreement is hereby made and entered into this 26th day of February , 2020, by and between the City of Elgin, Illinois, a municipal corporation (herein referred to as "City") and Fire Service, Inc., an Indiana corporation, (herein referred to as "Fire" or"Seller"). NOW THEREFORE, for and in consideration of the mutual promises and covenants contained herein, the sufficiency of which is hereby mutually acknowledged, the parties hereto hereby agree as follows: 1. PURCHASE. City shall purchase, and Fire shall sell the goods described by Attachment A attached hereto and made a part hereof; and as described in the Wheeled Coach specifications attached hereto and made a part hereof as Attachment B, pursuant to the contract between the City and Fire dated March 7, 2018,attached hereto and made a part hereof. 2. TERMS. This agreement shall be subject to the terms and conditions contained herein and as provided by Attachments A, B and C. 3. CONFLICT. In the event of any conflict between any of the terms and provisions of this purchase agreement and any Attachment hereto, the terms and provisions of this purchase agreement shall control. In the event of any conflict between Attachments A and C hereto, Attachment A shall control. In the event of any conflict between Attachments A and B hereto, Attachment A shall control. 4. LAW/VENUE. This agreement is subject to and governed by the laws of the State of Illinois. Venue for the resolution of any disputes or the enforcement of any rights arising out of or in connection with this agreement shall be the Circuit Court of Kane County, Illinois,without jury. SEC hereby irrevocably consents to the jurisdiction of the Circuit Court of Kane County, Illinois for the enforcement of any rights, the resolution of any disputes and/or for the purposes of any lawsuit brought pursuant to this agreement or the subject matter hereof;and Fire agrees that service by first class U.S. mail to Jeff LeBeda, agent of Fire Service, Inc., 9545 North Industrial Drive, Saint John, Indiana 46373 shall constitute effective service. 5. NO MODIFICATION. There shall be no modification of this agreement, except in writing and executed with the same formalities as the original. 6. MERGER. This agreement embodies the whole agreement of the parties. There are no promises, terms, conditions, or obligations other than those contained herein, and this agreement shall supersede all previous communications,representations,or agreements,either verbal,written or implied between the parties hereto. 7. INTEREST. Fire hereby waives any and all claims or rights to interest on money claimed to be due pursuant to this agreement, and waives any and all such rights to interest to which it may otherwise be entitled, pursuant to law, including, but not limited to, pursuant to the Local Government Prompt Payment Act(50 ILCS 505/1, et seq.) as amended or the Illinois Interest Act (815 ILCS 205/1 et seq.)as amended.The provisions of this paragraph shall survive any expiration, completion, and/or termination of this agreement. • 8. SEVERABILITY. The terms of this agreement shall be severable. In the event any of the terms or the provisions of this agreement are deemed to be void or otherwise unenforceable for any reason, the remainder of this agreement shall remain in full force and effect. 9. COMPLIANCE WITH LAW. Notwithstanding any other provision of this agreement it is expressly agreed and understood that in connection with the performance of this agreement, Fire shall comply with all applicable, federal, state, city and other requirements of law, including, but not limited to, any applicable requirements regarding prevailing wages, minimum wage, workplace safety and legal status of employees. Without limiting the foregoing, Fire hereby certifies, represents, and warrants to City that all of Fire's employees and/or agents who will be providing products and/or services with respect to this agreement shall be legally authorized to work in the United States. Fire shall also at its expense secure all permits and licenses, pay all charges and fees, and give all notices necessary and incident to the due and lawful prosecution of the work, and/or the products and/or services to be provided for in this agreement. City shall have the right to audit any records in the possession or control of Fire to determine Fire's compliance with the provisions of this section. In the event City proceeds with such an audit, Fire shall make available to City, Fire's relevant records at no cost to City. City shall pay any and all costs associated with any such audit. 10. PAYMENT. City shall pay ($259,118.00) Two Hundred Fifty-Nine Thousand, One Hundred Eighteen and 00/100 dollars or($259,118.00) pursuant to Attachment A within thirty (30)days of delivery or City's receipt of invoice. The aforementioned total sum is inclusive of all freight, shipping and applicable taxes, which shall be at Fire's sole expense. Fire shall accept in trade one (1) 2011 Wheeled Coach F450 Type 1 ambulance # 1FDUF4HTXBED05979, with 95,510 miles at evaluation for the value of $8,500.00. The aforementioned ambulance must be in the same operating and physical condition as was on the evaluation dated January 21, 2019. If not, the trade is void and the customer is responsible for the trade value to be reimbursed to the Fire. Fire shall provide a pre-payment discount of S1,500.00 if full payment is received within 5 days of the execution of this Agreement. Net totals: Ambulance as proposed $269,118.00 Trade Value ($ 8,500.00) Pre-Pay Discount ($ 1,500.00) Net purchase: 5259,118.00 All prices are less any applicable local,state,or federal taxes which may be applied to the apparatus proposed. 2 NOTE: Payment shall be made only to: Fire Service, Inc. 9545 North Industrial Drive Saint John, Indiana 46373 11. TERMS OF PAYMENT. F.O.B. St.John,IN. Zero down payment,full payment via wire transfer or municipal check. The purchase price payment reflects US dollars and does not include any authorized change orders which, if applicable, shall be paid at time of final inspection and signed acceptance. It is agreed that the ambulance and equipment covered by this contract shall remain the property of Fire and shall not be placed in service until the full contract price has been paid. 12. DELIVERY. Fire shall complete delivery of all goods on or before October 31, 2020. The ambulance shall be ready for delivery within approximately 120-160 calendar days, after the receipt and signed acceptance of this contract,confirmed build order and chassis at the REV Group Orlando Corporate Headquarters, Winter Park, FL. Fire shall not be liable for penalties and / or delays due to strikes, failures to obtain materials, fires, accidents, force majeure, or any other causes beyond the Fire's control. In order to establish a stable design, procurement, and build schedule, City change order cutoff date of eight (8) days from the date of the execution of this contract shall apply. Changes in major components,configuration,or other items that may change the major components or configuration, (e.g.: Chassis, Motor, Transmission, Wheel Base)shall not be allowed after the contract execution date. If inability to obtain exclusive or brand name materials causes completion or delivery problems, Fire shall advise City of said problem.Fire resolves to examine alternative sources of said material. Material substitutions shall be mutually agreed upon by City and Fire. No substitutions shall be made without the execution of a written change order by City. 13. LIMITATION OF DAMAGES. In no event shall City be liable for any monetary damages in excess of the purchase price contemplated by this agreement. In no event shall City be liable for any consequential, special, or punitive damages resulting from loss of profit. 14. EXECUTION. This agreement may be executed in counterparts, each of which shall be an original and all of which shall constitute one and the same agreement. For the purposes of executing this agreement, any signed copy of this agreement transmitted by fax machine or e-mail shall be treated in all manners and respects as an original document. The signature of any party on a copy of this agreement transmitted by fax machine or e-mail shall be considered for these purposes as an original signature and shall have the same legal effect as an original signature. Any such faxed or e-mailed copy of this agreement shall be considered to have the same binding legal effect as an original document. At the request of either party any fax or e-mail copy of this agreement shall be re-executed by the parties in an original form. No party to this agreement shall 3 raise the use of fax machine or e-mail as a defense to this agreement and shall forever waive such defense. 15. TRANSFER OF TITLE/RISK. Transfer of title, and risk of loss shall pass to City upon delivery of the goods. All transportation and delivery shall be at Fire's sole expense. 16. CHANGE ORDERS. Changes to the contract may be requested by City after the execution of the contract according to Section 2 of this document. Changes shall be reviewed for cost and schedule impact by Fire. Changes shall be sequentially numbered. Change Orders shall be prepared by Fire and executed by City. The price of the apparatus shall be adjusted to take into account any Change Orders. Any and all Change Orders may extend the completion and delivery of the ambulance. 17. SPECIFICATIONS. Fire agrees that all material and workmanship in and about this apparatus shall comply with the original Wheeled Coach proposal dated January 9, 2020, duplicating previous build #357921, and as described by Attachment B hereto. (1) Wheeled Coach 2020 F450 Chassis Type I Custom Ambulance per City of Elgin Specifications. 18. WARRANTY. Shall be as proposed in the attached Wheeled Coach specifications. 19. FIRE SERVICE, INC. requires, and City agrees, that the unit shall be inspected and/or delivered within seven (7) days of notice that the unit had been completed. 20. CANCELLATION. This contract is subject to cancellation by City only upon payment to Fire of reasonable cancellation charges, which shall take into account expenses already incurred and commitments made by Fire. This contract, to be binding, must be signed by an officer of Fire Service, Inc. or a person authorized, in writing, by Fire Service, Inc. to do so. 21. TAG-ON / ADDITIONAL ORDERS. At its sole discretion, FIRE may allow the terms of this contract to be extended to both City and similar agencies for the purchase of a similar unit(s) under similar terms for a period of three (3) years from the date of the execution of this contract. Should Fire choose to exercise this option, it shall be permitted to adjust the contract pricing to account for equitable price adjustments associated with the change in the cost of the materials used to produce the unit. Such adjustments will be based upon the Producer Price Index (PPI) for fire trucks and / or heavy transportation equipment or by itemizing price changes expected by Fire from the component vendors. If there are any changes between the unit(s) purchased via this contract and any subsequent orders, those changes must be documented via properly signed and executed change orders, including any necessary price adjustments. If the purchasing agency is not the City, a separate contract will be required to complete the additional purchases. This contract, including its appendices, embodies the entire understanding between the parties relating to the subject matter contained herein and merges all prior discussions and agreements between them. No agent or representative of Fire has authority to make any representations, 4 statements, warranties, or agreements not herein expressed and all modifications of amendments of this agreement, including any appendices, must be in writing signed by an authorized representative of each of the parties hereto. No surety of any performance bond given by Fire to City in connection with this Agreement shall be liable for any obligation of Fire arising under the Standard Warranty. IN WITNESS WHEREOF. City and Fire have caused this contract to be executed by their duly authorized representatives this 26th day of February , 2020 FIRE SERVICE, INC. r CI ; ' GIN l e CCct Print Nal Richard G. Kozal, City Manager ignature pp Attest ig &I (f)/./..64 es>_ 113;4(.4 S City Cl Title F:\Legal Dept\Agreement\Purchase Agreement-Fire Service Inc-1-31-20 5 ATTACHMENT A ftil.t_creiWiteZ 1i . Jeff LeBeda,Vice President of Sales Email:jeff@fireserviceinc.com Website: www.fireserviceinc.com January 9,2020 Office&Mobile: Phone: 630.546.5232 Service: Phone: 800.578.4281 (After hours) Phone: 219.808.2396 Fax: 219.3654090 PARTS: Phone: 800.578.4281 Fax: 219.365.4090 Acting Fire Chief Robb Cagann City of Elgin Fire Department 550 Summit St Elgin,IL 60120 Proposal Chief, Thank you for your continued interest in Fire Service, Inc, and the Wheeled Coach brand of ambulances. As requested,the following is your proposal for a 2020 model year Ford F450 Type 1,Wheeled Coach modular ambulance. Proposal duplicates the previous build#357921. Pricing includes pre-build,final inspection for 4 Elgin members,Stryker Power cot and delivery. This proposal expires February 10,2020. (1) 2020 Ford F450 Wheeled Coach Type I Modular Ambulance $269,118.00* *Tag on Price to 2019 Contract between Elgin and Fire Service, Inc.02/22/2019 Trade Value,2011 Wheeled Coach VIN 1FDUF4HTXBED05979 ($8,500.00) Purchase Price 2020 Ambulance • $260,618.00 • Pre-pay discount(due within 5 days of contract) ($ 1,500.00) Net Purchase with Pre-Pay $259,118.00 Terms: Zero down,full balance at delivery. FOB St.John IN. Delivery Timeline 120-160 days past chassis arrival and confirmation. As always, I am excited to begin the process with your team. Please let me know if you have any questions. Thanks again for your continued business, Ate cep Jeff LeBeda Vice President of Sales, EMS Division Fire Service, Inc.. jeff@fireserviceinc.com 630-546-5232 1 ATTACHMENT B QUOTATION Fire Service Inc. Elgin Fire Department Fire Service, Inc. Robert Cagann Jeff LeBeda 150 Dexter 1 Unit Elgin, IL 60120 SHA, January 28, 2020 Exp. Date: 02/28/2020 Quote No: Elgin New 2020 R3-0001 T1 - 170: 210160 STD Model: Type 1 Ford- 170"Module -#1170F T1 - 170: 0990030STL Ford, F-450,193"WB,4x4, XLT,170", #1170F T1 - 170: 200011 STD Type 1 Ford - 170" Module-#1170F 01/27/2020 18:26:44 Page 1 PART NO. S DESCRIPTION QTY - ID == Ford, F-450,193"WB,4x4,XLT,170",#1170F-620.045 11/20/17== 1 WC CHASSIS: 1 WC 00-10-4035 S < > Ford 2020 F-450, 4x4, XLT, 6.7L, 193"WB 2020-1 1 WC SAP option 10508694 193"wheelbase Auto throttle OEM Ford Alternator OEM Ford Mirrors, OEM, Heated/Remote Cab seats OEM Captains chairs(no armrests) 05-00-0200 < Conversion, BOM, Type 1, 170 Module, F450 4x4 19-1 1 WC Includes Liquid Spring Rear Suspension CAB TO MODULE MOUNTING: 1 WC 10-10-1001 < > Bellows, Passthru, Unigrip, Fl 2008+, Std 1 WC With Aluminum cab insert. CHASSIS ADD-ONS: 1 WC 1F-30-7551 < Rear Suspension- Liquid Spring-2017+ F450, 4x4 1 WC Dump Feature activated by the Left rear access door. Override switch to be on right rear entry lower panel, top left of lower interior pa lel. Ignition switch Hot. Production note heat shrink wire connections at back of switch. Per KKK, the rear suspension shall only lower the module when the vehicle is in park and the parking brake is set. Liquid spring control panel will be mounted on the front face of the CC, toward Dr. side, use velcro to attach to the console, so the customer can easily remove and adjust setting's, as needed, note not on side, on FRONT of console. CHASSIS ADD ONS, MISC 1 WC 2F-71-4050 < Ignition Security System, Kussmaul, #091-160(Not Dodge) 1 WC • with switch located on dash 2F-71-7103 Cab Flooring, Black Rubber, 2009+, F350/450, OEM 1 WC 5F-10-SR01 X < Paint Wheels(5)ILOS 1 (SO-PT-351178)SR220147F 01/27/2020 18:26:44 Quote No: Elgin New 2020 R3-0001 Pase 2 PART NO - S DESCRIPTION QTY . ID Pt Code Red#FRE 3015 (5)Wheels, Outer's and SPARE tire. (Both sides of Rim) HEATING/AIR CONDITIONING: 1 WC 5U-10-0001 X < Splash/Cover over Elec Heater valves ILOS 1 (SO-CVR-351178)SR 218065F A cover made out of aluminum to protect elec heater valve under compt A area. 5U-12-5000 > Hoses, Heater, No Max, to Rear, STD 1 WC 5U-12-SR01 X < 1/4 turn valves for heat hoses IATS electric controls. 1 (SO-HEAT-351032)SR 220147F 1/4 turn valves for heater hoses in under module by elec valves IATS electric controls. 5U-70-0107 < > Heat/AC, Fl, 2011+, Combo,w/Coolbar 1 WC with thermostat in action area. 12vdc External Condenser, in Coolbar mounted on front of module. Painted Red FRE3015 5U-92-1000 Master Control Digital Thermostat CM5000, ILOS 1 WC BATTERY SWITCHES: 1 WC 60-22-1032 S < > Battery Sw,5 Min Timer F1, Fig 5B, (2)OEM Batt, (1)in RF ILOS 1 WC (SO-BATT-351178) Elec Eng note same as 229833 Timer ILOS set up per Elec Eng for check out lights only. Batt sw will be ign only ! (2)Batteries under hood. (1)Delco 1150 in RF ball compt on a tray IATS, note see battery charger also. BATTERIES: 1 WC 60-30-5000 < Battery, Delco, 1150, (1) Each 1 WC Lower RF compt CONSOLES: 1 WC 7U-10-0602 < Console, Center, Pass-thru, Mica Finish, F1, CN11 1 WC Eng note same as 229833 7U-10-7000 < Console, A/A, Wood, Angled 1 WC Eng note same as 357921 CM300 thermostat. Top row 3 switches& 1 blank. Bottom row 2 switches and 2 blanks Only. ADDITIONAL CONSOLE IN CAB: 1 WC 7U-12-8500 Console, Map Pocket,Bolt on,at Rear,F1 1 WC BULKHEAD CABINET: 1 WC TF-50-SR00 X < > Bulkhead, Custom 1 (SO-BH-351178)SR220147F AC unit over pass through. Eng reference 229833 Pass through. Note DELETE lexan slider at pass through (1) Bi fold Door for CB access to the driver's side of pass through. (1) Bi fold Door for PC board, above pass through (1) Door under pass through same as 229833 WHEELCOVERS: 1 WC No wheel covers, unit has painted rims. 01/27/2020 18:26:44 Quote No: EI•in New 2020 R3-0001 Pa•e 3 PART NO S DESCRIPTION QTY ID X5-10-0002 X < Phoenix Air-Max AML1 valve extenders ILOS 1 (SO-VS-351178)SR220147F Air Valve Ext only valve extenders, rear duals no wheel covers. _=Type 1 Ford - 170"Module-#1170F-620.045 11/20/17== 1 WC 00-00-0247 < *******OUTSIDE GRAPHICS-24/7 ***"** 1 WC Entry door panels. 00-05-0100 < This unit built in accordance with KKK-A1822-F CN 10 1 WC This unit as specified meets all requirements of KKK-A1822-F Change notice 10. All cabinets shall be labeled as to their capacity Rating. 35-05-0055 Type 1 - 170" Module-Standard Model Series 1 WC 35-05-0060 Type 1 - 170" Module General Body Construction Spec • 1 WC 35-05-0065 Type 1 - 170" Module Vehicle Body Structure Spec 1 WC 35-05-2000 < INTERIOR CABINETS-Duralite Construction, Wood, CN10 compliant 1 WC All cabinets shall be labeled with their Rated Weight Capacity. • MODULE BODIES: 1 WC Eng note new for this unit compt A and recessed D cylinder storage in CS entry step well for FW521 brackets ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS LAST UNIT 229833 COMPT a DOOR SIZE AND RF CABINET 35-10-0068 < Aisle Space, 50 inches, STD, Type 1, Std Model Only 1 WC (49-50"actual) • Requires stainless steel wheelwell covers attached to squad bench and basewall cabts that will protrude up to 1.5" into aisleway on each side. Install anti-slip decal with Wheeled Coach logo on curbside and rear stainless steel thresholds, STD 35-10-0320 Module Skins, 0.125 inch 1 WC 35-10-0502 Headroom, 72 in. Type 1 - 170" module, #1170F/D 1 WC 35-11-0300 X Drop Skirt 6"each side forward of wheels 1 37-00-0350 < Coating, Polyurethane, Per compartment(1) Each • 6 WC light gray 37-00-0360 Coating, Polyurethane, Rear Bumper Supports 1 WC 37-00-0361 X < Poly urea CS step area ILOS 1 SR 220147F(SAP# ) Delete lower SS threshold at door way. See reference drawing's, black poly urea ILOS, contact sales ext 285 if you have any question's 37-00-0600 < > Compartments, Sweepout 6 WC • All Compartments sweep out 37-00-0710 < Duraseam Doors, with Hidden Jambs 1 WC - Magnetic door switches, Standard 39-A0-06SR XS < > A, Compt, Custom, Hoseline, 170" Module 1 WC SR 220147F ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMER'S LAST UNIT 229833 COMPT A DOOR SIZE AND RF CABINET The upper A door 01/27/2020 18:26:44 Quote No: Elfin New 2020 R3-0001 Palle 4 PART NO S DESCRIPTION QTY ID increases by 2.75" in height to match change of design on RF cabinet. De- er requires a Modeled view of design for approval, prior to assembly SR218065F Eng this is a change from customer's last units El cabinet over-Drawer over E2 Cabinet Upper compt A, with E2. (ISOS access) Eng upper A door sized to access E2 area ONLY. Lower compt for(2) battery tray. Relocate Hose line HVAC unit over the pass through. ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS LAST UNIT 229833 COMPT a DOOR SIZE AND RF CABINET 39-B1-0155 B1, Compt, Std, 170" Module, 72" HR,.#1170F/D 1 WC 39-B2-0177 B2, Compt, Std, 170" Module, 72"H.R, #1170F/D 1 WC 39-D0-0155 < D, Compt, Mid Height, 170" Module, 72" H.R, #1170F/D 1 WC Single door • 39-E0-0105 < E, Compt, Std, 170" Module, #1170F/D 1 WC Eng reference 229833 With Double Doors Eng note see AA tray Unit will only have a slide out tray in AA, but will require space to bolt in a monitor on the AA cabt above this dogleg. Drop writing tray 3/4 on an inch below standard for inside height of 2.75" space to allow 1/4 alum plate for defib mount in rearward end of AA, thru bolted. 39-F0-0305 < F, Compt, Std, Full Height, 170" Module, 72" H.R, #1170F/D 1 WC Ref 351177 With Dogleg for Stairchair in Compt "F"(9.5"wide) DOG LEG FOR STAIR CHAIR. Door to open past 90 degrees. 39-F0-0600 < >With Dogleg for Stairchair in Compt "F" 1 WC DOG LEG FOR Stryker 6252 Chair. FUEL FILL HOUSING: 1 WC 3A-10-1000 > Housing, Fuel Fill, Cast, F1/C1/D1/M2 1 WC EXTERIOR DIVIDERS: 1 WC 3F-10-1103 < Divider, Vertical, B2, 3/16"Thick, Std Model only 1 WC compt"B2", 10.5"off wall #1 (Fixed) HHilitlil 3F-10-2000 < Divider, Vertical, (1), LF, Full Height 1 WC Full Depth Compt F mounted at edge of dogleg. 1/2 height divider, mounted wall 2&ceiling. Customer requires lower area of compt to be clear for stair chair storage. Same as 229833 SHELF-COMPARTMENT"A"/RF CABINET: 1 WC 3F-20-1000 < > Shelf,Adjustable,(1), RF Cabt Custom 1 WC (1)RF Compt"A"/cabt"El"area, centered. Just above knox box cabinet. • 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 5 PART NO S DESCRIPTION QTY ID Eng note change for 2019 shelf from wall 1 to wall 3 of upper cabinet, below upper cabt dogleg that's on wall 3 and above knox box closeout. 3F-20-1500 < > Shelf, Additional, Adjustable, (1), RF Cab Custom 1 WC RF Compt"A"/cabt"E2"area evenly spaced. SHELF-COMPARTMENT "B"/"B1": 1 WC 3F-30-1000 < > Shelf, Custom, Adj, Cmpt "B", (1) 1 WC From divider to all 3 approx 44"above finished floor SHELF-COMPARTMENT "D": 1 WC 3F-40-3001 < > Shelf, Custom,Adj, Cmpt"D", (1), Std Model only 1 WC Just above scba brackets • SHELF-COMPARTMENT "E": 1 WC 3F-50-0200 < Shelf, Fixed, Cmpt E, for Electrical storage, No Divider 1 WC Elec Eng note relocate GFI breaker box to compt E, on wall 1 of compt, up high ab pve Elec shelf, toward outer edge of shelf for easy access, trim elec overflow cage so the customer can reset breaker easily if needed. SHELF- COMPARTMENT "F": 1 WC 3F-60-6000 < > Shelf, Custom,Adj, Cmpt "F", (1) 1 WC Wall 1 to divider above stair chair height 3F-60-6500 < > Shelf, Custom,Adj, Cmpt"F", (1), Additional 1 WC Wall 3 to divider above 02 window height COMPARTMENT/SHELF, MISC: 1 WC 3F-70-1710 < > Reinforcement, Compartment Wall, For SCBA Bracket 1 WC Wall 2 Compt D for 3 scba brackets, 2 in corners and 1 on wall 2, between the 2 in the corners. WINDOWS: . 1 WC 3P-10-5201 > Window,Upper,CS/Slider,Rr/Fixed,Priv Tint,PAN,Std Model only 1 WC MODULE ENTRY DOOR HANDLES: 1 WC 3U-30-8000 Handles, Patient Entry, Trimark Black/Chrome "SafePass"STD 1 WC EXTERIOR COMPT DOOR HANDLES: 1 WC 3U-40-0510 > Handle, Module Compt, Trimark, Black/Chrome, STD 6 WC 3U-40-0514 < > Latch, Paddle, Trimark, For Trailing Door 1 WC compt"E" 3U-60-0100 > ELECTRIC DOOR LOCK PACKAGE OPTIONS: Click to add 1 WC 3U-60-1390 < > Door Locks,Electric, Trimark, (1)DOOR, Entry Door 2 WC Module entry doors. 3U-60-1400 < > Door Locks,Electric, Trimark, (1)DOOR, Compt Door 6 WC All module compts(except battery compt) 3U-60-1500 < > Switch,Momentary Rocker,Activate Elect Door Locks 1 WC Installed on C/S wall at head of S/B close to CS door, next sw rearward will be the timer switch. 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 6 PART NO S DESCRIPTION QTY ID 3U-60-2500 < > Switch, Stealth, Cab/Mod Doors 1 WC In grille on passenger's side. • 3U-60-3000 > Relay Control Circuit, Electric Locks 1 WC 3U-60-3002 < > Intermotive CAN module for 2017+ Ford F-series 1 WC Required for Stealth switch operation on F series. 3U-60-5200 Circuit, OEM Door Lock to activate Mod Doors(Not Dodge) 1 WC DOOR HOLD OPENS: 1 WC 40-10-1611 < > Hold Opens,Rr Doors,Cast,Grabber(2), 5.5", Std Model only 1 WC - Installed so doors will open as wide as possible • - Mount at Bottom of doors. 40-10-7200 < Hold Open, Gas Strut, Ext Compt, 301b, Std 1 WC Compt B1 40-10-7205 Hold Open, Gas Strut, RF Compt, 30lb, Std 1 WC 40-10-7206 < Hold Open, Gas Strut,Comp Door Only,110 Degree,301b,ILOS 5 WC (5)Compartments B2-D-E-F 40-10-7750 < Holdopen, Gas Strut, CS Entry Door, 35#Standard. 1 WC New Code Per ECN 1823 • DOOR PANELS: 1 WC 45-10-0001 X < Panels, Entry, Durasafe, Stainless Steel, w/Chevrons, ILOS 1 . (SO-PANEL-351178)SR220147F Alum center panels will be covered with diamond grade NFPA Red/Yellow 4" chevron striping by 24/7, 45 degree angle to match rear of module. FENDER FLARES: 1 WC 4A-10-1001 Flare, Fender, Rear, Black Rubber, Std Model only 1 WC BUMPERS: 1 WC 4F-10-20SR X < Bumper,Rear,w/Skids& Flip Up,F1,w/LED DOT Lts, 12" ILOS 1 (SO-BMPR-351178)SR220147F 12 INCH DEEP BUMPER ILOS w/Gator Grip on flip up step. RUNNING BOARDS: 1 WC 4K-10-2112 < Running Boards, Standard, 2017+ F450,w/Gator Grip, #1153F11170F 1 WC NOTE LED Lights in front stone guard!! Adjust light, as needed due to runring boards. SKIRTRAILS 1 WC 4U-10-9250 < Skirtrails,Extruded "C"channel(E-one Style) ILOS 1 WC Rub Rails, Skirtline, One(1)set"C" Channel, 3"Style ILOS PROD NOTE CS FRONT SKIRT RAIL 2 PIECE, CUT TO BE CLEAR OF CS ENTRY ZICO STEP, REAR SECTION FROM REAR OF STEP TO WHEEL WELL AND FRONT SECTION FROM FRONT OF STEP TO FRONT CORNER POST, CALL 285 IF YOU HAVE ANY QUESTIONS. 45 degree cut on all ends of skirt rails, std STONE GUARDS (FRONT): 1 WC Mech Eng change NO full height corn caps 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pase 7 PART NO S DESCRIPTION QTY ID 4U-11-5000 Stone Guard, Front, Dia Plate, 17" 1 WC KICKPLATES (w/STD. REAR STONEGUARDS): 1 WC ' 50-10-2105 < Kickplate, W/Recess, No Light Holes,Duraseam 1 WC NO tow eyes MODULE ADD-ONS: 1 WC 55-10-0001 X < Splash Plate,Urea Tank FiII,Stainless Steel,'011+ "F"-Series IATS 1 • (SO-SPLSH-351178)SR220147F 55-10-0002 X < Splash Plate, Fuel Fill, Stainless Steel, IATS 1 SR 220147F (SO-FUEL-351178)Same as ZZ-20-1A60 • 55-10-00SR X < Flatbar for dealer installed anode plate 1 SR#220147F reference only recent unit 333084 Add (2) pieces of flat bar for dealer installed anode plate. Reference drawing #381391D for flat bar and reference location. Placement dependant on chassis. NOTE: Do not undercoat these plates! Plates to remain raw aluminum! 55-10-3000 < Holder, License Plate, Cast, LP0002, STD 1 WC -in rear kick plate, centered Important shop note install a ground wire attached from tag recess to chassis frame rail !! SILL PROTECTORS 1 WC No sill protector at CS entry door, doorjamb will have black polyurea ILOS 55-30-4001 Sill Protectors, Stainless, All Compts, Std Model only 1 WC MODULE STEPWELL: 1 WC Eng note recessed at wall lfor(2) D cylinder storage cabinet at head of squad bench. 55-90-6000 Stepwell, Double Step, ILOS, Type 1 1 WC MUD FLAPS: 1 WC 5A-10-1001 Mud Flaps, Rear, W/Logo, Std Model only 1 WC PAINT/BELTS: 1 WC See (SO-PT-351178)SR218065F Same as 229833 Pt Code Red#FRE 3015 (5)Wheels, Outer's and SPARE tire. (Both sides of Rim) Black polyurea CS entry door jamb ILOS call extension 285 for information if needed. 5F-10-3200 < > Paint, Entire Unit, Red or Metallic Upcharge 1 WC Reference 229833 Color: RED Sikkens paint code#FRE3015 Module Roof and Drip Rail OEM White FA91:YZ Ref pics on server in wo folder CHEVRON PACKAGES INSTALLED: 1 WC Rear chevron installed by dealer Fire Service. DECAL PACKAGES INSTALLED: 1 WC 5P-10-5001 Roof Star, White Border, Installed, Std Model Only 1 WC ELECTRICAL SYSTEM: Circuitboard 1 WC Reference only 229833 COAX CABLES/ANTENNAS: 1 WC Reference previous unit 229833 SEE AMB ANTENNA PLACEMENT pdf in FILE (5 Ports) 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Page 8 PART NO S • DESCRIPTION QTY ID 65-10-0001 X < Install Customer Supplied Antenna 1 SR220147F art will be delivered to production when ready call Ext 285. (1)Port 2. Terminate tails at circuit board. Tag Elgin#2 AP-CCWG-Q-S2222-RP3-BL 65-10-SR01 X < Specified Antenna installed SR 218065F 1 (SO-ANT-351178)SR220147F Ref 229833 Laird Al 50S (1)Port 3 to terminate at the circuit board (Tag Elgin #3) (1) Port 6 to terminate at the circuit board (Tag Elgin#6) Laird Al 50S VHF unity gain antenna with spring plus associated nmo mount Laird TRA 7603 (1)Port 4 to terminate at the circuit board. (Tag Elgin#4) Laird TRA7603 UHF 3db low profile antenna plus associated nmo mount instal ed ILOS 70176- Laird TRA4503: 450-470 Phantom Antenna. White RF Cable with NMOK Motorola Style roof connector Laird 4503 (1)Port 5 to terminate at circuit board. (Tag Elgin#5) Laird TRA4503 7/800 MHz 3db low profile antenna plus associated nmo mount ILOS 304196-Laird TRA7603: 760-870 Phantom Antenna, White RF Cable with NMOK Motorola Style roof connector 12VDC POWER SOURCES&OUTLETS: 1 WC 6A-22-200E < > Outlet, Cigar Lighter, STD, (2), A/A 1 WC • 20-amp ignition hot circuit. ("elect batt sw") 6A-22-2500 < >•Outlet, Cigar Lighter, IATS, (1) 1 WC Constant hot RF Cabinet El Wall 2 up high and to right. 6A-22-5100 < Outlet, Dual USB Port, 5VDC, 2.1Amp output, Standard 1 WC Located on the passenger side of the center console, per Electrical Engineering 6A-22-5150 < Outlet, Dual USB Port, 5VDC, 2.1Amp output, TATS 1 WC Location AA POWER SOURCE, 12 VDC 1 WC 6A-23-0910 < Power Source, 12VDC, 20A, Ignition/Shoreline Hot 1 WC (1)pre-wire coil and tagged in action area (1)pre-wire coil and tagged behind driver's seat. 6A-23-0950 . < > Power Source,12 VDC,10 Amp(+-) 7 WC (1)Constant Hot to cab console (1) Ignition hot to cab console (2)Constant Hot to circuit board (1)Constant hot to behind AA SW panel (1) Ignition Hot to behind AA SW panel (1)Constant Hot to RF cabt El knox box cabinet 6A-23-2200 < > Power Source,12 VDC,20 Amp(+-) 1 WC (1)Constant Hot to cab console 6A-23-3000 < > Power Source,12 VDC,30 Amp (+-) 1 WC Constant Hot Terminate in circuit board cabinet with 6'tail. 01/27/2020 18:26:45 Quote No: El in New 2020 R3-0001 Page 9 PART NO S DESCRIPTION QTY ID 6A-23-3001 < > Power Source,12 VDC,30 Amp(+-), Std Model only 1 WC -Constant Hot, to terminate in circuit board cabinet -with 6 foot tails(hot and ground). ELECTRICAL ACCESSORIES 1 WC 6E-10-0001 X < Install Med Vault Mini Customer supplied 1 (CS229833)SR 220147F Install customer supplied Med vault mini 5201in RF cabinet El bottom left corner see ref drawing's. Call Ext 285 for delivery of part. Change for Eng see RF cabt change's 6E-10-44SR X < Camera, Hanscom K#HC430RVM rearview mirror 1 (SAP# 10184826)SR220147F make sure mirror bracket fits on a 2019 F450 Mount camera exterior on rear of module, off center toward driver's side. above rear entry door. (1)#HC430RVM rearview mirror with 4.3" integral monitor, (1)#IR250 Camera, BLACK, with 35'of cable. SHORELINE INLETS: 1 WC 6F-90-4105 < > Super Auto Eject, 20 amp, ILOS, Red, Std Model Only 1 WC Mounted above compartment"E" Elec Eng note relocate GFI breaker box to compt E, on wall 1 of compt, up high above Elec shelf, toward outer edge of shelf for easy access, trim elec overflow cage so the customer can reset breaker easily if needed. 125 VAC OUTLETS: 1 WC 6K-40-1000 < Outlet, 125 VAC, Duplex, (2), STD 1 WC -(1)outlet in action area -(1)outlet in the RF Cabinet"El". wall#2, upper right up high by cigar outlet. 6K-40-2000 < > Outlet, 125 VAC, Duplex, IATS 1 WC (1)AA down low at REAR end of AA by CPR Seat BATTERY CHARGERS: 1 WC 6U-10-0100 < > Circuit, Battery. Charger Power Acces. 1 WC 110 Relay to switch to 12VDC power. 6U-10-1600 < > Battery Charger,Kussmaul, Auto 1200,40 amp W/Rem Ind 1 WC Charger/Conditioner MOUNTED IN BATTERY COMPT as in previous 229833 Circuit breaker for the charger wiring MUST be 80 amp inline. Kussmaul remote indicator panel installed next to SL inlet above E (Wired per ELEC ENG 80 amp breaker) GAUGES/METERS: 1 WC D0-10-1200 < Meter,Analog, Volts, Fl 1 WC On center console SWITCH panel D0-10-6500 < Alarm, Low Voltage, AudioNisual 1 WC Light in cab console and Buzzer in cab. 01/27/2020 18:26:45 Quote No: EI•in New 2020 R3-0001 Pa•e 10 PART NO S DESCRIPTION QTY ID SEQUENCING/LOAD MANAGEMENT: 1 WC ENG NOTE: Same as 229833, Engineering note see customer reference pics on server: DA-11-3000 < > Sequencer,Kussmaul,Load Manager, W/Switch 1 WC Eng ref 229833 W/Sequencer switch and override on console SIREN SPEAKERS: 1 WC DF-10-1242 < Siren Speakers, Cast SAD/PSAD3815-17FSD-1;FRD'17+, Fl, Std 1 WC Thru Front Bumper SIRENS: 1 WC DK-10-1400 > Siren, Whelen, WS-295-SLSA1, Standard 1 WC AIR HORNS: 1 WC DP-10-3100 >Additional,Air Tank,For Buell Air Horns 1 WC DP-10-9100 < >Airhorn, Buell, 5440 comp, 10 & 12 inch horns 1 WC mount compressor on fixed shelf in compt"E" DP-10-9215 < > Brackets,Airhorn_Under Front Bumper, F-Series, 2017+ 1 WC Brackets Per Eng design Under front bumper through plastic fairing. SWITCHING OPTIONS FOR AIR HORNS&SIRENS: 1 WC DP-11-1000 Switch, Siren/Horn Thru Horn Ring 1 WC DP-11-5500 < > Switch,Add, 12VDC Momentary Rocker. 2 WC CC Switch panel driver and passenger side, (Air horns) Same as 229833 SWITCHES ADDITIONAL: 1 WC DU-10-2500 < > Switch, 12VDC, Rocker, Amber, Additional 1 WC 10 Amp constant hot Additional switch in cab console, terminate wires in CB cabt with 6 ft tail, tag wire i i CB cabt Wi Fi. DU-10-3100 < > 3-Way Switch, Dome Master Circuit •2 WC (1)switch in ECC (1)switch in action area DU-10-6000 < > Switch, Momentary, Rocker, (1) 1 WC Reference 351177 In AA Lower panel to activate 15 minute check out timer IATS, to allow activation and de- activation. Wire to all dome lights in liner- HIGH intensity. AUDIBLE ALARMS: 1 WC F0-11-3501 Alarm, Back-Up, Auto Reset, Std Model only 1 WC VEHICLE EXTERIOR LIGHTING 1 WC Elec Eng note, minimal of 15 amp breakers for exterior lights per Elec Eng discretion. F3-10-00SR X < Emitter, Tomar#EMIT20-LBUG 1 (SO-OPTI-351178)SR220147F Inst in Cool Bar, Center, above center clear. Tomar#EMIT20-LBUG Preemption Emitter Separate switch prim only and in gear only. 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Page 11 • PART NO S DESCRIPTION QTY ID F3-10-14SR X < Chrome Bezel, Tomar#RECT-37-SMFP - 1 (SO-LT13-351178)SR220147F for Emitter lamp FF-13-SR01 X < Whelen TANF 85 LED Lightstick 1 (SO-TA-351178)SR220147F Same as 229833 Whelen TANF85 8-lamp linear-LED Traffic Adviser, approx 46.75" long, TACT.D1 control head. mounted above load lights • Mount control head in cab per Engineering. • WHELEN FLANGES FOR 9E SERIES LIGHTS: 1 WC FU-38-0100 Flange, Super 9L, #90FLANGC, (1)Each 16 WC < > WHELEN SUPER LED 9L STEADY BURN LIGHTS 11,3,9: 1 WC Elec Eng note, minimal of 15 amp breakers for exterior lights per Elec Eng discretion. FU-40-0500 < > Light, 9L, Super LED, Whelen, Red,Red Lens,ILOS, 90RR5SRR 8 WC (2)Each side standard locations (2) Front Module upper outer corners (2)Rear Module upper outer corners PRI/SEC thru AFM 560 FU-40-0501 < > Light, 9L, Super LED, Whelen,Red,Red Lens,IATS, 90RR5SRR 4 WC (2)to show thru lower rear windows PRI?SEC thru AFM 560 (2)Cool Bar one each side of center clear PRI/SEC thru AFM 560 FU-40-0512 < > Light, 9L, Super LED, Whelen,Amber,Amber Lens,ILOS, 90AA5SAR 1 WC (1) ILOS relocated to upper rear window show thru CS PRI/SEC thru AFM 560 FU-40-0513 < > Light, 9L, Super LED, Whelen,Amber,Amber Lens,IATS, 90AA5SAR 1 WC SS rear window upper show thru • PRI/SEC thru AFM 560 FU-40-0535 < > Light, 9L, Super LED, Whelen, R/C, Clear Lens,IATS, 90RC5SCR 2 WC (2) IATS Cool Bar angles pods PRI ONLY NFPA thru AFM 560 • 5 SERIES(TIR6) SPLIT LED LIGHTS: 1 WC H4-05-5705 < > Light;5L TIR6, Whelen, Red, Red Lens,50RR3ZRR, IATS 3 WC (3) Installed on the Rear and CS Entry door interior panels, lower outer corner. Wired Ignition Hot, to flash when door is open, thru internal flasher, factory default. 5 SERIES(LIN6) NON-SPLIT LED LIGHTS: 1 WC H4-06-5702 < > Light,5L LIN6,Whelen,Red,Red Lens,50R02ZRR, Std, F1/D1 Only 2 WC (2)as grille lights wired thru AFM560 flasher Prim Only Shut down in Park/Neutral WHELEN 5E FLANGES/HOUSINGS: 1 WC H4-10-0044 > Housing, 5L Series,#5LSMAC, (1),Std, F1/D1 Only 2 WC 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pase 12 PART NO S DESCRIPTION QTY ID H4-10-0045 > Housing, 5L Series, #5LSMAC, (1) 3 WC WHELEN SUPER LED 7L LIGHTS W/FLASHERS: 1 WC H5-58-0315 < > Light, 7L, Super LED, Whelen, Red, Red Lens, IATS, 70R02FRR 2 WC Over rear wheels PRI Only NFPA thru AFM 560 H5-58-0375 < > Light, 7L, Super LED, Whelen, Clear LED, IATS, 70CO2FCR 1 WC ILOS Center Clear 7 series under Tomar 7 emitter lamp in cool bar. PRI ONLY- NFPA thru AFM 560 WHELEN FLANGES 7 SERIES LIGHTS 1 WC H5-59-1000 < Flange, Whelen, For 7E lights(1), Mods 5 WC - For 7 Series Lights INTERSECTION LIGHTS, FORD &Chevy Type 1,WHELEN 1 WC H5-59-500E < Light, Whelen;LINZ6R, LED-Red, Std 2 WC with chrome flanges (2)front intersectors PRI ONLY NFPA internal flasher • • CORNER CAP LIGHTS 1 WC HF-11-6049 < Corner Cap Lts,Multi-LED,(2)Amber(2)Red w/Flashers,Std Model 1 WC - High intensity flashers; switched Pri/Sec. NO switch CLEARANCE LIGHTS: 1 WC HF-12-9100 < Light, Clearance,Amber LED, ILOS 3 WC -On front as clearance lights. HF-12-9601 < Light, Clearance, Red LED, Std Model only 3 WC -On rear as clearance lights. SCENE AND LOAD LIGHTS 1 WC HK-20-110M < Light, LED, Whelen, Clear, #9SCOENZR, 24 LED, ILOS, (1)W/Chrome Flange . 4 WC (2)each side as scene lights HK-20-250F < > Light, Whelen, 700 Series, 12LED, Scene Light, ILOS 2 WC Rear loads under the traffic advisor See drawings HK-20-7100 > Scene Lights, C/S, Activated W/C/S Door 1 WC HK-20-7400 < > Rear Scene Lts Activate W/Rev Gear. 1 WC Rear load lights wired to reverse standard. FLASH PATTERN WARNING LIGHTS: 1 WC HU-11-2500 < Brake Override Circuit 1 WC Rear window lower RED HU-11-8500 < > Automatic Secondary, Park/Neutral, W/Momentary Switch, Auto Reset 1 WC the circuit would automatically reset when the gear shift lever is placed back into gear. WARNING LIGHT FLASHERS 1 WC HU-24-7500 < > Flasher, Whelen AFM-560, ILOS 1 WC Set flash pattern to Comet Flash 01/27/2020 18:26:45 Quote No: El.in New 2020 R3-0001 Pase 13 PART NO S DESCRIPTION QTY ID HARNESS LAYOUT: 1 WC J5-12-1000 Halogen, " E " Spec, Whelen 1 WC STOP/TURN/TAIL LIGHTS: 1 WC JA-10-1200 < Light, License Tag, (2), Trucklite#15205 LED, ILOS 1 WC Run ground wire from tag recess, to frame rail ILOS. JA-13-8010 < Tailights, Whelen,LED Stop/Tail,Halogen/Backup,w/WC logo 1 WC Brake-Alert Flash before the steady Burn Turn Arrow—sequential arrow MODULE OVERHEAD HEADLINER: 1 WC SEE Ambulance Antenna Placement pdf in file JK-10-6510 < Headliner, Flat, PVC,w/Hinged trough cover, 160"+ MAV/T1 1 WC 5 antenna ports ILOS. Ref only 229833 12VDC INTERIOR LIGHTING: 1 WC ELEC ENGINEERING NOTE 1 HI- Low-Off switch in AA panel to turn all liner dome lights on and off! JP-10-0611 < Lights, Dome, LED, Whelen,White Fing, (4)S/S, (3)C/S, ILOS 1 WC NOTE: NO VISABLE FASTENERS OR HOLES. JP-10-0621 < Light, Dome, LED, Whelen,White FIng,(1) IATS 3 WC F. G,H JP-10-7015 < Light, Stepwell, LED, Whelen#TOCACCCR, 2in, ILOS 1 WC Wall 3 ILOS, due to recess at hd of bench. JP-10-8030 < Light, Intertek ZY-PIR38 12v, LED, In A/A ILOS 1 WC Install on bottom of L cabinets i!!! JP-11-4700 NO lighting recessed into trough cover-Standard 1 WC LIGHTS & MISCELLANEOUS: 1 WC JR-50-2700 < > Lights,(2), 4in, LED, to Ilium Running Boards, Constant Hot 1 WC relocate light upward to avoid obstruction from runnign board flange!!! • Activated with the cab doors. • JR-50-2885 < Lighting, Compt, LED Hi-Brite Flex, ILOS 1 WC both vertical edges near door jambs and across top edge near door jamb, compts"A", "B1", "B2", "D", "E", & "F". Retain 2"02 light. JR-50-30SR X < Spotlight, Go Light, Black, #2021 1 (SO-GOLT-351032)SR220147F Mount Go-Light in cab roof- centered. Toggle Control to be in CC switch panel at top close to the passenger. JR-60-2003 < > Timer, Momentary Sw,15 Minute, Constant Hot, Std Model only 1 WC Momentary SW for timer 229833, see added momentary switch. Mount switch on C/S wall at the head of the squad bench • 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 14 PART NO S DESCRIPTION QTY ID in the standard location. Switch to allow activation and also deactivation. Wire to all dome lights in liner, HIGH JR-70-0005 < Light, in Circuit Board Area, for Electrical Troubleshooting 1 WC -with integral switch; wired constant hot. CLOCKS: 1 WC L0-10-1500 < > Clock, Analog, Self Cont, 12/24 Hr, 8" 1 WC LOCATION: CSR cabinet see ref drawing SUCTION PUMPS: 1 WC LP-10-0500 Suction Pump, Standard 1 WC INSULATION: 1 WC LU-10-3001 < > Insulation, Severe Weather Package 1 WC one inch block foam in modular walls and roof covered with reflective insulation. Under Floor to be Spray Foam insulated after the production assembly process is complete by 24/7. All edges of reflective insulation on walls and ceiling must'be taped, std. GRABRAIL(S)/GRABHANDLES: 1 WC • N0-10-9101 < Grabrail,Overhead,117",Handicap Style,Yellow,Std Model Only 1 WC • Yellow Powder Coat Finish N0-10-9703 < Handrails,(3),Custom "L"Shape,1",Yellow,Entry Drs,Std Model 1 WC Yellow Powder Coat Finish Stainless Steel Grab Handles • N0-11-1500 < > Grabhandle, 1"X 13.5", Aluminum, (1), On Exterior, IATS 1 WC Outside CS entry Door PAINTED to match module job color Red#FR#3015 02 CYLINDER RACKS: 1 WC NA-10-3550 < Rack, Multiversal,#QR-MV, W/Straps 1 WC Wall 2 near wall 3 NA-10-6502 Track, Unistrut for Oxygen Rack-Standard per ECN 1 WC 02 SYSTEMS COMPLETE: 1 WC NF-51-2000 < > 02 Sys, LF Stor, (2)O2/Vac Port-NA, (1)02-Liner, (1)02 C/S 1 WC SEE REF DRAWING AA Layout 02-02-VAC (vac port close to suction container.) Same as 229833 ohio style (2)oxygen outlets in action area (1)vacuum port in action area(Down low close to suction container see ref drawing) (1)oxygen outlet in liner at head of cot (1)oxygen outlet cs wall at head of squad bench 02 SYSTEM PARTS: 1 WC P0-59-7500 Regulator, Oxygen Cylinder, Preset 50PSI, Installed 1 WC SUCTION CONTAINERS: 1 WC PA-10-7003 < > Regulator/Holder, SSCOR 23002 with Canister clip-CN 10 Compliant 1 WC Conforms to J3043 requirements ' Relocate forward in AA to under the AA switch panel, see drawings for reference. 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 15 PART NO S DESCRIPTION - QTY ID COT MOUNTS: - 1 WC PF-26-3500 < Stryker Power Load- No Wheel Guide-Change Notice 8- COMPLIANT 1 WC includes constant hot power supply for battery charging. IV HOOKS: 1 WC PP-20-1000 < > IV Hook, Perko, (1), W/Straps, STD 2 WC curbside and streetside standard locations PP-20-9000 < > IV Hook, Cast, Fold Down Recessed, IATS 2 WC IV2 SS and IV2 CS KICK PLATES STAINLESS STEEL, ON CABINETS: 1 WC PU-10-1001 X < Kickplate, Brushed S/S, Face Of Squad Bench ILOS 1 Customer request New Eng drawing#381728d rev a Full Height on squad bench Ref pics on server reference 229833. PU-10-2000 Kickplate, 8" Brushed S/S, On Face of Basewall 1 WC MISC. INSTALLED HARDWARE/EQUIPMENT: 1 WC R5-10-0001 X < Ferno#2746-43208 Ferno D.360 Swivel defibrillator mount 1 (SAP# )SR218370F Rearward end of AA mount per cust ref drawing on server in work order folder. Ferno#2746-43208 Ferno D.360 Swivel defibrillator mount R5-10-2000 . < > Bracket, SCBA, Ziamatic, UN-6-30-3-F-CRS 3 WC Compt D on corner brackets and 1 centered on wall 2 down low. See reference picture on server in wo folder R5-10-8000 < > Wrench, Oxygen, Tethered, Mods 1 WC in oxygen compt. R5-11-5710 < Seatbelt, Assy, (4 Point), Per4Max, Black, (1)Each -CN-8 3 WC Above the Lid installation (1)for CPR side seat (2)for squad bench R5-12-SR00 X < Bracket, Zico, SCBA,Angled 2 (SO-BRKT-341057)SR220147F (2)Compt"D", floor level 1 ea corner. DRI-DECK/TURTLETILE: 1 WC RA-10-2000 > Dri Deck, Black, All compt. Floors and Shelves 1 WC HOLDER, CYLINDER: 1 WC RF-11-6050 < > Holder, Cylinder, Single, Zico QR-D-2 Strapless, -CN 10 Certified 2 WC (2) Mounted at head of bench in recessed cabt. STRAPS, INSTALLED: 1 WC RK-13-3500 < Seat Belt, Across Compt Opening 1 WC Compt F, wall 1 to wall 2 to hold stair chair in place. Leave 4 inch tail for strap adjustment MODULE INTERIOR 1 WC RU-05-0000 Interior Cabinets- Duralite Construction, Wood-CN 10 Compliant 1 WC MICA COLOR: 1 WC 01/27/2020 18:26:45 Quote No: El.in New 2020 R3-0001 Pase 16 PART NO. S DESCRIPTION QTY ID RU-14-1900 Mica,Dove Gray Over Pewter Brush 1 WC SUB FLOORING: 1 WC RZ-99-0050 Flooring, Wood, Type 1, Std . 1 WC FLOORING: 1 WC T0-11-8201 Flooring, Lonplate II,Gunpowder Grey#424TX, Std Model only 1 WC SEAMLESS ATTENDANT SEATS: 1 WC T5-10-5111 < Seat,Attendant, EVS, Child,Gunmetal#1880CB, Std Model only 1 WC Seat location same as 229833. Vacuum formed EVS1880CB w/3 point seatbelt. Integrated child safety seat. Mounted metal box base. Opening faces toward the rear. SEAMLESS UPHOLSTERY: 1 WC T5-25-0500 Uph, Smless, Gunmetal,No Bio,No Post&Wheel 1 WC CUSHIONS: 1 WC T5-40-2106 > Upholstery, Backrest Cushion, EVS, Gunmetal,w/WC Logo 3 WC 02 DOOR: 1 WC TK-10-5000 > Lexan Flap W/Hinge 1 WC GLOVE HOLDERS: 1 WC TN-20-1001 < > Cabinet, Glove Box Holder,(3),Above C/S door, Std Model only 1 WC Must use M1 latches for KKK Change notice 10 compliance RIGHT FRONT CABINET: 1 WC ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMER'S LAST UNIT 229833 Note set Knox box cabinet back, Austin Gen 2 doors will close over knox box, decrease depth of knox cabt, and leave the back open, close out will be 2 inches deeper than the depth of the knox box, space behind this close out will be used for storage. TU-20-14SR XS < > Cab, RF, W/O Healthguard, AC/Combo, Custom 1 WC REF ONLY(SAP#10522451)SR220147F New for this unit ! See NEW drawing. • El Inside access only(Upper) Drawer center section E2 Inside/Outside access(Lower) Eng note close out bottom left area of El at Wall 1 for a Med vault mini un flanged and recessed style medvault. Medvault will sit behind door, close out to be 2 " longer than medvault, New snit change for 357921! Call 285 if needed ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS LAST UNIT 229833 Note set Knox box cabinet back, Austin Gen 2 doors will close over knox box, decrease depth of knox cabt, and leave the back open, close out will be 2 inches deeper than.the depth of the knox box, space behind this close out will be used for storage. RF CABINET DOORS W/COMBO NC 1 WC TU-20-8430 < Doors, RF, Upper, Dual Gen II OHO, Polycarbonate Doors, Gray, VA style 1 WC RF cabt El 01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa.e 17 PART NO S DESCRIPTION QTY ID TU-20-8530 < Doors, RF, Lower, Dual Gen II OHO, Polycarbonate Doors, Gray, VA style 1 WC RF cabt E2 HARDWARE,LATCHES AND LOCKS: 1 WC V0-10-1000 < > Handle, C, Pull, Installed, (1) Each, IATS 1 WC AA tray V0-14-2075 < > Latch, Southco M1, 2IN S/S, (3/4"door)Non-Locking, (1), CN 10-Rated at 10Ibs 3 WC (self latching) Flush Mount. Non-Locking (1) RF cabt drawer (2)cabinet 0 drop down door V0-14-2078 < > Latch, Southco M1, 21N S/S, (3/8" Door) Non-Locking, (1), CN 10-Rated at 10Ibs 8 WC (self latching) Flush Mount. Non-Locking, (2)GB cabt(2) K2(2)R1 (2)R2 SQUAD BENCH: 1 WC V5-20-50SR X < > Squad Bench, Custom 1 (SAP# 10522452)New design for bench SR220147F Recessed vertical style D cylinder storage to fit (2) Cylinder, Single, Zico QR-D-2 Strapless, NO waste LID 170 INCH BOX: 1 WC V5-64-0500 Lid, Squad Bench, Single 1 WC HARDWARE: 1 WC V5-80-1005 Handle, Trimark, Squad Bench, STD 1 WC V5-82-2500 Strut, Gas, 60 LB, Installed, ILOS, Mods 1 WC CURBSIDE SPLINT CABINET 160-170 inch Module 1 WC VA-40-4530 < > CS Splint,7in Deep,2 Sect,Gray Lexan Flapglass, 170 Module 1 WC Note: TO meet KKK requirement for space between • cushion on squad bench and bottom of splint cabt. Gray Lexan Flap glass with Spring hinge (4)2- M1 latches on each door • CURBSIDE REAR CABINET: 1 WC VF-20-4700 < Cabinet,Curbside Rear,Standard,170",72"HR 1 WC Eng note Dump switch is RELOCATED to RR entry door CABINET H, BASEWALL 170", T1/T3 1 WC VH-H2-SR00 XS < > H/M Combined Cabinet, Custom 1 WC SR 220147F(SAP# Combine H and M cabinets into a single cabinet, CN 10. Single divider centered in cabinet with a shelf on each side of cabinet. CABINET I, BASEWALL 170", T1/T3 1 WC VH-12-0400 I, Cabinet, Deleted 1 WC CABINET M, BASEWALL 160"& 170", T1/T9 1 WC DELETED see H/M combined VH-M2-0300 M, Cabinet, deleted 1 WC CABINET 0, BASEWALL 160-170", T1/T3 1 WC 01/27/2020 18:26:45 Quote No: EI•in New 2020 R3-0001 Pa•e 18 PART NO S DESCRIPTION QTY ID VH-OI-SR00 XS < > 0, Cabinet, Custom 1 WC (SO-O-351178)SR220147F Dimensions: 15"h x 21.75"w x 19.5"d Same as 229833 *Wood door hinged at bottom. *Add(2)cables to hold door at approx. 30 degrees. CABINET CPR, BASEWALL, 149"-170", T1 &T3 1 WC VH-Q0-0101 CPR,side seat, Std Model only 1 WC VH-Q0-0301 < CPR, side seat, flip up lid, Std Model only 1 WC With Trimark Latch VH-R1-0105 < "U" Barrier Bar, Padded, 6 7/8 x 7 1/2, 1.5 inch SS, CPR Seat, Gunmetal 1 WC Mounted at the front of the CPR side seat vertically in line with the Padded head cushion on the "L"cabinets. CABINET J, STREETSIDE UPPER 170", T1/T3 1 WC VI-J2-0150 > J, Cabinet, Combined with K 1 WC VI-K2-0100 < K2, Cabinet,w/CPR seat 1 WC Note: TO meet 43" minimum KKK requirement for space between cushion on S de seat and bottom of splint cabinet. 3/8 gray flip up with 2 southco latches. CABINET L, STREETSIDE UPPER 160-170", T1/T3 1 WC VI-L1-0355 < L, Cabinet, L1, L2 Combine into 1 Large Cab, 72" H.R, Full F 1 WC with adj shelf in "L2" BASEWALL DOORS: 1 WC VK-15-4020 < Cab H, Gray Polycarbonite Slider-CN 10 Compliant 1 WC This is for H/M cabinet TELEMETRY AREA WORK SURFACE 1 WC VP-10-5461 Telemetry Tray, Poured, Gray 1 WC ACTION AREA WORK SURFACE 1 WC VP-10-SR02 X < 'Action Area Tray, Stainless Steel, ILOS 1 (SO-TRAY-351178)SR220147F ACTION AREA 165/170 INCH BOX: 1 WC VP-15-7005 < Cab,A/A,Without Biowaste, 170"Type 1 1 WC Slide out tray ILOS, TRAY only, change from customer's last unit. Reference prey ous unit 229833 VP-15-8500 S < > Writing Tray, Slideout,Under A/A Tray 1 WC BOM option code 10535560. Drop writing tray 3/4 of an inch below standard for inside height of 2.75" space to a low 1/4 alum plate for defib mount in rearward end of AA, thru bolted. VU-14-4000 < > Shelf, Interior, Adj, in Cabinet: 4 WC (2) H/M combined, 1 ea side of divider (1)J (1)L • • VU-14-4001 < > Shelf Track, Cabt, #HA24663, Upgrade, Std Model only 4 WC ("C"channel/exterior shelf style track) VU-15-1820 Cab"J/K" Combined, Gray Polycarbonate Slider-CN 10 Compliant 1 WC VU-15-7220 > Cab"L1,L2,L3"Combined, Grey Polycarbonate Slider-CN 10 Compliant 1 WC 01/27/2020 18:26:45 Quote No: El•in New 2020 R3-0001 Page 19 PART NO S DESCRIPTION QTY ID VERTICAL DIVIDERS: 1 WC VU-45-1000 < Divider, Vertical, Streetside Upper Cabinet 1 WC Centered H/M cabinet !! SHIP LOOSE ITEMS: 1 WC YY-00-0001 > Bracket, Spare Tire Mounting, Ship Loose - 1 WC YY-00-0004 X < Handheld Spotlight-Sho-Me 200,000 CP Ship loose 1 (Option code 10131387)Ship loose YY-00-SR01 X < 5 qt Sharps disposal and mounting bracket 1 (SO-SL-351178)SR 220147F Armstrong Medical 5 qt Sharps disposal & mounting bracket. Boundtree #2985078A -5-quart transparent red sharps container&#298516 wall enclosure with lock . • YY-10-6400 Ship Loose, W.C. Standard Items 1 WC FIRE EXTINGUISHERS: 1 WC YY-13-2000 Fire Extinguisher. (1)5 LB. ABC, IATS, Ship Loose 1 WC YY-13-3000 > Spare Tire, OEM only, Ship Loose 1 WC WARRANTIES 1 WC ZZ-10-0201 Warranty, Paint, 60 month Prorated, Standard 1 WC ZZ-10-0300 Warranty, Structural, 15 Years, Std., Mods 1 WC ZZ-10-0601 Warranty, Limited Electrical 1 WC ZZ-10-0701 Warranty, Cabinet Construction 1 WC ZZ-10-2200 > Warranty, Extended, 3 Year/36K Miles, Types 1, 3, 9 1 WC ZZ-ZZ-0200 > End Of Order 1 WC 1 . CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 95 BACK UP CAMERA TAM85 TRAFFIC ADVISOR TOMAR 700 LED LOAD LT. 700 LED LOAD LT. COOL BARR R/C R R R/C R 900 RED LED LT. 900 RED LED LT. (6)900 LED LTS. o o II n ___, 4,. i Vg EA fel [ FM 1 1 -:...Fi :. :.:.: ,�r l 700 LED LT. 900 AMBER LED LT. 11 Or 900 AMBER LED LT. 900 BRAKE OVERRIED 14 ] 0 Oil 0 4,1,1 900 BRAKE OVERRIE • GO LIGHT Pei I 'oi A per • \:,.... A �( 1 • ,- -, ffn, 1 1 III. ., , ... :I3: 11" �.33:1i WC TAIL € lij: 3= TIRE RED LT. ___ I TIRE RED LT. I€ `' liii=�i:i1 1 LIGHTS LIF •ii 0,, r v n . .. .,,...5...w..,:::::,, h'. . . . .. i :..t„5,4,. :18 �, n r rM1 tr_____. 1!0, II.�I�J� I{ v �1 tti� ,r'<�7���Y_ v° .....a 5� in y � C ss _- :s :J1 ry. ® 0 4"LED RUNNING � 1121 STEALTH BOARD LTS(2) 1111111111 11111111111 \.___i -AIR HORNS SWITCH SIREN SIREN SPEAKERS EXTERIOR COMPARTMENT DIMENSIONS IN INCHES ed Wheel INTERIOR DIMENSIONS PASS THRU INTERIOR DIMENSIONS JAMB OPENING Coach COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH F450 4X4 TYPE 1 FORD 2019 FRONT/REAR EXTERIOR VIEWS DA fE: SCALC BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED 2/11/19 50"AISLE TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR 1-"WN'3Y AP -LW.,NO 1 /9 REFERENCE ONLY PRIOR TO FINAL ENGINEERING CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 900 LED SCENE LT. 170 900 LED SCENE LT. 900 RED LED LT. 900 RED LED LT. F I QINDICATOR LT. // �177 �n7 20A SUPER AUTO EJECT • / — 1" 11 i 1AIRHO:NCOMP500 SERIES LT �11' 1 /{l L—_ 700 R/C LED ;_: �� it. jE _�'_��-- D _ - ® - DEF FILLC II��EDSHELF ��Le „,„,„, !I-m I 411111 �,: ;u It . . b LSI b �"Y DOGLEG FOR STAIR CHAIR VO STAINLESS ir 91 I > RUNNING BOARD SPLASH GUARD 108 CA 193 WB 307 APPROX.OAL BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR. REFERENCE ONLY PRIOR TO FINAL ENGINEERING EXTERIOR INTERIOR DIMENSIONS AMBCOMPARTMENT DIMENSIONSIN OPENING INTERIOR DIMENSIONS JAMB OPENING Wheeled COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH Coach • D 36.75 34.00 17.25 36.25 30.50 F450 4X4 TYPE 1 FORD 2019 E 36.25 39.25 17.00 36.25 37.00 F 82.50 28.25 17.25 81.75 27.25 LEFT EXT. VIEW OATS DALE 2/11/19 50"AISLE DRAWN 0V AP DwcNo 2/9 CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 900 LED SCENE LT. m 900 LED SCENE LT. 900 RED LED LT.--..„...... 900 RED LED LT. 62 ADJ.SHELF (10 el . A T /® 500 SERIES LT 700 R/C LE� ® ® 1=�■ :,..:i_ 61 _ al Ch B - � - 0 ' (----1-7 • ••••• • :;:;:i:i:i:i:i:;.:::::•:•:•:•:•:•.•:•.,:w.•:•.......-.•:...........:•.•::•:::::•:1 084%, , . ;,0;., . \ZICO STEP /15/OS TO E2 ONLY RUNNING BOARD BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR REFERENCE ONLY PRIOR TO FINAL ENGINEERING INTERIOR DIMENSIONS EXTERIOR AMBCOMPARTMENT DIMENSIONSIN OPENING INTERIOR DIMENSIONS JAMB OPENING Z Wheeled COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH Coach A 25.50 27.25 F450 4X4 TYPE 1 FORD 2019 - B1 20.00 14.25 17.25 19.25 12.00 RIGHT EXT.VIEW B2 82.50 19.00 18.50 81.75 17.00 LOWER-A 15.25 30.50 19.00 DATE 2/11/19 SCALE . 50"AISLE DRAWN 6V AP DWG NO 3/9 CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 COMBO HVAC 12V • wwwawawaaawaaoaaoa Y_1X Y �, 11oV waawooawwawawwwwwaaawwwww aaacoaaanwcawaaaaaw ioaaa IE—�I I��I i°Ooo , �oaaw �—ALUM.TRIM So ; �°°°a000000 oaoowooaa oowa°o°a°a°° �1.-.��-.--•- -•.-,•`._-•_....... --`— ' — --ADJ.SHELF m SPEED STRAPS I ®a W/CLIPS br--- I I� — . KNOX BOX MINI#5201 ENCOLSED ON THREE SIDES I—__-_____ 72 E1 Y 8 jT DRAWER ALUM.TRIM --- SHELF SPEED STRAPS a 1 a W/CLIPS BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR REFERENCE ONLY PRIOR TO FINAL ENGINEERING CABINET WEIGHT RATINGS: INTERIOR CABINET DIMENSIONS IN INCHES NON-RESTOCKING=40 LBS. CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Wheeled RESTOCKING=30 LBS. Coach' El 28.25 33.50 32.25 DRAWER 5.00 25.50 30.00 F450 4X4 TYPE 1 FORD 2019 E2 28.25 33.50 32.25 BULKHEAD INTERIOR • DATE Si.ALE 2/11/19 50"AISLE DRAWN eYAP DWG NO 4/9 CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 CM3000 DIGITAL THERMOSTAT \ i Mr K2 17 \ r---- -1 • J `\ `� , L1 `\ N AC CAB. i USB • ® - - CN10 BARRIER N N CUSHION � N \__ ---=•-- n ii.:: „ a \\ 43 A Nv _ L72 /i aMI1 • I 11� L TRAY 7 Io II oiQ I r o I t C t L1 c No o i o IJ III(JL •J I 1 I IL l 1 I —DROP DOWN DOOR INTERIOR CABINET DIMENSIONS IN INCHES Z Wheeled CABINET HEIGHT WIDTH _ DEPTH CABINET HEIGHT WIDTH DEPTH Coach H 21.75 53.50 18.25 J 18.75 48.00 18.25 0 15.00 22.25 18.25 F450 4X4 TYPE 1 FORD 2019 K2 6.00 22.25 6.50 _ L1 18.75 41.00 16.00 • LEFT INTERIOR """ 2/11/19 "A" CABINET WEIGHT RATINGS: 50"AISLE NON-RESTOCKING=40 LBS. BE ADVISED THAT THESE ARE,PRELIMINARY LAYOUTS INTENDED ONN" AP °"A"° 5/9 RESTOCKING=30 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR REFERENCE ONLY PRIOR TO FINAL ENGINEERING • • CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 NON STANDARD CABINET • REQUIRED FOR SEATED HEADROOM. r 3/8"FLIP UP LEXAN (2) 7 'I i! 17 1 — – 1 AC CAB.- ' 1. O 002 •\ DBL TINT A A A A 43 ° 72 J \\' N V w I I I I w g I I I I 7 (////4„ '>•- ,—, ,:o.", / ( 1.14,11, ILLEA , ,11+, _)_/;) . L2�1 II 01 1 0 I id 111311 1101 1 0 ! Jr ----� --._. f1 I I ° I • L ry I I II I ] . (2)"D"CYLINDERS11E9 LL II e TIR 6 LIGHT • 72 INTERIOR CABINET DIMENSIONS IN INCHES Wheeled Coach COMPT. HEIGHT WIDTH •DEPTH COMPT. HEIGHT WIDTH DEPTH • R1 5.00 30.25 7.00 F450 4X4 TYPE 1 FORD 2019 R2 5.00 30.25 7.00 RIGHT INTERIOR 0 15.00 22.25 18.25 WiE 2/11/19 SGLE 50"AISLE CABINET WEIGHT RATINGS: BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED WF° AP 6/9 NON-RESTOCKING=40 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR RESTOCKING=30 LBS. • REFERENCE ONLY PRIOR TO FINAL ENGINEERING CA164684 • CITY OF ELGIN FIRE DEPT. 170x95x72 • CLOG 01 CN 10 ,- BARRIER CUSHION 1i 72 E n n 3 1M-V/ }-17117 (2)"D"CYLINDERS COI QV . I I ~ J I.I INTERIOR CABINET DIMENSIONS IN INCHES Wheeled Coach COMPT. HEIGHT WIDTH DEPTH COMPT. HEIGHT WIDTH DEPTH F450 4X4 TYPE 1 FORD 2019 • REAR BULKHEAD INTERIOR DATE 2/11/19 SLE 50"AISLE CABINET WEIGHT RATINGS: BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED '""" AP 7/9 NON-RESTOCKING=40 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR RESTOCKING=30 LBS. REFERENCE ONLY PRIOR TO FINAL ENGINEERING CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 GLOVE BOX I R1, III R2 I STEP WELL ) II t II I ll I II SQUAD BENCH ICOMPT.B1L COMPT.B2 E CABINET ' L--- . rff el STRYKER-POWER LOA= — 50 1- Io ro I3LI-1 I a �, , o = a SEAT TRAVEL s W I FROM CENTER „e �� POSITION I II � .°T) f i SAME AS351177 I� Li CABINET 1 r J CABINET ACTION AREA I CPR SEAT 1 I COMPT.F I I H CABINET I I I COMPT.F K2 CABINET COMPT.D / BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR REFERENCE ONLY PRIOR TO FINAL ENGINEERING • INTERIOR CABINET DIMENSIONS IN INCHES Wheeled CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Coach' F450 4X4 TYPE 1 FORD 2019 FLOOR PLAN DATE: SCALE 2/11/19 50"AISLE OWN aY AP DVA"0 8/9 CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72 —(10)LED DOME LTS. in 1 N I ►U r—Ti�� II °I t I I (-7 1 ,;. ''' • o' o' o GRAB RAIL COAX 1 1 °J °J COAX 3 °J COAX 5 E ,, 9.) . •-• N.--.- ,-_.., COAX 2 i WIRE TROUGH COAX 4 r---I X01 401 X01 4.01 L_• 7 r i it — ——+ II •I I 1 II I I I II I ' I I II— - I I BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR REFERENCE ONLY PRIOR TO FINAL ENGINEERING INTERIOR CABINET DIMENSIONS IN INCHES Wheeled CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Coach • F450 4X4 TYPE 1 FORD 2019 LINER D' SCALE 2/11/19 50"AISLE D""HY AP DWG NO 9/9 ATTACHMENT C '1. 111t? SALES CONTRACT This agreement made by and between FIRE SERVICE, INC (Company) and City of Elgin, IL (Legal Name of Buyer) 150 Dexter Ct Elgin IL 60120 (Address) (City) (State/ Province) (Zip/Postal Code) 1. ACCEPTANCE: The "Company" agrees to sell and the "Buyer" agrees to purchase the ambulance and equipment described in the Wheeled Coach specifications and made part of this contract, in accordance with the terms and conditions listed on contract pages 1. 2, and 3., and in agreement and utilizing the tag on clause within the contract between the City of Elgin, IL and Fire Service, Inc which was fully executed on June 10, 2015. 2. DELIVERY: The ambulance shall be ready for delivery within approximately 90 - 120 calendar days, after the receipt and signed acceptance of this contract, confirmed build order and chassis at the REV Group Orlando Corporate Headquarters, Winter Park, FL. The Company cannot be held liable for penalties and/or delays due to strikes, failures to obtain materials, fires, accidents, force majeure, or any other causes beyond the Company's control. In order to establish a stable design, procurement, and build schedule, a Buyer change order cutoff • date of eight (8) Days from the date of the execution of the contract will be enforced. Changes in • major components, configuration, or other items that may change the major components or configuration,(e.g.: Chassis, Motor,Transmission,Wheel Base)will not be allowed after the contract execution date. If inability to obtain exclusive or brand name materials causes completion or delivery problems, the Company shall advise the Buyer of said problem. The Company resolves to examine alternative sources of said material. Material substitutions shall be mutually agreed upon by the Buyer and the Company. No substitutions shall be made without the execution of a written change order by the Buyer. 3. CHANGE ORDERS: Changes to the contract may be requested by the Buyer after the execution of the contract according to Section 2 of this document. Changes shall be reviewed for cost and schedule impact by the Company. Changes shall be sequentially numbered. Change Orders shall be prepared by the Company and executed by the Buyer. The price of the apparatus shall be adjusted to take into account any Change Orders. Any and all Change Orders may extend the completion and delivery of the ambulance. FSI Sales Contract, Page 1 of 3 Original (03-10-2006) Sales Policy Manual Attachment F • 4. SPECIFICATIONS: The Company agrees that all material and workmanship in and about this apparatus shall comply with the original Wheeled Coach proposal dated.February 16,2018. (1) Wheeled Coach 2018 F450 Chassis Type I Custom Ambulance per City of Elgin Specifications. 5. WARRANTY: Shall be as proposed in the attached Wheeled Coach specifications. 6. PRICE: The Buyer shall pay, as a purchase price for the ambulance(s), the sum of Two Hundred Fifty-Thousand,Three Hundred Sixty-Two and 00/100 dollars or(L 250,362.00). All prices are less any applicable local, state, or federal taxes which may be applied to the apparatus proposed. NOTE: Payment shall be made only to: Fire Service,Inc. 9545 North Industrial Drive Saint John, Indiana 46373 7. TERMS OF PAYMENT: F.O.B. St. John, IN. Zero down payment, full payment at delivery via wire transfer or municipal check. The purchase price payment reflects US dollars and does not include any authorized change orders which, if applicable, shall be paid at time of final inspection and signed acceptance. b) No payment of any amount shall be made payable to a sales representative without written approval from the company. c) It is agreed that the ambulance and equipment covered by this contract shall remain the property of the Company and not be placed in service until the entire contract price has been paid. d) A copy of the Buyer's tax-exempt certificate, if applicable, shall be submitted with this signed contract. 8. FIRE SERVICE, INC requires,and the Customer agrees, that the unit shall be inspected and /or delivered within seven(7)days of notice that the unit had been completed. 9. CANCELLATION: This contract is subject to cancellation by Buyer only upon payment to Company of reasonable cancellation charges,which shall take into account expenses already incurred and commitments made by Company. FSI Sales Contract, Page 2 of 3 Original(03-10-2006) Sales Policy Manual Attachment F • This contract,to be binding,must be signed by an officer of Fire Service,Inc or a person authorized, in writing,by Fire Service, Inc. to do so. 10. TAG-ON /ADDITIONAL ORDERS: At its sole discretion, the COMPANY may allow the terms of this contract to be extended to both the BUYER and similar agencies for the purchase of a similar unit(s)under similar terms for a period of three(3)years from the date of the execution of this contract. Should the COMPANY choose to exercise this option, it shall be permitted to adjust the contract pricing to account for equitable price adjustments associated with the change in the cost of the materials used to produce the unit. Such adjustments will be based upon the Producer Price Index (PPI) for fire trucks and I or heavy transportation equipment or by itemizing price changes expected by the company from the component vendors. If there are any changes between the unit(s)purchased via this contract and any subsequent orders, those changes must be documented via properly signed and executed change orders, including any necessary price adjustments. If the purchasing agency is not the BUYER, a separate contract will be required to complete the additional purchases. This contract,including its appendices,embodies the entire understanding between the parties relating to the subject matter contained herein and merges all prior discussions and agreements between them. No agent or representative of the Company has authority to make any representations, statements, warranties, or agreements not herein expressed and all modifications of amendments of this agreement, including any appendices, must be in writing signed by an authorized representative of each of the parties hereto. No surety of any performance bond given by the Company to the Buyer in connection with this • Agreement shall be liable for any obligation of the Company arising under the Standard Warranty. • • IN WITNESS WHEREOF, the Buyer and the Company have caused this contract to be executed by their duly authorized representatives this 7th day of March, 2018. • COMPANY BUYER Fire Service, Inc. City of Elgin, Illinois 9545 North Industrial Drive 150 Dexter Court Saint John, Indiana 46373 Elgin, Hlinois 60120 219-365-7157 Phone 847-931-5660 Phone 219-365-8572 Fax 847-931-6027 Fax BY J4 Lege4. B � NAME: Jeff LeBeda NAME: .�`�+` /1 TITLE: Vice President of Sales TITLE: DATE: March 7.2018 DATE:March7. 2018 FSI Sales Contract, Page 3 of 3 Original(03-10-2006) Sales Policy Manual Attachment F