HomeMy WebLinkAbout20-22 Resolution No. 20-22
RESOLUTION
AUTHORIZING EXECUTION OF A PURCHASE AGREEMENT WITH FIRE SERVICE,
INC. FOR THE PURCHASE OF A WHEELED COACH FIRE AMBULANCE
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN,ILLINOIS,that
pursuant to Elgin Municipal Code Section 5.02.020B(9) the City Council hereby finds that an
exception to the requirements of the procurement ordinance is necessary and in the best interest of
the city; and
BE IT FURTHER RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN,
ILLINOIS, that Richard G. Kozal, City Manager, and Kimberly A. Dewis, City Clerk, be and are
hereby authorized and directed to execute a Purchase Agreement on behalf of the City of Elgin with
Fire Service,Inc., for the purchase of a Wheeled Coach fire ambulance, a copy of which is attached
hereto and made a part hereof by reference.
s/David J. Kaptain
David J. Kaptain, Mayor
Presented: February 26, 2020
Adopted: February 26, 2020
Omnibus Vote: Yeas: 7 Nays: 0
Attest:
s/Kimberly Dewis
Kimberly Dewis, City Clerk
PURCHASE AGREEMENT
This Agreement is hereby made and entered into this 26th day of February , 2020,
by and between the City of Elgin, Illinois, a municipal corporation (herein referred to as "City")
and Fire Service, Inc., an Indiana corporation, (herein referred to as "Fire" or"Seller").
NOW THEREFORE, for and in consideration of the mutual promises and covenants
contained herein, the sufficiency of which is hereby mutually acknowledged, the parties hereto
hereby agree as follows:
1. PURCHASE. City shall purchase, and Fire shall sell the goods described by Attachment
A attached hereto and made a part hereof; and as described in the Wheeled Coach specifications
attached hereto and made a part hereof as Attachment B, pursuant to the contract between the City
and Fire dated March 7, 2018,attached hereto and made a part hereof.
2. TERMS. This agreement shall be subject to the terms and conditions contained herein and
as provided by Attachments A, B and C.
3. CONFLICT. In the event of any conflict between any of the terms and provisions of this
purchase agreement and any Attachment hereto, the terms and provisions of this purchase agreement
shall control. In the event of any conflict between Attachments A and C hereto, Attachment A shall
control. In the event of any conflict between Attachments A and B hereto, Attachment A shall
control.
4. LAW/VENUE. This agreement is subject to and governed by the laws of the State of
Illinois. Venue for the resolution of any disputes or the enforcement of any rights arising out of or
in connection with this agreement shall be the Circuit Court of Kane County, Illinois,without jury.
SEC hereby irrevocably consents to the jurisdiction of the Circuit Court of Kane County, Illinois
for the enforcement of any rights, the resolution of any disputes and/or for the purposes of any
lawsuit brought pursuant to this agreement or the subject matter hereof;and Fire agrees that service
by first class U.S. mail to Jeff LeBeda, agent of Fire Service, Inc., 9545 North Industrial Drive,
Saint John, Indiana 46373 shall constitute effective service.
5. NO MODIFICATION. There shall be no modification of this agreement, except in
writing and executed with the same formalities as the original.
6. MERGER. This agreement embodies the whole agreement of the parties. There are no
promises, terms, conditions, or obligations other than those contained herein, and this agreement
shall supersede all previous communications,representations,or agreements,either verbal,written
or implied between the parties hereto.
7. INTEREST. Fire hereby waives any and all claims or rights to interest on money claimed
to be due pursuant to this agreement, and waives any and all such rights to interest to which it may
otherwise be entitled, pursuant to law, including, but not limited to, pursuant to the Local
Government Prompt Payment Act(50 ILCS 505/1, et seq.) as amended or the Illinois Interest Act
(815 ILCS 205/1 et seq.)as amended.The provisions of this paragraph shall survive any expiration,
completion, and/or termination of this agreement.
•
8. SEVERABILITY. The terms of this agreement shall be severable. In the event any of the
terms or the provisions of this agreement are deemed to be void or otherwise unenforceable for
any reason, the remainder of this agreement shall remain in full force and effect.
9. COMPLIANCE WITH LAW. Notwithstanding any other provision of this agreement
it is expressly agreed and understood that in connection with the performance of this agreement,
Fire shall comply with all applicable, federal, state, city and other requirements of law, including,
but not limited to, any applicable requirements regarding prevailing wages, minimum wage,
workplace safety and legal status of employees. Without limiting the foregoing, Fire hereby
certifies, represents, and warrants to City that all of Fire's employees and/or agents who will be
providing products and/or services with respect to this agreement shall be legally authorized to
work in the United States. Fire shall also at its expense secure all permits and licenses, pay all
charges and fees, and give all notices necessary and incident to the due and lawful prosecution of
the work, and/or the products and/or services to be provided for in this agreement. City shall have
the right to audit any records in the possession or control of Fire to determine Fire's compliance
with the provisions of this section. In the event City proceeds with such an audit, Fire shall make
available to City, Fire's relevant records at no cost to City. City shall pay any and all costs
associated with any such audit.
10. PAYMENT. City shall pay ($259,118.00) Two Hundred Fifty-Nine Thousand, One
Hundred Eighteen and 00/100 dollars or($259,118.00) pursuant to Attachment A within thirty
(30)days of delivery or City's receipt of invoice. The aforementioned total sum is inclusive of all
freight, shipping and applicable taxes, which shall be at Fire's sole expense.
Fire shall accept in trade one (1) 2011 Wheeled Coach F450 Type 1 ambulance #
1FDUF4HTXBED05979, with 95,510 miles at evaluation for the value of $8,500.00. The
aforementioned ambulance must be in the same operating and physical condition as was on
the evaluation dated January 21, 2019. If not, the trade is void and the customer is
responsible for the trade value to be reimbursed to the Fire.
Fire shall provide a pre-payment discount of S1,500.00 if full payment is received within 5
days of the execution of this Agreement.
Net totals:
Ambulance as proposed $269,118.00
Trade Value ($ 8,500.00)
Pre-Pay Discount ($ 1,500.00)
Net purchase: 5259,118.00
All prices are less any applicable local,state,or federal taxes which may be applied to the apparatus
proposed.
2
NOTE: Payment shall be made only to:
Fire Service, Inc.
9545 North Industrial Drive
Saint John, Indiana 46373
11. TERMS OF PAYMENT.
F.O.B. St.John,IN. Zero down payment,full payment via wire transfer or municipal
check.
The purchase price payment reflects US dollars and does not include any authorized change
orders which, if applicable, shall be paid at time of final inspection and signed acceptance.
It is agreed that the ambulance and equipment covered by this contract shall remain the
property of Fire and shall not be placed in service until the full contract price has been paid.
12. DELIVERY. Fire shall complete delivery of all goods on or before October 31, 2020.
The ambulance shall be ready for delivery within approximately 120-160 calendar days, after the
receipt and signed acceptance of this contract,confirmed build order and chassis at the REV Group
Orlando Corporate Headquarters, Winter Park, FL. Fire shall not be liable for penalties and / or
delays due to strikes, failures to obtain materials, fires, accidents, force majeure, or any other
causes beyond the Fire's control.
In order to establish a stable design, procurement, and build schedule, City change order cutoff
date of eight (8) days from the date of the execution of this contract shall apply. Changes in major
components,configuration,or other items that may change the major components or configuration,
(e.g.: Chassis, Motor, Transmission, Wheel Base)shall not be allowed after the contract execution
date.
If inability to obtain exclusive or brand name materials causes completion or delivery problems,
Fire shall advise City of said problem.Fire resolves to examine alternative sources of said material.
Material substitutions shall be mutually agreed upon by City and Fire. No substitutions shall be
made without the execution of a written change order by City.
13. LIMITATION OF DAMAGES. In no event shall City be liable for any monetary
damages in excess of the purchase price contemplated by this agreement. In no event shall City be
liable for any consequential, special, or punitive damages resulting from loss of profit.
14. EXECUTION. This agreement may be executed in counterparts, each of which shall be
an original and all of which shall constitute one and the same agreement. For the purposes of
executing this agreement, any signed copy of this agreement transmitted by fax machine or e-mail
shall be treated in all manners and respects as an original document. The signature of any party
on a copy of this agreement transmitted by fax machine or e-mail shall be considered for these
purposes as an original signature and shall have the same legal effect as an original signature. Any
such faxed or e-mailed copy of this agreement shall be considered to have the same binding legal
effect as an original document. At the request of either party any fax or e-mail copy of this
agreement shall be re-executed by the parties in an original form. No party to this agreement shall
3
raise the use of fax machine or e-mail as a defense to this agreement and shall forever waive such
defense.
15. TRANSFER OF TITLE/RISK. Transfer of title, and risk of loss shall pass to City upon
delivery of the goods. All transportation and delivery shall be at Fire's sole expense.
16. CHANGE ORDERS. Changes to the contract may be requested by City after the
execution of the contract according to Section 2 of this document. Changes shall be reviewed for
cost and schedule impact by Fire. Changes shall be sequentially numbered. Change Orders shall
be prepared by Fire and executed by City. The price of the apparatus shall be adjusted to take into
account any Change Orders. Any and all Change Orders may extend the completion and
delivery of the ambulance.
17. SPECIFICATIONS. Fire agrees that all material and workmanship in and about this
apparatus shall comply with the original Wheeled Coach proposal dated January 9, 2020,
duplicating previous build #357921, and as described by Attachment B hereto.
(1) Wheeled Coach 2020 F450 Chassis Type I Custom Ambulance per City of Elgin
Specifications.
18. WARRANTY. Shall be as proposed in the attached Wheeled Coach specifications.
19. FIRE SERVICE, INC. requires, and City agrees, that the unit shall be inspected and/or
delivered within seven (7) days of notice that the unit had been completed.
20. CANCELLATION. This contract is subject to cancellation by City only upon payment to
Fire of reasonable cancellation charges, which shall take into account expenses already incurred
and commitments made by Fire.
This contract, to be binding, must be signed by an officer of Fire Service, Inc. or a person
authorized, in writing, by Fire Service, Inc. to do so.
21. TAG-ON / ADDITIONAL ORDERS. At its sole discretion, FIRE may allow the terms
of this contract to be extended to both City and similar agencies for the purchase of a similar unit(s)
under similar terms for a period of three (3) years from the date of the execution of this contract.
Should Fire choose to exercise this option, it shall be permitted to adjust the contract pricing to
account for equitable price adjustments associated with the change in the cost of the materials used
to produce the unit. Such adjustments will be based upon the Producer Price Index (PPI) for fire
trucks and / or heavy transportation equipment or by itemizing price changes expected by Fire
from the component vendors. If there are any changes between the unit(s) purchased via this
contract and any subsequent orders, those changes must be documented via properly signed and
executed change orders, including any necessary price adjustments. If the purchasing agency is
not the City, a separate contract will be required to complete the additional purchases.
This contract, including its appendices, embodies the entire understanding between the parties
relating to the subject matter contained herein and merges all prior discussions and agreements
between them. No agent or representative of Fire has authority to make any representations,
4
statements, warranties, or agreements not herein expressed and all modifications of amendments
of this agreement, including any appendices, must be in writing signed by an authorized
representative of each of the parties hereto.
No surety of any performance bond given by Fire to City in connection with this Agreement shall
be liable for any obligation of Fire arising under the Standard Warranty.
IN WITNESS WHEREOF. City and Fire have caused this contract to be executed by their
duly authorized representatives this 26th day of February , 2020
FIRE SERVICE, INC. r CI ; ' GIN
l e CCct
Print Nal Richard G. Kozal, City Manager
ignature
pp Attest
ig &I (f)/./..64
es>_ 113;4(.4 S City Cl
Title
F:\Legal Dept\Agreement\Purchase Agreement-Fire Service Inc-1-31-20
5
ATTACHMENT A
ftil.t_creiWiteZ
1i .
Jeff LeBeda,Vice President of Sales
Email:jeff@fireserviceinc.com
Website: www.fireserviceinc.com
January 9,2020 Office&Mobile: Phone: 630.546.5232
Service: Phone: 800.578.4281
(After hours) Phone: 219.808.2396
Fax: 219.3654090
PARTS: Phone: 800.578.4281
Fax: 219.365.4090
Acting Fire Chief Robb Cagann
City of Elgin Fire Department
550 Summit St
Elgin,IL 60120
Proposal
Chief,
Thank you for your continued interest in Fire Service, Inc, and the Wheeled Coach brand of ambulances. As requested,the
following is your proposal for a 2020 model year Ford F450 Type 1,Wheeled Coach modular ambulance. Proposal duplicates the
previous build#357921. Pricing includes pre-build,final inspection for 4 Elgin members,Stryker Power cot and delivery. This
proposal expires February 10,2020.
(1) 2020 Ford F450 Wheeled Coach Type I Modular Ambulance $269,118.00*
*Tag on Price to 2019 Contract between Elgin and Fire Service, Inc.02/22/2019
Trade Value,2011 Wheeled Coach VIN 1FDUF4HTXBED05979 ($8,500.00)
Purchase Price 2020 Ambulance • $260,618.00
• Pre-pay discount(due within 5 days of contract) ($ 1,500.00)
Net Purchase with Pre-Pay $259,118.00
Terms: Zero down,full balance at delivery. FOB St.John IN. Delivery Timeline 120-160 days past chassis arrival and confirmation.
As always, I am excited to begin the process with your team. Please let me know if you have any questions.
Thanks again for your continued business,
Ate cep
Jeff LeBeda
Vice President of Sales, EMS Division
Fire Service, Inc..
jeff@fireserviceinc.com
630-546-5232
1
ATTACHMENT B
QUOTATION Fire Service Inc.
Elgin Fire Department Fire Service, Inc.
Robert Cagann Jeff LeBeda
150 Dexter 1 Unit
Elgin, IL 60120 SHA,
January 28, 2020
Exp. Date: 02/28/2020
Quote No: Elgin New 2020 R3-0001
T1 - 170: 210160 STD Model: Type 1 Ford- 170"Module -#1170F
T1 - 170: 0990030STL Ford, F-450,193"WB,4x4, XLT,170", #1170F
T1 - 170: 200011 STD Type 1 Ford - 170" Module-#1170F
01/27/2020 18:26:44 Page 1
PART NO. S DESCRIPTION QTY - ID
== Ford, F-450,193"WB,4x4,XLT,170",#1170F-620.045 11/20/17== 1 WC
CHASSIS: 1 WC
00-10-4035 S < > Ford 2020 F-450, 4x4, XLT, 6.7L, 193"WB 2020-1 1 WC
SAP option 10508694
193"wheelbase
Auto throttle OEM Ford
Alternator OEM Ford
Mirrors, OEM, Heated/Remote
Cab seats OEM Captains chairs(no armrests)
05-00-0200 < Conversion, BOM, Type 1, 170 Module, F450 4x4 19-1 1 WC
Includes Liquid Spring Rear Suspension
CAB TO MODULE MOUNTING: 1 WC
10-10-1001 < > Bellows, Passthru, Unigrip, Fl 2008+, Std 1 WC
With Aluminum cab insert.
CHASSIS ADD-ONS: 1 WC
1F-30-7551 < Rear Suspension- Liquid Spring-2017+ F450, 4x4 1 WC
Dump Feature activated by the Left rear access door.
Override switch to be on right rear entry lower panel, top left of lower interior pa lel.
Ignition switch Hot.
Production note heat shrink wire connections at back of switch.
Per KKK, the rear suspension shall only lower the module when the vehicle is in park
and the parking brake is set.
Liquid spring control panel will be mounted on the front face of the CC, toward Dr.
side, use velcro to attach to the console, so the customer can easily remove and
adjust setting's, as needed, note not on side, on FRONT of console.
CHASSIS ADD ONS, MISC 1 WC
2F-71-4050 < Ignition Security System, Kussmaul, #091-160(Not Dodge) 1 WC
•
with switch located on dash
2F-71-7103 Cab Flooring, Black Rubber, 2009+, F350/450, OEM 1 WC
5F-10-SR01 X < Paint Wheels(5)ILOS 1
(SO-PT-351178)SR220147F
01/27/2020 18:26:44 Quote No: Elgin New 2020 R3-0001 Pase 2
PART NO - S DESCRIPTION QTY . ID
Pt Code Red#FRE 3015
(5)Wheels, Outer's and SPARE tire. (Both sides of Rim)
HEATING/AIR CONDITIONING: 1 WC
5U-10-0001 X < Splash/Cover over Elec Heater valves ILOS 1
(SO-CVR-351178)SR 218065F
A cover made out of aluminum to protect elec heater valve under compt A area.
5U-12-5000 > Hoses, Heater, No Max, to Rear, STD 1 WC
5U-12-SR01 X < 1/4 turn valves for heat hoses IATS electric controls. 1
(SO-HEAT-351032)SR 220147F
1/4 turn valves for heater hoses in under module by elec valves IATS electric controls.
5U-70-0107 < > Heat/AC, Fl, 2011+, Combo,w/Coolbar 1 WC
with thermostat in action area.
12vdc External Condenser, in Coolbar mounted on front
of module. Painted Red FRE3015
5U-92-1000 Master Control Digital Thermostat CM5000, ILOS 1 WC
BATTERY SWITCHES: 1 WC
60-22-1032 S < > Battery Sw,5 Min Timer F1, Fig 5B, (2)OEM Batt, (1)in RF ILOS 1 WC
(SO-BATT-351178) Elec Eng note same as 229833
Timer ILOS set up per Elec Eng for check out lights only. Batt sw will be ign only !
(2)Batteries under hood.
(1)Delco 1150 in RF ball compt on a tray IATS, note see battery charger also.
BATTERIES: 1 WC
60-30-5000 < Battery, Delco, 1150, (1) Each 1 WC
Lower RF compt
CONSOLES: 1 WC
7U-10-0602 < Console, Center, Pass-thru, Mica Finish, F1, CN11 1 WC
Eng note same as 229833
7U-10-7000 < Console, A/A, Wood, Angled 1 WC
Eng note same as 357921
CM300 thermostat. Top row 3 switches& 1 blank.
Bottom row 2 switches and 2 blanks Only.
ADDITIONAL CONSOLE IN CAB: 1 WC
7U-12-8500 Console, Map Pocket,Bolt on,at Rear,F1 1 WC
BULKHEAD CABINET: 1 WC
TF-50-SR00 X < > Bulkhead, Custom 1
(SO-BH-351178)SR220147F AC unit over pass through. Eng reference 229833
Pass through. Note DELETE lexan slider at pass through
(1) Bi fold Door for CB access to the driver's side of pass
through.
(1) Bi fold Door for PC board, above pass through
(1) Door under pass through same as 229833
WHEELCOVERS: 1 WC
No wheel covers, unit has painted rims.
01/27/2020 18:26:44 Quote No: EI•in New 2020 R3-0001 Pa•e 3
PART NO S DESCRIPTION QTY ID
X5-10-0002 X < Phoenix Air-Max AML1 valve extenders ILOS 1
(SO-VS-351178)SR220147F
Air Valve Ext only valve extenders, rear duals no wheel covers.
_=Type 1 Ford - 170"Module-#1170F-620.045 11/20/17== 1 WC
00-00-0247 < *******OUTSIDE GRAPHICS-24/7 ***"** 1 WC
Entry door panels.
00-05-0100 < This unit built in accordance with KKK-A1822-F CN 10 1 WC
This unit as specified meets all requirements of KKK-A1822-F Change notice 10.
All cabinets shall be labeled as to their capacity Rating.
35-05-0055 Type 1 - 170" Module-Standard Model Series 1 WC
35-05-0060 Type 1 - 170" Module General Body Construction Spec •
1 WC
35-05-0065 Type 1 - 170" Module Vehicle Body Structure Spec 1 WC
35-05-2000 < INTERIOR CABINETS-Duralite Construction, Wood, CN10 compliant 1 WC
All cabinets shall be labeled with their Rated Weight Capacity.
• MODULE BODIES: 1 WC
Eng note new for this unit compt A and recessed D cylinder storage in CS entry step
well for FW521 brackets
ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS
LAST UNIT 229833 COMPT a DOOR SIZE AND RF CABINET
35-10-0068 < Aisle Space, 50 inches, STD, Type 1, Std Model Only 1 WC
(49-50"actual)
•
Requires stainless steel wheelwell covers attached
to squad bench and basewall cabts that will
protrude up to 1.5" into aisleway on each side.
Install anti-slip decal with Wheeled Coach logo
on curbside and rear stainless steel thresholds, STD
35-10-0320 Module Skins, 0.125 inch 1 WC
35-10-0502 Headroom, 72 in. Type 1 - 170" module, #1170F/D 1 WC
35-11-0300 X Drop Skirt 6"each side forward of wheels 1
37-00-0350 < Coating, Polyurethane, Per compartment(1) Each •
6 WC
light gray
37-00-0360 Coating, Polyurethane, Rear Bumper Supports 1 WC
37-00-0361 X < Poly urea CS step area ILOS 1
SR 220147F(SAP# ) Delete lower SS threshold at door way.
See reference drawing's, black poly urea ILOS, contact sales ext 285 if you have any
question's
37-00-0600 < > Compartments, Sweepout 6 WC
•
All Compartments sweep out
37-00-0710 < Duraseam Doors, with Hidden Jambs 1 WC
- Magnetic door switches, Standard
39-A0-06SR XS < > A, Compt, Custom, Hoseline, 170" Module 1 WC
SR 220147F
ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMER'S
LAST UNIT 229833 COMPT A DOOR SIZE AND RF CABINET The upper A door
01/27/2020 18:26:44 Quote No: Elfin New 2020 R3-0001 Palle 4
PART NO S DESCRIPTION QTY ID
increases by 2.75" in height to match change of design on RF cabinet. De- er
requires a Modeled view of design for approval, prior to assembly
SR218065F Eng this is a change from customer's last units
El cabinet over-Drawer over E2 Cabinet
Upper compt A, with E2. (ISOS access) Eng upper A door sized to access E2 area
ONLY.
Lower compt for(2) battery tray.
Relocate Hose line HVAC unit over the pass through.
ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS
LAST UNIT 229833 COMPT a DOOR SIZE AND RF CABINET
39-B1-0155 B1, Compt, Std, 170" Module, 72" HR,.#1170F/D 1 WC
39-B2-0177 B2, Compt, Std, 170" Module, 72"H.R, #1170F/D 1 WC
39-D0-0155 < D, Compt, Mid Height, 170" Module, 72" H.R, #1170F/D 1 WC
Single door
•
39-E0-0105 < E, Compt, Std, 170" Module, #1170F/D 1 WC
Eng reference 229833
With Double Doors Eng note see AA tray
Unit will only have a slide out tray in AA, but will require space to bolt in a monitor on
the AA cabt above this dogleg.
Drop writing tray 3/4 on an inch below standard for inside height of 2.75" space to
allow 1/4 alum plate for defib mount in rearward end of AA, thru bolted.
39-F0-0305 < F, Compt, Std, Full Height, 170" Module, 72" H.R, #1170F/D 1 WC
Ref 351177
With Dogleg for Stairchair in Compt "F"(9.5"wide)
DOG LEG FOR STAIR CHAIR. Door to open past 90 degrees.
39-F0-0600 < >With Dogleg for Stairchair in Compt "F" 1 WC
DOG LEG FOR Stryker 6252 Chair.
FUEL FILL HOUSING: 1 WC
3A-10-1000 > Housing, Fuel Fill, Cast, F1/C1/D1/M2 1 WC
EXTERIOR DIVIDERS: 1 WC
3F-10-1103 < Divider, Vertical, B2, 3/16"Thick, Std Model only 1 WC
compt"B2", 10.5"off wall #1 (Fixed) HHilitlil
3F-10-2000 < Divider, Vertical, (1), LF, Full Height 1 WC
Full Depth Compt F mounted at edge of dogleg.
1/2 height divider, mounted wall 2&ceiling.
Customer requires lower area of compt to be clear for stair chair storage. Same as
229833
SHELF-COMPARTMENT"A"/RF CABINET: 1 WC
3F-20-1000 < > Shelf,Adjustable,(1), RF Cabt Custom 1 WC
(1)RF Compt"A"/cabt"El"area, centered. Just above knox box cabinet.
•
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 5
PART NO S DESCRIPTION QTY ID
Eng note change for 2019 shelf from wall 1 to wall 3 of upper cabinet, below upper
cabt dogleg that's on wall 3 and above knox box closeout.
3F-20-1500 < > Shelf, Additional, Adjustable, (1), RF Cab Custom 1 WC
RF Compt"A"/cabt"E2"area evenly spaced.
SHELF-COMPARTMENT "B"/"B1": 1 WC
3F-30-1000 < > Shelf, Custom, Adj, Cmpt "B", (1) 1 WC
From divider to all 3 approx 44"above finished floor
SHELF-COMPARTMENT "D": 1 WC
3F-40-3001 < > Shelf, Custom,Adj, Cmpt"D", (1), Std Model only 1 WC
Just above scba brackets
•
SHELF-COMPARTMENT "E": 1 WC
3F-50-0200 < Shelf, Fixed, Cmpt E, for Electrical storage, No Divider 1 WC
Elec Eng note relocate GFI breaker box to compt E, on wall 1 of compt, up high ab pve
Elec shelf, toward outer edge of shelf for easy access, trim elec overflow cage so the
customer can reset breaker easily if needed.
SHELF- COMPARTMENT "F": 1 WC
3F-60-6000 < > Shelf, Custom,Adj, Cmpt "F", (1) 1 WC
Wall 1 to divider above stair chair height
3F-60-6500 < > Shelf, Custom,Adj, Cmpt"F", (1), Additional 1 WC
Wall 3 to divider above 02 window height
COMPARTMENT/SHELF, MISC: 1 WC
3F-70-1710 < > Reinforcement, Compartment Wall, For SCBA Bracket 1 WC
Wall 2 Compt D for 3 scba brackets, 2 in corners and 1 on wall 2, between the 2 in the
corners.
WINDOWS: . 1 WC
3P-10-5201 > Window,Upper,CS/Slider,Rr/Fixed,Priv Tint,PAN,Std Model only 1 WC
MODULE ENTRY DOOR HANDLES: 1 WC
3U-30-8000 Handles, Patient Entry, Trimark Black/Chrome "SafePass"STD 1 WC
EXTERIOR COMPT DOOR HANDLES: 1 WC
3U-40-0510 > Handle, Module Compt, Trimark, Black/Chrome, STD 6 WC
3U-40-0514 < > Latch, Paddle, Trimark, For Trailing Door 1 WC
compt"E"
3U-60-0100 > ELECTRIC DOOR LOCK PACKAGE OPTIONS: Click to add 1 WC
3U-60-1390 < > Door Locks,Electric, Trimark, (1)DOOR, Entry Door 2 WC
Module entry doors.
3U-60-1400 < > Door Locks,Electric, Trimark, (1)DOOR, Compt Door 6 WC
All module compts(except battery compt)
3U-60-1500 < > Switch,Momentary Rocker,Activate Elect Door Locks 1 WC
Installed on C/S wall at head of S/B close to CS door, next sw rearward will be the
timer switch.
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 6
PART NO S DESCRIPTION QTY ID
3U-60-2500 < > Switch, Stealth, Cab/Mod Doors 1 WC
In grille on passenger's side.
• 3U-60-3000 > Relay Control Circuit, Electric Locks 1 WC
3U-60-3002 < > Intermotive CAN module for 2017+ Ford F-series 1 WC
Required for Stealth switch operation on F series.
3U-60-5200 Circuit, OEM Door Lock to activate Mod Doors(Not Dodge) 1 WC
DOOR HOLD OPENS: 1 WC
40-10-1611 < > Hold Opens,Rr Doors,Cast,Grabber(2), 5.5", Std Model only 1 WC
- Installed so doors will open as wide as possible •
- Mount at Bottom of doors.
40-10-7200 < Hold Open, Gas Strut, Ext Compt, 301b, Std 1 WC
Compt B1
40-10-7205 Hold Open, Gas Strut, RF Compt, 30lb, Std 1 WC
40-10-7206 < Hold Open, Gas Strut,Comp Door Only,110 Degree,301b,ILOS 5 WC
(5)Compartments B2-D-E-F
40-10-7750 < Holdopen, Gas Strut, CS Entry Door, 35#Standard. 1 WC
New Code Per ECN 1823 •
DOOR PANELS: 1 WC
45-10-0001 X < Panels, Entry, Durasafe, Stainless Steel, w/Chevrons, ILOS 1 .
(SO-PANEL-351178)SR220147F
Alum center panels will be covered with diamond grade NFPA Red/Yellow 4" chevron
striping by 24/7, 45 degree angle to match rear of module.
FENDER FLARES: 1 WC
4A-10-1001 Flare, Fender, Rear, Black Rubber, Std Model only 1 WC
BUMPERS: 1 WC
4F-10-20SR X < Bumper,Rear,w/Skids& Flip Up,F1,w/LED DOT Lts, 12" ILOS 1
(SO-BMPR-351178)SR220147F
12 INCH DEEP BUMPER ILOS w/Gator Grip on flip up step.
RUNNING BOARDS: 1 WC
4K-10-2112 < Running Boards, Standard, 2017+ F450,w/Gator Grip, #1153F11170F 1 WC
NOTE LED Lights in front stone guard!! Adjust light, as needed due to runring
boards.
SKIRTRAILS 1 WC
4U-10-9250 < Skirtrails,Extruded "C"channel(E-one Style) ILOS 1 WC
Rub Rails, Skirtline, One(1)set"C" Channel, 3"Style ILOS
PROD NOTE CS FRONT SKIRT RAIL 2 PIECE, CUT TO BE CLEAR OF CS ENTRY
ZICO STEP, REAR SECTION FROM REAR OF STEP TO WHEEL WELL AND
FRONT SECTION FROM FRONT OF STEP TO FRONT CORNER POST, CALL 285
IF YOU HAVE ANY QUESTIONS.
45 degree cut on all ends of skirt rails, std
STONE GUARDS (FRONT): 1 WC
Mech Eng change NO full height corn caps
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pase 7
PART NO S DESCRIPTION QTY ID
4U-11-5000 Stone Guard, Front, Dia Plate, 17" 1 WC
KICKPLATES (w/STD. REAR STONEGUARDS): 1 WC '
50-10-2105 < Kickplate, W/Recess, No Light Holes,Duraseam 1 WC
NO tow eyes
MODULE ADD-ONS: 1 WC
55-10-0001 X < Splash Plate,Urea Tank FiII,Stainless Steel,'011+ "F"-Series IATS 1 •
(SO-SPLSH-351178)SR220147F
55-10-0002 X < Splash Plate, Fuel Fill, Stainless Steel, IATS 1
SR 220147F (SO-FUEL-351178)Same as ZZ-20-1A60
•
55-10-00SR X < Flatbar for dealer installed anode plate 1
SR#220147F reference only recent unit 333084
Add (2) pieces of flat bar for dealer installed anode plate. Reference drawing
#381391D for flat bar and reference location. Placement dependant on chassis.
NOTE: Do not undercoat these plates! Plates to remain raw aluminum!
55-10-3000 < Holder, License Plate, Cast, LP0002, STD 1 WC
-in rear kick plate, centered
Important shop note install a ground wire attached from tag recess to chassis frame
rail !!
SILL PROTECTORS 1 WC
No sill protector at CS entry door, doorjamb will have black polyurea ILOS
55-30-4001 Sill Protectors, Stainless, All Compts, Std Model only 1 WC
MODULE STEPWELL: 1 WC
Eng note recessed at wall lfor(2) D cylinder storage cabinet at head of squad bench.
55-90-6000 Stepwell, Double Step, ILOS, Type 1 1 WC
MUD FLAPS: 1 WC
5A-10-1001 Mud Flaps, Rear, W/Logo, Std Model only 1 WC
PAINT/BELTS: 1 WC
See (SO-PT-351178)SR218065F Same as 229833
Pt Code Red#FRE 3015
(5)Wheels, Outer's and SPARE tire. (Both sides of Rim)
Black polyurea CS entry door jamb ILOS call extension 285 for information if needed.
5F-10-3200 < > Paint, Entire Unit, Red or Metallic Upcharge 1 WC
Reference 229833
Color: RED Sikkens paint code#FRE3015
Module Roof and Drip Rail OEM White FA91:YZ
Ref pics on server in wo folder
CHEVRON PACKAGES INSTALLED: 1 WC
Rear chevron installed by dealer Fire Service.
DECAL PACKAGES INSTALLED: 1 WC
5P-10-5001 Roof Star, White Border, Installed, Std Model Only 1 WC
ELECTRICAL SYSTEM: Circuitboard 1 WC
Reference only 229833
COAX CABLES/ANTENNAS: 1 WC
Reference previous unit 229833
SEE AMB ANTENNA PLACEMENT pdf in FILE (5 Ports)
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Page 8
PART NO S •
DESCRIPTION QTY ID
65-10-0001 X < Install Customer Supplied Antenna 1
SR220147F art will be delivered to production when ready call Ext 285.
(1)Port 2. Terminate tails at circuit board. Tag Elgin#2
AP-CCWG-Q-S2222-RP3-BL
65-10-SR01 X < Specified Antenna installed SR 218065F 1
(SO-ANT-351178)SR220147F Ref 229833
Laird Al 50S
(1)Port 3 to terminate at the circuit board (Tag Elgin #3)
(1) Port 6 to terminate at the circuit board (Tag Elgin#6)
Laird Al 50S VHF unity gain antenna with spring plus associated nmo mount
Laird TRA 7603
(1)Port 4 to terminate at the circuit board. (Tag Elgin#4)
Laird TRA7603 UHF 3db low profile antenna plus associated nmo mount instal ed
ILOS 70176- Laird TRA4503: 450-470 Phantom Antenna. White RF
Cable with NMOK Motorola Style roof connector
Laird 4503
(1)Port 5 to terminate at circuit board. (Tag Elgin#5)
Laird TRA4503 7/800 MHz 3db low profile antenna plus associated nmo mount ILOS
304196-Laird TRA7603: 760-870 Phantom Antenna, White RF Cable with NMOK
Motorola Style roof connector
12VDC POWER SOURCES&OUTLETS: 1 WC
6A-22-200E < > Outlet, Cigar Lighter, STD, (2), A/A 1 WC
• 20-amp ignition hot circuit. ("elect batt sw")
6A-22-2500 < >•Outlet, Cigar Lighter, IATS, (1) 1 WC
Constant hot
RF Cabinet El Wall 2 up high and to right.
6A-22-5100 < Outlet, Dual USB Port, 5VDC, 2.1Amp output, Standard 1 WC
Located on the passenger side of the center console, per Electrical Engineering
6A-22-5150 < Outlet, Dual USB Port, 5VDC, 2.1Amp output, TATS 1 WC
Location AA
POWER SOURCE, 12 VDC 1 WC
6A-23-0910 < Power Source, 12VDC, 20A, Ignition/Shoreline Hot 1 WC
(1)pre-wire coil and tagged in action area
(1)pre-wire coil and tagged behind driver's seat.
6A-23-0950 . < > Power Source,12 VDC,10 Amp(+-) 7 WC
(1)Constant Hot to cab console
(1) Ignition hot to cab console
(2)Constant Hot to circuit board
(1)Constant hot to behind AA SW panel
(1) Ignition Hot to behind AA SW panel
(1)Constant Hot to RF cabt El knox box cabinet
6A-23-2200 < > Power Source,12 VDC,20 Amp(+-) 1 WC
(1)Constant Hot to cab console
6A-23-3000 < > Power Source,12 VDC,30 Amp (+-) 1 WC
Constant Hot Terminate in circuit board cabinet with 6'tail.
01/27/2020 18:26:45 Quote No: El in New 2020 R3-0001 Page 9
PART NO S DESCRIPTION QTY ID
6A-23-3001 < > Power Source,12 VDC,30 Amp(+-), Std Model only 1 WC
-Constant Hot, to terminate in circuit board cabinet
-with 6 foot tails(hot and ground).
ELECTRICAL ACCESSORIES 1 WC
6E-10-0001 X < Install Med Vault Mini Customer supplied 1
(CS229833)SR 220147F
Install customer supplied Med vault mini 5201in RF cabinet
El bottom left corner see ref drawing's. Call Ext 285 for delivery of part. Change for
Eng see RF cabt change's
6E-10-44SR X < Camera, Hanscom K#HC430RVM rearview mirror 1
(SAP# 10184826)SR220147F
make sure mirror bracket fits on a 2019 F450
Mount camera exterior on rear of module, off center
toward driver's side. above rear entry door.
(1)#HC430RVM rearview mirror with 4.3" integral monitor,
(1)#IR250 Camera, BLACK, with 35'of cable.
SHORELINE INLETS: 1 WC
6F-90-4105 < > Super Auto Eject, 20 amp, ILOS, Red, Std Model Only 1 WC
Mounted above compartment"E"
Elec Eng note relocate GFI breaker box to compt E, on wall 1 of compt, up high above
Elec shelf, toward outer edge of shelf for easy access, trim elec overflow cage so the
customer can reset breaker easily if needed.
125 VAC OUTLETS: 1 WC
6K-40-1000 < Outlet, 125 VAC, Duplex, (2), STD 1 WC
-(1)outlet in action area
-(1)outlet in the RF Cabinet"El". wall#2, upper right up high by cigar outlet.
6K-40-2000 < > Outlet, 125 VAC, Duplex, IATS 1 WC
(1)AA down low at REAR end of AA by CPR Seat
BATTERY CHARGERS: 1 WC
6U-10-0100 < > Circuit, Battery. Charger Power Acces. 1 WC
110 Relay to switch to 12VDC power.
6U-10-1600 < > Battery Charger,Kussmaul, Auto 1200,40 amp W/Rem Ind 1 WC
Charger/Conditioner
MOUNTED IN BATTERY COMPT as in previous 229833
Circuit breaker for the charger wiring MUST be 80 amp inline.
Kussmaul remote indicator panel installed next to SL inlet above E (Wired per ELEC
ENG 80 amp breaker)
GAUGES/METERS: 1 WC
D0-10-1200 < Meter,Analog, Volts, Fl 1 WC
On center console SWITCH panel
D0-10-6500 < Alarm, Low Voltage, AudioNisual 1 WC
Light in cab console and Buzzer in cab.
01/27/2020 18:26:45 Quote No: EI•in New 2020 R3-0001 Pa•e 10
PART NO S DESCRIPTION QTY ID
SEQUENCING/LOAD MANAGEMENT: 1 WC
ENG NOTE: Same as 229833, Engineering note see customer reference pics on
server:
DA-11-3000 < > Sequencer,Kussmaul,Load Manager, W/Switch 1 WC
Eng ref 229833
W/Sequencer switch and override on console
SIREN SPEAKERS: 1 WC
DF-10-1242 < Siren Speakers, Cast SAD/PSAD3815-17FSD-1;FRD'17+, Fl, Std 1 WC
Thru Front Bumper
SIRENS: 1 WC
DK-10-1400 > Siren, Whelen, WS-295-SLSA1, Standard 1 WC
AIR HORNS: 1 WC
DP-10-3100 >Additional,Air Tank,For Buell Air Horns 1 WC
DP-10-9100 < >Airhorn, Buell, 5440 comp, 10 & 12 inch horns 1 WC
mount compressor on fixed shelf in compt"E"
DP-10-9215 < > Brackets,Airhorn_Under Front Bumper, F-Series, 2017+ 1 WC
Brackets Per Eng design
Under front bumper through plastic fairing.
SWITCHING OPTIONS FOR AIR HORNS&SIRENS: 1 WC
DP-11-1000 Switch, Siren/Horn Thru Horn Ring 1 WC
DP-11-5500 < > Switch,Add, 12VDC Momentary Rocker. 2 WC
CC Switch panel driver and passenger side, (Air horns)
Same as 229833
SWITCHES ADDITIONAL: 1 WC
DU-10-2500 < > Switch, 12VDC, Rocker, Amber, Additional 1 WC
10 Amp constant hot
Additional switch in cab console, terminate wires in CB cabt with 6 ft tail, tag wire i i CB
cabt Wi Fi.
DU-10-3100 < > 3-Way Switch, Dome Master Circuit •2 WC
(1)switch in ECC
(1)switch in action area
DU-10-6000 < > Switch, Momentary, Rocker, (1) 1 WC
Reference 351177
In AA Lower panel to activate 15 minute check out timer
IATS, to allow activation and de- activation. Wire to all dome lights in liner- HIGH
intensity.
AUDIBLE ALARMS: 1 WC
F0-11-3501 Alarm, Back-Up, Auto Reset, Std Model only 1 WC
VEHICLE EXTERIOR LIGHTING 1 WC
Elec Eng note, minimal of 15 amp breakers for exterior lights per Elec Eng discretion.
F3-10-00SR X < Emitter, Tomar#EMIT20-LBUG 1
(SO-OPTI-351178)SR220147F
Inst in Cool Bar, Center, above center clear.
Tomar#EMIT20-LBUG Preemption Emitter
Separate switch prim only and in gear only.
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Page 11
•
PART NO S DESCRIPTION QTY ID
F3-10-14SR X < Chrome Bezel, Tomar#RECT-37-SMFP - 1
(SO-LT13-351178)SR220147F for Emitter lamp
FF-13-SR01 X < Whelen TANF 85 LED Lightstick 1
(SO-TA-351178)SR220147F Same as 229833
Whelen TANF85 8-lamp linear-LED Traffic Adviser, approx 46.75" long, TACT.D1
control head.
mounted above load lights •
Mount control head in cab per Engineering.
• WHELEN FLANGES FOR 9E SERIES LIGHTS: 1 WC
FU-38-0100 Flange, Super 9L, #90FLANGC, (1)Each 16 WC
< > WHELEN SUPER LED 9L STEADY BURN LIGHTS 11,3,9: 1 WC
Elec Eng note, minimal of 15 amp breakers for exterior lights per Elec Eng discretion.
FU-40-0500 < > Light, 9L, Super LED, Whelen, Red,Red Lens,ILOS, 90RR5SRR 8 WC
(2)Each side standard locations
(2) Front Module upper outer corners
(2)Rear Module upper outer corners
PRI/SEC thru AFM 560
FU-40-0501 < > Light, 9L, Super LED, Whelen,Red,Red Lens,IATS, 90RR5SRR 4 WC
(2)to show thru lower rear windows
PRI?SEC thru AFM 560
(2)Cool Bar one each side of center clear
PRI/SEC thru AFM 560
FU-40-0512 < > Light, 9L, Super LED, Whelen,Amber,Amber Lens,ILOS, 90AA5SAR 1 WC
(1) ILOS relocated to upper rear window show thru CS
PRI/SEC thru AFM 560
FU-40-0513 < > Light, 9L, Super LED, Whelen,Amber,Amber Lens,IATS, 90AA5SAR 1 WC
SS rear window upper show thru •
PRI/SEC thru AFM 560
FU-40-0535 < > Light, 9L, Super LED, Whelen, R/C, Clear Lens,IATS, 90RC5SCR 2 WC
(2) IATS Cool Bar angles pods
PRI ONLY NFPA thru AFM 560 •
5 SERIES(TIR6) SPLIT LED LIGHTS: 1 WC
H4-05-5705 < > Light;5L TIR6, Whelen, Red, Red Lens,50RR3ZRR, IATS 3 WC
(3) Installed on the Rear and CS Entry door interior panels, lower outer corner.
Wired Ignition Hot, to flash when door is open, thru internal flasher, factory default.
5 SERIES(LIN6) NON-SPLIT LED LIGHTS: 1 WC
H4-06-5702 < > Light,5L LIN6,Whelen,Red,Red Lens,50R02ZRR, Std, F1/D1 Only 2 WC
(2)as grille lights
wired thru AFM560 flasher Prim Only Shut down in Park/Neutral
WHELEN 5E FLANGES/HOUSINGS: 1 WC
H4-10-0044 > Housing, 5L Series,#5LSMAC, (1),Std, F1/D1 Only 2 WC
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pase 12
PART NO S DESCRIPTION QTY ID
H4-10-0045 > Housing, 5L Series, #5LSMAC, (1) 3 WC
WHELEN SUPER LED 7L LIGHTS W/FLASHERS: 1 WC
H5-58-0315 < > Light, 7L, Super LED, Whelen, Red, Red Lens, IATS, 70R02FRR 2 WC
Over rear wheels
PRI Only NFPA thru AFM 560
H5-58-0375 < > Light, 7L, Super LED, Whelen, Clear LED, IATS, 70CO2FCR 1 WC
ILOS Center Clear 7 series under Tomar 7 emitter lamp in cool bar.
PRI ONLY- NFPA thru AFM 560
WHELEN FLANGES 7 SERIES LIGHTS 1 WC
H5-59-1000 < Flange, Whelen, For 7E lights(1), Mods 5 WC
- For 7 Series Lights
INTERSECTION LIGHTS, FORD &Chevy Type 1,WHELEN 1 WC
H5-59-500E < Light, Whelen;LINZ6R, LED-Red, Std 2 WC
with chrome flanges
(2)front intersectors
PRI ONLY NFPA internal flasher
•
•
CORNER CAP LIGHTS 1 WC
HF-11-6049 < Corner Cap Lts,Multi-LED,(2)Amber(2)Red w/Flashers,Std Model 1 WC
- High intensity flashers; switched Pri/Sec. NO switch
CLEARANCE LIGHTS: 1 WC
HF-12-9100 < Light, Clearance,Amber LED, ILOS 3 WC
-On front as clearance lights.
HF-12-9601 < Light, Clearance, Red LED, Std Model only 3 WC
-On rear as clearance lights.
SCENE AND LOAD LIGHTS 1 WC
HK-20-110M < Light, LED, Whelen, Clear, #9SCOENZR, 24 LED, ILOS, (1)W/Chrome Flange . 4 WC
(2)each side as scene lights
HK-20-250F < > Light, Whelen, 700 Series, 12LED, Scene Light, ILOS 2 WC
Rear loads under the traffic advisor See drawings
HK-20-7100 > Scene Lights, C/S, Activated W/C/S Door 1 WC
HK-20-7400 < > Rear Scene Lts Activate W/Rev Gear. 1 WC
Rear load lights wired to reverse standard.
FLASH PATTERN WARNING LIGHTS: 1 WC
HU-11-2500 < Brake Override Circuit 1 WC
Rear window lower RED
HU-11-8500 < > Automatic Secondary, Park/Neutral, W/Momentary Switch, Auto Reset 1 WC
the circuit would automatically reset when the gear shift lever is placed back into gear.
WARNING LIGHT FLASHERS 1 WC
HU-24-7500 < > Flasher, Whelen AFM-560, ILOS 1 WC
Set flash pattern to Comet Flash
01/27/2020 18:26:45 Quote No: El.in New 2020 R3-0001 Pase 13
PART NO S DESCRIPTION QTY ID
HARNESS LAYOUT: 1 WC
J5-12-1000 Halogen, " E " Spec, Whelen 1 WC
STOP/TURN/TAIL LIGHTS: 1 WC
JA-10-1200 < Light, License Tag, (2), Trucklite#15205 LED, ILOS 1 WC
Run ground wire from tag recess, to frame rail ILOS.
JA-13-8010 < Tailights, Whelen,LED Stop/Tail,Halogen/Backup,w/WC logo 1 WC
Brake-Alert Flash before the steady Burn
Turn Arrow—sequential arrow
MODULE OVERHEAD HEADLINER: 1 WC
SEE Ambulance Antenna Placement pdf in file
JK-10-6510 < Headliner, Flat, PVC,w/Hinged trough cover, 160"+ MAV/T1 1 WC
5 antenna ports ILOS. Ref only 229833
12VDC INTERIOR LIGHTING: 1 WC
ELEC ENGINEERING NOTE
1 HI- Low-Off switch in AA panel to turn all liner dome lights on and off!
JP-10-0611 < Lights, Dome, LED, Whelen,White Fing, (4)S/S, (3)C/S, ILOS 1 WC
NOTE: NO VISABLE FASTENERS OR HOLES.
JP-10-0621 < Light, Dome, LED, Whelen,White FIng,(1) IATS 3 WC
F. G,H
JP-10-7015 < Light, Stepwell, LED, Whelen#TOCACCCR, 2in, ILOS 1 WC
Wall 3 ILOS, due to recess at hd of bench.
JP-10-8030 < Light, Intertek ZY-PIR38 12v, LED, In A/A ILOS 1 WC
Install on bottom of L cabinets i!!!
JP-11-4700 NO lighting recessed into trough cover-Standard 1 WC
LIGHTS & MISCELLANEOUS: 1 WC
JR-50-2700 < > Lights,(2), 4in, LED, to Ilium Running Boards, Constant Hot 1 WC
relocate light upward to avoid obstruction from runnign board flange!!!
•
Activated with the cab doors.
•
JR-50-2885 < Lighting, Compt, LED Hi-Brite Flex, ILOS 1 WC
both vertical edges near door jambs and across top edge
near door jamb, compts"A", "B1", "B2", "D", "E", & "F".
Retain 2"02 light.
JR-50-30SR X < Spotlight, Go Light, Black, #2021 1
(SO-GOLT-351032)SR220147F
Mount Go-Light in cab roof- centered. Toggle Control to be in CC switch panel at top
close to the passenger.
JR-60-2003 < > Timer, Momentary Sw,15 Minute, Constant Hot, Std Model only 1 WC
Momentary SW for timer 229833, see added momentary switch.
Mount switch on C/S wall at the head of the squad bench
•
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 14
PART NO S DESCRIPTION QTY ID
in the standard location. Switch to allow activation and
also deactivation. Wire to all dome lights in liner, HIGH
JR-70-0005 < Light, in Circuit Board Area, for Electrical Troubleshooting 1 WC
-with integral switch; wired constant hot.
CLOCKS: 1 WC
L0-10-1500 < > Clock, Analog, Self Cont, 12/24 Hr, 8" 1 WC
LOCATION: CSR cabinet see ref drawing
SUCTION PUMPS: 1 WC
LP-10-0500 Suction Pump, Standard 1 WC
INSULATION: 1 WC
LU-10-3001 < > Insulation, Severe Weather Package 1 WC
one inch block foam in modular walls and roof covered with reflective insulation.
Under Floor to be Spray Foam insulated after the production assembly process is
complete by 24/7.
All edges of reflective insulation on walls and ceiling must'be taped, std.
GRABRAIL(S)/GRABHANDLES: 1 WC
• N0-10-9101 < Grabrail,Overhead,117",Handicap Style,Yellow,Std Model Only 1 WC
•
Yellow Powder Coat Finish
N0-10-9703 < Handrails,(3),Custom "L"Shape,1",Yellow,Entry Drs,Std Model 1 WC
Yellow Powder Coat Finish Stainless Steel Grab Handles •
N0-11-1500 < > Grabhandle, 1"X 13.5", Aluminum, (1), On Exterior, IATS 1 WC
Outside CS entry Door
PAINTED to match module job color Red#FR#3015
02 CYLINDER RACKS: 1 WC
NA-10-3550 < Rack, Multiversal,#QR-MV, W/Straps 1 WC
Wall 2 near wall 3
NA-10-6502 Track, Unistrut for Oxygen Rack-Standard per ECN 1 WC
02 SYSTEMS COMPLETE: 1 WC
NF-51-2000 < > 02 Sys, LF Stor, (2)O2/Vac Port-NA, (1)02-Liner, (1)02 C/S 1 WC
SEE REF DRAWING AA Layout 02-02-VAC (vac port close to suction container.)
Same as 229833
ohio style
(2)oxygen outlets in action area
(1)vacuum port in action area(Down low close to suction container see ref drawing)
(1)oxygen outlet in liner at head of cot
(1)oxygen outlet cs wall at head of squad bench
02 SYSTEM PARTS: 1 WC
P0-59-7500 Regulator, Oxygen Cylinder, Preset 50PSI, Installed 1 WC
SUCTION CONTAINERS: 1 WC
PA-10-7003 < > Regulator/Holder, SSCOR 23002 with Canister clip-CN 10 Compliant 1 WC
Conforms to J3043 requirements
' Relocate forward in AA to under the AA switch panel, see drawings for reference.
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa•e 15
PART NO S DESCRIPTION - QTY ID
COT MOUNTS: - 1 WC
PF-26-3500 < Stryker Power Load- No Wheel Guide-Change Notice 8- COMPLIANT 1 WC
includes constant hot power supply for battery charging.
IV HOOKS: 1 WC
PP-20-1000 < > IV Hook, Perko, (1), W/Straps, STD 2 WC
curbside and streetside standard locations
PP-20-9000 < > IV Hook, Cast, Fold Down Recessed, IATS 2 WC
IV2 SS and IV2 CS
KICK PLATES STAINLESS STEEL, ON CABINETS: 1 WC
PU-10-1001 X < Kickplate, Brushed S/S, Face Of Squad Bench ILOS 1
Customer request New Eng drawing#381728d rev a
Full Height on squad bench Ref pics on server reference 229833.
PU-10-2000 Kickplate, 8" Brushed S/S, On Face of Basewall 1 WC
MISC. INSTALLED HARDWARE/EQUIPMENT: 1 WC
R5-10-0001 X < Ferno#2746-43208 Ferno D.360 Swivel defibrillator mount 1
(SAP# )SR218370F
Rearward end of AA mount per cust ref drawing on server in work order folder.
Ferno#2746-43208 Ferno D.360 Swivel defibrillator mount
R5-10-2000 . < > Bracket, SCBA, Ziamatic, UN-6-30-3-F-CRS 3 WC
Compt D on corner brackets and 1 centered on wall 2 down low.
See reference picture on server in wo folder
R5-10-8000 < > Wrench, Oxygen, Tethered, Mods 1 WC
in oxygen compt.
R5-11-5710 < Seatbelt, Assy, (4 Point), Per4Max, Black, (1)Each -CN-8 3 WC
Above the Lid installation
(1)for CPR side seat
(2)for squad bench
R5-12-SR00 X < Bracket, Zico, SCBA,Angled 2
(SO-BRKT-341057)SR220147F
(2)Compt"D", floor level 1 ea corner.
DRI-DECK/TURTLETILE: 1 WC
RA-10-2000 > Dri Deck, Black, All compt. Floors and Shelves 1 WC
HOLDER, CYLINDER: 1 WC
RF-11-6050 < > Holder, Cylinder, Single, Zico QR-D-2 Strapless, -CN 10 Certified 2 WC
(2) Mounted at head of bench in recessed cabt.
STRAPS, INSTALLED: 1 WC
RK-13-3500 < Seat Belt, Across Compt Opening 1 WC
Compt F, wall 1 to wall 2 to hold stair chair in place.
Leave 4 inch tail for strap adjustment
MODULE INTERIOR 1 WC
RU-05-0000 Interior Cabinets- Duralite Construction, Wood-CN 10 Compliant 1 WC
MICA COLOR: 1 WC
01/27/2020 18:26:45 Quote No: El.in New 2020 R3-0001 Pase 16
PART NO. S DESCRIPTION QTY ID
RU-14-1900 Mica,Dove Gray Over Pewter Brush 1 WC
SUB FLOORING: 1 WC
RZ-99-0050 Flooring, Wood, Type 1, Std . 1 WC
FLOORING: 1 WC
T0-11-8201 Flooring, Lonplate II,Gunpowder Grey#424TX, Std Model only 1 WC
SEAMLESS ATTENDANT SEATS: 1 WC
T5-10-5111 < Seat,Attendant, EVS, Child,Gunmetal#1880CB, Std Model only 1 WC
Seat location same as 229833.
Vacuum formed EVS1880CB w/3 point seatbelt.
Integrated child safety seat.
Mounted metal box base. Opening faces toward the rear.
SEAMLESS UPHOLSTERY: 1 WC
T5-25-0500 Uph, Smless, Gunmetal,No Bio,No Post&Wheel 1 WC
CUSHIONS: 1 WC
T5-40-2106 > Upholstery, Backrest Cushion, EVS, Gunmetal,w/WC Logo 3 WC
02 DOOR: 1 WC
TK-10-5000 > Lexan Flap W/Hinge 1 WC
GLOVE HOLDERS: 1 WC
TN-20-1001 < > Cabinet, Glove Box Holder,(3),Above C/S door, Std Model only 1 WC
Must use M1 latches for KKK Change notice 10 compliance
RIGHT FRONT CABINET: 1 WC
ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMER'S
LAST UNIT 229833
Note set Knox box cabinet back, Austin Gen 2 doors will close over knox box,
decrease depth of knox cabt, and leave the back open, close out will be 2 inches
deeper than the depth of the knox box, space behind this close out will be used for
storage.
TU-20-14SR XS < > Cab, RF, W/O Healthguard, AC/Combo, Custom 1 WC
REF ONLY(SAP#10522451)SR220147F
New for this unit ! See NEW drawing. •
El Inside access only(Upper)
Drawer center section
E2 Inside/Outside access(Lower)
Eng note close out bottom left area of El at Wall 1 for a Med vault mini un flanged and
recessed style medvault.
Medvault will sit behind door, close out to be 2 " longer than medvault, New snit
change for 357921! Call 285 if needed
ENGINEERING DESIGN CHANGE ON THIS 2019 UNIT FROM CUSTOMERS
LAST UNIT 229833
Note set Knox box cabinet back, Austin Gen 2 doors will close over knox box,
decrease depth of knox cabt, and leave the back open, close out will be 2 inches
deeper than.the depth of the knox box, space behind this close out will be used for
storage.
RF CABINET DOORS W/COMBO NC 1 WC
TU-20-8430 < Doors, RF, Upper, Dual Gen II OHO, Polycarbonate Doors, Gray, VA style 1 WC
RF cabt El
01/27/2020 18:26:45 Quote No: Elgin New 2020 R3-0001 Pa.e 17
PART NO S DESCRIPTION QTY ID
TU-20-8530 < Doors, RF, Lower, Dual Gen II OHO, Polycarbonate Doors, Gray, VA style 1 WC
RF cabt E2
HARDWARE,LATCHES AND LOCKS: 1 WC
V0-10-1000 < > Handle, C, Pull, Installed, (1) Each, IATS 1 WC
AA tray
V0-14-2075 < > Latch, Southco M1, 2IN S/S, (3/4"door)Non-Locking, (1), CN 10-Rated at 10Ibs 3 WC
(self latching) Flush Mount. Non-Locking
(1) RF cabt drawer
(2)cabinet 0 drop down door
V0-14-2078 < > Latch, Southco M1, 21N S/S, (3/8" Door) Non-Locking, (1), CN 10-Rated at 10Ibs 8 WC
(self latching) Flush Mount. Non-Locking,
(2)GB cabt(2) K2(2)R1 (2)R2
SQUAD BENCH: 1 WC
V5-20-50SR X < > Squad Bench, Custom 1
(SAP# 10522452)New design for bench SR220147F
Recessed vertical style D cylinder storage to fit (2) Cylinder, Single, Zico QR-D-2
Strapless, NO waste
LID 170 INCH BOX: 1 WC
V5-64-0500 Lid, Squad Bench, Single 1 WC
HARDWARE: 1 WC
V5-80-1005 Handle, Trimark, Squad Bench, STD 1 WC
V5-82-2500 Strut, Gas, 60 LB, Installed, ILOS, Mods 1 WC
CURBSIDE SPLINT CABINET 160-170 inch Module 1 WC
VA-40-4530 < > CS Splint,7in Deep,2 Sect,Gray Lexan Flapglass, 170 Module 1 WC
Note: TO meet KKK requirement for space between
•
cushion on squad bench and bottom of splint cabt.
Gray Lexan Flap glass with Spring hinge
(4)2- M1 latches on each door
•
CURBSIDE REAR CABINET: 1 WC
VF-20-4700 < Cabinet,Curbside Rear,Standard,170",72"HR 1 WC
Eng note Dump switch is RELOCATED to RR entry door
CABINET H, BASEWALL 170", T1/T3 1 WC
VH-H2-SR00 XS < > H/M Combined Cabinet, Custom 1 WC
SR 220147F(SAP#
Combine H and M cabinets into a single cabinet, CN 10.
Single divider centered in cabinet with a shelf on each side of cabinet.
CABINET I, BASEWALL 170", T1/T3 1 WC
VH-12-0400 I, Cabinet, Deleted 1 WC
CABINET M, BASEWALL 160"& 170", T1/T9 1 WC
DELETED see H/M combined
VH-M2-0300 M, Cabinet, deleted 1 WC
CABINET 0, BASEWALL 160-170", T1/T3 1 WC
01/27/2020 18:26:45 Quote No: EI•in New 2020 R3-0001 Pa•e 18
PART NO S DESCRIPTION QTY ID
VH-OI-SR00 XS < > 0, Cabinet, Custom 1 WC
(SO-O-351178)SR220147F
Dimensions: 15"h x 21.75"w x 19.5"d Same as 229833
*Wood door hinged at bottom.
*Add(2)cables to hold door at approx. 30 degrees.
CABINET CPR, BASEWALL, 149"-170", T1 &T3 1 WC
VH-Q0-0101 CPR,side seat, Std Model only 1 WC
VH-Q0-0301 < CPR, side seat, flip up lid, Std Model only 1 WC
With Trimark Latch
VH-R1-0105 < "U" Barrier Bar, Padded, 6 7/8 x 7 1/2, 1.5 inch SS, CPR Seat, Gunmetal 1 WC
Mounted at the front of the CPR side seat vertically in line with the Padded head
cushion on the "L"cabinets.
CABINET J, STREETSIDE UPPER 170", T1/T3 1 WC
VI-J2-0150 > J, Cabinet, Combined with K 1 WC
VI-K2-0100 < K2, Cabinet,w/CPR seat 1 WC
Note: TO meet 43" minimum KKK requirement for space between cushion on S de
seat and bottom of splint cabinet. 3/8 gray flip up with 2 southco latches.
CABINET L, STREETSIDE UPPER 160-170", T1/T3 1 WC
VI-L1-0355 < L, Cabinet, L1, L2 Combine into 1 Large Cab, 72" H.R, Full F 1 WC
with adj shelf in "L2"
BASEWALL DOORS: 1 WC
VK-15-4020 < Cab H, Gray Polycarbonite Slider-CN 10 Compliant 1 WC
This is for H/M cabinet
TELEMETRY AREA WORK SURFACE 1 WC
VP-10-5461 Telemetry Tray, Poured, Gray 1 WC
ACTION AREA WORK SURFACE 1 WC
VP-10-SR02 X < 'Action Area Tray, Stainless Steel, ILOS 1
(SO-TRAY-351178)SR220147F
ACTION AREA 165/170 INCH BOX: 1 WC
VP-15-7005 < Cab,A/A,Without Biowaste, 170"Type 1 1 WC
Slide out tray ILOS, TRAY only, change from customer's last unit. Reference prey ous
unit 229833
VP-15-8500 S < > Writing Tray, Slideout,Under A/A Tray 1 WC
BOM option code 10535560.
Drop writing tray 3/4 of an inch below standard for inside height of 2.75" space to a low
1/4 alum plate for defib mount in rearward end of AA, thru bolted.
VU-14-4000 < > Shelf, Interior, Adj, in Cabinet: 4 WC
(2) H/M combined, 1 ea side of divider
(1)J
(1)L •
•
VU-14-4001 < > Shelf Track, Cabt, #HA24663, Upgrade, Std Model only 4 WC
("C"channel/exterior shelf style track)
VU-15-1820 Cab"J/K" Combined, Gray Polycarbonate Slider-CN 10 Compliant 1 WC
VU-15-7220 > Cab"L1,L2,L3"Combined, Grey Polycarbonate Slider-CN 10 Compliant 1 WC
01/27/2020 18:26:45 Quote No: El•in New 2020 R3-0001 Page 19
PART NO S DESCRIPTION QTY ID
VERTICAL DIVIDERS: 1 WC
VU-45-1000 < Divider, Vertical, Streetside Upper Cabinet 1 WC
Centered H/M cabinet !!
SHIP LOOSE ITEMS: 1 WC
YY-00-0001 > Bracket, Spare Tire Mounting, Ship Loose - 1 WC
YY-00-0004 X < Handheld Spotlight-Sho-Me 200,000 CP Ship loose 1
(Option code 10131387)Ship loose
YY-00-SR01 X < 5 qt Sharps disposal and mounting bracket 1
(SO-SL-351178)SR 220147F
Armstrong Medical 5 qt Sharps disposal & mounting bracket. Boundtree #2985078A
-5-quart transparent red sharps container񈸔 wall enclosure with lock .
•
YY-10-6400 Ship Loose, W.C. Standard Items 1 WC
FIRE EXTINGUISHERS: 1 WC
YY-13-2000 Fire Extinguisher. (1)5 LB. ABC, IATS, Ship Loose 1 WC
YY-13-3000 > Spare Tire, OEM only, Ship Loose 1 WC
WARRANTIES 1 WC
ZZ-10-0201 Warranty, Paint, 60 month Prorated, Standard 1 WC
ZZ-10-0300 Warranty, Structural, 15 Years, Std., Mods 1 WC
ZZ-10-0601 Warranty, Limited Electrical 1 WC
ZZ-10-0701 Warranty, Cabinet Construction 1 WC
ZZ-10-2200 > Warranty, Extended, 3 Year/36K Miles, Types 1, 3, 9 1 WC
ZZ-ZZ-0200 > End Of Order 1 WC
1 . CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
95 BACK UP CAMERA TAM85 TRAFFIC ADVISOR
TOMAR 700 LED LOAD LT. 700 LED LOAD LT.
COOL BARR R/C R R R/C R 900 RED LED LT. 900 RED LED LT.
(6)900 LED LTS. o o II n ___, 4,.
i Vg EA fel [ FM 1 1 -:...Fi :. :.:.: ,�r l
700 LED LT. 900 AMBER LED LT. 11 Or 900 AMBER LED LT.
900 BRAKE OVERRIED 14 ] 0 Oil 0 4,1,1 900 BRAKE OVERRIE
•
GO LIGHT Pei I 'oi A per • \:,.... A �( 1 •
,- -, ffn, 1 1 III.
., , ...
:I3: 11" �.33:1i WC TAIL
€ lij: 3=
TIRE RED LT. ___ I TIRE RED LT. I€ `' liii=�i:i1 1 LIGHTS
LIF •ii
0,, r v n . .. .,,...5...w..,:::::,, h'. . . . .. i
:..t„5,4,. :18
�, n r rM1
tr_____.
1!0, II.�I�J� I{ v �1 tti� ,r'<�7���Y_ v° .....a 5� in
y �
C ss _- :s :J1 ry.
® 0 4"LED RUNNING
� 1121
STEALTH BOARD LTS(2) 1111111111 11111111111
\.___i -AIR HORNS SWITCH SIREN
SIREN
SPEAKERS
EXTERIOR COMPARTMENT DIMENSIONS IN INCHES ed
Wheel
INTERIOR DIMENSIONS PASS THRU INTERIOR DIMENSIONS JAMB OPENING Coach
COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH
F450 4X4 TYPE 1 FORD 2019
FRONT/REAR
EXTERIOR VIEWS
DA fE: SCALC
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED 2/11/19
50"AISLE TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR 1-"WN'3Y AP -LW.,NO 1 /9
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
900 LED SCENE LT. 170 900 LED SCENE LT.
900 RED LED LT. 900 RED LED LT.
F I
QINDICATOR LT.
// �177 �n7 20A SUPER AUTO EJECT
•
/ — 1" 11 i 1AIRHO:NCOMP500 SERIES LT �11' 1 /{l L—_ 700 R/C LED
;_: �� it.
jE _�'_��-- D _ -
® - DEF FILLC II��EDSHELF ��Le „,„,„, !I-m I
411111
�,: ;u It . . b LSI b
�"Y DOGLEG FOR STAIR CHAIR
VO STAINLESS
ir
91 I
> RUNNING BOARD SPLASH GUARD
108 CA
193 WB
307 APPROX.OAL
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED
TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR.
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
EXTERIOR
INTERIOR DIMENSIONS AMBCOMPARTMENT DIMENSIONSIN
OPENING INTERIOR DIMENSIONS JAMB OPENING Wheeled
COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH Coach
• D 36.75 34.00 17.25 36.25 30.50 F450 4X4 TYPE 1 FORD 2019
E 36.25 39.25 17.00 36.25 37.00
F 82.50 28.25 17.25 81.75 27.25 LEFT EXT. VIEW
OATS DALE
2/11/19
50"AISLE
DRAWN 0V AP DwcNo 2/9
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
900 LED SCENE LT. m 900 LED SCENE LT.
900 RED LED LT.--..„...... 900 RED LED LT.
62
ADJ.SHELF
(10 el .
A T /®
500 SERIES LT
700 R/C LE� ® ® 1=�■
:,..:i_
61 _
al
Ch B - � -
0 ' (----1-7
• •••••
•
:;:;:i:i:i:i:i:;.:::::•:•:•:•:•:•.•:•.,:w.•:•.......-.•:...........:•.•::•:::::•:1 084%,
, . ;,0;., .
\ZICO STEP /15/OS TO E2 ONLY RUNNING BOARD
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED
TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
INTERIOR DIMENSIONS EXTERIOR AMBCOMPARTMENT DIMENSIONSIN
OPENING
INTERIOR DIMENSIONS JAMB OPENING Z Wheeled
COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH COMPT. HEIGHT WIDTH DEPTH HEIGHT WIDTH Coach
A 25.50 27.25 F450 4X4 TYPE 1 FORD 2019
-
B1 20.00 14.25 17.25 19.25 12.00
RIGHT EXT.VIEW
B2 82.50 19.00 18.50 81.75 17.00
LOWER-A 15.25 30.50 19.00 DATE
2/11/19 SCALE
. 50"AISLE DRAWN 6V AP DWG NO 3/9
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
COMBO HVAC 12V
•
wwwawawaaawaaoaaoa Y_1X Y �, 11oV
waawooawwawawwwwwaaawwwww
aaacoaaanwcawaaaaaw
ioaaa
IE—�I I��I i°Ooo ,
�oaaw �—ALUM.TRIM
So ;
�°°°a000000 oaoowooaa oowa°o°a°a°° �1.-.��-.--•- -•.-,•`._-•_.......
--`— ' — --ADJ.SHELF
m SPEED STRAPS
I ®a W/CLIPS
br---
I I� — . KNOX BOX MINI#5201
ENCOLSED ON THREE SIDES
I—__-_____ 72
E1 Y 8 jT DRAWER
ALUM.TRIM
--- SHELF
SPEED STRAPS
a 1 a W/CLIPS
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED
TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
CABINET WEIGHT RATINGS: INTERIOR CABINET DIMENSIONS IN INCHES
NON-RESTOCKING=40 LBS. CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Wheeled
RESTOCKING=30 LBS. Coach'
El 28.25 33.50 32.25
DRAWER 5.00 25.50 30.00 F450 4X4 TYPE 1 FORD 2019
E2 28.25 33.50 32.25 BULKHEAD INTERIOR •
DATE Si.ALE
2/11/19
50"AISLE DRAWN eYAP DWG NO 4/9
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
CM3000 DIGITAL THERMOSTAT
\ i Mr K2 17 \ r---- -1
• J `\ `� , L1 `\ N AC CAB. i USB
•
® - - CN10
BARRIER
N N CUSHION � N
\__ ---=•-- n ii.:: „ a
\\ 43 A Nv
_ L72
/i aMI1
• I 11� L TRAY
7
Io II oiQ I r o I t C t
L1 c No o i o IJ
III(JL
•J I 1 I IL l 1 I
—DROP DOWN DOOR
INTERIOR CABINET DIMENSIONS IN INCHES Z Wheeled
CABINET HEIGHT WIDTH _ DEPTH CABINET HEIGHT WIDTH DEPTH Coach
H 21.75 53.50 18.25
J 18.75 48.00 18.25 0 15.00 22.25 18.25 F450 4X4 TYPE 1 FORD 2019
K2 6.00 22.25 6.50 _
L1 18.75 41.00 16.00 • LEFT INTERIOR
""" 2/11/19 "A"
CABINET WEIGHT RATINGS:
50"AISLE NON-RESTOCKING=40 LBS. BE ADVISED THAT THESE ARE,PRELIMINARY LAYOUTS INTENDED ONN" AP °"A"° 5/9
RESTOCKING=30 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
•
•
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
NON STANDARD CABINET
• REQUIRED FOR SEATED
HEADROOM. r 3/8"FLIP UP LEXAN (2)
7 'I i! 17 1
— – 1
AC CAB.- '
1.
O 002
•\
DBL TINT A A A A 43
° 72
J
\\' N V w I I I
I w g I I I I
7 (////4„
'>•- ,—, ,:o.", / ( 1.14,11, ILLEA , ,11+, _)_/;) .
L2�1 II 01 1 0 I id 111311 1101 1 0 !
Jr ----�
--._. f1 I I ° I •
L
ry I I II
I
] .
(2)"D"CYLINDERS11E9 LL II e TIR 6 LIGHT
•
72
INTERIOR CABINET DIMENSIONS IN INCHES Wheeled
Coach
COMPT. HEIGHT WIDTH •DEPTH COMPT. HEIGHT WIDTH DEPTH •
R1 5.00 30.25 7.00 F450 4X4 TYPE 1 FORD 2019
R2 5.00 30.25 7.00 RIGHT INTERIOR
0 15.00 22.25 18.25
WiE 2/11/19 SGLE
50"AISLE CABINET WEIGHT RATINGS: BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED WF° AP 6/9
NON-RESTOCKING=40 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
RESTOCKING=30 LBS. • REFERENCE ONLY PRIOR TO FINAL ENGINEERING
CA164684 • CITY OF ELGIN FIRE DEPT. 170x95x72
•
CLOG
01
CN 10 ,-
BARRIER
CUSHION
1i
72
E n n 3
1M-V/
}-17117
(2)"D"CYLINDERS
COI QV
. I I ~
J I.I
INTERIOR CABINET DIMENSIONS IN INCHES Wheeled
Coach
COMPT. HEIGHT WIDTH DEPTH COMPT. HEIGHT WIDTH DEPTH
F450 4X4 TYPE 1 FORD 2019
•
REAR BULKHEAD INTERIOR
DATE 2/11/19
SLE
50"AISLE CABINET WEIGHT RATINGS: BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED '""" AP 7/9
NON-RESTOCKING=40 LBS. TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
RESTOCKING=30 LBS. REFERENCE ONLY PRIOR TO FINAL ENGINEERING
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
GLOVE BOX I R1, III R2 I
STEP WELL ) II t II
I ll I II
SQUAD BENCH ICOMPT.B1L COMPT.B2
E CABINET ' L--- .
rff
el
STRYKER-POWER LOA= — 50
1- Io ro I3LI-1 I a �, ,
o
= a SEAT TRAVEL s
W I FROM CENTER „e ��
POSITION
I
II
� .°T) f i
SAME AS351177
I� Li CABINET 1 r J CABINET
ACTION AREA I CPR SEAT 1 I
COMPT.F I I H CABINET I
I
I COMPT.F K2 CABINET COMPT.D /
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED
TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
REFERENCE ONLY PRIOR TO FINAL ENGINEERING •
INTERIOR CABINET DIMENSIONS IN INCHES Wheeled
CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Coach'
F450 4X4 TYPE 1 FORD 2019
FLOOR PLAN
DATE: SCALE
2/11/19
50"AISLE OWN aY AP DVA"0 8/9
CA164684 CITY OF ELGIN FIRE DEPT. 170 x 95 x 72
—(10)LED DOME LTS.
in 1 N
I
►U r—Ti�� II °I t I I
(-7 1
,;. '''
•
o' o' o GRAB RAIL
COAX 1 1 °J °J COAX 3 °J COAX 5
E ,, 9.) . •-• N.--.- ,-_..,
COAX 2 i WIRE TROUGH COAX 4
r---I X01 401 X01 4.01
L_• 7 r i it — ——+
II •I I 1
II I I I
II I ' I I
II— - I I
BE ADVISED THAT THESE ARE PRELIMINARY LAYOUTS INTENDED
TO ILLUSTRATE DESIGN INTENT AND DIMENSIONS ARE FOR
REFERENCE ONLY PRIOR TO FINAL ENGINEERING
INTERIOR CABINET DIMENSIONS IN INCHES Wheeled
CABINET HEIGHT WIDTH DEPTH CABINET HEIGHT WIDTH DEPTH Coach
•
F450 4X4 TYPE 1 FORD 2019
LINER
D' SCALE
2/11/19
50"AISLE D""HY AP DWG NO 9/9
ATTACHMENT C
'1. 111t?
SALES CONTRACT
This agreement made by and between FIRE SERVICE, INC (Company) and
City of Elgin, IL
(Legal Name of Buyer)
150 Dexter Ct Elgin IL 60120
(Address) (City) (State/ Province) (Zip/Postal Code)
1. ACCEPTANCE: The "Company" agrees to sell and the "Buyer" agrees to purchase the
ambulance and equipment described in the Wheeled Coach specifications and made part of this
contract, in accordance with the terms and conditions listed on contract pages 1. 2, and 3., and in
agreement and utilizing the tag on clause within the contract between the City of Elgin, IL and Fire
Service, Inc which was fully executed on June 10, 2015.
2. DELIVERY: The ambulance shall be ready for delivery within approximately 90 - 120
calendar days, after the receipt and signed acceptance of this contract, confirmed build order and
chassis at the REV Group Orlando Corporate Headquarters, Winter Park, FL. The Company cannot
be held liable for penalties and/or delays due to strikes, failures to obtain materials, fires, accidents,
force majeure, or any other causes beyond the Company's control.
In order to establish a stable design, procurement, and build schedule, a Buyer change order cutoff •
date of eight (8) Days from the date of the execution of the contract will be enforced. Changes in
•
major components, configuration, or other items that may change the major components or
configuration,(e.g.: Chassis, Motor,Transmission,Wheel Base)will not be allowed after the contract
execution date.
If inability to obtain exclusive or brand name materials causes completion or delivery problems, the
Company shall advise the Buyer of said problem. The Company resolves to examine alternative
sources of said material. Material substitutions shall be mutually agreed upon by the Buyer and the
Company. No substitutions shall be made without the execution of a written change order by the
Buyer.
3. CHANGE ORDERS: Changes to the contract may be requested by the Buyer after the
execution of the contract according to Section 2 of this document. Changes shall be reviewed for cost
and schedule impact by the Company. Changes shall be sequentially numbered. Change Orders shall
be prepared by the Company and executed by the Buyer. The price of the apparatus shall be adjusted
to take into account any Change Orders. Any and all Change Orders may extend the completion
and delivery of the ambulance.
FSI Sales Contract, Page 1 of 3 Original (03-10-2006)
Sales Policy Manual Attachment F
•
4. SPECIFICATIONS: The Company agrees that all material and workmanship in and about
this apparatus shall comply with the original Wheeled Coach proposal dated.February 16,2018.
(1) Wheeled Coach 2018 F450 Chassis Type I Custom Ambulance per City of Elgin Specifications.
5. WARRANTY: Shall be as proposed in the attached Wheeled Coach specifications.
6. PRICE: The Buyer shall pay, as a purchase price for the ambulance(s), the sum of Two
Hundred Fifty-Thousand,Three Hundred Sixty-Two and 00/100 dollars or(L 250,362.00).
All prices are less any applicable local, state, or federal taxes which may be applied to the apparatus
proposed.
NOTE: Payment shall be made only to:
Fire Service,Inc.
9545 North Industrial Drive
Saint John, Indiana 46373
7. TERMS OF PAYMENT:
F.O.B. St. John, IN. Zero down payment, full payment at delivery via wire transfer or
municipal check.
The purchase price payment reflects US dollars and does not include any authorized change
orders which, if applicable, shall be paid at time of final inspection and signed acceptance.
b) No payment of any amount shall be made payable to a sales representative without
written approval from the company.
c) It is agreed that the ambulance and equipment covered by this contract shall remain
the property of the Company and not be placed in service until the entire contract price has
been paid.
d) A copy of the Buyer's tax-exempt certificate, if applicable, shall be submitted with
this signed contract.
8. FIRE SERVICE, INC requires,and the Customer agrees, that the unit shall be inspected and
/or delivered within seven(7)days of notice that the unit had been completed.
9. CANCELLATION: This contract is subject to cancellation by Buyer only upon payment to
Company of reasonable cancellation charges,which shall take into account expenses already incurred
and commitments made by Company.
FSI Sales Contract, Page 2 of 3 Original(03-10-2006)
Sales Policy Manual Attachment F
•
This contract,to be binding,must be signed by an officer of Fire Service,Inc or a person authorized,
in writing,by Fire Service, Inc. to do so.
10. TAG-ON /ADDITIONAL ORDERS: At its sole discretion, the COMPANY may allow the
terms of this contract to be extended to both the BUYER and similar agencies for the purchase of a
similar unit(s)under similar terms for a period of three(3)years from the date of the execution of this
contract. Should the COMPANY choose to exercise this option, it shall be permitted to adjust the
contract pricing to account for equitable price adjustments associated with the change in the cost of
the materials used to produce the unit. Such adjustments will be based upon the Producer Price Index
(PPI) for fire trucks and I or heavy transportation equipment or by itemizing price changes expected
by the company from the component vendors. If there are any changes between the unit(s)purchased
via this contract and any subsequent orders, those changes must be documented via properly signed
and executed change orders, including any necessary price adjustments. If the purchasing agency is
not the BUYER, a separate contract will be required to complete the additional purchases.
This contract,including its appendices,embodies the entire understanding between the parties relating
to the subject matter contained herein and merges all prior discussions and agreements between them.
No agent or representative of the Company has authority to make any representations, statements,
warranties, or agreements not herein expressed and all modifications of amendments of this
agreement, including any appendices, must be in writing signed by an authorized representative of
each of the parties hereto.
No surety of any performance bond given by the Company to the Buyer in connection with this •
Agreement shall be liable for any obligation of the Company arising under the Standard Warranty.
•
•
IN WITNESS WHEREOF, the Buyer and the Company have caused this contract to be executed by
their duly authorized representatives this 7th day of March, 2018. •
COMPANY BUYER
Fire Service, Inc. City of Elgin, Illinois
9545 North Industrial Drive 150 Dexter Court
Saint John, Indiana 46373 Elgin, Hlinois 60120
219-365-7157 Phone 847-931-5660 Phone
219-365-8572 Fax 847-931-6027 Fax
BY J4 Lege4. B �
NAME: Jeff LeBeda NAME: .�`�+` /1
TITLE: Vice President of Sales TITLE:
DATE: March 7.2018 DATE:March7. 2018
FSI Sales Contract, Page 3 of 3 Original(03-10-2006)