HomeMy WebLinkAbout14-1228 Fire Service taas
.ram
• .SALES CONTRACT
This agreement:Made by and between FIRE SERVICE, INC (Company) and
City of Elgin; IL
(Legal Name of Buyer)
•
150_Dexter Ct. Elgin IL 60120
(Address) (City) (State[Province) (Zip/Postal Code)
•
• 1.. ACCEPTANCE: The "Company" agrees to sell and the "Buyer" agrees to purchase the
ambulance and equipment described in the Wheeled Coach specifications and made part of this
contract, in accordance with the terms and conditions listed on contract pages 1, 2, and 3.
2. DELIVERY: The,ambulance(s) shall be ready for delivery approximately 90-120 days,
after the:receipt of ordered chassis upon signed acceptance of this contract at the Wheeled Coach
Corporate;Headquarters, Winter,Park, FL. The Company cannot be held liable for penalties and /or
-delays due_tostrikes, failures-to obtain materials, fires, accidents; force ma_jeure, or any other causes
beyond the Company's control.
•
In order-to establish a stable design, procurement, and build schedule, a Buyer change order cutoff
date Of eight() Days from the date of the execution of the contract will be enforced. Changes in
• major components,_ confi'guration,, or other items that may change the major components or
configuration, (e.g.: Chassis, Motor, Transmission, Wheel Base) will not be allowed after the
• contract execution date:
If inability to,obtain exclusive or brand name materials causes completion or delivery problems, the
Company shall .advise the Buyer of said problem. The Company resolves to-examine alternative
sources of said_material._Mater"ial-substitutions shall be mutually agreed upon by the Buyer and the
Company. No substitutions shall be made without the execution of a written change order by. the
Buyer.
3. CHANGE ORDERS: Changes to the contract may be requested by the Buyer after the
execution.of the contract 'according.to-Section 2 of this document. Changes shall be reviewed for
cost and schedule impact by the;Company. Changes shall be-sequentially numbered. Change Orders
shall be prepared by the.Company and executed by the Buyer. The price of the apparatus shall be
adjusted to take into account any Change Orders. Any and all Change Orders may extend the
completion and delivery of-the ambulance.
FSI Sales_Contract,Page 1 of 3 Original(03-10-2006)
Sales Policy Manual Attachment F
PDF created:witn pdfFactory trial version www.pdffactory.com
H
4: SPECIFICATIONS:.The Company agrees that all material 'and workmanship in and about
this.apparatus shall.comply with the hereto attached Wheeled Coach proposal dated December 8,
2014.
(2)2015 Ford.F450 4x4-Wheeled Coach Type l Ambulances Duplicating 31121 1-4 with changes.
5. WARRANTY: Shall be as proposed in the attached Wheeled Coach specifications.
6.. -PRICE: The Buyer shall .pay, as a purchase price for the ambulance(s), the sum of Four
Hundred Thirty One Thousand Four Hundred and 00/100 dollars or 5 431,400.00, , Fire Service
Inc:_will take in trade-the:following;
(2) 2008 Ford:41450 Wheeled Coach Type'1. ambulances. including Stryker Power Pro Cots,
and-one:additional Strvker-Power-Pro COt, fo"r a trade value.of:S27,500.00 total.
Net contract price.due.at delivery.with-trades is $403, 900.00.
All prices are less---any applicable local, state, or federal taxes which may be applied to the apparatus
proposed:.
NOTE: Payment shall be made only to:
Fire Service,Inc.
95-45 North Industrial Drive
Saint John, Indiana 46373
7. TERMS OF PAYMENT: .
F.O.B. St..John, IN. Zero down payment, full payment at delivery via wire transfer or
bank check. •
The purchase.price payment.reflects US dollars and does not include any authorized change
orders which, if applicable, shall be paid'at time of final inspection and signed acceptance..
b) No payment=of any amount shall be made payable to a sales representative without
written approval from the company.
c) It is agreed that the ambulance and equipment covered by this contract shall remain
the property of the Company and not be placed in service until the entire contract price has
been paid.
d)_ A copy of the Buyer's tax-exempt certificate, if applicable, shall be submitted with
this.signed contract.
8. FIRE-SERVICE; INC..requires, and the Customer.agrees, that the unit shall be inspected
and/or delivered within seven (7) days of notice that the unit had been completed.
9. CANCELLATION: This contract is subject to cancellation by Buyer only upon payment to
Company of ,reasonable cancellation. charges, which shall take into account expenses already
incurred and commitments made by Company.
FSI'Sales Contract: Page 2 of 3 Original (03-10-2006)
Sales Policy Manual Attachment F
PDF created with pdfFactory trial version www.pdffactory.com •
•
This contract, to be binding, must be signed.•by an officer of Fire Service, Inc or a person
• authorised, in writing,..by Fire Service,Inc. to do so.
10. TAG=ON [-ADDITIONAL ORDERS: At its sole discretion,.the COMPANY may allow
the terms of"this contract to be extended to both the BUYER and.similar agencies for the purchase
of a similar unit(s) under-similar terms for a period,of one.(1)year from the date of the execution of
this contract. Should the COMPANY choose to exercise this option, it shall be permitted to adjust
the contract pricing to account.for equitable price adjustments associated with the change in the cost
of the materials used to produce the unit. Such adjustments will be based upon the Producer Price
Index (PP))for:fire,trucks.and / or heavy transportation equipment or by itemizing price changes
expected`by-the company.from_the component vendors. If there ate any changes between the unit(s)
purchased via this contract and .any subsequent orders, those changes must be. documented via
properly .signed and; executed change orders, 'including any necessary price adjustments. If the
'purchasing_ agency is not the BUYER, a separate contract will be required to complete the
additional purchases.
•
This contract, .including its appendices,. embodies the entire understanding between the parties
relating to the-subje4 matter contained herein and merges all prior ;discussions and agreements
between them. No. agent -or representative of :the Company has authority -to make 'any
representations, statements, warranties, or agreements.not herein expressed and all modifications of
amendments. of this agreement; including any appendices; must be in writing signed by an
authorized.representative of:each ofthe parties hereto.
No surety of any performance bond given by the Company to the Buyer in connection with this
Agreement shall be liable for any obligation of the Company arising under the Standard Warranty.
IN WITNESS WHEREOF, the Buyer and the Company have caused this contract to be executed by
their duly authorized representatives this 2'8th day of December, 2014.
COMPANY • BUYER
FireService,Ine. City of Elgin,IL
9545 North Industrial.Drive 150 Dexter Ct.
Saint John,Indiana46373 Elgin, IL.60120
219-365-7157 `Phone
219-365=8572. Fax
BY: lily BY: Z3P
NAME: Jeff LeBeda NAME: FA,j /:• 51 E&A LL.
TITLE: Agent TITLE: C.,i-F y MR E/2
DATE: December28. 2014 DATE: /2 /7 ��
•
FSI=SaIes-Contract, Page 3 of 3 Original.(03-10-2006) •
Sales Policy Manual Attachment F
PDF created with pdfFactory trial version www.pdffactory.com
ihAVA..-x2,4s 4h5-.-
U ea rnv r-Ti-
Barbara Furman
From: John P. Fahy
Sent: Monday, December 22, 2014 8:09 AM
To: Barbara Furman; Maria Medrano
Cc: William Cogley; Kim Dewis
Subject: 2015 Ambulance purchase
0
Attachments: Elgin Build WO 120814.pdf
Barbara,
Attached is the build order for the two ambulances that were approved as part of the contract with Fire Service Inc.
Chief Fahy
From: Barbara Furman
Sent: Friday, December 19, 2014 10:16 AM
To: Maria Medrano
Cc: John P. Fahy; William Cogley; Kim Dewis
Subject: FW: Scanned Contract
Maria,
Kim Dewis forwarded your 12/18/14 email to me regarding the Fire Service, Inc. Sales Contract.
Please forward to me the 3 pages of specifications referred to in Paragraph 1 of said sales contract. Thank you!
bf
Barbara E. Furman
Legal Secretary/Paralegal
150 Dexter Court
Elgin, IL 60120
Telephone: 847/931-5656
Facsimile: 847/931-5665
E-Mail: furman b a,cityofelgin.org
From: Kim Dewis
Sent: Thursday, December 18, 2014 11:20 AM
To: Barbara Furman
Subject: FW: Scanned Contract
Have you see this or do you need a copy of it?
From: Maria Medrano
Sent: Thursday, December 18, 2014 11:15 AM
To: Kim Dewis
1
Cc: John P. Fahy
Subject: Scanned Contract
Maria J. Medrano
Fire Clerk Typist
847-931-6620
Medrano m@cityofelgin.org
2
Wheeled
:_- oach°OUT IN FRONT QUOTATION
Elgin Fire Department Fire Service, Inc.
John Fahy Jeff LeBeda
150 Dexter SHA
Elgin, IL 46373
2015 Elgin FD 15-1
Exp. Date: 11/27/2014
Quote No: Order-0008 •
Job/Order No: ELGN15
T1 - 170: 210160 STD Model: Type 1 Ford - 170"Module-#1170F
T1 - 170: 0990029STL Ford, F-450,189"WB,4x2, XLT,170", #1170F
T1 -170: 200011 STD Type 1 Ford - 170" Module-#1170F
11/02/2014 16:14:07 Page 1
.S QTY ID DESCRIPTION
1 WC CHASSIS:
S > < 1 WC Ford, 2015 F-450, 4x4, XLT, 6.7L, 170", #1170F 2015-1
SHOP NOTE:
189"wheelbase
Autothrottle OEM Ford
Alternator OEM Ford •
Mirrors, OEM, Heated/Remote
Cab seats OEM Captains chairs(no armrests) .
Includes.Link Air Suspension System
ENG. NOTE:
SPECIAL ORDER CHASSIS SHEET MUST BE SENT.IN
1 WC CAB TO MODULE MOUNTING:
> < 1 WC Bellows, Passthru, Unigrip, F1 2008+, Std
SHOP NOTE:
• With Alum cab insert. Note DELETE lexan slider at pass thru. •
ENG. NOTE:
With Aluminum cab insert.
1 WC CHASSIS ADD-ONS:
> < 1 WC Lettering, By Outside Vendor
SHOP NOTE: •
Unit gets a rear chevron
Location: 24/7
#'of Days:'2 days_. ,- , • .. .
ENG. NOTE: -
State where Lettering is to be done:
Days needed for Lettering_ • ' - .
1 WC ' SUSPENSION:
> 1 WC Air Suspension, Links Air Ryde, Dyna, F450/F550, Elect
SHOP NOTE: ' ' ' .
PDF created with pdfFactory trial version www.pdffactory.com
•
11/02/2014 16:14:07 Pa•e 2
S QTY ID • DESCRIPTION
ENG. NOTE:
(no charge option only on #1153F ҒF) !!
Active suspension. Choose switching option required.
> < 1 WC Auto Dump w/override Sw, For Air Suspension
SHOP NOTE:
dump feature to be activated by left rear entry door.
_Override switch to be recessed in CSR cabt, near right rear
entry door. Wired CONSTANT hot ILOS.
ENG. NOTE:
•
SWITCH,RECESSED IN CURBSIDE WALL CABINET INSIDE REAR ENTRY DOORS
1 WC • CHASSIS ADD ONS, MISC
< 1 WC Ignition Security System, Kussmaul, #091-160 (Not Dodge)
SHOP NOTE:
With switch located on driver's side dash to the right of the steering column.
1 WC Cab Flooring, Black Rubber,2009+, F350/450, OEM
1 WC HEATING/AIR CONDITIONING:
X < 1 • Splash/Cover over Elec Heater valves ILOS
SHOP NOTE:
• (SO-CVR-311215) Install per Jose H.
A cover made out of aluminum to protect elec heater valve under compt A area.
1 WC Hoses, Heater, No Max, to Rear, STD
ENG. NOTE:
(used to be#1050015, for reference)
Hoses area included in heat/ac option code.
S > < 1 WC Heat/AC, F1, 2011+, Combo,w/Coolbar
SHOP NOTE:`
(SO-AC-311214)
Relocate Combo H/AC:Centered oVer bulkhead. Locate Electrical in bulkhead cabinet per Eng.
' with thermostat in action area: •
12vdc External Condenser, in Coolbar mounted on front
of module. Painted Red Sikkens: FRE 3015
ENG. NOTE:
Must allow space on front of module for Coolbar !!
Must pick warning lights separately !!!
(condenser must be removed to remove chassis for engine repair. This is not covered by WC
warranty)
1 WC BATTERY SWITCHES:
S > < 1 WC Battery,Sw,5 Min Timer F1, Fig 5B, (2)OEM Batt, (1) in RF ILOS
SHOP NOTE:
(SO-BAIT-311214) Timer ILOS-set-up per Elec Eng for check out lights only. Batt sw will be ign
only !
(2) Batteries under hood.
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:07 Pa•e 3
S QTY ID DESCRIPTION
(1) Delco 1150 in RF batt compt on a tray IATS, note see battery charger also.
ENG.-NOTE:
(must select"split" RF compt"A" !!)
1 WC BATTERIES:
< 1 WC Battery, Delco, 1150, (1) Each
SHOP NOTE:
RF compartment
< 1 WC . CONSOLES:
SHOP NOTE:
See Center console layout reference.pdf on the server in the work order folder.
< 1 WC Console, Center,-Pass-thru,'Mica Finish, F1, 2008+
SHOP NOTE:
See added map pocket IATS
1 WC Console, A/A, Wood, Angled
1 WC ADDITIONAL CONSOLE IN CAB: •
1 WC Console, Map Pocket,Bolt on,at Rear,F1
BULKHEAD CABINET:
X > < 1 Bulkhead, Custom
SHOP NOTE: -
SR 214923F
(SO-BH-311045)Per Eng design.AC unit over pass through.
Pass through. -Note DELETE lexan slider at pass through
(1) Bi fold D oor for CB access to the driver's side of pass
through. •
(1) Bi fold Door for CB access, under pass through
ENG. NOTE:
DSM- Remember to check the"S" Box
< 1 WC - WHEELCOVERS:
SHOP NOTE:
Paint OEM rims (4) outer wheels and SPARE tire. paint code Red #FRE 3015 (No wheel
- covers). ._ , •
X < 1 • Phoenix Air-Max AML1 valve'extenders.ILOS.
SHOP NOTE:
(SO-VS-311214)SR213095F
Air Valve Ext only'valve extenders, rear duals no wheel covers.
1. WC V
1 WC Type 1 - 170" Module-Standard Model Series
1 WC Type 1 - 170" Module .General Body Construction Spec .
1 WC Type 1 - 170" Module Vehicle Body Structure Spec
1 WC INTERIOR_ CABINETS ETS-Duralite Construction, Wood . V
< 1 WC MODULE BODIES:
SHOP NOTE:..
All compt floors are sweep out.
•
PDF created with pdfFactory trial version www.pdffactory.com
•
•
11/02/2014 16:14:07 Pa•e 4
S QTY ID - DESCRIPTION.
NO drop.skirt,! _
< 1 WC Aisle Space, 50 inches, STD, Type 1, Std Model Only
• SHOP NOTE:
(49-50"actual)
Requires stainless steel wheel well covers attached
to squad bench and-base-wall cabts that will
protrude approx 1.5" into aisle way on each side.
Install anti-slip decal with Wheeled Coach logo
on curbside and rear stainless steel thresholds
1 WC Module Skins, 0.125 inch
SHOP NOTE:
•
1 WC Headroom, 72 in. Type 1 - 170" module, #1170F/D
< 6 WC Coating, Scorpion X02, Per Compt, (1), Std
SHOP NOTE:
light gray . •
- 1 WC Coating, Scorpion, Rear Bumper Supports
> < 6 WC Compartments, Sweepout
. • SHOP NOTE: . • - .
All Compartments. _ _ _
ENG:-NOTE:, .
compt"A"_&"F"are std sweep out
< 1 WC ,Duraseam_Doorswith Hidde_n Jambs
SHOP NOTE:
- Magnetic door switches, Standard
XS > < 1 WC . A, Compt, Custom Split, Hoseline, 170" Module
SHOP NOTE:
SR 214923F. .
(SO-A-311045)Split Compt Same as 321111
Upper compt, with inside/outside access to El & E3.
•
Lower compt for(2)battery tray.
Relocate Hose line HVAC unit over the pass through.
ENG. NOTE:
• DSM-Remember to check the"S" box.
. 1 WC . B1, Compt, Std;.170" Module, 72" HR, #1170F/D
• 1 WC B2, Compt, Std, 170" Module, 72"H.R, #1170F/D
< . 1 WC. D, Compt, Mid.Height, 170"Module, 72" H.R, #1170F/D
SHOP NOTE:
Single door
PDF created with pdfFactory trial version www.pdffactory.com
•
11/02/2014 16:14:07 Pa•e 5
S S . QTY ID DESCRIPTION......-
< 1 WC E, Compt, Std, 170" Module, #1170F/D
SHOP NOTE: . •
With Double Doors Eng note see AA drawer
S <. 1 WC F, Compt, Std, Full Height, 170" Module, 72" H.R, #1170F/D
SHOP NOTE:
(SO-F-311045) Per Eng design .
With Dogleg for Stairchair in Compt"F" (9.5"wide) •
DOG LEG FOR STAIR CHAIR. Door to open past 90 degrees. •
> < 1 WC With Dogleg for Stairchair in Compt"F"
SHOP NOTE:
DOG LEG FOR Stryker 6252 Chair. Door to open past 90 degrees.
. ENG. NOTE:'
(not available when electric 02 rack is selected)
1 WC FUEL FILL HOUSING:
• 1 WC Housing, Fuel Fill, Cast, F1/C1/D1/M2 . .
ENG. NOTE:
Ford and Chevrolet both require 2 housings.
1 WC EXTERIOR DIVIDERS:
< 1 WC Divider, Vertical, B2, 3/16"Thick, Recessed Adj Track,Std Model only
SHOP NOTE:
(divider to be full depth) compt"B2", centered.
< 1 WC Divider, Vertical, (1), LF, Full Height •
SHOP NOTE:
• Full Depth Compt F mounted at edge of dogleg. •
1/2 height divider, mounted wall 2 &ceiling. •
Customer,requires lower area of compt to be clear for stair chair storage.
1 WC ' - SHELF- COMPARTMENT"A"/RF CABINET:
> < 1 WC Shelf, Adjustable,(1), RF Cabt Custom
SHOP NOTE: .• .
RF•Compt"A"/cabt"E3" area
ENG. NOTE:
w/aluminum shelf track, std.
> < 1 WC Shelf, A dditional, Adjustable, (1), RF Cab Custom
SHOP NOTE:
RF Compt"A"/cabt"E3"area •
•
ENG. NOTE:.
w/aluminum shelf track, std.
1 WC SHELF- COMPARTMENT"B"/"B1":
> < 1 WC Shelf, Custom, Adj, Cmpt"B", (1) -
SHOP NOTE:
Located from_divider to wall 3 shelf to be approx 44" up from the floor of the compt.. .
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:07 Pa_.e 6
S. QTY ID _ - DESCRIPTION
ENG. NOTE: _
w/aluminum shelf track, std.- •
1 WC •SHELF- COMPARTMENT"D": -
> 1 WC Shelf, Custom, Adj, Cmpt"D", (1), Std Model only
ENG: NOTE:.
w/aluminum shelf track, std.
1 WC SHELF- COMPARTMENT"E":
1 WC Shelf,Fixed, Cmpt E, forlElectrical storage, No Divider
1 WC SHELF- COMPARTMENT"F":
> < 1 WC • Shelf, Custom, Adj, Cmpt"F", (1)
SHOP NOTE:
Wall 1 to divider
ENG. NOTE:
w/aluminum shelf track, std.
> < 1 WC Shelf, Custom, Adj, Cmpt"F", (1), Additional
SHOP NOTE: -..
Wall 3 to divider above 02 height
•
•
ENG. NOTE:-
w/aluminum shelf-track, std..._
1 WC - COMPARTMENT/SHELF, MISC:
> < 1 WC Reinforcement,Door,SCBA Bracket
SHOP NOTE:
"Reinforce Compt. D and E, entire wall#2, for SCBA mounting. •
ENG.-NOTE:
per door
1 WC WINDOWS:
1 WC Window;Upper,CS/SIdr,Rear/Slide,Privacy,PAN
1 WC MODULE ENTRY DOOR HANDLES:
1 WC Handles, Patient Entry, Trimark Black/Chrome"SafePass" STD
1 WC EXTERIOR COMPT DOOR HANDLES:
> 7 WC Handle, Module Compt, Trimark, Black/Chrome, STD
ENG. NOTE:
•
Number of door handles selected in total must equal
number of exterior compartment doors.
> < 1 WC Latch,.Paddle,Trimark, For Trailing Door • , .
SHOP NOTE:
• - compt„E,
ENG. NOTE:
Number of door latches selected in total must equal
number of exterior compartments w/double doors.
1 WC ELECTRIC DOOR LOCK PACKAGE OPTIONS: Click to add
ENG. NOTE: -
Pick all required options by highlighting this code and hitting "insert"
Specify which doors and location(s)of switch(es)
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:07 Pa.e 7
S QTY ID DESCRIPTION _ .
> < 2 WC Door Locks,Electric, Trimark, (1)DOOR, Entry Door
SHOP NOTE:, _ , - "..
Module entry doors.
ENG. NOTE: .
This is per DOOR price)))))))))))) Adjust quantity IIlIII
All installed electric lock systems will be wired constant hot unless otherwise specified. State
location of electric locks in shop notes.
> < 6 WC Door Locks,Electric, Trimark, (1)DOOR, Compt Door
SHOP NOTE:: • • s •
All module compts(except battery compt)
ENG. NOTE:
This is per DOOR price)))))))))))) Adjust quantity IIIIII
All installed electric lock systems will be wired constant hot unless otherwise specified. State
location of electric locks in shop notes.
> < • 1 WC Switch,Momentary•Rocker;Activate Elect Door Locks -
SHOP NOTE:
Installed on C/S wall at head of S/B.
ENG: NOTE:'.
State installation location in shop notes.
> < 1 WC Switch, Stealth, Cab/Mod Doors (not Dodge)
SHOP NOTE:
In grille area on passenger's side.
ENG. NOTE:
To unlock module and.cab doors:State location of switch in shop notes. .
• 1 WC Relay Control Circuit, Electric Locks •
ENG. NOTE:
•
Will activate up to 8 door locks.
1 WC - Circuit, OEM Door Lock to activate Mod Doors(not Dodge)
1 WC DOOR HOLD OPENS:
> < 1 WC Hold Opens,Rr Doors,Cast,Grabber(2), 5.5", Std Model only
SHOP NOTE:
Installed so doOrs will open as wide as possible
Mount at BOTTOM of doors.
ENG. NOTE:
State installation location in.shop notes.
X < 5 " Hold Open,Gas Strut, 110 Degree, Custom, ILOS ,
SHOP NOTE:
SR 214923F .
(SO-HOLD-299107)
(1) For compartment"F"
(2)Compt E .
(1) Compt D
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:07 • Page 8
S QTY ID DESCRIPTION
(1) Compt(B2)
< 1 WC Hold Open, Gas Strut, Ext Compt, 301b, Std
SHOP NOTE:
B1, •
1 WC . Hold Open, Gas Strut, RF Compt,.301b, Std
1 WC DOOR PANELS:
X < 1 Panels, Entry,.Durasafe, Stainless Steel, w/Chevrons, ILOS •
SHOP NOTE:
(SO-PANEL-291100) Durasafe Design Ref Dallas :'
•
Alum center_panels will be covered with diamond grade green-yellow/red 4" chevron striping by
24/7, 45 degree angle to match rear of module.
1 WC FENDER FLARES:
1 WC Flare;Fender, Rear, Black Rubber, Std Model only `
1 WC BUMPERS:
X < 1 Bumper,Rear,w_/.Skids & Flip Up,F1,w/LED DOT Lts, 12" ILOS
SHOP NOTE:
• (SO-BMPR-311045)SR#214923F PER ENG DESIGN
12 INCH DEEP BUMPER ILOS •
w/Gator Grip on.flip up step. 1 - •
1 WC • - . - RUNNING BOARDS: '
< 1 WC Running Boards, Standard,F450, w/Gator Grip, #1153F/1170F
SHOP NOTE: .
Reinforced at rear
* note LED light in stone guards.* •
1 WC • , SKIRTRAILS •
1 WC Skirtrails,Extruded Rubber w/Refl Tape,170-175" Module
1 WC Tape, R eflective, R ed,For Extruded Rubber Skirtrails
•
1 WC STONE GUARDS(FRONT):
1 WC • r. Corn er Post.Gua_rd, F_ull,Height,-(4)
1 WC KICKPLATES (w/STD. REAR STONEGUARDS):
1 WC Kickplate,'W/Recess, No Light Holes,Duraseam
1 WC RECOVERY DEVICES
• 1 WC, Tow,Eyes,_Black,-in Rear Kickplate
ENG. NOTE:
(will-not fit on-##3165C) !!!. .
1 WC MODULE ADD-ONS:
X < 1 Splash Plate,Urea Tank Fill,Stainless Steel,'011+ "F"-Series IATS
SHOP NOTE:
(SO-SPLSH-321117)Same as ZZ-20-1A59
•
X < 1 Splash Plate, Fuel Fill, Stainless Steel, IATS
SHOP NOTE:' . • .
(SO-FUEL-321117)Same as ZZ-20-1A60
•
< 1 WC Holder, License Plate, Cast, C 30002, STD
- SHOP NOTE:
-in rear kick plate, centered
•
•
•
1 WC SILL PROTECTORS •
1 WC • Sill Protectors; Stainless, Ail Compts, Std Model only . •
PDF created with pdfFactory trial version www.pdffactorv.com
11/02/2014 16:14:07 Pa•e 9
S QTY ID DESCRIPTION _._.
1 WC MODULE STEPWELL:
X < . 1 Step;.Electric,Zico Retractable'with switch • - •
SHOP NOTE:
SR 213936F..,` _ •
New Rockford design
Zico VS-24-11 Quic Step Vehicle Step 10.5" drop retractable step. With switch manual switch
on curbside door
NO Drop skirt!
1 WC _ Step Well, Removable Grate, W/Drain, ILOS
1 WC MUD FLAPS:
1 WC Mud Flaps, Rear, W/Logo, Std Model only
1 WC PAINT/BELTS:
• > < 1 WC Paint, Entire Unit, 20% Upch
SHOP NOTE:
Sikkens paint code, Red#FRE 3015
spray out is approved 12/17/12 at pre construction meeting
Note: *Module roof and module drip rail to remain Ford OEM White. Ford white: FA91:YZ
ENG. NOTE:
Must pick 20% upcharge option for all red/metallic paint.
If Sikkens paint code is not known, use.PDF form
structured to"Single Belt"option.
Dealer/DSM to request sprayout prior to order submissionilill
X < 1 Paint Wheels (5) ILOS
SHOP NOTE:
(SO-PT-311214) SR#214923F
(5)Wheels, Outer's and SPARE tire. paint code Red#FRE 3015
1 WC - CHEVRON PACKAGES INSTALLED: 0•
> < 1 WC Chevron Striping, Full Rear including doors, 6" Diamond Grade Reflective
SHOP NOTE: • . •
To be installed by 24/7 Graphics
•
COLORS: NFPA Red/Yellow
ENG. NOTE:
• Standard COLORS:.
Red, White, Fluorescent Yellow/Green, Solid Yellow
•
1 WC DECAL PACKAGES INSTALLED:
1 WC - • Roof Star; White Border, Installed, Std Model Only
< 1 WC ELECTRICAL SYSTEM: Circuitboard
SHOP-NOTE:
See Center console layout re ference.pdf on the server in the work order folder. Note customers
last unit 311.114-5 '•
1 WC COAX CABLES/ANTENNAS: •
X < 1 Specified Antenna installed SR 213095F ILOS
SHOP NOTE: •
SR 214923F
•
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:07 Pa•e 10
S • QTY ID DESCRIPTION _
(SO-ANT-311214)
. 2- Laird A150S VHF unity,gain antenna with spring plus associated nmo mount ILOS.
Laird A150S (1) Port 2 to terminate in CC
(1) Port 5 to terminate at the circuit board •
Laird TRA 7603 (1) Port 3 to terminate in CC.
1 - Laird TRA7603 UHF 3db low profile antenna plus associated nmo mount installed ILOS 70176
. - Laird TRA4503: 450-470 Phantom Antenna, White RF
Cable with NMOK Motorola Style roof connector
•
Laird 4503 (1) Port 4 to terminate at circuit board.
1-..- Laird TRA4503 7/800 MHz 3db low profile antenna plus associated nmo mount ILOS
304'196-Laird
TRA7603: 760-870 Phantom Antenna, White RF Cable with NMOK Motorola Style roof connector
Laird GPS Puck (1) Port 1 to terminate in CC.
1 - Laird GPSTW821/18503P Tri-Band antenna puck Installed ILOS 362638-
GPSTW821/18503P: Tri Band Ant, TNC/SMB White
1 WC 12VDC POWER SOURCES &OUTLETS:
> < 1 WC Outlet, Cigar Lighter, STD, (2),A/A
SHOP NOTE:
•
On 20-amp ignition hot circuit. ("elect batt sW')
ENG. NOTE:
- Any,combination of 2-outlets may be used on a single power source. . Outlets are available for
use with 15 and 20 AMP power sources only.
> < 1 WC Outlet, Cigar Lighter, IATS, (1)
SHOP NOTE:`
Ignition hot
(1) RF cabinet E3,wall 2, up high and to the right.
Prod/Eng_note Rev 01 CO deleted 1 of these from RF/E1
ENG. NOTE:
Any combination of 2 outlets may be used on a single power source. Outlets are available for
use with 15 and 20 AMP power sources only. •
1 WC POWER SOURCE, 12 VDC
< 1 WC Power Source, 12VDC, 20A, Ignition/Shoreline Hot
SHOP NOTE:-.
20amp 12 volt DC circuit ran to two locations, (1) pre-wire coil and tagged in action area and (1)
pre-wire coil and tagged behind driver's seat.
> < 2 WC . Power Source,12 VDC,10 Amp (+-)
SHOP NOTE:
•
(1) Ignition hot to cab console
(1) Ignition hot to action area behind sw panel
ENG. NOTE:
All power sources-will-be terminated with a six foot tail unless outlets or junction-posts are also
ordered. State location in shop notes.
•
> < 1 WC Power Source,12 VDC,15 Amp (+-), Std Model only
SHOP NOTE: " • -.. •
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa.e 11
S QTY ID• - DESCRIPTION
(1)constant hot, terminating in cab console for MDT
with 6 foot tails(hot.and.ground). •
• ENG. NOTE:.
All power sources will be terminated with a six foot tail unless outlets or junction posts are also
ordered: State location in shop notes.
> < 2 WC . Power Source,12 VDC,20 Amp.(+-)
SHOP NOTE:
(1) For Cab radio - Constant Hot to cab console
(1)Ignition/SL for dealer installed Medi Kool . terminate in upper El near wall 1
- ENG. NOTE:
All power sources will be terminated with a six foot tail unless outlets or junction posts are also
• ordered. „State location in shop notes.
> < 1 WC Power Source,12.V DC,30,Amp_(+-),,Std.Mo del only •
SHOP NOTE:
Constant Hot,to terminate_in-CB area for module radio
,with 6 foot tails (hot and ground).
ENG. NOTE:
All power sources will be terminated with a six foot tail unless outlets or junction posts are also
ordered. State location in shop notes.
1 WC ELECTRICAL ACCESSORIES
X < - 1 Camera, Hansco m_ K#HC430RVM rearview mirror_
SHOP NOTE:_
SR#214923F
(SO-CAM-311214) Ref(SO-CAM-311115)
make sure mirror bracket fits Orr a 2011 F450
Mount camera.exterior on rear of module, off center .
toward driver's side, above rear entry door.
(1)#HC430RVM rearview mirror with 4.3" integral monitor,
(1)#IR250 Camera, black or white, with 35'of cable. •
1 WC • _ , • • - SHORELINE INLETS:
> < 1 WC Super Auto Eject, 20 amp, ILOS, Red, Std Model Only
SHOP NOTE:. _ -
With red cover; mounted above compartment"E"
ENG. NOTE: •
Auto eject with interrupter to prevent sparking if under load when ejected.
State location of inlet in shop notes. Cannot be mounted on front of modular body. SR and
custom angled bracket required for MAV front body mounting only.
1 WC 110 VAC OUTLETS:
< 1 WC Outlet, 110 VAC, Duplex, (2),STD __
SHOP NOTE:
(1)outlet in action area
(1) RF cabt E3 wall 2 up high and to the right.
-
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•a 12
S QTY ID 'DESCRIPTION
> < 1 WC Outlet, 110 VAC, Duplex, IATS
SHOP NOTE
(1)AA:down low at REAR;end of AA by CPR seat. _
Prod/Eng note Rev 01-CO deleted 1 of these from RF/E 1 • •
ENG. NOTE:
State installation location in shop notes.
'1 WC BATTERY CHARGERS:
> < 1 WC Circuit, Battery. Charger Power Acces.
SHOP NOTE:
110 Relay to switch to 12VDC power.
•
•
ENG. NOTE:
- 110 Relayto-switch to 12VDC power. .
Allows_auxillary lights to be powered by the battery charger when the shoreline.is plugged in.
> < 1 WC Battery Charger,Kussmaul, Auto 1200,40 amp W/Rem Ind
SHOP NOTE:
•Charger/Conditioner mounted in battery tray in batt compt
wired to the battery in the RF compartment only.
Kussmaul remote indicator panel installed next to SL inlet above compt E.
ENG. NOTE:
Charger/Conditioner
1 WC . • GAUGES/METERS:
< 1 WC Meter, Analog, Volts, F1
SHOP NOTE:
On Center Console SWITCH panel.
1 WC • ENGINE HOUR METER:
> < 1 WC Meter,Engine Hour, Datcon 100-223 12-24
SHOP NOTE: -
mounted on driver's side of cab console.
ENG. NOTE:
Located in cab console. ..
< 1 WC •-• •SEQUENCING/LOAD MANAGEMENT: .
SHOP NOTE:
Eng note,Sameas 311114.-5-Engineering note see customer ref picture on the server in the work
order folder for reference.
> < 1 WC Sequencer,Kussmaul,Load Manager, W/Switch
SHOP NOTE:
W/Sequencer switch and override on.console
ENG. NOTE:.
ON SEPERATE SWITCH THROUGH MASTER.
•
•
•
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•e 13
_ S QTY ID _ DESCRIPTION
1 WC SIREN SPEAKERS:
< 1 WC Siren Speakers, Cast SAD/P3806-11FSD-1, F1, 2011+, Std
SHOP NOTE:
Thru Front Bumper -
1 WC . - • SIRENS: • -
> 1 WC Siren, Whelen, WS-295-SLSA1, Standard
ENG. NOTE::
If more than (1) siren is requested s.r. required.
can be programmed to a WS-295HFSM1
1 WC AIR HORNS:
X < 1 Brackets, Airhorn Thru Bumper, F350/F450, 2011+
SHOP NOTE:
(SO-BRKT-321174)
Per Eng design trumpets to be as_close to the bumper as possible & both trumpets will be a
even distance from bumper.
> 1 WC Additibnal,Air Tank,For Buell Air Horns
ENG. NOTE:
Buell Air horns only .
> < 1 WC Airhorn, Buell, 5440 comp, Dual-10 inch horns
SHOP NOTE:
mount compressor.on fixed shelf in compt"E"
ENG. NOTE:
Dual 10" horns
1 WC SWITCHING OPTIONS FOR AIR HORNS &SIRENS:
1 WC Switch, Siren/Horn Thru Horn Ring
> < 2 WC Switch, Add, 12VDC Momentary Rocker.
SHOP NOTE:
- On CC switch panel driver-and passenger side for operation of air hornsSanie as311114-5.
ENG. NOTE: •
STATE FUNCION AND LOCATION IN SHOP NOTES.
1 WC SWITCHES ADDITIONAL:
> < 1 WC 3-Way Switch, Dome Master Circuit
SHOP NOTE:
(1) switch on CC switch panel
(1) switch inaction area. -
- ENG.NOTE:-- - -
This will allow you to turn off the interior Dome Its from Cab. State if additional interior Its will be •
controlled
> < 1 WC Switch, Momentary, Rocker, (1)
SHOP NOTE:
In AA lower panel to activate 15 minute check out light timer
IATS Switch to allow activation and also deactivation. Wire to dome lights.F-G=H in liner. High
intensity
ENG.;NOTE:. . .
STATE LOCATION-OF SWITCH AND PURPOSE IN SHOP NOTES.
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•a 14
S QTY ID DESCRIPTION•
1 WC AUDIBLE ALARMS:
1 WC Alarm, Back-Up, Auto Reset, Std Model'only
1 WC VEHICLE EXTERIOR LIGHTING
X < 1 Emitter, Tomar#EMIT20-LBUG
SHOP NOTE:
SR#214923F
(SO-OPTI-311054) Inst in Cool Bar, Center, above center clear.
•
Tomar#EMIT20-LBUG Preemption Emitter
Separate switch prim only and in gear only.
X < 1 . Chrome Bezel, Tomar#RECT-37-SMFP
SHOP NOTE: •
(SO-LT13-311054)for Emitter lamp
X < 1 Whelen TANF 85 LED Lightstick
• SHOP NOTE:
(SO-TA-321117) SR 214923F
Whelen TANF85 8-lamp linear-LED Traffic Adviser, approx 46.75".long, T.ACTLD1 control head.
mounted.above load lights • • • -
- Mount control head in cab per Engineering.
1 WC WHELEN FLANGES FOR 9E SERIES LIGHTS: .
16 WC Flange, Super 9L, #90FLANGC, (1) Each
4 WC Flange, 97 Series, (1) Each • -
> 1 WC WHELEN SUPER LED 9L STEADY BURN LIGHTS T1,3,9:
• ENG. NOTE: . • -
Requires external flasher.
Specify switching and flasher.
Pick proper flasher separately.
> < 8 WC • Light;9L, Super LED;Whelen, Red,Red Lens,ILOS, 9ORR5SRR
SHOP NOTE:
(2)each side standard location •
(2)Front module upper outer corners
(2) Rear Module Upper outer.corners
Pri/Sec,through AFM.560 flasher
•
• ENG. NOTE:
Requires external flasher.
Specify switching and flasher.
Pick proper flasher separately.
•
> < 4 WC • Light, 9L, Super LED;Whelen,Red,Red Lens,IATS, 9ORR5SRR
SHOP NOTE:
(2)to show through the lower area of rear windows.
Pri/Sec, through AFM 560
Steady burn when brake is applied &emerg lights are on.
(2)Cool Bar one-each side of center clear - - • •
Pri/Sec through AFM 560 flasher
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 0 Pa•e 15
S QTY ID DESCRIPTION
ENG. NOTE:
Requires external flasher.
• Specify switching and flasher.
Pick proper flasher separately. •
> < 1 WC Light, 9L, Super LED, Whelen,Amber,Amber Lens,ILOS, 90AA5SAR
SHOP NOTE: .
on rear to show upper window area (replaces ctr amber)
ENG. NOTE:
Requires external flasher.
Specify switching and flasher.
Pick-proper flasher separately. •
> < 1 WC ' Light, 9L, Super LED, Whelen,Amber,Amber Lens,IATS, 90AA5SAR
SHOP NOTE:
on rear to show upper window area
Pri/Sec through AFM 560 flasher
ENG. NOTE:
Requires external flasher. •
Specify switching and flasher.
Pick proper flasher separately.
> < 2 WC Light, 9L, Super LED, Whelen, R/C, Clear Lens,IATS, 9ORC5SCR
SHOP NOTE:
(2)Cool bar angled area
Prim only-through AFM 560 flasher . •
•
ENG. NOTE: _ ,
Requires external flasher.
•
•
Specify switching and flasher.
Pick proper flasher separately.
1/2 Red, 1/2 Clear, Split top to bottom
•
•
1 WC 5 SERIES(TIR6) SPLIT LED LIGHTS:
> < 3 WC Light, 5L TIR6,_Whelen,Red, Red Lens,5ORR3ZRR, IATS
SHOP NOTE:
(3) Installed on the Rear and CS entry door interior panels lower outer corner's
Wired: Ignition Hot • .
to flash when door is opened, through lights internal flasher, factory default
ENG. NOTE: "
Does not require external flasher.
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa.e 16
S QTY ID DESCRIPTION
Specify-.switching and lighthead-flash pattern.
Pick appropriate flanges -
Does not meet KKK for light output
•
1 WC 5 SERIES(LIN6) NON-SPLIT LED LIGHTS:
> < 2 WC Light,5L LIN6,Whelen,Red,Red Lens,50RO2ZRR, Std, F1/D1 Only
SHOP NOTE:
(2),as grille lights
wired thru AFM560 flasher, Prim only
ENG. NOTE:
Application(s): F-450, Dodge T1, '08 E-Series Grille, & Other optional locations
•
Does not require external flasher.
•
Specify switching and lighthead flash pattern.
Pick appropriate flanges
1 WC WHELEN 5E. FLANGES/HOUSINGS:
> 2 WC . Housing, 5L Series,-#5LSMAC, (1),Std, F1/D1 Only •
ENG. NOTE:
Deep housings
• 3 WC Housing,_5L Series, #5LSMAC, (1} - • - -
ENG. NOTE:
Deep housings
1 WC - WHELEN SUPER LED 7L LIGHTS W/FLASHERS:
> < 2 WC Light, 7L, Super LED, Whelen, Red, Red Lens, IATS, 70R02FRR
SHOP.NO.TE:
Rear inter sectors over rear wheel wells.
•
Pri only through lights internal flasher cornet flash
ENG. NOTE:
Does not require external flasher.
Specify switching and lighthead flash pattern-
> < 1 WC Light, 7L, Super LED, Whelen, Clear LED, IATS, 70CO2FCR
SHOP NOTE: -. - -
Center clear 7 series LED under&Tomar in Cool Bar see drawings.
Primary Only Shut down in Park/Neutral internal flasher comet flash
ENG. NOTE: -
Does not require external flasher.
Specify switching and lighthead flash pattern.
1 WC - - WHELEN FLANGES 7 SERIES LIGHTS -
< 3 WC Flange, Whelen, For 7E lights (1), Mods
SHOP NOTE: -
- For 7 Series Lights
•
PDF created with pdfFactory trial version www.pdffactory.com
•
11/02/2014 16:14:08 Pa'e 17
S QTY ID DESCRIPTION
1 WC INTERSECTION LIGHTS, 2011+ FORD F-SERIES,WHELEN
< 2 WC Light, Whelan, LINZ6R, LED-Red,•Std,Ford F-Series Only - - • • -
SHOP NOTE:
(2)front intersectors with chrome flanges .
prim only default flash pattern internal flasher
1 WC 'CORNER CAP LIGHTS
< 1 WC Corner Cap Lts,Multi-LED,(2)Amber(2)Red w/Flashers,Std Model
SHOP NOTE:
- High intensity flashers; thru separate switch
1 WC CLEARANCE LIGHTS:
< 3 WC Light, Clearance,Amber.LED, IATS.
SHOP NOTE:
Module front
< 3 WC • Light, Clearance, Red LED,'Std Model only •
SHOP NOTE:
• - On rear as clearance.lights. •
1 WC - SCENE AND LOAD LIGHTS
< 4 WC Light, Halogen, Whelen, 9H, Clear, 8-32 Deg, STD, (1)
. SHOP NOTE:
- (2) each side as scene lights
•
< 2 WC Light, Whelen, 7H, Clr, 8-32 Scene, ILOS
SHOP NOTE:
Rear Loads ILOS no Center amber.
Lights per drawings..
•
> 1 WC Scene Lights, C/S, Activated W/C/S Door
• ENG: NOTE: -
MASTER SWITCH HOT.
1 WC FLASH PATTERN WARNING LIGHTS:
< 1 WC Brake Override Circuit
SHOP NOTE:
Rear window IATS lights to steady burn brake in emergency mode Ref 311114-5 .
< 1 WC Automatic Secondary, Park/Neutral,-W/Momentary Switch, Auto Reset
SHOP NOTE:
• Placing.vehicle in park will.shut off all forward facing clear, red/clear, grille lights, front inter
sectors and rear inter sectors.
1 WC WARNING LIGHT FLASHERS
> < 1 WC Flasher, Whelen AFM-560, ILOS
SHOP NOTE:
Set flash pattern to Comet Flash •
ENG. NOTE:
Must specify flash pattern:
Single Flash(default)
Signal Alert Freedom
Comet Flash • _ •
Double Flash
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•e 18
S QTY ID DESCRIPTION _ _
1 WC HARNESS LAYOUT:
1 WC Halogen, " E"Spec, V1lhelen-.
t WC STOP/TURN/TAIL LIGHTS:
< 1 WC . Light, License Tag, (2),:Grote 60101, STD
SHOP NOTE:
(incandescent). - -
< 1 WC Tailights,Whelen,LED Stop/Tail,Halogen/Backup, w/WC logo -
SHOP NOTE: •
- Brake-Alert Flash before the steady Burn
-Turn Arrow—sequential arrow
1 WC MODULE OVERHEAD HEADLINER:
1 WC- Headliner, Flat, Expanded PVC, 160"+ MAV/Type 1
1 WC 12VDC INTERIOR LIGHTING:
1 WC Lights, Dome, LED, Whelen.#8000EHCR, (4) S/S, (3) C/S, ILOS
< 3 WC Light, Dome, LED, Whelen#8000EHCR, IATS
SHOP NOTE:
Liner positions F G=H
1 WC Light, Stepwell;Trucklite, 2in, Std
< 1 WC Light, Intertek ZY-PIR38 12v, LED, In A/A ILOS
SHOP NOTE: •
in A/A, installed on bottom of"L"cabts.
1 WC SWITCHING OPTIONS FOR 12VDC INTERIOR LIGHT!
> < 1 WC Switch, 12 VDC, (1), For Additional Lights . •
SHOP NOTE:
In AA sw panel Hi/Low/Off IATS for lights in liner positions F-G-H
ENG. NOTE:
STATE LOCATION OF SWITCH AND PURPOSE IN SHOP NOTES. -
1 WC • LIGHTS&MISCELLANEOUS:
X < 1 Spotlight, GO LIGHT, White#2021
SHOP:NOTE: •
SR#214923F
SO-GOLT-311153
Go Light White#2021
Mount centered in cab roof with remote on ECC as,per Ford 2015 Headliner-instrucitons.
1 WC Spotlight,,Blue-Eye, 400,000 CP, Std'Model only _ .
> < 1 WC Lights,(2), 4in, LED, to Ilium Running Boards, Constant Hot
SHOP:NOTE: - • -
Activated with the cab-doors.
ENG. NOTE:
Mount in front stoneguards. Activate with cab doors, constant hot.
< 1 WC Lighting, Compt, LED Hi-Brite Flex, ILOS
SHOP NOTE: .
both vertical edges near,doorjambs and across top edge .-
near door jamb, compts "A", "B1" "B2", "D", "E", &"F".
Retain 2"02.Iight.
PDF created with pdfFactory trial version www.pdffactory.com
• 11/02/2014 16:14:08 Pa•a 19
S QTY ID 'DESCRIPTION "
> < 1 WC Timer, Momentary Sw,15 Minute, Constant Hot, Std Model only
SHOP NOTE:
Eng note see added momentary switch.
Mount switch on C/S wall at the head of the squad bench •-
in the standard location. Switch to allow activation and
. , - also deactivation. Wire to center dome lights in liner. (High)
ENG. NOTE:
STATE LOCATION OF TIMER AND WHICH LOAD IS BEING POWERED IN SHOP NOTES.
< 1 WC Light, in Circuit Board Area, for Electrical Troubleshooting
SHOP NOTE:
-with integral switch; wired constant hot.
1 WC CLOCKS:
> < 1 WC Clock, Analog, Self Cont, 12/24 Hr, 8"
SHOP NOTE:
•
LOCATION: above rear entry doors
ENG. NOTE:
•
Default location: above rear entry doors
1 WC SUCTION PUMPS:
1 WC Suction Pump, Standard
1 WC INSULATION:
> < 1 WC' Insulation, Severe Weather Package
SHOP NOTE:
one inch block foam in modular floor,walls and roof covered with reflective insulation. - •
• - All edges of reflective insulation on walls and ceiling must be taped, std. - •
ENG. NOTE:
One inch block foam in modular walls, floor and roof, covered with reflective insulation.
1 WC GRABRAIL(S)/GRABHANDLES:
1 WC Grabrail, Overhead, 117 In, Stainless, Handicap Style
< 1 WC Handrails,(3),Custom-"L" Shape,1"-SS, Entry Drs,Std Model
SHOP NOTE:
For units with Trimark handles.
•
Stainless Steel Grab Handles ILOS .
> < 1 WC Grabhandle; 1"X 13.5", Aluminum, (1), On Exterior, IATS
SHOP NOTE:
•
OutsideCS'Entry Door -•
ENG. NOTE:.
STATE INSTALLATION LOCATION IN SHOP NOTES.
1 WC 02 CYLINDER RACKS:
1 WC Rack, Multiversal, #QR-MV, W/Straps
1 WC Track, Unistrut for Oxygen Rack
1 WC 02 SYSTEMS COMPLETE: -
> < 1 WC 02 Sys, LF Stor, (2) O2Nac Port-NA, (1)02-Liner, (1)02 C/S
SHOP NOTE:
See ref drawing AA layout 02-02-Vac(vac port close to suction container)
Ohio style•
(2) oxygen outlets in action area
PDF created with pdfFactory trial version www.pdffactorv.com
•
11/02/2014 16:14:08 Pa•e 20
S QTY ID DESCRIPTION •
_ (1)•vacuum port in action area
(1)oxygen outlet in liner at head of cot•
(1) oxygen outlet cs wall at head of squad bench
ENG. NOTE:
2 OXYGEN OUTLETS,VACUUM PORT IN ACTION AREA,
1 OXYGEN OUTLET IN LINER AT HEAD OF COT,
1 OXYGEN OUTLET CS WALL AT HEAD OF SQUAD BENCH.
1 WC 02 SYSTEM PARTS:
1 WC Regulator, Oxygen Cylinder, Preset 50PSl, Installed
1 WC .. SUCTION CONTAINERS: • •
> < 1 WC Regulator/Holder, SSCOR 22000, Std Model only
SHOP NOTE:
Relocate Suction Bracket and canister forward in A/A to under the AA switch panel. See
drawings for reference.
ENG. NOTE: .
with stainless steel container bracket •
•
1 WC COT MOUNTS:
X < 1 Install Stryker Power Load System . , • • .
SHOP NOTE:
SR 214923F •
Provide and Install Stryker power load system.
1 WC • IV HOOKS:
> < 2 WC IV Hook, Perko, (1), W/Straps, STD
SHOP NOTE:
curbside and street side standard locations
ENG. NOTE:
State installation location in shop notes. . •
•
> < 2 WC • IV_Hook, Cast, Fold Down Recessed, IATS •
-
SHOP NOTE:
. IV2 SS and IV2'CS
• • ENG. NOTE:
State installation location in shop notes.
•
1 WC KICK PLATES STAINLESS STEEL, ON CABINETS:
1 WC Kickplate, Brushed S/S, Face Of Squad Bench
1 WC Kickplate, Brushed S/S, On Face of Basewall
1 WC Kickplate;Brushed SS,Head of Squad Bench -
1 WC MISC. INSTALLED HARDWARE/EQUIPMENT:
1 WC Squad Saver Bar, Fold Down On.C/S'Wall,.Mods
> < 1 WC Wrench, Oxygen, Tethered, Mods
SHOP.NOTE:
in oxygen compt.
ENG. NOTE:
State installation location in shop notes.
1 WC DRI-DECK/TURTLETILE: ' •
• 1 WC Dri Deck, Black, All compt. Floors and Shelves
ENG. NOTE:' •
Only covers 50 square feet. If more is required, increase quantity !!!! (allow for waste)
Pick (3)for SRV's
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•e 21
S QTY ID - • DESCRIPTION •
1 WC MODULE INTERIOR
1 WC • Interior Cabinets- Duralite Construction, Wood •
1 WC MICA COLOR:
1 WC • Mica,Dove Gray Over Pewter Brush
1 WC SUB FLOORING:
1 WC Flooring, Wood, Type 1; Std . -
1 WC FLOORING:
1 WC - Flooring,Lonplate II,Gunmetal Grey#424, Std Model only
1 WC SEAMLESS ATTENDANT SEATS:
< 1 WC Seat, Attendant, EVS,.Chiild,Gunmetal#1880CB, Std Model only`. ,
SHOP NOTE:
Vacuum formed EVS1880CB w/3 point seatbelt.
. Integrated child safety seat.
Mounted metal box base.
1 WC SEAMLESS UPHOLSTERY:
• 1 WC Uph, Smless, Gunmetal,No Bio,No Post&Wheel
1 WC 02 DOOR:
1 WC ' Lexan Flaps, Hinged Left Side, Fixed Right Side, Std
1 WC GLOVE HOLDERS:
-1 WC . Cabinet, Glove Box.Holder,(3),Above C/S door, Std Model only - • .
1 WC RIGHT FRONT CABINET:
X . < 1 ..- Cab, RE,'W/O Healthguard, AC/Combo, Custom
SHOP NOTE:
(SO-RF-31.1215) SR 212936F _ . .
Top-El Designed to fit a MK Saline unit that the dealer will install
Middle-E2- 5 inch drawer centered.
Bottom-E3=lSOS access, max height -
Use safety net ILO door on E3
X < 1 Medi Kool Saline.Drawer RF El location
SHOP NOTE:
SR 214923F -
Provide / Install Medi Kool Salime MK Drawer RF El location. Provide Left or right compressor
' location - '
Exterior thermostat control on RFC facing the Attendant seat see drawings.
Cabinet is 23.25Wx 20.5D x 11.76 H. • • . -
X < 1 Net, (1), RFCabt ILOS ,
SHOP NOTE:
(SO-RFNET-311215)
Open area (E3)to have a net, attached on the
horizontal aspect of RF cabinet.
E3 to have 3 individual sets of straps, 2 horizontal and 2
vertical attached to RE'cab horizontal only. Each strap
section will cover area above and below shelf.
1 WC HARDWARE,LATCHES AND LOCKS:
X < 3 Latch, SouthcoM1-62-8.2lN BIk, Non Locking, (1) IATS •
SHOP NOTE:
(SO-LOCK2-303217) SR 211458 .
(2) Splint cabt doors
(1) K2 Door . .
X < 1 HA25632- Lock, Simplex, 9040000-26D-41
SHOP NOTE:.-: - : - - - ' - . '
(SO-LOCK-311001)
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa.e 22
S QTY ID DESCRIPTION
installed on cabt"E2".drawer
> < 3 WC Handle, Black,Flu_sh Pull Ring, Round,3/4" Panel, IATS
SHOP NOTE:
(1)Qdoor to SB 02 storage
(1)Tilt out Cabinet 0
(1)AA drawer -
ENG. NOTE:
MUST STATE MOUNTING LOCATION IN SHOP NOTES.
Pictures shows locking but this code is for non-locking
> < 1 WC Latch, Southco M1-64-8, 21N S/S, Non-Locking, (1), IATS
- SHOP NOTE:
(self latching) Flush Mount. Non-Locking
(1) E2 drawer
ENG. NOTE:
(for 3/4"door !I)
STATE INSTALLATION LOCATION IN SHOP NOTES.
< 1 WC . • - SQUAD BENCH:
SHOP NOTE:
Squad bench description updated as built Rev 02 WO .
X > < 1 Squad Bench;Custom
SHOP NOTE:
SR#214923F •
- ,(SO-SB-281019) Same as 311114-5
Custom Squad Bench
. Interior SB"Q"area to have 8.25"deep storage. •
(3) 'D'cylinderstorage-accessed from head end of SB. .
Box in for cylinder storage as small as possible to allow
maximum space.fo"r interior storage Q . •
• Refer to revised CA drawings for seatbelt locations
(so that the lower receivers line up with upper pull out belts).
Cylinder storage areas to have have nylon strips on
each side that will cradle 02 cylinders, see drawings.
(Nylon strips will be mounted below center of cylinder, ilos)
Cylinder storage door to have rubber bumpers on the
• door, upper outer corners.to allow the door to open fully
to allow for cylinders to fit into space.
ENG. NOTE:
w/EMS•right rear comets°B1"&"B2"•: . .
1 WC LID 170 INCH BOX:
• 1 WC Lid, Squad Bench, Split 50/50
ENG: NOTE:. • • • • -
split lids require 2 latches and 2 hold open devices.
•
PDF created with pdfFactory trial version www.pdffactory.com
•
11/02/2014 16:14:08 Pa.e 23
S QTY ID • DESCRIPTION
1 WC • HARDWARE:
2 WC Handle,Trimark; Squad.Bench, STD. "
2 WC Prop, Lid, Jedco, 90/180 Deg, 8in,
1 WC CURBSIDE SPLINT CABINET 160-170 inch Module • .
X > < 1 CS Splint,7in Deep,2 Sect, Gray Lexan ILOS
SHOP_NOTE: •" '
(SO-SSU-311092) 3/8s gray lexan flip up flaps ILOS slider's
as close to KKK compliant as possible design
•
•
ENG. NOTE:
for use with 163 10 inch ext
1 WC - . CURBSIDE REAR CABINET:
1 WC Cabinet, Curbside Rear, Standard, 170 In
1 WC CABINET H, BASEWALL 170", T1/T3 •
1 WC H, Cabinet, full depth, std
1 WC - CABINET I, BASEWALL 170", T1/T3 - , . -
1 WC I, Cabinet, Deleted
1 WC CABINET M, BASEWALL 160"& 170", T1/T9 • "
1 WC M, Cabinet, full height
1 WC CABINET 0, BASEWALL 160-170", T1/T3
XS > < 1 WC 0, Cabinet, Custom
SHOP NOTE: -
(SO-O-311115) SR214923F
Custom 0 cabinet
Dimensions: 15"h x 21.75"w x 19.5"d
*Wood door hinged at bottom.
*Add (2)cables to hold door at approx. 30 degrees.
ENG. NOTE:
•
DSM - Remember to check the"S" box.
1 WC CABINET CPR, BASEWALL, 149"-17.0", T 1 &T3
1 WC CPR, side:seat, Std Model only •
1 WC CPR, side seat, flip up lid, Std Model only
1 WC . - • CABINET J, STREETSIDE UPPER 170", T1/T3
XS > < 1 WC J/K Cabinet Custom ILOS
SHOP NOTE: . .
SR#214923F
• (SO-J1K-311214)
Combine J and K into one large cabinet
ENG. NOTE:
DSM-Remember to check the "S" box.
< 1 WC . CABINET K, STREETSIDE UPPER 160-170",.T1/T3
SHOP NOTE:
J/K cabinet combined into_one large Cabinet - r
S < 1 WC K2, Cabinet,w%CPR seat_ILOS S •
SHOP NOTE:
(SO-K2-311214) 3/8 gray lexan flip up door ILOS ,
1 WC - - CABINET L,STREETSIDE UPPER-160-170",-T1/T3 •
PDF created with pdfFactory trial version www.pdffactory.com
•
11/02/2014 16:14:08 Pa•e 24
S QTY ID DESCRIPTION
1 WC _ L, Cabinet, L1, L2 Combine into 1 Large Cab, 72" H.R, Full F
1 WC - • = . 'BASEWALL DOORS:
1 WC Cab H, Gray Lexan Slider
1 WC Cab M Gray Lexan Slider • - • -
1 WC ACTION AREA WORK SURFACE
X < 1 . 'Action Area Tray, Stainless Steel, ILOS•
SHOP NOTE:
(SO-TRAY-311214) Ref(SO-TRAY1-321111) SR#214923F
1 WC ACTION AREA 165/170 INCH BOX:
1 WC Cab,A/A,Without Biowaste, 170"Type 1
X < 1 Writing Tray, Slideout Drawer,Under A/A Tray
SHOP NOTE:
• (SO-AA-311045)
Per Eng design 35"deep drawer with a lexan lid on top of drawer.
> < 4 WC Shelf, Interior, Adj, in Cabinet:- •
SHOP NOTE:
(1) J/K
(1) L
(1) H •
(1) M
ENG. NOTE:
Upgrade to non-wood shelves for the Fire Medic Series
> < 4. WC Shelf Track, Cabt,#HA24663, Upgrade, Std Model only
SHOP NOTE:
("C"channel/exterior shelf style track)
(1)J/K
(1) L
(1) H
(1) M
ENG. NOTE: •
exterior comet style shelf track.
•
1 WC Cab"J/K" Combined, Gray Lexan Slider
1 WC Cab."L1,L2,L3'.' Combined, Grey Lexan Slider , •
ENG. NOTE:
Not functional on std 11,12,13 recommend
wood door w/lock
1 WC • SHIP LOOSE ITEMS:
> 1 WC Bracket, Spare Tire Mounting, Ship Loose
ENG. NOTE: .
State installation location in shop notes.
X < 1 5 qt Sharps disposal and mounting bracket
SHOP..NOTE: .
(SO-SL-311214) SR 213923F
Armstrong Medical-5 qt-Sharps disposal and mounting bracket for customer install. Ship loose
Boundtree#298507SA 5-quart transparent red sharps container and#298516 wall enclosure with
lock . • -
1 WC Ship Loose, W.C. Standard Items
•
PDF created with pdfFactory trial version www.pdffactory.com
11/02/2014 16:14:08 Pa•e 25
S QTY ID DESCRIPTION
1 WC Spare Tire, OEM only, Ship Loose
ENG. NOTE:'
(Must purchase separately on type 9's) limn
1 WC WARRANTIES
.1 WC Warranty, Lifetime, Mod Electrical
S > 1 WC Warranty, Lifetime, Mod Structural
ENG. NOTE:
There is a $250 charge for this warranty that will be applied on the re-cap. (Sales Eng will move
from work order to recap)
S > 1 WC Warranty, Limited Lifetime, Mod Paint
ENG. NOTE:
There is a $250 charge for this warranty that will be applied on the re-cap. (Sales-Eng will move
from work order to recap)
•
S > 1 WC Warranty, Extended, 3 Y ear/36K Miles, Types 1, 3, 9
ENG. NOTE: -
There is a $1000 charge for this warranty, that will be applies on the re-cap. (Sales Eng will
move from work order to recap)
Not valid on Type 7 Moduvans !!!!
1 WC Labor, Addtional, 1/2 Hour
1 WC End Of Order _
ENG. NOTE:
•
•
•
•
•
•
•
•
PDF created with pdfFactory trial version www.pdffactory.com