Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
05-137
' Resolution No. 05-137 RESOLUTION AUTHORIZING EXECUTION OF A LEASE AGREEMENT WITH VOICESTREAM GSM I OPERATING COMPANY, LLC (T-MOBILE-USA, INC.) BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN,ILLINOIS,that Olufemi Folarin,City Manager,and Dolonna Mecum,City Clerk,be and are hereby authorized and directed to execute a Lease Agreement on behalf of the City of Elgin with VoiceStream GSM I Operating Company, LLC, for establishment of a cellular communications tower at Fire Station No. 4 at 599 S. McLean Boulevard, a copy of which is attached hereto and made a part hereof by - reference. s/Ed Schock Ed Schock,Mayor Presented: April 27, 2005 Adopted: April 27, 2005 Omnibus Vote: Yeas: 7 Nays: 0 Attest: s/Dolonna Mecum Dolonna Mecum, City Clerk I City of Elgin Wireless Communications Equipment Site Agreement with VOICESTREAM GSM I OPERATING COMPANY, LLC for the use of City of Elgin Fire Station No. 4 599 South McLean Boulevard CH37-975 TABLE OF CONTENTS SPECIAL TERMS AND CONDITIONS Section I. Premises • Section II. Use/Purpose Section III. Site Agreement Contents Section IV. Term Section V. Rent/Consideration Section VI. Insurance and Liabilities Section VII. Termination Section VIII. Other Special Conditions Section IX. Effectuation of Agreement GENERAL TERMS AND CONDITIONS Section I. Definitions Section II. Specific Agreements A. Relationship to Site Agreement B. General Planning, Engineering and Design Considerations C. Acknowledgment and Acceptance of Risks D. Payment to Facility Owners E. Term and Termination F. Modifications to Facilities G. Requirements for Installation H. Modifications of Equipment I. Performance of Work J. Access and Maintenance K. Rights of Property and Easements Section III. Company and Contractors Requirements A. Contracts B. Approvals C. Release, Indemnity and Hold Harmless D. Worker's Compensation, Insurance and Bond E. Permits F. Compliance with Laws and Requirements G. Nondiscrimination and Affirmative Action H. Sexual Harassment Section IV. Additional Conditions and Provisions A. Non-Waiver B. Assignment; Successors and Assigns C. Survival D. Entire Agreement E. Applicable Law F. Severability G. Rights Cumulative H. Contractual Relationship I. Headings J. Notices K. Non-Exclusivity L. Modification or Amendment SPECIAL TERMS AND CONDITIONS THIS AGREEMENT is entered into by and between THE CITY OF ELGIN, an Il- linois municipal corporation (hereinafter referred to as the "City"), and VOICESTREAM GSM I OPERATING COMPANY, LLC a Delaware limited liability company (hereinafter referred to as "Company"). WHEREAS, the City owns or controls land, buildings and other structures (indi- vidually and collectively the "Premises"); and WHEREAS, the Company desires to obtain permission to use certain portions of the Premises described below for the installation and operation thereon of wireless communications Equipment (defined below); NOW THEREFORE, it is mutually agreed as follows: I. PREMISES Subject to the terms and conditions set forth herein, the City hereby grants to the Com- pany the right to locate Equipment on the property commonly referred to as Fire Station No. 4 at 599 South McLean Boulevard, Elgin, Illinois and which shall together be de- picted upon the map attached hereto as Exhibit A, and described with appropriate Technical Data Sheets attached hereto as Exhibit B and with drawings showing specific details of Equipment erected at the Facility attached hereto as Exhibit C; the said Equipment to be located upon the property legally described as follows: That part of Sections 22, 23, 26 and 27, Township 41 North, Range 8 East of the Third Principal Meridian, described as follows: Beginning at the Northwest corner of the Northeast quarter of the Southeast quarter of Section 22, thence Southerly along the West line of said Section 22 for a distance of 1038.80 feet to a point; thence Westerly along a line forming an angle of 88 degrees 11' to the right of a prolongation of the last described course for a distance of 1843.60 feet to the center line of McLean Boulevard (State Aid Route 18); thence Southwesterly along said center line, being a curve to the left for a distance of 574.65 feet to a point; thence continuing in a Southwesterly direc- tion along said center line, being a straight line and tangent to the last described point, for a distance of 404.0 feet to an angle in said center line; thence Southwesterly along said center line a distance of 367.51 feet; thence Easterly along a line parallel with the South line of Section 22 for a distance of 1038.8 feet; thence Southerly along a line that is perpendicular to the North line of the Northwest quarter of Section 27 and the South line of the Southwest quarter of Section 22 for a distance of 1620 feet more or less to the South line of the North half of the Northeast quarter of said Section 27; thence East- erly along said South Line of the North half of the Northeast quarter of Section 27 for a distance of 2293.9 feet to the East line of said Northeast quarter of Section 27; thence Northerly along said East line of the Northeast quarter of Section 27 for a distance of 348.2 feet; thence Easterly along a line that forms an angle of 90 degrees 12' to the right of a prolongation of the last described course, said line also being the Southerly property line of the Elgin Mental Health Center, for a distance of 1900 feet more or less; thence Northerly along a line parallel to and 740 feet West of the East line of the North- west quarter of Section 26 of the Southwest quarter of Section 23 for a distance of 1800 feet more or less; thence Easterly along a line parallel with the South line of the South- west quarter of Section 23, for a distance of 740 feet to the East line of the Southwest quarter of Section 23; thence Northerly along the East line of said Southwest quarter of Section 23 for a distance of 1772 feet more or less to the Southerly right-of-way line of • the U.S. Route 20 Bypass (Federal Aid Route 6); thence Northwesterly along the Southerly right-of-way line of the U.S. Route 20 Bypass for a distance of 2643 feet more or less to the West line of Section 23; thence continuing in a Northwesterly direction along the Southerly right-of-way line of said U.S. Route 20 Bypass for a distance of 1329.34 feet to the West line of the Southeast quarter of the Northeast quarter of Sec- tion 22; thence South along said West line for a distance of 113.44 feet to the place of beginning. Being situated in Elgin Township, Kane County, Illinois, and containing 407.44 acres more or less (property commonly known as 599 South McLean Boule- vard). Such property and Equipment shall be referred to in this Agreement as the "Premises." This Agreement is nonexclusive and does not preclude the City from granting a similar lease, right, license, franchise, etc., to other carriers or other persons for telecommuni- cationsor anyother purpose.o e pu pose. II. USE/PURPOSE The Premises may be used only for the following use and purpose: Wireless communi- cation transmission and receiving equipment under FCC License for wireless telecom- munication services. III. SITE AGREEMENT CONTENTS This Site Agreement (Agreement) consists of these Special Terms. and Conditions as well as the General Terms and Conditions and all Exhibits and Addenda, if any, hereto attached. In the event of a conflict between the terms of the Special Terms and Condi- tions with the General Terms and Conditions, the Special Terms and Conditions shall prevail. This Agreement is intended to be the legally operative document between the City and the Company for the use of the Premises for the purpose stated herein and may not be modified except by written agreement of the parties. This Agreement super- sedes all other understandings or agreements, written or oral, between the parties relat- ing to the subject matter of this Agreement. IV. TERM The initial term of this Agreement is five (5) years ("Initial Term") and shall commence on the earlier of the date Tenant commences construction of its Equipment or May 20, 2005 ("Commencement Date") and terminates on the fifth anniversary of the Commencement Date, unless it is terminated earlier pursuant to the provisions hereof. At its option, the Company may renew the Agreement for three (3), five (5)-year periods (each a "Renewal Term") provided all terms of this Agreement are met. This Agreement shall automatically renew for each successive Renewal Term unless Tenant notifies Landlord, in writing, of Tenant's intention not to renew this Lease, at least sixty (60) lord, in writing, of Tenant's intention not to renew this Lease, at least sixty (60) days prior to the expiration of the Initial Term or any Renewal Term. V. RENT/CONSIDERATION A. Initial Period. In consideration of this Agreement, the Company shall pay to the City as Base Rent the following annual sum: Eighteen Thousand Dollars ($18,000.00) for the first year of the Agreement. Base Rent here under shall be adjusted annually, on the anniversary of the Commencement Date, and on each anniversary thereafter, to reflect an increase of four percent (4%) over the preceding year. B. Option Periods. Intentionally Omitted. C. Form and Timing of Payment. Base Rent shall be paid in advance, on or before the first day of each month. VI. INSURANCE AND LIABILITIES The Company, at no expense to the City, shall secure and maintain during the full term of this Agreement, one or more policies of general comprehensive liability insurance that fully protect the City from any and all claims and risks in connection with the Company's occupation of, or activities upon, the Premises, under which policies the aggregate amounts of coverage shall be provided per the attached General Terms and Conditions. Evidence, to the reasonable satisfaction of the City, of the Company's maintenance of insurance as required by this Agreement shall be submitted to the City Manager, or des- ignee, prior to the initial occupancy of any portion of the Premises, and thereafter, within a reasonable time after the Company's receipt of a request for such evidence, which time, in no event, shall exceed four (4) City business days. Notwithstanding any provision herein to the contrary, the failure of the Company to comply with the requirements of this Agreement regarding insurance shall subject this Agreement to termination consistent with the notice provisions of the General Terms and Conditions of this Agreement. VII. TERMINATION This Agreement may be terminated by either party subject to the notice and process provisions specified in the General Terms and Conditions. VIII. EFFECTUATION OF AGREEMENT In order to be effective, this Agreement must be (1) signed by an authorized representa- tive of the Company and returned to the City Manager at the address set forth below, accompanied by any required policy of insurance, and (2) signed by the City Manager. IN WITNESS WHEREOF, the parties hereto have affixed their signatures below: CITY OF ELGIN VoiceStream GSM I Operating Com- pany, LLC By: n By: CAUFEMI '\F0 IN, C y Manager Greg Cisewski, Regional VP — Engineering and Ops Attest: Witness: b''041-v4V/' -111\ Dolonna Mecum, City Clerk 1y1 m i (CL c Z//(OS Company's address for all communications: VoiceStream GSM I Operating Company, LLC D c/o T-Mobile USA, Inc. 12920 SE 38th Street Michael A. Sievertson Bellevue, WA 98006 Attn: PCS Lease Administrator With a copy to: Attn: Legal Dept. With copies to: VoiceStream GSM I Operating Company, LLC do T-Mobile USA, Inc. 8550 W. Bryn Mawr Chicago, IL 60631 Attn: Market Director and VoiceStream GSM I Operating Company, LLC do T-Mobile USA, Inc. 8550 W. Bryn Mawr Avenue Chicago, Illinois, 60631 Attn: Lease Administration Manager EXHIBIT A N Meyef St Iv k-,tn t fl ,�' ei;er ';t W m r', Mulberry Ln - ,rashbum o , i rj; ... x ? Y j 20 il..nuihSt v_ err r L O` '" an S, ti Adz MainLn ,,1._r�an _tz .,. MarrardLn-cj ' _ gOeaktSt p 9 �v/e� m �Berkle St . darn t o O Elgin y �. B o v E m - Gi3�-975C. PO Fleetwood Dr ( - 5995.McLeanBlvd. El in,IL 60120 Of 0{2‘ 40 m e V Z rn 4d Spartan Meadows Golf Course efield Circle Pebble BeaCtj t;{ te. i College Gee , , g f Aronominl:-G le Brews Circle ©1002 nnoro:oe co..ai ,he:reselvedilssion Hilts Or - is.in Or EXHIBIT B GENERAL TERMS AND CONDITIONS I. DEFINITIONS Whenever used in this Agreement with initial letters capitalized, the following terms shall have the following specified meanings, unless the context clearly requires a different meaning: City Manager. The City of Elgin's chief administrative official responsible for operating and managing a Facility or Facilities and holding the legal right to grant permission to occupy, use or modify Facilities or Premises subject to the approval of the Elgin City Council. Company. A company licensed to conduct business within the State of Illinois, provid- ing commercial mobile services, unlicensed wireless services, or common carrier wire- less exchange access services, or other wireless telecommunications services for the purposes of connecting to the public switch telephone network or to the Internet author- ized by the Federal Communications Commission. Equipment. Antenna(s), cables, wires, and all communication attachments, appliances, and other structures owned and operated by the Company or for the benefit of the Company, including utility facilities that serve the Company's Equipment. Facility or Facilities. A structure, including but not limited to, buildings, utility poles, and transmission, communication and water towers. Facility Manager. The person designated by the Elgin City Manager to manage the Fa- cility, including granting access, determining and approving its use and terms and condi- tions for such use. Hazardous Substance. Any hazardous, toxic, or dangerous waste, substance or mate- rial, including petroleum products, or any contaminant, pollutant or chemical defined or identified in any environmental regulation as posing a potential risk to human health or the environment. Indirect Costs. Overhead associated with the services provided by the City on behalf of the Company, included in the billing rate, which covers supervision, administration, ac- counting services, etc. Premises. The real property, described with a legal description in the Site Agreement, and/or any Facilities contained therein. Secured Facility. A Facility designated in this Agreement, or subsequently designated by written notice from the City during the term of this Agreement, where access is lim- ited as a matter of public safety or legal restriction, which requires that special access conditions be established and enforced. Senior Priority Rights. Rights bestowed based on date authorized to attach Equipment to a Facility, such that parties without such senior priority shall have the burden to cor- rect any interference caused by their installation to those with senior priority rights, pro- vided the Equipment of the holder of the senior priority right is operating within the gov- erning technical specifications. Work. Collectively, the installation, construction, maintenance, repair, relocation and/or removal of Equipment and other work performed in connection with this Agreement on, in, to, across or from a Facility or Premises. II. SPECIFIC AGREEMENTS A. RELATIONSHIP TO SITE AGREEMENT. These General Terms and Conditions, with amendments as agreed to by the parties, are an attachment to and a part of the Wireless Communication Equipment Site Agreement by and between the City of Elgin and Voicestream GSM I Operating Company, LLC (Agreement). The Special Terms and Conditions contain requirements and agreements particular to the use of the Premises and shall specify at minimum the following, including contact names and addresses where appropriate: • Company and Project Manager • Site map and drawings specifying Equipment locations and installation details, including Technical Data Sheets • When applicable, facilities to be used; Facility Owners; and the Facility Man- ager(s) • Project schedule for installations • Changes or addenda to the General Terms and Conditions of this Agreement • Bond requirements for installation instructions, when applicable • Identification of other telecommunication services with Senior Priority Rights or approved for coincident installation, when applicable B. GENERAL PLANNING, ENGINEERING AND DESIGN CONSIDERATIONS 1. Co-location With Other Telecommunications Service Providers. The Company acknowledges that the use of City properties and Facilities is explicitly authorized under a policy to encourage co-location of equipment of multiple providers. The Company agrees to coordinate the installation of its Equipment with other telecommunications providers seeking installation. The Company shall not be granted Senior Priority Rights with respect to other telecommunication providers identified in this Agreement as previ- ous or concurrent attachers. The Company shall be granted Senior Priority Rights with respect to other telecommunications providers who are approved for installation after the execution of this Agreement. The Company shall operate its wireless communica- tions facilities and services in a manner that will not cause substantial interference to the Facility or to any other third party with Senior Priority Rights to the Company. 2. Preparation of Detailed Engineering Design. The Company shall prepare engi- neering plans and specifications in consultation with and for the approval of the Facility Owner(s) to complete design engineering for use of Facilities. The Facility Owner will make a good faith effort to review and approve, deny, or request revisions to the plans and specifications in a timely manner not to exceed thirty (30) days. 3. Installation of Equipment. The Company shall be responsible to ensure compliance with all requirements of the Facility Manager regarding installation of Equipment. 4. Complete Acceptance. The City shall accept installation of the Company Equipment by issuing a letter to the Company stating that the Work has been completed in accor- dance with approved specifications and that all punch-list items have been resolved to the satisfaction of the Company and Facility Manager. 5. Establish Maintenance Plan. The Company shall have a maintenance plan for the Equipment, documenting procedures necessary to meet the requirements of this Agreement. C. ACKNOWLEDGMENT AND ACCEPTANCE OF RISKS 1. Location on City Premises. In choosing to locate Equipment on City Premises, the Company acknowledges and accepts all risks, including but not limited to: • Possibility of fires that may damage the Equipment • Risks associated with having Equipment co-located with such Facilities and the Equipment of other telecommunications providers • Ground movement • Loss of line of sight path, including where caused by City action • City change in the use of the Premises The Company explicitly acknowledges that these risks include bearing all costs associ- ated with such risks, except such costs caused by the gross negligence or willful mis- conduct of the City, its agents, contractors or employees, including but not limited to provision of alternate communication paths, loss of Company business and restoration of its Equipment and/or systems if they are damaged. The Company may terminate this Agreement pursuant to Section II.E.6. of this Agree- ment if any of the risks listed in this clause occur, cause material interference to the Company's operations on the Premises and the Company's operations cannot be re- • stored to their prior condition within sixty (60) days of the occurrence or if the Premises, Facilities or the Equipment are, or become unacceptable under Company's design or engineering specifications for its Equipment or the communications system to which the Antenna Facilities belong. The Company will not be liable for any rent during the time the Facility is rendered unusable, except when caused by action of the Company or fail- ure of the Company to perform its obligations under this Agreement. 2. Damage or Destruction. In the event that the Premises and/or Facilities (a) are damaged by fire, earthquake, act of war, or other extraordinary casualty to such an ex- tent as to render them unusable in whole or in substantial part; or (b) are otherwise de- stroyed, the City shall not be obligated to rebuild the Premises and/or Facilities or to compensate the Company for any loss of income under this Agreement. The City shall not be obligated to restore the functionality of the Premises and/or Facilities in the event of loss, damage, or destruction. The decision of the City to restore the Facility shall be based on City need for the Facility. The Company will not be liable for any loss, dam- age, or destruction of the Premises and/or Facilities, except loss, damage, or destruc- tion caused by action of the Company, or failure of the Company to perform its obliga- tions under this Agreement. The Company will not be liable for any rent during the time the Facility is rendered unusable, except when caused by action of the Company or fail- ure of the Company to perform its obligations under this Agreement. The Company may terminate the Agreement pursuant to Section II.E.6. of this Agreement if the Company's operations are materially interfered with due to the occurrence of (a) or (b) of this sub- paragraph and the Company's operations cannot be restored to their prior condition within sixty (60) days of the occurrence. 3. Acceptance of Premises and Facilities. The Premises and Facilities have been in- spected by both parties and are accepted by Company in their existing condition as of the Commencement Date of this Agreement without reservation except for latent de- fects or faulty construction of the Premises and Facilities not discoverable by inspection at the time of taking possession. D. PAYMENT TO FACILITY OWNERS 1. Facility Use Payment. Rental fees and the commencement date for the fees are stated in the Special Terms and Conditions of the Site Agreement. 2. Taxes. Company agrees to pay all current and future taxes, which are directly appli- cable to Company's uses under this Agreement. 3. Reimbursement. Company shall reimburse City, for up to Two Thousand Five Hun- dred and no/100 dollars ($2,500.00) during the term of this Agreement and within thirty (30) days after receipt of invoice, for all amounts paid and costs incurred by City at Company's expense: a. For Performance of Work. The Company shall reimburse City for all costs in- curred by the Facility Manager in the performance of Work necessary for the in- stallation and operation of the Equipment. In addition to reimbursement for direct costs of labor and materials incurred in the performance of Work necessary for the installation and operation of the Equipment, the City shall be eligible to be re- imbursed by the Company for Indirect Costs that may be included in the billing rate. Examples of Work for which the City will be reimbursed by the Company in- clude the relocation of City equipment or work in a high-security or high-risk area, such as on electrical transmission towers. b. For Relocation. Intentionally Omitted. c. On-Call Staff. The Company shall reimburse City for all on-call staff required for access to Secured Facilities at a rate of $31.25 per hour. d. Utilities and Other Services. Unless otherwise provided in the Special Terms and Conditions of this Agreement, the Company shall provide, or shall otherwise pay, before delinquency, pay the periodic charges for all utilities attributable to Company's use and shall also pay all charges for utilities provided exclusively for the Company's requirements and for utility installations and modifications thereto occasioned by the Company's requirements. The Company shall not be entitled to an offset, reduction or return of rental as the result of any interruption or failure of said services, unless said interruption or failure is due to City's gross negligence. 4. Payment. All amounts due to the Facility Owner under this Agreement shall be paid by the Company within thirty (30) days of the date of the invoice from the Facility Owner. The Facility Owner may elect to assess an interest fee of 0.033% for each day payment is late, and may consider the Company in default if any amount is not paid to the Facility Owner by the due date. 5. Rental Income. The Company may sublease the Premises, upon written notice to the City and contingent on any sublessee obtaining a separate ground lease from the City. E. TERM AND TERMINATION 1. Expiration of the Agreement. This Agreement shall expire in accordance with the terms, including any Renewal Terms, established in the Special Terms and Conditions of this Agreement. 2. Default. With notice as set forth below, and without recourse by the Company, the City may terminate this Agreement if any of the following occurs: a. The Company, after notification that its operations are interfering with the op- erations of the City at the Facility, fails to cure the operational interference within thirty (30) days. b. More than twice during any calendar year, the Company enters restricted ar- eas of the Premises without proper notification to the City and/or without the re- quired City observer present. c. The Company fails to pay rent or reimburse the City for expenses as required by the General Terms and Conditions. d. The Company fails to maintain the required insurance coverages. e. The Company fails to perform required Work within the time specified, or any authorized extension thereof. f. The Company fails to satisfactorily perform Work in conformance with this Agreement and/or to the reasonable satisfaction of the Facility Manager. In the event the City intends to terminate this Agreement for any of reasons (a) - (f) above, the City shall provide a written notice to cure, identifying the nature of the al- leged basis for termination with reasonable specificity, and advising the Company of the City's intent to terminate this Agreement. All further actions shall conform to the following procedures: The Company shall cure any default, within ten (10) business days after receipt of such notice, if the breach is a failure to pay rent, or failure to maintain required insurance. For all other breaches of this Agreement, Company shall, within thirty (30) days after receipt of such notice or such longer period of time as the City may specify in such notice, either cure such alleged failure or, in a written re- sponse to the City, present facts and arguments in refutation or excuse of such alleged failure or state that such alleged failure will be cured and set forth the method and time schedule for accomplishing such cure. The City shall determine (a) whether a failure to comply with a material provision has occurred; (b) whether such failure is excusable; (c) whether such failure has been cured or will be cured by the Company; and (d) whether any proposed cure is reasonable. The Company shall make available to the City, if requested, any records, documents or other information that is not privileged and/or proprietary in nature and that the City reasonably deems necessary to make the determina- tion. If the City determines that a failure to comply with a material provision has oc- curred and that such failure is not excusable and has not been or will not be cured by the Company in a manner and in accordance with a schedule reasona- bly satisfactory to the City, the City may terminate the Agreement. 3. Removal of Equipment. Upon termination of this Agreement due to expiration or de- fault, the Company shall promptly remove all Equipment from the Facilities and surren- der the Premises. If the Company shall fail to promptly remove the Equipment upon ex- piration of the term of this Agreement, City may, after sixty (60) days' advance notice to Company of its intent to do so, remove and dispose of the Equipment at Company's ex- pense. Company shall receive credit for unused portions of the Facility rent, less any City cost to remove and dispose of Equipment, if the termination is effective before the end of the billing period. 4. Termination Due to City Re-Use of Premises. After the first Renewal Term, the City may terminate this Agreement to accommodate the City's need to utilize the Prem- ises in a manner inconsistent with the continued use of the Facility by the Company, or to relocate, replace or remove the existing Equipment, consistent with a capital project approved by the Elgin City Council. The City shall review proposals from the Company for a mutually acceptable location on the Premises or a nearby site under control of the City, to which the Company may relocate its Equipment at its own expense. The City shall give notice to the Company under this provision with a 180-day period to remove the Equipment from the Premises from the date that notice of the intent to terminate was given, unless due to a public safety emergency, wherein the Company shall comply within such shorter time as specified by the City. 5. Restoration of Sites. Where this Agreement is for the use of unimproved Premises, the Company shall restore, at its own expense, the Premises to its previous state, rea- sonable wear and tear excepted, when directed to do so by the City, including the re- moval of any structures and Equipment and the restoration of comparable landscape features. At its option, the Company may offer to sell part or all of its structures or Equipment to the City. At its sole discretion, the City may choose to accept or reject the offer. 6. Termination Due to Damage, Destruction or Material Interference. The Company may terminate this Agreement upon the occurrence of the conditions detailed in Section II.C.1. or Section II.C.2., by giving sixty (60) days notice to the City as required under Section IV. J. Notices. F. MODIFICATIONS TO FACILITIES At the Company's request, the Facility Manager may make modifications to Facilities to facilitate building access for the installation of Equipment. Any requests by the Com- pany for such modifications shall be made to the Facility Manager. All costs for such modifications shall be paid by the Company. All modifications by Company to Facilities shall be subject to the review and approval by the Facility Manager during design and construction., Any unauthorized modifications must be corrected at the expense of the Company. The Company may be required to remove such modification and restore the Facility to its previous condition or as ap- proved by Facility Manager. In the event the City performs the restoration work, the Company shall reimburse the City for the actual costs associated with the restoration. G. REQUIREMENTS FOR INSTALLATION 1 . Installations are to be made only as approved by Facility Manager. Attachments and Equipment shall conform to Technical Data Sheets attached to this Agreement. 2. Installation of Equipment shall be in accordance with requirements of the City of El- • gin's Building Code, Mechanical Code, Electrical Code and all other applicable codes as now in force and as revised or changed in the future. 3. Installation of Equipment made by Company to City Facilities under this Agreement shall not disturb or conflict with the equipment of the City. Moving, rearranging, or ad- justment of City Facilities to provide space to accommodate the Equipment shall be done at the expense of Company, and, at the City's option, by the City. 4. In the event radio interference occurs, all users of the site are required to participate in solving the problem by providing technical personnel and equipment to locate the source of the specific problem. 5. The City hereby reserves a right of access to inspect the areas occupied by the Company. H. MODIFICATIONS OF EQUIPMENT Equipment shall not be changed or added without submitting new Technical Data Sheets and without the written approval of the Facility Manager. Replacement of like parts during maintenance and repair is acceptable without specific approval, provided that the replacement does not materially change the visual appearance of the Equip- ment. All provisions in this Section are subject to any and all conditions as required under the Special Terms and Conditions of this Agreement. I. PERFORMANCE OF WORK 1. Company shall perform the Work in a workmanlike and skillful manner and comply in full with applicable provisions of the Elgin Municipal Code. Company shall ensure that the Work and the Equipment are in all respects (a) safe, (b) free from all faults and de- fects in workmanship, material, and design, and (c) in conformance with the require- ments of this Agreement. 2. Company shall promptly and satisfactorily correct or replace any work or Equipment found to be defective or not in conformity with the requirements of this Agreement. If Company fails or refuses to perform any Work required by this Agreement or to make any such corrections or replacements, City may perform such Work and make such cor- rections and replacements at Company's expense. 3. Company shall, at all times, keep its work areas cleared of rubbish, refuse and other debris and in a neat, clean and safe condition. Upon completion of any portion of any of the Work, Company shall promptly remove all rubbish, refuse and other debris and all of its equipment and surplus materials. If Company fails to do so, City may perform such work at Company's expense. J. ACCESS AND MAINTENANCE 1. Maintenance. Company shall maintain all Equipment in good and safe condition and state of repair. 2. Permission to Enter. Access to Facilities shall be allowed only after the Facility Manager has been notified in accordance with subparagraph 3 of this subsection, be- low. 3. Requests for Access. The Company shall have twenty-four (24) hour, seven (7) day a week access to the Premises and City Facility. Company shall notify the Facility Manager in person or by telephone before access to any City Facility is desired. 4. Secured Facilities. Where Equipment is located on or in Facilities identified as Se- cured Facilities in this Agreement, Company shall be accompanied by City staff, at Company expense, pursuant to the reimbursement provisions of Section II.D.4. City shall maintain a call-out system to facilitate Company access on a continuous basis for emergency maintenance and repairs. 5. Project Control. City staff shall be authorized to stop Work that is being conducted by the Company and its contractors if, after discussions with the Company if reasonably feasible, City staff determine that the Work in question would or could potentially cause hazards to workers or interference with the City Facilities, or facilities of other users on- site. 6. Priority Restoration. Restoration of City services shall be given the highest priority in the event that any of these services and the Company's telecommunication services are interrupted at the same time, unless otherwise agreed to by the City and the Com- pany at the time of restoration. 7. Hazardous Substances. The Company understands and agrees that flammable or Hazardous Substances, including but not limited to explosives, petroleum products, paint, solvents, and resins, are not allowed on the Premises without the express written permission of the Facility Manager. In the event written permission to store the preced- ing substances is granted by the Facility Manager, the Company agrees to dispose such substances in a legal manner. Prior approval may be obtained for Hazardous Substances used during construction through the construction approval process. Prior approval may also be obtained for the use of petroleum products for emergency generation of electrical power during periods of outage. Prior to initiating any other process requiring the use or storage of, or gener- ating, on or adjacent to the Premises, Hazardous Substances, the Company covenants and agrees to obtain the Facility Manager's prior approval. The City may consider approving the specific use, but only after the Company demon- strates to the satisfaction of the City that Company has all necessary permits, if any, for operation and a Hazardous Substances emergency response plan. Company agrees to cooperate in any environmental audits conducted by the City's staff or independent third parties specifically related to the Company's use or storage of Hazardous Substances. Company agrees to reimburse the City for the cost of such au- dits. Company agrees to provide the City with notice of every governmental inspection of the Premises, notice of violation, and order to clean up contamination, within five (5) days after receipt thereof by the Company. Company agrees to permit the City to par- ticipate in all settlement or abatement discussions. In the event Company fails to take remedial measures, as required by any final administrative or judicial order to decrees signed by a state, federal, or local regulatory agency within ninety (90) days of such or- der or decree, the City may elect to perform such work, and Company covenants and agrees to reimburse the City for all direct costs and Indirect Costs associated with the City's work. Company and City hereby agrees to release, defend and indemnify the City other and hold the other City harmless for any suits, claims, damages, strict liabilities, and costs or liabilities associated with the removal or remediation of any Hazardous Substance (in- cluding petroleum and gasoline products) that are released onto or from the Premises, or otherwise come to be located on the Premises during the term of the Agreement, in- cluding but not limited to those that may have migrated to or from the Premises, due to the actions of the indemnifying party Company. "Cost" shall include, but not be limited to, all response or remediation costs, disposal fees, investigation costs, monitoring costs, civil or criminal penalties, attorney fees, and other litigation costs incurred in con- nection with such removal or remediation. K. RIGHTS OF PROPERTY AND EASEMENTS Nothing in the this Site Agreement, including the Special and General Terms and Condi- tions, Exhibits and/or Addenda shall be construed to convey to the Company any own- ership property rights in Facilities or Premises. Nothing in the Site Agreement, including the Special and General Terms and Conditions, Exhibits and/or Addenda shall be con- strued to compel a Facility Owner to maintain any of its Facilities for a period longer than is necessary for its own service requirements. This Agreement shall not be con- strued as requiring the City to obtain any easement for the benefit of the Company. The Company may request and obtain, at the discretion of the City, easements for access and utilities to, from, and across the Premises. All Equipment purchased and installed by the Company shall remain the property of the Company, unless otherwise agreed to by the Parties in an amendment hereto. III. COMPANY AND CONTRACTORS REQUIREMENTS A. CONTRACTS The Company is responsible for ensuring that the applicable terms and conditions of the Site this Agreement, General Terms and Conditions, Exhibits and Addenda are included in agreements with contractors. The Company shall be held liable for any negligence • caused by its contractors' performance or failure to perform the work under the Site this Agreement or any contracts with the Company. B. APPROVALS 1. All contractors hired by the Company to work within or on the Premises shall be sub- ject to approval by Facility Manager which approval shall not be unreasonably withheld or delayed. In all agreements with contractors, the Company may require such contrac- tors to attend a pre-construction meeting with the appropriate authority to review instal- lation requirements and Work restrictions prior to any Work being performed in or on the Premises. The contractor's agreement shall state that the Facility Owner has authority to stop Work as specified in Section II.J. of this Agreement and may require that inade- quate Work be corrected after discussion with Company representatives. 2. Where identified in the Site this Agreement, certain Facilities require, due to the na- ture of the facility, that all Work be completed by the City at Company expense pursuant to the reimbursement provisions of Section II.D.4. C. RELEASE, INDEMNITY AND HOLD HARMLESS 1. Company releases and shall defend, indemnify and hold harmless City, its succes- sors and assigns, and the respective directors, officers, employees and agents of City and its successors and assigns (collectively referred to as the "Indemnitees") from any and all claims, losses, costs, liabilities, damages and expenses (including, but not lim- ited to, reasonable attorneys' fees) arising out of or in connection with the Equipment or installation of any Equipment to any structure, the performance of any Work, the opera- tion of any Equipment, or the Company's system, or the acts or omissions of Company or any of its suppliers or contractors of any tier, the respective successors and assigns of Company, or anyone acting on Company's behalf in connection with said installation of Equipment, performance of Work, or operation of Equipment or Company's system. 2. Such indemnity, protection and hold harmless shall include any demand, claim, suit or judgment for damages to property or injury to or death of persons, including officers, agents, and employees of either party hereto including payment made under or in con- nection with any Worker's Compensation Law or under any plan for employees' disabil- ity and death benefits, which may arise out of or be caused or contributed to by the erection, maintenance, presence, use or removal of Company's Equipment or installa- tions of Equipment including any claims or demands of customers of the Company with respect thereto. 3. City shall not be liable to the Company or to the Company's customers, and the Company hereby indemnifies, protects and saves harmless City against any and all such claims or demands, suit or judgment for loss, liability, damages and expense by the Company's customers, or for any interruption to the service of the Company, or for interference with the operation of the Equipment. 4. To the fullest extent permitted by applicable law, the foregoing release, indemnity and hold harmless provisions shall apply to and for the benefit of the Indemnitees. 5. City is willing to permit installations of the Equipment to the Facilities for the fees de- scribed in II.E. of this Agreement only in consideration of and in reliance upon such re- lease, indemnity and hold harmless. D. WORKER'S COMPENSATION, INSURANCE AND BOND 1. Company shall ensure that, with respect to all persons performing the Work, Com- pany or its suppliers or contractors maintain in effect at all times during the term of this Agreement coverage or insurance in accordance with the applicable laws relating to worker's compensation and employer's liability (including, but not limited to, laws of the state in which any such person was hired), regardless of whether such coverage or in- surance is mandatory or merely elective under the law. Company shall furnish to the Facility Manager such assurance and evidence of such coverage or insurance as the City may request. 2. Company shall obtain, and maintain continuously for the term of this Agreement, at its own expense, occurrence form Commercial General Liability insurance with en- dorsements and/or other insurance to indemnify for the activities and services of this Agreement. Minimum limit of coverage shall be $1 ,000,000 each occurrence and $2,000,000 in the aggregate. Company shall also obtain, and maintain continuously for the term of this Agreement, at its own expense, business automobile liability coverage for owned, non-owned and hired vehicles. Minimum limit coverage for bodily injury and property damage shall be $1,000,000 per person and $1 ,000,000 per occurrence. The insurance carrier issuing the policy must have an A.M. Best rating of at least A-:VII and be legally admitted and licensed to do business in the State of Illinois. 3. Such insurance shall be endorsed to include the City of Elgin, its directors, officers, employees, and agents and joint users as additional insured, and shall not be reduced or canceled without forty-five (45) days prior written notice to the City. 4. Such insurance shall include a "cross liability," "severability of interests," or "separa- tion of insureds" clause indicating essentially that "except with respect to the limits of insurance, and any rights or duties specifically assigned in this coverage part to the first named insured, this insurance applies as if each named insured were the only named insured, and separately to each insured against whom the claim is made or suit is brought." 5. Prior to commencement of performance of any of the Work, Company shall provide the FacilityManager with a duplicate (photocopyor facsimile acceptable) of the required 9 p P ) q insurance policy(ies) with its endorsements as evidence of coverage. The company or companies issuing such insurance and the policies issued shall be subject to approval by the City. 6. Company shall promptly advise the City of all claims relating to damage to property or injury to or death of persons arising or alleged to have arisen in any manner by, or di- rectly or indirectly associated with, the erection, maintenance, presence, use or removal of Company's Equipment. Copies of all accident or other reports made to any insurer by Company shall be furnished to the Facility Manager. 7. Company shall also furnish the Facility Manager with such additional assurance and evidence of such insurance (such as copies of all insurance policies) as the City may from time to time request. Within thirty (30) days after any notice of termination, cancel- lation, expiration or alteration in any policy of insurance required under this Agreement, Company shall deliver to the Facility Manager a duplicate of the replacement policy with its endorsements naming the City as an additional insured. 8. Company shall ensure that any policies of insurance that Company or any of its sup- pliers or contractors of any tier carry as insurance against property damage or against liability for personal injury (including death) shall include a provision therein providing a waiver of the insurer's right to subrogation against the Indemnitees. To the extent per- mitted by its insurance policies, the City hereby waives all rights of subrogation against Company, its successors and assigns, and the respective directors, officers, employees and agents of Company and its successors and assigns. 9. The requirements of this Agreement as to insurance and acceptability to the City of insurers and insurance to be maintained by Company are not intended to and shall not in any manner limit or qualify the liabilities and obligations of or assumed by Company under this Agreement. 10. Intentionally Omitted. In addition, Company shall furnish to the Facility Manager, at such times and in such forms as the City may in writing request, surety bonds with per- formance, payment and maintenance clauses payable to the City. E. PERMITS Company shall obtain and comply (and shall ensure that the Equipment, the Work, and all of Company's suppliers and contractors of any tier comply) with all applicable permits including authorizations as required under the City's Zoning Ordinance (Elgin Municipal Code, Chapter 19) if applicable, licenses, franchises, rights-of-way, easements, and other rights required to perform the Work and operate the Equipment and the Com- pany's system in accordance with this Agreement. Company shall furnish to the Facility Manager such evidence thereof (such as certified copies of permits, licenses, fran- chises, rights-of-way, and easements) as City may request. F. COMPLIANCE WITH LAWS AND REQUIREMENTS In the performance of the Work under this Agreement, and the continued use of the Company's Equipment on City Premises, the Company shall comply (and shall ensure it that the Equipment, the Work, and all of Company's suppliers and contractors of any tier comply) with all applicable: 1. Laws, ordinances, rules, regulations, orders, licenses, permits, and other require- ments, now or hereafter in effect, of any governmental authority; 2. Industry standards and codes; and 3. City construction guidelines, specifications, rules, and regulations which apply to Company's Work and will be provided by City to Company on request. 4. Federal requirements regarding radio-frequency emissions and interference with other electronic or telecommunications equipment. 5. Senior priority rights held by other telecommunications entities to be protected from interference. 6. Company shall furnish such documents as may be required to effect or evidence compliance. All laws, regulations, and orders required to be incorporated in agreements of this character are incorporated herein by this reference. G. NONDISCRIMINATION During the performance of Work, the Company, for itself, its assignees and successors in interest, agrees as follows: 1 . In all hiring or employment made possible or resulting from this Agreement, there shall be no discrimination against any employee or applicant for employment because of sex, age, race, color, creed, national origin, marital status, or the presence of any sensory, mental or physical handicap, unless based upon a bona fide occupational qualification, and this requirement shall apply to, but not limited to, the following: em- ployment advertising, layoff or termination, rates of pay or other forms of compensation and selection for training, including apprenticeship. 2. No person shall be denied or subjected to discrimination in receipt of the benefit of any services or activities made possible by or resulting from this Agreement on grounds of sex, race, color, creed, national origin, age except minimum age and retirement pro- visions, marital status or the presence of any sensory, mental or physical handicap. 3. Any violation of this provision shall be considered a violation of a material provision of this Agreement and shall be grounds for cancellation, termination or suspension, in whole or in part, of the Agreement by the City. H. SEXUAL HARASSMENT As a condition of this contract, the Company shall have a written sexual harassment policy that includes, at a minimum, the following information: 1. The illegality of sexual harassment; 2. The definition of sexual harassment under state law; 3. A description of sexual harassment, utilizing examples; 4. The vendor's internal complaint process including penalties; 5. The legal recourse, investigative and complaint process available through the Illinois Human Rights Commission; 6. Directions on how to contact the department and commission; 7. Protection against retaliation as provided to the Department of Human Rights upon request (P.A.87-1257). IV. ADDITIONAL CONDITIONS AND PROVISIONS A. NON WAIVER The failure of either party to insist upon or enforce strict performance of any of the pro- visions of this Agreement or to exercise any rights under this Agreement shall not be construed as a waiver or relinquishment to any extent of its right to assert or rely upon any such provisions or rights in that or any other instance; rather, the same shall be and remain in full force and effect. B. ASSIGNMENT; SUCCESSORS AND ASSIGNS Company may assign, transfer, sub-lease or otherwise dispose of any of the privileges granted under this Agreement to a business entity which meets the following criteria: (i) licensed by the Federal Communications Commission to operate a wireless communi- cations business; and (ii) (1) is a parent, subsidiary, affiliate or successor of the Com- pany; or (2) controls or is controlled by or under common control with the Company; or (3) is merged or consolidated with the Company; or (4) purchases a majority or control- ling interest in the ownership or assets of the Company; (5) purchases substantially all of the assets of the Company; or (6) purchases substantially all of the assets of the Company in the Metropolitan Trading Area in which the Premises are located. Upon notification to the City by the Company of such action, together with a statement by the receiver of the privileges that it will comply with the conditions of the Site Agreement, the Company shall be relieved of all future performance, liabilities and obligations under the Agreement. The Company may not otherwise assign transfer, sub-lease or other- wise dispose of any of the privileges granted under this Agreement without the written consent of City, which shall not be unreasonably withheld or delayed. C. SURVIVAL The obligations imposed on Company and all provisions of this Agreement which may reasonably be interpreted or construed as surviving the completion, termination or can- cellation of this Agreement, shall survive the completion, termination or cancellation of this Agreement. D. ENTIRE AGREEMENT The entire Site Agreement between the City and the Company shall consist of the Spe- cial Terms and Conditions, the General Terms and Conditions contained herein which shall be affixed to each Site Agreement, and all Exhibits and/or Addenda issued concur- rent with or subsequent to the execution of this Agreement, and any amendments to same. E. APPLICABLE LAW This Agreement shall in all respects be interpreted, construed and enforced in accor- dance with the laws of the State of Illinois and venue for any legal proceedings shall conducted in the Circuit Court for the Sixteenth Judicial Circuit, Kane County, Illinois. F. SEVERABILITY In the event any section, sentence, clause, or phrase of this Agreement is adjudicated to be invalid or illegal by a court of last resort and of competent jurisdiction, the remain- der of this Agreement shall be unaffected by such adjudication and all other provisions shall remain in full force and effect as though the section, clause, or phrase so adjudi- cated to be invalid had not been included herein. The Parties hereto agree to then ne- gotiate in good faith the replacement section, sentence, clause, or phrase which is legal and most closely represents the original intent of the Parties. G. RIGHTS CUMULATIVE The rights and remedies of the parties provided for under this Agreement are in addition to any other rights and remedies provided by law. The failure to exercise on any occa- sion any right shall not operate to forfeit such right on another occasion. The use of one remedy shall not exclude or waive the right to use another. H. CONTRACTUAL RELATIONSHIP — NO CO-PARTNERSHIP OR AGENCY This Agreement does not constitute the Company as the agent or legal representative of a Facility Owner for any purpose whatsoever. The Company is not granted any ex- press or implied right or authority to assume or create any obligation or responsibility on behalf of or in the name of the Facility Owner or to bind the Facility Owner in any man- ner or thing whatsoever. In no event shall the City be construed or held to have become in any way or for any purpose a partner, associate, or joint venture of the Company or any party associated with the Company in the conduct of the Company's business or otherwise. I. HEADINGS The titles of sections are for convenience only and do not define or limit the contents. J. NOTICES All notices and other materials to be delivered hereunder, shall be in writing and shall be delivered or mailed to addresses as identified in the Special Terms and Conditions of this Agreement. K. NON-EXCLUSIVITY This is a non-exclusive arrangement. L. MODIFICATION OR AMENDMENT No modification to or amendment of the provisions of this Agreement shall be effective unless in writing and signed by authorized representatives of the City and the Company. The City and the Company expressly reserve the right to modify any Agreement, from time to time, by mutual agreement. CITY OF ELGIN VoiceStream GSM I Operating Com- pany, LLC By: _ «,.� � �.. By: OEUFEMI F ARIN, Ci y Manager Greg Cisewski, Regional VP — Engineering and Ops Attest: Witness: Dolonna Mecum, City Clerk 2 j ) 1 D c .�4 v,,n r�Cal K t� as to form Michael A. Sievertson 1, ?�" ' 1 t rw Pi' 0,tx ?s y„a 'f'1oj F A -tYe,d� �-.' as bft..;f 0- ,1-4,1}�v W.l. {ip. X ` z F '�, a q 'at,. 4 4,F F,*1 y .rt„' .. S 1 E �.'R. a r 3Y ,,ta .** i cal? . . axe dx'e _ __e GSWI S12OøO0ubo0T m ka � r r 5t^ -- p+' � Nortel Networks offers wireless operators its next-generation GSM BTS(Base Transceiver Station),the 512000 s •4 /�t -""T ( � � I r< tk Outdoor which is based on aintegrated RF anddesignavailable in Flexible dual and mono band t.-_- g� li n ma battery highly digital ' � tia ,,-i - -� `F aecu configurations.The S12000 Outdoor maximizes cell site investments,offering wireless operators a highly �'"•t• t ..�' `_ ) I I 1 { 4{. ,i spectrally efficient BTS that supports AMR and GPRS/EDGE as part of the smooth evolution to next-generation , P t -.._ + �' � lam-t Fpp•r.,,,,apPN(2) GSM technologies. 1 - I —..— 1 Coen inirn:onecuom GSM BTS 512000 Outdoor technical specifications o F'pt z "' ) rS LL .c,,. a.} -switch panel Re' y 9 ___...- .. - GSM e 0/900/I800/1900 MHz Mono Band and Dual Gar d.i pp h e ,- tiNty w/o diversity - 113 da guaranteed- ( / TMA) �.r. `. t Iief - - 't• :lI/.artl�in neck or Gi3with diversity -II dt guaranteed( /o TMA) ¢•�y, l - - _ - - ;3cc Dimensions Ha WAD 1910 1350 min z 6`A min ,::. 4, - i ::.mom..+•- 7 ] _. 2 x256 1 t Weight Empty cabinet 20 kg(auoib) _ �4� t t• - ) 1( f *� Y F' _ ally equipped Okg(135 h.) a s, we i' ; . r PP��Ys� A1- - Capacity - - Standard ti TR%p dlocabinet—upt 3 radio,cablel: c mi il;I -i , tD" J 10 ii�''tf i fi;J Ta V �s 1 er i Configuration Moro band Up to 512-t2-12(3 rod o ab,net.) , , i i 1 - .. -- r:. Tri-sector ... . CH dual 9 additional radio and once C fa atmnni pnrl.-i ll - I,) ..FNePAIror'n fii __.. _—__ anloutor l band 5222 22l mno,IA and cabnetB _- - _.. ___._ T i r Amplifier output power Standard I30VI(SOS dB)GMSK/B.DSK EDGE ppc ' Optional 60W(S 0.5 dB)GMSK/45W(x0 5 dB)B-FSK Transmission coupling Duplexes 2-Wey(H2D).1-Way(HID/Hybrid Coupling,Winer Power control Static 6 steps of 2 dB ` ( r / 1 Dynamk 15 steps oft dB - „ I ! I 1 ^.F i -i r 1 •i _ _.. 7 RFmxpier Frequency hopping RF Synthesitad -__.. ._.. -.. _ -, )_ Supported vo•coders Full Rate(fRCEnhanced Fun Rat (EFR)adaptive - - ty{ y(___ - -m r Y Multi-Rate—Full Rate(AM0.FR)and Half Rate(AM a x i kr�! �1 4 - 1 i_ • I :T t0M'CO Pow.supply s Nominal and A5/2 ngN-SPI It ortrl-phase 230V(50/60H2)ACRH 4 0 won „ i Power bete-up Integrated battery backup plus optional ancillary external battery -- >' S'€> ""',`tat? - cabinet can be provisioned for up to 2 hours fora 12 radio cabinet _ RF t ,rahin.r -- Operational temperature range -10-C to a50'C/-10'Fto<RYF -�W r T^ns bullhead -_. -._ ' ;..ti[ Max He noise 63 MICA)for T'<10'C and 10 dB(A)T'a 40.0 Backhaul maximum 6E1/T1 links GSM BTS 512000 outdoor - s32In./1i50m installation configuration — — ' ---i Acronym definition ra i ea` I AC Alternating Current 11.5 q are feet 42.2 In./1070m 9 I CBCF Compact Base Common Function I COMICO Combiner Interconnections \\ .=- DACS Direct Ambient Coding System 'J -:== clt in/is5om C Duplexer '<- e-DAD EDGE T%Driver t Receiver a Frame Processor e-PA EDGE Power Amplifier ' • • _ _ EDGE Enhanced Data-rates for GSM(Global)Evolution �� 1,1' : l - F-Type Converter Supplies t 15 VDC to Low Noise Amplifier and VSWR Meter p - ;Nuance GIPS GSM Integrated Power System -Y„we•�„n `',\l1\U f o:rtat« fIlu, GMSK Gaussian Minimum Shift Keying Radio modulation used in GSM GDRS General Packet Radio Services w HePA EDGE High Power Amplifier � : - H2D 2-way hybndduplexer/combiner ""s:""' '•`•'<•• `� • _ — -' I. ---__ �' : HOD 4-cr yybnd duplexer/combiner www.nortalnetme k.none ' I I KO interconnectione I PCU' Power Control Unit M ,,,--, { - i I PCM Pulse Code Modulation ..,w, ...�.,. `•-_.- -'`e' " RECAI Remote Control Ala _. r t l - -. _.._ Rx Recdaofrequenry iver r - TMA Tower Mounted Amplifier N RTE TT%F Transmitter L F. „ t X+,, Transmitter Filter JETWORCSI + � �`� n -¢��1` C : w.'s' il-PSK BPhase Shift Keying Radio modulatonused inEDGE t4a , " ax+ d 1, f`'•,. .-ma �+ s , '4" w ,,, s, t 7" , , r x. •o-u .xr -a 'd i , ,,,,,,,, c`fi? l ,b,: x?,1.1..T.:p. — .> - :- — ��K :�'�„jr � ,4 h a ,;�� �!a.". .,' - ,� `r3-',..._. :;:.r •t� '�-�'n'... � s", z�' x' �$ � .a $,+�' �1� rya-,Vu U� � �N},.; ✓ 4.�`� `, r,".�w'"Y. ,� � ,,'»Y,„-� 'T -u,.(e"y r5 t��' g �x�e1'ti;.y.4 ��"i�`S!a'a ��,,. 'k�I r� ��� .d #crv'+li � � �a �.ri � x�na,,,.t t 'a€ ��.�E ,. ,.� � ,��a .�.-.`, ,� �'" S*1. .1,� �5:"•.:. x �ti�.0� ��`,; � _��c, � �r ..a.:;�x� ' f � 4� s„Y' �-<�Y %�A"�Y.:,� 'z�k a.�f3. .. :11'...� .y,4,,' t _ ,,... Es r gt z s k-A 1 ;,'� - v»•w r# <e� `x..m r,, ..< sib ,,, € �,;F, >:^4 ? 715W.�.,,.i �°'.r�. air tr .m�" 'sm. �6 1s ,: -� � �� i � �, �"�,` a RR65-19-XXDP ..� . DualPol® Polarization OptiRangei" ' 1850 MHz- 1990 MHz Electrical Specifications $' Azimuth Beamwidth 65° 2•75' /� t Elevation Beamwidth 4.5° Gain 18.5 dBi(16.4 dBd) -. Polarization Dual Linear Slant(±45°) i °' -. Port-to-Port Isolation >_30 dB Front-to-Back Ratio >_30 dB ,' Electrical Downtilt Options 0°,2°,4°,6° 72„ VSWR 1.35:1 Max ,. i 42„ Connectors 2;7-16 DIN (female) Power Handling 250 Watts CW / Passive Intermodulation _<-150 dBc [2x20W(+43dBm)] l/ 2,-Lightning Protection Chassis Ground RF CONNECTORS-' Mechanical Specifications 1 :4 Dimensions(L x W x D) 72 in x 8 in x 2.75 in r;vill ,` (183 cm x 20.3 cm x 7.0 cm) ,.$ 1 ,� Rated Wind Velocity 150 mph(241 km/hr) t ' c� a Equivalent Flat Plate Area 4ft2(.37 m 2) �, '� t- ;� , -•,t Front Wind Load @ 100 mph(161 kph) 115 lbs(512 N) �� � ' F Side Wind Load© 100 mph (161 kph) 40 lbs(176 N) i Weight 23 lbs(10.4 kg) SEE it ,„ • INti,AfAtIP:Y Mounting Options ; , MTG-P00-10, MTG-S02-10,MTG-DXX-20*,MTG-CXX-10*, MTG-0O2-10, MTG-TXX-10* Note: *Mode(number shown represents a series of products. See Mounting Options section for specific model number. Patterns - 27r AO• 27r 277r 2�0' 1. 2A0' 74r 700' 240• Tor T•r - Mr LP' aar ztr �i sxr z10' .,a aao• z2o• f ' .'` ( ,1. ' 'Ti 11 �' f ` 40' itr j � aar 21r r � �yJL :w \-_ °'1-00- 1407, utffi'i1�Rca r 1!r ,I m,1'�l}E tl�9�s r 1ir '' �, p � P 7�C' ' iD+1,h /ribl�,'^u r r� 150' . 30• 15?' ao• ma :`-L--''' w• 1w• - = •a 4 ' .w; ,W w ` rt- • 12°• ....5 :br tp• 6r 120' k *r 1x°• ., •='X• W�i0' ..-..1 1R - 1 10. sr sr it oo' Azimuth Elevation Elevation Elevation Elevation I 0° Downtilt 2° Downtilt 4° Downtilt 6° Downtilt I Revised 04/05/02 +1 770.582.0555 ext.5310• Fax+1 770.729.0036 I www.emswireless.com i AREA MAP PROJECT INFORMATION • ^!•�, .. • . `... _ _--ate,- .. ' • • • ■ • 1 ` . 2 T Mobile © - ,p "" SITE NUMBER: C137-975C 8550 W Bryn Mawr Ave.Ste 100 E � .7 14 NAME: N RI. Chicago,IL 60631 SITE N FIRE STATION ( _ Tel 773 444 5400 p SITE ADDRESS: 599 5 MCLEAN BLVD. e ,� �I w+? . ELGIN,IL 60120 • Fax 773-444-5521 L �. I N 0 I�' eT 21:34 31 1 ry. `F- COUNTY: G7 MI6 MMIIIIIC.h.00 ' KANE r3 Mobile .,•• 7M gift!! ti ZONING CLASSIFICATION: PERMITTED USE � y --�V 'r rel .�., , ZONING JURISDICTION: CITY OF ELGIN �' /4- BUILDING CODE: BOCA,NATIONAL BUILDING CODE, �' t1 1996 EDIT. ©J$ _m :. ,' Transcend-Nike Corporation �f�++11�, 2112 W.GALENA BLVD.STE.8-188 .z..9'JSC FJi4.' „ OWNER: CITY OF ELGIN AURORA,IL 60506 EN .0169 s6.3130 r ` ISO DEXTER COURT a +�s ,� Y'� • ELGIN,IL GO120 TEL.636888 1281 a, eu �+ FAX.630-688-1282 t s br. �� SITE NUMBER TNC PROJECT NUMBER:617 ''''''''''......„...,Tay Lake •: v �E.':".. APPLICANT: r-MOBILE USA,INC. � �• , • k' A. 8550 W.BRYN MAWR AVE. a = © 44 i C H 37-975C CHICAGO,IL6063I .om . Ikamry, inc. e Perk f4 ( _ s s ..; © . TEL.(773)444-5400 • 7 "..._� ,,;,,.+..-�-�+3a e4 s PAX (773)444-5521 CONSULTING ENGINEERS `- -� .-.Ekxgn - !arm 1 ,. . R i 406 Meadow Ridge SITE NAME T-MOBILE PROJECT MANAGER: MIKE ukVICKA VICINITY MAP $ PC5(630)461-8662 Prospect Heights,IL 60070 - FIRE STATION RL Tel.(847)670.7413 ~ a e RF ENGINEER: PAUUNO MEDINA E-Mail:kamryenp.com r ...,, "'..":`,;.••.- ,..49:( :‘ _47 , '---9'''';:k41." 4'''-'... ::'," ..mi7F, '',,- TEL.(847)877-002B G) S '`-,,! - A3LIi " '"'" �fr „'v` MATERIAL PICKUP: KEITH OWENS v v v N.'may, aI (z +E' 1 1I. TEL(847)877-5149 o 0 0 0 �` � �` y� ,'�, � SITE ADDRESS N N 4 In r �; --' , , °�,rr • 't. e ?= 599 S MCLEAN BLVD. -� t '171, ,� ELGIN, IL 60120 APPROVALS 1- „� ,. .•,,,, � L , KANE COUNTY w W CC z j j � aI z 21 st> a � Z cc g Z0 w J( w; �, REAL ESTATE DATE NETWORK DATE F CO 65 U 1ll , _,. � t' ,, ` ,i i-;�,% PROJECT TYPE o o w r N% 42.0189-88 3130 •, ; i' LL W `' -t 1�' I ZONING DATE OPERATIONS DATE O Q Z� O TT t" - (G) NEW ANTENNAS W/ (24) COAX RUNS D (0 uj ,ors y n -' �. axxxs ,g � � ON NEW 130'-0"f1 MONOPOLE WITH BTS ON U' • 7 ,�, CONSTRUCTION DATE LANDLORD DATE 0 I" , NEW CONCRETE FOUNDATION s�Rd *„..[ IJtyP„ Rd -,.-°;-'''s I, .-,'- s� wS 'Wr.., rrY,=w .. ..,-- ..-' _ RF DATE DATE DIRECTIONS (FROM T-MOBILE OFFICES;8550 W BRYN MAWR AVE.) PROJECT TEAM i co co 0 SHEET INDEX ,1.:4...A . ,�.�- 1. i : SUMMARY: 31.4 MILES(35 MINUTES) GENERAL CONSULTANT PROFESSIONAL ENGINEER STRUCTURAL ENGINEER e'�GX y e�:tt tGK X. BE YtJ 0.0 DEPART T-MOBILE OFFICES[8550 W BRYN MAWR AVE]ON W BRYN MAWR AVE(EAST)0.3 MI TRANSCEND-NIKE CORPORATION KAMRY,INC. KAMRY,INC. T I.I TITLE SHEET :�`.Q elk 1) e<, .••"..... =,try 21 12 W.GALENA BLVD.STE.8-186 406 MEADOW RIDGE IN 406 MEADOW RIDGE W """"'"'6' 4 '` ••••••'' S - .� '• 0.3 TURN LEFT(NORTH)ONTO SR-171 [N CUMBERLAND AVE]0.4 MIy�q: q 4 ,, Q •;'• ..-t 0.7 TURN OFF ONTO RAMP 0.2 MI I-90/OHARE/ROCKFORD AURORA,IL 60506 PROSPECT HEIGHTS,IL 60070-1083 PROSPECT HEIGHTS,IL 60070-1083 �4L; 881-004042 I, j . 44. 062-033842 . 0.9 MERGE ONTO I-90[KENNEDY EXPY W](WEST)0.7 MI ; • REGISTERED :�e. ••t+.• REGISTERED • 9 I.5'TOLL ROAD'STAY ON I-90[NORTHWEST TOLLWAY](WEST) TEL 630-688-1 281 TEL 847-670-7413 TEL 847-670-7413 -GNJ. I. GENERAL.NOTE5 • - .0 , R 25.9 TURN OFF ONTO RAMP 0.2 MI IL-31 FAX 630-688-1282 FAX 847-670-7434 FAX 847-670-7434 jam(', UPA p / GN.1.2... ..GENERAL.NOTES ;,>..•..; t PROFESSIONAL +' 26.1 MERGE ONTO 5R 31 [N STATE 5T](SOUTH)2.3 MI 4 'UCTU fi 'i,; t r 28.4 CONTINUE(SOUTH)ON U5-20 BUS[SR-31I 109 YDS GN I.3 GENERAL NOTES ( �,j J '' 25.5 BEAR LEFT(SOUTH-EAST)ONTO SR 31 [5 STATE 5T] 1.0 MI ELECTRICAL ENGINEER SURVEYOR GEOTECHNICAL CONSULTANT tr r' t 29.5 TURN OFF ONTO RAMP 0.1 MI U5-20/ROCKFORD KAMRY,INC. ASM CONSULTING,INC. N/A GNI.4 GENERAL NOTES jp� / .r ttf 29.7 CONTINUE(WEST)ON US-20 I.I MI 406 MEADOW RIDGE IN I I I I WOODWIND DR. rWItv t ' ' h ..30.5 BEAR RIGHT(WEST)ONTO RAMP 0.2 MI MCLEAN BLVD PROSPECT HEIGHTS,IL 60070-1083 PLANO,IL 60545-I062 `ti / •y 31.0 TURN LEFT(SOUTH)ONTO 5 MCLEAN BLVD 0.4 MI L I.I LANDSCAPE PLAN S L f 1 4 jV `~~ 31.4 TURN LEFT(EAST)ONTO SPARTAN DR.87 YDS TEL 847-670.7413 TEL(630)273-2500Y �R'� 31.4 ARRIVE CH37-975C FIRE STATION RL FAX 847-670-7434 FAX (630)273-2600 CJ..1..... ..SITE.PLAN. //�� LOLL./...kt.''.I,.lp./... i - - SITE COORDINATES ' HANDICAPPED REQUIREMENTS C2.1 ENLARGED.SITE.PLAt1....,.4;a ( 1� FIRE CH37-975CTATIO RL EXISTING UTILITIES TELEPHONE UTILITY CO. ELECTRIC UTILITY CO. C3'..1..... ..ELEV.ATiONS...s CONTRACTOR TO CONTACT INDEPENDENT SBC COMMONWEALTH EDISON CO. Q RAWLAND UNDERGROUND UTIUTY LOCATOR ON ALL 2000 W.AMERITECH CENTER.DR.STE.4C-10 1 25 5.CLARK STREET C4..I.....,.FENCE.DETAILS j LATITUDE: NORTH 42-01-08.00 NAD83 FACILITY 15 UNMANNED AND NOT FOR HUMAN SITES 48 HR5 PRIOR TO DIGGING HOFFMAN ESTATES,IL 60191 CHICAGO,IL GOGO3 599 S McLean Blvd. HABITATION;HANDICAP ACCESS REQUIREMENTS C5..1..... ..DETAILS Elgin,IL 60120 LONGITUDE: WEST -88-18.46.8 NAD83 NOT REQUIRED JUUE(800)892-0123 TEL I-800-832-6328 TEL(800)334-7GG I GROUND ELEVATION: 817.57 AMSL NGVD29 , FAX (773)509-3294 SHEET TITLE: SJ...L..... ..FOUNDATION.PLAN PLUMBING REQUIREMENTS RFI.I ANTENNA CONFIGURATION TITLE SHEET CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE PROJECT SITE AND SHALL IMMEDIATLY NOTIFY THE ENGINEER. IN WRITING OF ALL DISCREPENCIES BEFORE PROCEEDING WITH WORK FACILITY HAS NO PLUMBING E I.I UTILITY PLAN •2a01 TRANSCEND-NINE CORP.ALL NOM RESERVED E I.2 UTILITY RISER SHEET NUMBER: E2.I .,GROUNDING PLAN......................................... . T1.1 E2.2 GROUNDING DETAILS f � SITE PLAN � ; GRAVEL PAVING DETAIL ,` �gi� SCALE: I" = 50'-0" ; SCALE: NTS T . Mobile. ■ 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 59 tgTel 773-444-5400 VVV TOP COURSE Fax 773-444-5521 -zl. �" i - STABILIZATION FABRIC 111.1.4, 1 ��^Y/ 1. \ SEE PLAN \-"�� 2112 W.GALEENA BLVD SITE'&1gg[IOit AURORA,IL 60506 NEW I d-0"UTILITY EASEMENT } `-'•,, LEASE AREA TEL.630-688-1281 t i,--"-_-. FAX.630688.1282 • NEW MONOPOLE FOUNDATION;REF.TO �,, TOP COURSE:4'MIN.OF COMPACTED CA-7 COARSE AGGREGATE TNC PROJECT NUMBER:617 PROPERTY LINE TOWER MANF.DRAWINGS FOR DESIGN ? BASE COURSE:4"MIN.OF COMPACTED CA-6 COARSE AGGREGATE AND DETAILS ; 670-7434 L. GROUND PREP:MIRAFI 500 WEED CONTROL AND GROUND STABILIZATION FABRIC NEW 2'-0'W CABLE BRIDGE;HEIGHT TO ACCOMIDATE a ACCESS DRIVE kaTTlly, lnc. IXISTING TOWER PORT HOLE TOP CCURSE:3"MIN.OF COMPPCTED CA-6 COARSE AGGREGATE CONSULTING ENGINEERS BASE COURSE:6"MIN.OF COMPACTED CA-3 COARSE AGGREGATE 406 Meadow Ritlge OUTLINE OF IXISTING FOLIAGE GROUND PREP:MIRAFI 500 WEED CONTROL AND GROUND STABIUZATION FABRIC Prospect Heights,IL 60070 Tel.(847)670-7413 • r — — —' ' — — — — — — FUTURE PANSION AREA BENCHMARK/PROJECT DATUM Iiir E Ma( kemryeng.mm TY — w O BENCHMARK' _ / ( CITY OF ELGIN SURVEY POINT X0026. GPS MONUMENT(3'AWMINUM DISK •rs v e �/� /��/��/�� WITH T MCCLEAN BLVD FIRE STATIO ( ) ( E SURVEY FOR LOCATION) // '+ A 0 N v1 w _ N k4. SE ON /;' I CON/ CRETE—� 1 ' .-ti, ELEVATION: 822.3?NGVD29 c� v In DRIVEWAY :-..-::::..:::.-:::.:1..:-.1171:4-4::-::::::'"'::::::'.-:.'1'. 11j SIFT BENCHMARK:ON TOP F CURB ISLAND EAST OF FIRE STATION. t t ASPHALT DRIVEWAYl �� NEW 25'-O'X 25'-0"T-MOBILE LEASE AREA (SEE SURVEY FOR LOCATION) ,i / i t d W/BTS EQUIPMENT w 3 = CC Z DUSTING f _ P +, ELEVATION: 817.ST NGVD29 W W 7 r _ /• FERFFSOLI5E -_tee '° �> 5 W a_ 1- Lu JJ --J 1 NEW GATE:REF.SHT C4.I O LU LU 0 W D_ (f /a / /ij _ a a tr vUi A� \L - V O O m O _ LU :...:,,:,..::•:,,::-,,i',-,c,..,if:.:::::-,g7.5,•=.-e- IXISTING SORM WATER 0 a D LL O 0 j SEWERUNE;NOCHANGE `� IXISTING LEGEND NEW U) w w �Z to 0 0 ` 55 SANITARY SEWER rjr— U '`� 1( ,.- - STS STORM SEWER STD �l) o / :1e 't - N_ WATER MAIN W . � NEW 12'-OW DOUBLE SWING GATE OVERHEAD ELECTRIC 0 cal `� v Cr) �� OE Off— z o0 0 .. _� """� NEW I d17W ACCESS EASEMENT ti�� r -` .,r---'•"" ��"--" _ UE UNDERGROUND ELECTRIC - UE 86-Ittt •x,.,; --- .' TO NEW LEASE AREF4 REF 2/C I.I _ OVERHEAD TELEPHONE _ 07— T O - _i UT UNDERGROUND TELEPHONE U I �vO• y Ir _ if •062�42 ' - UTILITY POLE REGISTERED � I. jJ i i PROFESSIONAL = i / - _ _.. ,- SURFACE DRAIN �lt f = ENGINEER .. """ EXISTING BUSHES;NO CHANGE r r - 0 LIGHT STANDARD • 't;It : NN.----0',., CONTOUR LINE d� `IA \\ 0���~ O MANHOLE Q FIRE STATION RL —x�— FENCE —8—x— CH37-975C RAW LAN D CALL JUUE TOLL FREE STREET LIGHT 599 S McLean Blvd. I(800)892-0123 orour<s z4 nouns A pe nh Elgin,IL 60120 DAY 9G5 DAYS A YEAR ti+ SPOT ELEVATION �9 SHEET TITLE: WARNING I / V -/ BUILDING STRUCTURE SITE PLAN �/ . UNDERGROUND GAS FLAG MARKER Ni \. A UNDERGROUND TELCO FLAG MARKER 0200/TRANSCENO-NIKE CORP ALL RIGHTS RESERVED CALL BEFORE - YOU DIG CALL SHEET NUMBER: 1(800)892-0 1 23 48 HOURS BEFORE YOU DIG C1.1 • ENLARGED SITE PLAN 3 ENLARGED SITE PLAN AT ANTENNAS SCALE: I" = 20'-0" � e SCALE: 3/32"=I'-0'I T • •1'Tobile• • 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 `j Fl. 13(7-0"T/TOWER�i Tel 773-444-5400 q Fax 773-444-5521 1S EL 130-0"T/TOWER4 Fil Fl 127-0'CL NEW T-MOBILE ANTFNNAS 4 Mir . OW J - FI 121'-O"CL NEW T-MOBILE ANTFNNAS \ Fl 1 27-0"CL NEW T-MOBILE ANTENNAS il eip _ _ Transcend-Nike Corporation 2112 W.GALENA BLVD.STE.8-186 AURORA,IL 60506 TEL.630-688-1281 FAX.630-888-1282 EL 12I'-0"CL NEW T-MOBILE ANTENNAS 4 TNC PROJECT NUMBER:817 - (6)NEW DIRECTIONAL PANEL ANTENNAS MOUNTED TO UNIVERSAL TRI-BRACKET AS SPECIFIED BY TOWER karnry, inc. CONSULTING ENGINEERS CONTRACTOR TO REFERENCE TOWER MANUFACTURER 406 Meadow Ridge DRAWINGS FOR ALL INFORMATION,DESIGNS,DETAILS, Prospect Heights,IL 60070 ERECTION,AND ASSEMBLY INFORMATION Tel.(847)870-7413 Fax:(847)670-7434 (G)NEW DIRECTIONAL PANEL ANTENNAS MOUNTED TO E-Mail:kamryeng.com UNIVERSAL TRI-BRACKET AS SPECIFIED BY TOWER MANF. o `r8 9 0 o CONTRACTOR TO REFERENCE TOWER MANUFACTURER 4.' DRAWINGS FOR ALL INFORMATION,DESIGNS,DETAILS, N 7 ERECTION,AND ASSEMBLY INFORMATION JJ I- F ww w tY z LJ a H w O , W O UJ U F o D_ 7d to d rn 0 o O .. , O m F 0 U. ENLARGED SITE PLAN AT EQUIPMENT o 0 co 0 0 i 0 W to oD co ~ LLI U SCALE: 3/32"=I'-0" CO COW U NEW 130-C7'T MONOPOLE TOWER NEW 130-0T MONOPOLE TOWER BUSHES AND SMALL TREES TO REMAIN Z ,- 0 0 0 0 ~�GK Y�8`°tti p it Q�.�4062-033842 t ii Z.. REGISTERED '• l/ NEW GPS ANTENNA MOUNTED TO ICE BRIDGE POST i i Pt�OFESSION/�LL NEW T-MOBILE BTS EQUIPMENT ,1 ENGlNEEH i � 11 OF .~ BUSHES AND SMALL TREES TO REMAIN t= ..». � i' 1 1:INolt°`1` ~ NEW GPS ANTENNA MOUNTED TO ICE BRIDGE POST -\ FIRE STATION RL NEW T-MOBILE BTS EQUIPMENT �' I 1 NEW OWNER APPROVED BRICK TO MATCH EXISTING \� I" / FIREHOUSE; CH37-975C !ICI 1 �21 116"',.'IMI ..-_ ._. ::r. ....... ..... -.-, ,.; r RAWLAND 'j�Tj \ Tlr�flf /lR1�RTJrrTal1R,.=-7,: fJ.YiL .�4G' .' _r.._ .'r.�rartSEd�srSt�a?taiu'3 4J I srurs�_-_-___, , i4, 599 S McLean Blvd. 12112 /I. `^ T r�x .:, w�w wi+�i"-"ca� Elgin,IL 60120 - __ _ :����. . c3 SHEET TITLE: •' .'• NEW OWNER APPROVED BRICK TO MATCH EXISTING ``ly4 Y ..T.,s�.ra .ay.r �vrssa,.r'si�wxssvrwlla i t \_ 41 - FL 81 4 3 T/FOUNDATION Q FIREHOUSE; 1 I AK! tor` ��V ;�v k `,.l '� ELEVATIONS si I r ��`''!`ie.t- I '7'�•s�il�����5 _ L_ EL 0-0'1814.67 T/EXISTING GRADE OI TOWER L� 02001 TRANSCEND-NIKE CORP ALL RIOMS RESERVED Me4KIT 4� re. Iv I` ,a *i� SHEET NUMBER: rr I. C3.1 r : UTILITY GEAR SUPPORT CABLE BRIDGE DETAIL • • SCALE: NTS SCALE: NTS T • Mabile• • I a-O"MAX 8550 W Bryn Mawr Ave.Ste 100 GALV.POST CAP;POST TO BE FIELD CUT; Chicago,IL 60631 it / RAW EDGES TO BE SEALED WITH COLD [/ 6'-a'o.C. — _ GALV. Tel 773-444-5400 /// Fax 773-444-5521 rL. U-BOLT ASSEMBLIES AS RECOMMENDED 1 C) G"(�) —_ — ' .--- BY MANUFACTURER INFINPk IN 10" 2-0"BRIDGE SUPPORT BRACKET ,-, 41/2"0 SCHED.40 GALV.PIPE W/CAP; _ \ I II I g Transcend-Nike Corporation 2112 W.GALENA BLVD.STE.8-166 ' • .--i I 15/8'x 1 5/8'X 15/8'GALV STEEL , AURORA,IL 60506 • STRUT B-UNE N822);FASTEN TO POST W/GALV. 6"(ryP) TEL.630-688-1281 U-BOLTS,WASHERS,AND NUTS AT EACH POST;TY' - ' U , FAX.630-6 8-1282 I I f \ TNC PROJECT NUMBER:617 • L- _J I VERTICAL COAX"TRAPEZE' • • • kamry, inc. • j 6"0 GALVANIZED STEEL POST CONSULTING ENGINEERS Q 406 Meadow Ridge Prospect Heights,IL 60070 bii T:z ol I'-0"0 CONCRETE FOOTING Tel.(847)670-7413 LL �s"^=_..N. __ - ,.-: xi----L — w.2 Tt.L,.u. I E Mail kam7e74 corn Z v v O fa n .. .— -- l - Q N �'I A )a= a N co 7 IA d M 3"CLEAR IIIFE tY 2 I'-6'Tr? S W a_ II-- W J � ES F o 7 W d = cn irAW. RETAINING WALL SECTION DOUBLE GATES " ,z0 o m ° CALE: NTS SCALE: NTS o m 0 0 D ° i o rcn co - U C.9 rn U) SCHED.40 GALVANIZED STEEL U ADHERE CAP UNIT TO TOP UNIT GATE POST W/CAP AND GATE W/CONCRETE ADHESIVE 12-0, HINGES GATE OPENING DRAINAGE SLOPE / r I'_O" O N co v In 1 z O O O O O IMPERV. S FILL I I T_�;..7-7-- Tat -1- 'I 1 7T1_ �+~ \GK Y••BF�t 8 14.0 T/WALL _ MIN 2"THK r- -(-=-r- ) 1 l -1 O olr I41 T -? - 1�`]�} SPUT BLOCK CMU •••�,9*�r j_/J-'-rF.:1—f TYPE 2 I i I _ WALL;PAINT WHITE r ; /, - . a • a ER APPROVED * Q F' REINFORCEMENT I .,I_,_I � REGISTERED �,-)--,--�-r L�L�---l-�L PER OWN PRO ��L . t,.l I • RETAINED BACKFILL -•.. 111 111 - SAMPLES(fYP) / :• • e i; / C L. :� I__._.1.....1.. I. 1. p • PROFESSIONAL s II ._....1 I. 7 ._I_ .__T_ 1 _T 5 r I I'® ■Ir, tC._..:t:::_.::_...:--I- ..L. :l L._T ! ENGINEER i 0 (_, •- REINFORCEMENT T r I 7 1 jt r . ......Liii...1.1.1:::r1 i t N.s. Of `.= ;'' APPROXIMATE EXCAVATION i -'_._I_!_. 1._._1 _ CEDAR DOUBLE SWING ‘tt`LINO��.. LL,, L'::.:1 ` I' GATES;PAINT RED PER NNVOL� m,r_ I._h's....�...�,_. .1._._l. ....I_. OWNER APPROVED SAMPLES T/FINISHED GRADE VIF DRAINAGE AGGREGATE; "- l T. D'I7 4 TYPE - INFORCEMENT(TYP)/ 12"THK MIN. I .... 3 , 1 t T 1 I 7:__ �r 'r I i I FIRE STATION RL 1 r / CH37-975C 1 ..:.: ( -. �._. 1 RAWLAND REIN-.•- ED SACKFUL; ra jc4 'm4 I O' 95%ST •ARD PROCTOR [�"'- lL" -` `T" ` 599 S McLean Blvd. DENSITY RE •RCED BACKFILL ,z,�x ' Y. =- I Elgin,IL 60120 -"`i I od ..\ CONCRETE FOUNDATION FOR DRAIN TILE 4'PJrO AT END - _ '_L`..:.�-'�-.;ii= _ - GATE POST;REF.FOUNDATION SHEET TITLE: SECTION OF WALL OR(a�40 0'. NTERS •'--fF=="F'1 c NOTES FOR CONCRETE DESIGN (MIN.SLOPE I/100) x�ti"-yT-- (Ti?) LEVEUNG PAD 6"MIN. I STAINLESS STEEL LOCKING DETAILS SUDE BOLT(MCMASTER-CARR I,-0,( /1161 A42) •20CA TRANSCEND.NINE CORP.ALL RIGHTS RESERVED CONT OR TO SUBMIT SAMPLES OF FACING UNITS T ER FOR APPROVAL BEFORE COMMENCEMENT SHEET NUMBER: F WORK C4.1 . ENLARGED SITE PLAN 1 SCALE: NTS T ' ilViobile' ' 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 * . " AREA FOR FUTURE SHELTER IXPANSION Tel 773 444-5400 y VFax 773-444-5521 D(ISTING ASPHALT PARKING LOT;CONTRACTOR TO DOCUMENT T ilk • W/DETAILED PHOTOGRAPHS OF CONDITION PRIORTO START OF CONSTRUCTION AND SUBMIT TO T-MOBILE BfISTING CONCRETE CURB TO REMAIN; Transcend-Nike Corporation • - - - • • - - . • • • T/CURB 8 15.1 2112 W.GALENA BLVD.STE.8-188 , . AURORA,IL 60506 NEW I O'-O'W 11TIUTY EASEMENT TEL 630-688-1281 FAX.630-688-1282 * * . . ' " . . . Z \ TNC PROJECT NUMBER:617 814'�• kamry, inc. 1 CONSULTING ENGINEERS 814'-9• H•-- 4'-6" 14'-6' 406Pro Meadow hE,I Prospect Rid IL 80070 Tel.(847)670-7413 . . . . . . . . . I —— Fax:(847)670.7434 ge ------_— ! ------_--_— ` E•Mail:kamryerg.com ` I _!_ I� NEW T-MOBILE 25'O X 25'-O'LEASE AREA v . • / o 0 0 0 9 el .1 Q N N7 m N') `I' I Cp N . . I I— , . LEASE AREA 1 \ TOP COURSE:4'MIN.OF COMPACTED CA-7 COARSE AGGREGATE Uj 5 W d Z w BASE COURSE:4'MIN.OF COMPACTED CA-6 COARSE AGGREGATE Z 5 bi OM _ ... }..: '1 ....._ GROUND PREP.MIRAfI 500 WEED CONTROL AND GROUND STABILIZATION FABRIC — O o O in rt e cc n 1 i 1 I" x GIG OP 1 y OLL W 0 w m ./ LL . . .� I I .*. • A?1VWRJd ex Gig 1�' £x Gig -I -�°fir• NEW T-MOBILE BTS EQUIPMENT; O 1- °°♦•1 LO w = w . . . . u� I I.. r•Ateoll FOUNDATION T/SLAB 815.2 =b I y o J' E<ISTING LEGEND NEW v_ D 0 . . , I I v .i°i°i°i°°�s. 3� ' IA, I• k0 ?. '' .. _ I SANITEWER NEW BRICK SCREEN WALL; OWNER 55 5S- -Ia „-m. /�.9A!'�►�4� >"►�. r'� APPROVED BRICK TO MATCH FIREHOUSE NEW METER MOUNTED TO H-FRAME; . • + I 14+6°�°°� "� `�� e«• - • I 5T5 STORM SEWER STS— REF.E I.I I ` 41' `!� °►�. .- NEW 2'-OW CABLE BRIDGE;USE VERTICAL LADDER e or II • i �°`4 AS REQUIRED FOR COAX ENTRY AT TOWER PORT HOLE yV-- WATER MAIN W-- d N a v1 . . . . . . I - °�Oj>4.''�/4_, ���a,4e°9, - Off— OVERHEAD ELECTRIC OE— i 31 �®� ♦ Q4� q4� '- I NEW SPLIT FACE RETAINING WALL:REF.SHT.52.t •.�'�^�``"�,iLL . • I I ` 1x4O0 °4►°°°441aliS f UE— UNDERGROUND ELECTRIC - U� 111. r t.�`V� 1..��/r/� 814'-9' • 2-0" .4!4 V 1 . 13'O", 1 814.-6• OT OVERHEAD TELEPHONE or--- ' r • �•.9�', e .tkr;'�p62-0338d2 7r- r .� `•• UT— UNDERGROUND TELEPHONE UT— f 4': REGISib"Q ) . - - ___ - - - - _ ___ — 1 y:— --J .0 PROFESSIONAL z• i // ::.: • ��____.M NEWMONOPOLE FOUNDATION;REF.TOTOWERMANE.DRAWINGS- \ ' 1 I-6 ;INS �7/E SURFACE DRAIN f tr� - ')/ '/ ..,`LEASE - �/•.... O UGHT STANDARD 0 t :t /4+I N O,0010e "�"'"'�w • \ "-N CONTOUR UNE `.N �~ • Y.._.2� /,.' I NEW 7-0'H BRICK SCREEN WALL;BRICK TO MATCH 9 ,.9 '\ I SHELTER AND FIREHOUSE Op MANHOLE 0 FIRE STATION RL y CH37-975C ;\ 'I NEW 12'-O'W DOUBLE SWING GATE —x—*— FENCE --x—x— RAWLAND \, / J STREET EIGHT 599 S McLean Blvd. - ` Elgin,IL 60120 -;�' `"-•"'� NEW I O-O'W ACCESS/UTILITY EASEMENT ,��+ SPOT ELEVATION ,.9' SHEET TITLE: .. \\ (. -S� TO NEW LEASE AREA;GRAVEL PAVED; Y r REF 2/AI.I V BUILDING STRUCTURE17777 ENLARGED BUSHES AND SMALL TREES TO REMAIN\t / A UNDERGROUND GAS FLAG MARKER SITE PLAN /A' A •2004 TRANSCEND-NICE CORP.ALL RIGHTS RESERVED UNDERGROUND TELCO FLAG MARKER SHEET NUMBER: C2.1 i EQUIPMENT/ FOUNDATION PLAN " l(?�71 e ,,. 1 SCALE: NTS 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 Tel 773-444-5400 Fax 773-444-5521 / UTILITY POLE WITH NEW POLE MOUNTED TRANSFORMER / .T,.. SUPPUED AND INSTALLED BY UTILITY COMPANY. ELECTRIC SERVICE METER SOCKET 200AMP, I 20/240V SINGLE ilik • 0 '/ PHASE 3 WIRE W/BY-PASS FEATURE(MILBANK#U7G07-200-RL-K( - i ^// OR APPROVED EQUAL);FURNISHED AND INSTALLED BY CONTRACTOR �j. / / NEW 200 AMP NEMA 3R OUTDOOR LOAD CENTER; ELECTRIC SERVICE RISER CONDUIT(1IEAVYWALIa-STUB (AS MANF.ATLANTIC SCIENTIFIC CORP.) Transcend-Nike Corporation 2112W.GALENA BLVD.STE.8-186 UP WOOD POLE IC/-0"ABOVE GRADE AND COIL ENOUGH EXTRA AURORA,IL 60506 CONDUCTOR TO REACH TRANSFORMER-COORDINATE ./ ALL ACTIVITIES AND SPECIFICATIONS WITH UTILITY COMPANY RELOCATED GENERATOR RECEPTACLE TEL 630-688-1281 FAX.630-688-1282 / V. TNC PROJECT NUMBER:617 ii' 30W X 241H X 12'D NEMA 3R ENCLOSURE 1 amry, inc. W/BACKBOARD FOR TELEPHONE Prospect Heights,IL 60070 Tel.(847)670-7413 Fax:(847)670-7434 // E-Mail:kamryerg.WM ./ ~ N r-T-.w 1� /" 1 .J I H -. `lerZ � I -L..l:� �c l�l:-tte� 1xri+ ,f-'I, • = Ipyl K a=ux�(7`a�. UJ 3 2 cc Z • '�,L-L - '� '1 .1;- l "; I d _ Ln • 1 - , u=.. W LJ.I a H W 1 I 'i 4,0 ;" =1�1 s -1 a �-, `_ . 7-i1> ZD W p I j CY r-[I-' I—•I Z Mcn in. ele '- •=n -.-_ _ _ �-�,. F 6- Q = tco CTcc p m p U I `tom to 2 p cc W m C�TO EQUIPMENT CI p W u- ZU` 12 NEW 5/5'DIA.X 120'LGROUND ROD p = W FOR ELECTRIC SERVICE.PLACE MINIMUM 6' CO - V HEAVIWALL 90'SWEEP 3 EA 3'RIGID(UNDERGROUND) ABOVE GRADE-DO NOT CONNECT TO ANY OTHERCO 7d- EACH W/3-SOOMCM,SO GRTHWN GROUNDS - 4'0 HEAVEYWALL 9O°SWEEP 2'DIA.PVC CONDUIT FOR TELEPHONE SERVICE.SEAL ALL JOINTS.42'MINIMUM BELOW FINISHED GRADE.END TERMINATING INSIDE THE SHELTER SHALL BE COMPLETLY p N M 4- in SEALED AFTER INSTALLATION OF TELEPHONE SERVICE BY LOCAL Z o 0 0 0 0 UTILITY COMPANY.SUPPLY FULL LENGTH PULL ROPE; ��ti\tl SUPPUED AND INSTALLED BY CONTRACTOR ...? v y.•�il�� w °c 1 CCC[� 4Qti.062 33842 •9 �i �. REGISTERED i� i PROFESSIONAL " i J t ENGINEER F* r FIRE STATION RL CH37-975C RAWLAND 599 S McLean Blvd. Elgin,IL 60120 CONTRACTOR TO COORDINATE ALL ACTIVITY W/UTILITY COMPANIES SHEET TITLE: UTILITY RISER NOTE:LOCATION AND SIZE OF ACTUAL SERVICE COMPONENTS(TRANSFER SWITCHES,PANELS, TRANSFORMERS,ECT.)WILL VARY-THIS DRAWING I5 INTENDED TO DEMONSTRATE RELATIONSHIP ONLY O 2004 TRANSCEN6NNE CORP.All RIOUTS RESERVED SHEET NUMBER: E1.2 j GROUNDING PLAN T SALE: I/8" = I'-O' LEGEND AND IEYNOTE$ 1 a Mobile' ■ O Chicago,8550 W Bryn Mawr Ave.Ste 100 I O.0 x 42'DEEP INSPECTION WELL(ICV BY CARLSON INDUSTRIES OR APPROVED IL 60631 EQUAL;INGWDE SPECIFIED GROUND ROD INSIDE WELL W/CADWELD CONNECTIONS Tel 773-444-5400 16 ® 5/8'0 x 10-0'LONG COPPER CLAD GROUND ROD;MIN.42'BELOW GRADE Fax 773-444-5521 OAT MINIMUM I0'-0I'O.C. 7 ''''���/ • EXOTHERMIC WELD CONNECTION r.._.._.._.._.._.._.._.._.._.._.._.._.._ ._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._. _.._.._.._.._..� 0 MECHANICAL CONNECTION � •. � j • I 'O I I —G— NEW GROUND RING Oj Transcend-Nike Corporation •� I —G— EXISTING GROUND RING AURORA,t2W.GALENA BLVD.STE.8-186 I G o=' 1 4 TEL.630-688-1281 O #2 AWG TINNED SOUD BARE COPPER CONDUCTOR FOR EXTERIOR GROUND RING FAX 630-688-1282 9 Id co ii"'� j I PLACED MIN.42•BELOW GRADE OR 6'BELOW FROST LINE;FURNISHED AND _ JI INSTALLED BY CONTRACTOR INC PROJECT NUMBER:617 O / 2 COPPER GROUND BAR MOUNTED AT BASE OF TOWER kamry, inc. tr CONSULTING ENGINEERS 7 / "- \ I 3 O #2 AWG INSULATED STRANDED COPPER CONDUCTOR CADWELDED CONNECTION • 7 406 Meadow Ridge s,I O j TO GPS ANTENNA PIPE MOUNT(TYPE VS)AND CONNECTED TO EXTERNAL Prospect Heights,IL 60070 j , - - -----L--n--, o ° iCisP GROUND RING(TYPE PC) 1 2 I I � 1 I Tel.(847)670-7413 i •_`' ! D Fax:(847)870-7434 , I I — I O 4 TO TOWER GROUND BAR AND EXTERIOR GROUND RING;#2 AWG TINNED 5OUD BARE COPPER CONDUCTOR SE 2'PVC E-Mail:kamryeng.com J • 1 - \ ` / RACEWAY PFI'.1�.> ( I 75,: ) �� °° ., j OS #2 AWG TINNED SOLID BARE COPPER CONDUCTOR FOR FENCE GROUND CADWELD o 0 0 0 0 @TS y_ I I 3T•_,#3 ( j I TO FENCE TYPE V5,CADWELD TO GROUND RING TYPE TA Q N o In m OI A2 AWG TINNED SOLID BARE COPPER CONDUCTOR W/TWO-HOLE LONG BARREL COMPRESSION N `r • I © WG(EACH END),(2)5/1 6'0 BOLTS AND STAR WASHERS CONNECTING LOWER TOWER GROUND BAR TO UPPER TOWER GROUND BAR III 44 a I a F © o .....1 a }•' t a O7 NEW EXTERIOR GROUND BAR FOR COAX GROUNDS AT EQUIPMENT,J .. ° .q W Cr d' Z • d I W W a w I I O8 #2 AWG SOLID TINNED BARE COPPER CONDUCTOR CADWELDED TO GROUND RING TYPE XB 0 W O w 0 •., S F o 7d : 0 WAVEGUIDE BRIDGE GROUND,#2 AWG SOUD TINNED BARE COPPER CONDUCTOR CADWELDED a 8 cc 0 O L.._.;_.._.._.._.._.._.._. J 0 0 in H U ROUND RING(TYPE GT)AND TO POST(TYPE VS) cn O LL 03 W cn LL uj uj 0 CCZD cc W m WAVEGUIDE BRIDGE TO POST GROUND,#2 AWG SOUD TINNED BARE COPPER CONDUCTOR CI 0 D Li. Q 0 co 5 CADWELDED(TYPE VS) 0) 0 CO DU tu Z O I I PLINTH GROUND BAR SUPPLIED W/PLINTHco 0 • O ® 27 STRANDED GREEN INSULATED COPPER WIRE FROM GROUND BAR IN PLINTH TO • 8 COAX GROUND COLLECTION BAR(2 REOD)FOR EACH BTS © 0 #2 AWG SCUD TINNED BARE COPPER CONDUCTOR FROM PPG CABINET TO GROUND RING TYPE XB O C.4 CO v v1 Z o 0 0 0 0 Q �.ti vi 14 5/8'0 COPPER CLAD ELECTRICAL SERVICE GROUND titi.��� ,tL NOTE:CONTRACTOR TO LOCATE AND TEST ANY EXISTING GROUND 1 062-033842 '•��F LAYOUT SI M I LI AR SYSTEMS BEFORE CONNECTIONS ARE MADE;FINAL GROUND SYSTEM ♦Ct / r M2 AWG TINNED SOLID BARE COPPER CONDUCTOR W/TWO-HOLE LONG BARREL COMPRESSION REGISTERED SHALL BE TESTED AND THE RESULTS APPROVED BY PROJECT MANAGER COLLECTOR BOLTS AND STAR WASHERS CONNECTING COAX GROUND KIT TO GROUND /4`• ;Z 1 PROFESSIONAL r 1�= ��illo. ENGINEER ,� r '11 <4 LIN00-1- 1. THE EXISTING GROUND SYSTEM IMPEDANCE SHALL BE TESTED AND/OR CERTIFIED TO BE 5 5. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY CADWELD CONNECTIONS. I I. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT FIRE STATION RL OHMS OR LESS.IF THE IMPEDANCE EXCEEDS 5 OHMS.REPAIRS OR ENHANCEMENTS SHALL BE MATERIAL. CH37-975C MADE TO THE EXISTING GROUND SYSTEM TO BRING IT UP TO THE REQUIRED STANDARD. G. SERVICE TO EQUIPMENT SHALL BE 120/240V,200A,SINGLE PHASE. RAWLAND GROUND CONDUCTORS FROM THE EQUIPMENT AND ICE BRIDGE SUPPORTS SHALL BE TIED TO 12. Al_ EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS 599 S McLean Blvd. THE EXISTING GROUND SYSTEM USING EXOTHERMIC(CADWELD)CONNECTIONS. 7, IF TELCO REQUIRES POWER AT THE RACK INSTALL I'CONDUIT. OTHERWISE INDICATED. Elgin,IL 60120 2. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 8. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC(CADWELD). 13. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL,5/8"0 10-FT.LONG, SHEET TITLE: AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 30"BELOW FINAL GRADE OR 6" 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS 50 THAT 9. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR 4 EXTERIOR) SHALL BE FORMED BELOW FROST LINE FOR MAXIMUM DEPTH. ACCESS TO EQUIPMENT 15 NOT BLOCKED. USING TWO(2)HIGH PRESS CRIMPS. GROUNDINGu 4. THE CONTRACTOR 15 RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND 10. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP 4 HAVE GROUNDING PLAN N UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE A VERTICAL SEPARATION OF 5"FOR EVERY ADDITIONAL CONNECTION. '1 GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 0 2004 TRANSCEND-NIKE CORP.ALL RIONTS RESERVED SHEET NUMBER: E2.1 ' ,EQUIPMENT/FOUNDATION PLAN m COAX AT BASE OF LEG SCALE: NTS q SCALE: NTS '1' • Mobile. ' 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 Fax 773-444-5400 Fax 773-444-5521 ((Prig /y COXIPL CABLE GROUND KITS WITH FIELD 1(� 3/1 6"THK.COATED STEEL COVER APPU ED LONG BARREL COMPRESSION LUGS, . 4 l(� 1 (2)3/8"DIA.BOLTS ANS LOCK WASHERS. r I—2" I0'0 X 42"LONG SCHEDULE 40 PVC (ANDREW#24I Ob8-7)(SUPPUED AND .J_ GROUND INSPECTION WELL(HARDER INSTALLED BY CONTRACTOR) IL JI � .- SPECIFIED COMPOUND GRADING Transcend-Nike Corporation 2112 W.GALENA BLVD.STE.8-186 '•.. •• •" MATERIAL 20"X 4'X I/4"COPPER GROUND BAR AURORA,IL 60506 _ 1 1 L—? 11W (FURNISHED AND INSTALLED BY CONTRACTOR) _ I I—_ _ TEL 630-688.1281 '— I ( __II FAX 630-688-1282 I- III-_`' • #2 SOLID TINNED COPPER CONDUCTOR TNC PROJECT NUMBER:617 (4)2T'SLOTS FOR.GROUND ELECTRODE CADWELD TO GROUND RING(TYPE NC - ...1 I l" CONNECTIONS ORSIMIUAR) inc.ROUND WIRE AS SPECIFIED IN kamry, • 11 GROUND PLAN •-,••-•' CONSULTING ENGINEERS ____ ' /2"PVC CONDUIT SECURED TO WATER TOWER 406 Meadow Ridge • LEG WITH(2)GALVANIZED"C"CLAMPS. Prospect Heights,IL 60070 ' (FEI BY CONTRACTOR) Tel.(847)670-7413 Fax:(847)670-7434 E-Mail:kamryerp.cam CABLE HANGER SYSTEM AS SPECIFIED BY STRUCTURAL ENGINEER AND .f 0 0 0 0 ATTACH Vz"PVC TO TOWER CROSS BRACING OR FLANGES 0 N `� C csi M V In W W CC Z 5 w a H w w 2 w p o cc < , c EXOTI1ERMIC WELD TABLE GROUND DAR DETAIL N o 0 - o SCALE: NTS SCALE: NTS o o 0 7 p)) o x w CO 0 U Z U Q lir 41* %........4r.,. I 20" ' GLASTIC Z o o 0 0 0 Type GR Type LJ Type PC Type TA I I/4" v; INSULATOR y�,.to t-W SINGLE CABLE TO TOP OF PARALLEL TAP CONNECTIONS TEE CONNECTIONS OF I �b 3 RW.) /z� i1 Y. 1h TAP OF CABLE TO EDGE • GROUND ROD. OF HORIZONTAL CABLES. HORIZONTAL RUN AND TAP ..'~ ••••' t jl BUSBAR.HORIZONTAL FLAT t Irl0000 0000000000000000000 I ,: �'P`C ••� ��, CABLES. Q '�,�r��.�p,n � :I 7/6" .. ' REGISTERED 2 — 4" _ 00000000000000000000000 } ��:• i1c�7tSTEFD 'y�I ��� 0000000000000000000o CI • e L� -= �� i 2 lw0000000000000000000 v ri�i P � / �� t O 10. I. `` v 3/8'DIA.HOLE;44 TOTAL t� h»� � Type HS Type XB Type NC Type GT 3/B"W X 5/8"L SLOT;44 TOTAL 20(FURNISHED X X 4"COPPER GROUND BAR 9_ , �Ca�� BY CONTRACTOR)SHELTER MANUF./INSTALLED tll,`;; 0 24ti HORIZONTAL COPPER CROSS OF HORIZONTAL THROUGH CABLE PLUS TAP THROUGH CABLE TO TOP 12 CADWELD CONNECTION(TYPE U) CONDUCTOR TO FIAT STEEL CABLES LAPPED AND CABLE TO TOP OF GROUND OF GROUND ROD. SURFACE OR TOP OF NOT CUT. ROD. FIRE STATION RL HOR • PIPE. #2 SOU TINNED COPPER CONDUCTOR CH37-975C CADWELD TO EXTERNAL GROUND RING RAWLAND IrWPil (TYPE NC OR SIMIUAR)(CONDUCTOR SUPPLIED BY SHELTER MANFJINSTALLED599SMcLeanBY CONTRACTOR) Elgin,IL60120Blvd. a.. a.t./ CLEAR RTV SIUCONE SEALANT(Tl'P.) "` ` / %z"PVC CONDUIT MOUNTED TO SHELTER SHEET TITLE: WALL WITH(2)GALVANIZED"C"CLAMPS. Type VS Type VS (F41 BY CONTRACTOR) GROUNDING CABLE DOWN AT 45Q CABLE DOWN AT 45Q TO DETAILS TO RANGE OF STEEL VERTICAL STEEL SURFACE. PIPES. O 2001 TRANSCEND-NIKE CORP.AU_RIGHTS RESERVED SHEET NUMBER: E3.1 5 12000 SPECIFICATION TABLE1111 51 2000 B.T.S.CABINET LAYOUT S 12000 B.T.S. MOUNTING DETAIL SCALE: NTS SCALE: NTS SCALE: NTS '1' • ?Mobile' ' HEIGHT 75.19 IN Chita o,IL 60631 r Ave.Ste 100 • WIDTH 53.14 1N B �K AIR INTAKE VENTS Tel 773-444-5400 DEPTH 25.59 IN Fax 773-444-5521 I MAXIMUM WEIGHT 12I 2 Lb(FULLY EQUIP) 2F-TYPE USER CONVERTERS INTERCONNECTIONS FOOTPRINT 2.09M 22.495ctR. 1 EMPtYWEI(,.hT.... .......... ..... 396Lb(179.6.KG)" .- ..,.,..,.. IIIIk OW 25.59' VOLTAGE 240V+/- 10% %.; MAX.POWER(240V) 6500 W 512000 B.T.S. ._NORMAL POWER 3238 W - KCAL RAGS BnTT. CABINET Transcend-Nike Corporation MAIN CIRCUIT PROTECTION 50 A r 2112 W.GALENA BLVD. or ora 508 MAX.HEAT DISSIPATION ,.22100 BTUMOUR J m� _fl AURORA.IL 1281 DRX-ICO A 1 4f TEL.630-688-1281 NORMAL HEAT DISSIPATION 11000 BTU/HOUR FAX.830688-1282 OPERATING TEMPERATURE -40'to 112'F = El_0_ 0. INC PROJECT NUMBER:617 n USER RACK I ..(-iO' to 50' C) G DRX. �0 gun�0��II I] �0 75.I9' MAXIMUM OPERATING HUMIDITY 100% 11{�LR�,1 pp�, pp,, pp,, army MAX.LEVEL OF ACOUSTIC NOISE 65 DB '��D LJ13 U1 LIB LIB t) 4 4 CBCF L E inc. a GROUND CABLE 20 MCM a a PCU RECTIFIER RACK 4�CONSULTING Meadow Ridge ENGINEERS ANTENNA CONNECTORS 4RX SPUTTERS J _� ��� � i Prospect Heights,IL 80070 CABINET OUTPUT 403 DBM ..... ....._. .. DRX-ICO B m TeL(847)870 7413 RECEIVE SENSITIVITY -I 15 DBM o _ -; > > PA-ICO Fax:(847)8707434 OUTPUT POWER AT CABINET ANTENNA n I E-Mail:kamryerq.com 38.QDBM ' O' a° P 0 O 00°0°0D0°0°0°0°0°0°0°0�t I CONNECTOR(h2D) 6 DRX' 00 0a 09 (((�'�0'00 o a o 0 0 0 0 o o one e 12 PA POWER ENTRY `✓ a I v I0 'C`0. MOUNTWG BASE v v e . NOTES: BASE UNIT `� �/ CI N v1 +- 4RX SPUTTERS{ FILLER -• AC BOX ( I, /�, O CV v U I. 13 HOURS OF BATTERY BACKUP 15 PROVIDED FOR FULL TRX p p p p 0 J OPERATION.AN ADDITIONAL 0.5 HOURS 15 PROVIDED FOR THE 4-. G1 C] 4. ` 0 j �,/ , 3 I BCF WITHOUT TR(OPERATION. 4Rf COMBINERS LI LJ ,8 RF-COMBINERS I a W -- fY Z a o o a ooaoa _ oa II Z ws oW Ti 2.MAXIMUM 15 DEFINED AS BATTERIES CHARGING AND HEATERS 1 0 W Z W 0 ACTIVE.AUXILLARY I I OV OUTLET POWER MUST BE ADDED TO FILLER ® ®® FCOM-co $0 9 F o ¢ co THIS FIGURE. J 0 v 53.14' U cc LL c0 1- U In 3.NORMAL 15 DEFINED A5 BATTERIES NOT CHARGING CC 45.10' 0 0 0 U- Z O LU 0) p C CO - j U WU' AND HEATERS NOT ACTIVE. CO 7a to U S 12000 B.T.S.CABINET FOOTPRINT 51 2000 MOUNTING BASE-DETAIL < * 4" NIPPLE DETAIL SCALE: NTS 4 -SCALE: NTS SCALE: NTS , — — , .401 MOUNTING BASE (EXTEROR) Z o 0 2 0 0 .� a Illka / GKY ,AYt 0 I ✓cti WL'V�7NV't2 ••• .r ti 4'THREADED 8 / I— -1 I 4 ', N` / NIPPLE W/ I �' JIGGIrrJ[[{�cGr1G.Y 4 I ��� , 0 S LOCK NUT I PROFESSIONAL I I T ENGINEER r 42.12" I I FRONT 0 , 7....":„.. / Nt`tLrNo`1UNIVERSAL PLATES '���K 1"MIN.SPACING I‘WW.4 L— J /I POWER ENTRY REPLACE SIDE PLATE MOUNTINGBASE BETWEEN CABINETS INTERJO REQUIRED HERE,ATTACH ON ( R) lot, FIRE STATION RL I 1 ,/ I 6I.02" p p ,� ]► INSIDE WITH SUPPLIED p CH37-975C \ �p 0 ` ► HARDWARE p o 0 • . ► RAWLAND \\ . 0 0 1, _—L_ UNIVERSAL LES p �, 59E gin,,IL 60120cLean vd. o 4.*,,il / 0 ► _ '���� �. SHEET TITLE: N 1 �` � �/ EQUIPMENT \ FRONT _ l DETAILS 53.I4' 1 _-� AW 0.0 raANSCENMKE CORP ALL RIOWS RESERVED 45.10" MOUNTING BASE ,; II MOUNTING BASE SHEET NUMBER: FRONT ACCESS FOR MAINTENANCE w (INTERIO \J / \ / (EXTERIOR) \/y/ � E4.1 T • Mobile• • 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 • Tel 773-444-5400 10 Fax 773-444-5521 / U It e IT Mk 111 411.11i Transcend-Nike Cnrpor:znon REMOVE ALL RUBBISH FROM AND ABOUT THE BUILDING AREA,INCLUDING A. ALL WORK SHALL BE IN ACCORDANCE WITH APPUCABLE LOCAL.STATE AND SITE WORK AND DRAINAGE 2112W.GALENA BLVD.STE.8-186 GENERAL REQUIREMENTS ALL THEIR TOOLS,SCAFFOLDING AND SURPWS MATERIALS AND SHALL FEDERAL REGULATIONS.THESE SHALL INCLUDE BUT NOT BE UMITED TO THE AURORA,IL 60506 LEAVE THEIR WORK CLEAN AND READY FOR USE. LATEST VERSION OF THE FOLLOWING: EARTIflYOR�l5(CAVATION AND GRADING TEL.630-688-1281 PART I GENERAL FAX.630-688-1282 B. EXTERIOR:VISUALLY INSPECT EXTERIOR SURFACES AND REMOVE ALL EIAJTIA-222-F BUILDING OFFICIALS AND CODE ADMINISTRATORS BOCA FART I GENERAL TRACES OF SOIL,WASTE MATERIALS,SMUDGES AND OTHER FOREIGN NATIONAL BUILDING CODE,1999 TNC PROJECT NUMBER:817 I.1 INTENT MATTER. CITY Of CHICAGO ELECTRIC CODE,2000 I.I WORK INCLUDED:REFER TO THE SURVEY AND SITE PLAN FOR WORK A. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING I. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT INCLUDED.THEM DESCRIBE THE WORK TO BE DONE AND THE MATERIALS TO BE SURFACES. UNDERWRITER LABORATORIES APPROVED ELECTRICAL PRODUCTS AMERICAN ka /y��y'�� inc. FURNISHED FOR CONSTRUCTION. INSTITUTE OF STEEL CONSTRUCTION SPECIFICATIONS(AISC),MANUAL OF .2 RELATED WORK CONSULTING ENGINEERS 2. IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANUNESS, STEEL CONSTRUCTION ASD,NINTH ED.UFE SAFETY CODE NFPA-1 0 1- B. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO RE FULLY HOSE DOWN THE EXTERIOR OF THE STRUCTURE. 1997 A. CONSTRUCTION Of EQUIPMENT PLATFORM AND FOUNDATION 406 Meadow Ridge EXPLANATORY AND SUPPLEMENTARY.HOWEVER,SHOULD ANYTHING BE Prospect Heights,IL 60070 SHOWN,INDICATED OR SPECIFIED ON ONE AND NOT THE OTHER,IT SHALL C. INTERIOR:VISUALLY INSPECT INTERIOR SURFACE AND REMOVE ALL TRACES 1.1 I ADMINISTRATION B. INSTALLATION OF ANTENNA SUPPORT SYSTEM BE DONE THE SAME AS IF SHOWN,INDICATED OR SPECIFIED IN BOTH. Tel.(847)670-7413 OF SOIL.WASTE MATERIALS,SMUDGES AND OTHER FOREIGN MATTER FROM WALLS/FLOOR,CEIUNG. Fax:(847)670-7434 C. THE INTENTION OF THE DOCUMENTS IS 70 INCLUDE ALL LABOR AND A. BEFORE THE COMMENCEMENT OF ANY WORK,THE CONTRACTOR WILL 1.3 DESCRIPTIONS E-Mall kamryeng.mm REASONABLY NECESSARY FOR THE PROPER EXECUTION AND MATERIALS ASSIGN A PROJECT MANAGER W*10 WILL ACT AS A SINGLE POINT OF COMPLETION OF THE WORK A5 STIPULATED IN THE CONTRACT. 1. REMOVE ALL TRACES OF SPLASHED MATERIAL FROM ADJACENT CONTACT FOR ALL PERSONNEL INVOLVED IN THIS PROJECT.THIS PROJECT A. ACCESS ROAD,TURNAROUND AREAS,AND SITE WORK,AS REQUIRED. SURFACES. MANAGER WILL DEVELOP A MASTER SCHEDULE FOR THE PROJECT WHICH SHALL BE CONSTRUCTED TO PROVIDE A WELL DRAINED.EASILY MAINTAINED. WILL BE SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY'ME EVEN SURFACE FOR MATERIAL AND EQUIPMENT DELIVERIES AND C v v O D. E PURPOSE OF THE SPECIFICATIONS I5 TO INTERPRET THE INTENT OF THE WORK. O O • o O DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE,TYPE AND 2. REMOVE PAINT DROPPINGS,SPOTS,STAINS AND DIRT FROM MAINTENANCE PERSONNEL ACCESS. Q co . CD Lc.' QUAUTY OF MATERIALS REQUIRED TO COMPLETE THE WORK. FINISHEDN15HED SURFACES. N 4 B. SUBMIT A BAR TYPE PROGRESS CHART NOT MORE THAN 3 DAYS AFTER THE 1.4 QUAUTY ASSURANCE O N 1.6 CHANGE ORDER PROCEDURE DATE ESTABUSHED FOR COMMENCEMENT OF THE WORK ON THE , E. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SCHEDULE.INDICATING A TIME BAR FOR EACH MAJOR CATEGORY OR UNIT SHALL BE CONSIDERED A5 PART OF THE WORK NO CHANGES THAT ALTER OF WORK TO BE PERFORMED AT SITE,PROPERLY SEQUENCED AND A. VEGETATION 4 LANDSCAPING,IF INCLUDED WITHIN THE CONTRACT,WILL BE —1 THE CHARACTER OF THE WORK,THAT INCREASE INVOICABLE MAN HOURS A. CHANGE ORDERS MAY BE INITIATED BY THE OWNER.AND/OR THE COORDINATED WITH OTHER ELEMENTS OF WORK AND SHOWING PLACED AND MAINTAINED AS RECOMMENDED BY NURSERY INDUSTRY I- OR MATERIALS WILL BE MADE OR PERMITTED BY THE OWNER WITHOUT CONTRACTOR INVOLVED.THE CONTRACTOR,UPON VERBAL REQUEST FROM COMPLETION OF THE WORK SUFFICIENTLY IN ADVANCE OF THE DATE STANDARDS AND A5 WARRANTED FOR I YEAR FROM THE DATE Of SITE ISSUING A CHANGE ORDER. THE OWNER SHALL PREPARE A WRITTEN PROPOSAL DESCRIBING THE ESTABLISHED FOR SUBSTANTIAL COMPLETION OF THE SITE. ACCEPTANCE. LU W CC CHANGE IN WORK OR MATERIALS AND ANY CHANGES IN THE CONTRACT 5 W o - W I.2 CONFIJCIS AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HRS FOR APPROVAL. C. PRIOR TO COMMENCING CONSTRUCTION,THE OWNER SHALL SCHEDULE AN 1.5 SEQUENCING Z LIJ S C J CC SUBMIT REQUESTS FOR SUBSTITUTIONS IN THE FORM AND IN O W W () ON—SSITE MEETING WITH ALL MAJOR PARTIES.THIS WOULD INCLUDE ACCORDANCE WITH PROCEDURES REQUIRED FOR CHANGE ORDER p c G 1 N A MEASUREMENTS S ANTRACTOR STHAE SITE BEFORE ORDERING ANY MATERIALS OR DOING PERFORMED BYTHE CONTRA BE RESPONSIBLE FOR VERIFICATION OF ALL PROPOSALS.ANY CHANGES IN SCOPE OF CTOR WITHOUT A WRITTERK OR N CHANGE ORDER AS LAND OWNER(THOUGH TREP IRESENTTATED )TIVE,LOCAL TE THE OWNER, LEPHOJECTN E COMPANY,COMPANY,TOWER TERIALS WHICH ARE A. CONSTRUCTION.SUR STAKES AND SET ELEVATION STAKES PRIOR TO ANY cn O ❑ O U ERECTION FOREMAN(IF SUBCONTRACTED). U cc LL 19 ~ lr ANY WORK NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE DESCRIBED AND APPROVED BY THE OWNER SHALL PLACE FULL Cr W TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR B. GRUB THE COMPLETE ROAD AND SITE AREA AS REQUIRED PRIOR TO W LL ❑W 0 0 l9 INDICATED ON THE CONSTRUCTION DRAWINGS.ANY SUCH DISCREPANCY IN D. CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT in O LL Z FOUNDATION CONSTRUCTION OR PLACEMENT OF BACKFILL OR SUB-BASE W Z Q F- DIMENSION WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER COMMUNICATIONS,SUCH AS A MOBILE PHONE OR A BEEPER THIS U) 0 FOR CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE I.7 RELATED DOCUMENTS AND COORDINATION EQUIPMENT WILL NOT BE SUPPLIED BY THE OWNER.NOR WILL WIRELESS MATERIAL � (n j V 0 WORK IN THE AFFECTED AREAS. SERVICE BE ARRANGED. U) (/) Z A. GENERAL NOTES,CIVIL,STRUCTURAL,ELECTRICAL AND ANTENNA DRAWINGS C. CONSTRUCT TEMPORARY CONSTRUCTION ZONE ALONG ACCESS DRIVE.IN (I) Q ARE INTERRELATED.IN PERFORMANCE OF THE WORK;THE CONTRACTOR ACCORDANCE WITH ALL LOCAL STATE 4 FEDERAL RULES. I B. THE BIDDER,IF AWARDED THE CONTRACT,WILL NOT BE ALLOWED ANY EXTRA MUST REFER TO ALL DRAWINGS.ALL COORDINATION TO BE THE E. DURING CONSTRUCTION.CONTRACTOR MUST ENSURE THAT EMPLOYEES 0 COMPENSATION BY REASON OF ANY MATTER OR THING CONCERNING RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS WEAR HARD HATS AT ALL TIMES.CONTRACTOR WHICH SUCH BIDDER MIGHT HAVE FULLY INFORMED THEMSELVES PRIOR TO WILL COMPLY WITH ALL SAFETY REQUIREMENTS IN THEIR AGREEMENT. D. THE SITE AREA WILL BE BROUGHT TO SUB-BASE COURSE ELEVATION AND THE THE BIDDING. ACCESS ROAD TO BASE COURSE ELEVATION PRIOR TO FORMING 1.8 SHOP DRAWINGS FOUNDATIONS. F. PROVIDE WRITTEN DAILY UPDATES ON SITE PROGRESS TO THE OWNER VIA C. NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST,OR OF DIFFICULTIES E-MAIL OR CONDITIONS THAT MAY BE ENCOUNTERED OR Of ANY OTHER RELEVANT A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND USTED IN E. IF REQUIRED.GRADE,SEED,FERTILIZE AND MULCH DISTURBED AREAS O N v) h. I) MATTER CONCERNING THE WORK TO BE PERFORMED IN THE EXECUTION OF THESE SPECIFICATIONS TO THE OWNER FOR APPROVAL IMMEDIATELY AFTER BRINGING THE SITE AND ACCESS ROAD TO BASE COURSE 2 o O O 0 0 G. COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS THE WORK WILL BE ACCEPTED A5 AN EXCUSE FOR ANY FAILURE OR ELEVATION.WATER TO ENSURE GROWTH. ��Lt, REQUIRED PRIOR TO START Of CONSTRUCTION. �� �l OMISSION ON THE PART Of THE CONTRACTOR TO FULFILL EVERY DETAIL OF _�. /A, ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE B. ALL SHOP DRAWINGS PROVIDED BY THE CONTRACTOR WILL BE REVIEWED BY Vi`\- �•Y••['`A/� �. THE OWNER AND RETURNED TO THE CONTRACTOR WITH REDUNE F. REMOVE GRAVEL FROM TEMPORARY CONSTRUCTION ZONE. O WORK H. NOTIFY THE OWNERJPROJECT MANAGER IN WRITING NO LESS THAN 48 — • • • COMMENTS.THE CONTRACTOR WILL UPDATE THE DRAWINGS WITH ALL — REQUESTED CHANGES.THE CONTRACTOR MAY NOT USE ANY SHOP HOURS IN ADVANCE OF CONCRETE POURS.TOWER ERECTIONS,AND r •. i 1.3 CONTRACTS AND WARRANTIES DRAWING UNTIL A WRITTEN FINAL APPROVAL HAS BEEN PROVIDED BY THE EQUIPMENT CABINET PLACEMENTS. I.6 SUBMITTALS .. O: /6.1(��}E�p�� •4 . - F .i WLIJJNV'44 OWNER Q• ...REGISTERED •....."Z r/ I. CLOSEOUT PACKAGE IS DUE COMPLETE WITH DETAILED TOP PHOTOS UPON A. BEFORE CONSTRUCTION �L A. CONTRACTOR S RESPONSIBLE FOR APPLICATION AND PAYMENT OF ; • J CONTRACTOR UCENSES AND BONDS. 1.9 PRODUCTS AND SUBSTITUTIONS SITE PUNCHWALK WITH PROJECT MANAGER(SEE PROJECT MANAGER FORY SAMPLE CLOSEOUT PACKAGE). I I. FOR LANDSCAPING REFER TO THE SITE PLAN AND DETAILS AND • PRQFESSCQNAL = B. SEE MASTER CONSTRUCTION SERVICES AGREEMENT FOR ADD'L DETAILS. A. SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION.IN EACH PROVIDE A LANDSCAPING PLAN WITH COST ESTIMATE.(IF REQUIRED) I.12 INSURANCE AND BONDS ENGlNEEfi .e REQUEST IDENTIFY THE PRODUCT OR FABRICATION OR INSTALLATION d r METHOD TO BE REPLACED BY THE SUBSTITUTION.INCLUDE RELATED 2. SUBMIT FOR APPROVAL THE SPECIFICATIONS OF THE PROPOSED ,I1 4r I.4 STORAGE SPECIFICATION SECTION AND DRAWING NUMBERS AND COMPLETE A. CONTRACTOR SHALL AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE SURFACE COURSE MATERIAL. / M� M DOCUMENTATION SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR DURATION OF THE PROJECT ALL INSURANCE AS REQUIRED AND USTED AND / _ ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A MANNER SUBSTITUTIONS. SHALL NOT COMMENCE WITH THEIR WORK UNTIL THEY HAVE PRESENTED AN B. AFTER CONSTRUCTION THAT DOES NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK ANY ORIGINAL CERTIFICATE OF INSURANCE STATING ALL COVERAGE TO THE 'III. ���A,` 0,�~~ STORAGE METHOD MUST MEET ALL RECOMMENDATIONS Of THE ASSOCIATED B. SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY OWNER.REFER TO THE MASTER AGREEMENT FOR REQUIRED INSURANCE MANUFACTURER INDICATE AND D6CiUBE THE ITEMS,PRODUCTS AND MATERIALS BEING OMITS. I. PROVIDE LANDSCAPING WARRANTY STATEMENT,IF REQUIRED. INSTALLED.THE CONTRACTOR SHALL,IF DEEMED NECESSARY BY THE FIRE STATION RL 1.5 CLEAN UP OWNER SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN UEU B. THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL WARRANTY OF CUT SHEETS. POLICIES. CH37-975C A. THE CONTRACTORS SHALL AT ALL TIMES KEEP THE SITE FREE FROM RAW LAND ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR I.1 0 QUALITY ASSURANCE C. CONTRACTOR MUST PROVIDE PROOF OF INSURANCE. 599 S McLean Blvd. EMPLOYEES AT WORK AND AT THE COMPLETION OF THE WORK.THEY SHALL Elgin,IL 60120 SHEET TITLE: GENERAL NOTES 02004 TRANSCEND-NIKE COPP ALL RIGHTS RESERVED SHEET NUMBER: GN1.1 FOUNDATION PLAN WALL SECTION 'SCALE: NTS SCALE: NTS :�; ■ Mobile ■ ■ obile 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 Tel 773-444-5400 y Fax 773-444-5521/ CUT STONE CAP T/WALL 823'-0" / . A rC,l� I� #5 @ 12"O.C. MI MilTranscend-Nike Corporation 2112 W.GALENA BLVD.STE.8-188 b J _ AURORA,IL 60506 -I� IO"WALL = 6"CMU+4"BRICK FAX. 0 888-12 82 El tlin ® TNC PROJECT NUMBER 817 a I T/FOUND 81 5'-a' :II 1— FINISHED GRADE EL.81 4'-9" ka l',7 inc. 1 ilL ii CONSULTING ENGINEERS 406 Meadow Ridge -- I - - Prospect Herghts,IL 60070 II I I -- --0" Tel.(847)670-7413 1Z Fax:(847)670-7434 2#5 TOP 4 BTM S E-Mail:kamryeng.com 4"0 PVC DRAIN PIPE(TYP) \ CP r _/ ____1- F., to Tr o 0 cr 0 -- 2"X 4'CONST.KEYEl ~ rn Q c1 — O N \I w w CrLt1 z © © 5 W d F 1.11 W ® ., RETAINING WALL SECTION p IY 5 o -i ccc Al. LU Tn FOOTING \ r SCALE: NTS a me Er o I Y N N re cr o m 0 O 0_ fA LL p 0 W m — .►_ 10 O a D u- Z O 2 W CUT STONE CAP CO In = O Z FOOTING — U) _ V T/WALL 823'-C' O MIME ,© MEE #5@32"O.C. IMP -- r J -- 011 f IF _ Z o 0 o a o b d� ����tiC\ 1 0"WALL >(,�►.,.'•..k���t‘ ~"'C'K Y. B�'ti: — v I I 1 G CMU+4"BRICK m. s �v .....Q..�_I �Q\•:......•.• 4,,1It L_ J + L_ J CO ;��'�081-004042. d'f Q�+�' 062-033842 ;9?•,r' v FOUND 5I 5'-a' — 1_ ;" •REGISTERED J� f REGISTERED y// STRUCTURAL i / •: 00 i PRGFESSIGNAL . i ' 1a' } 'r*' OGINEER /,*t ENGINEER */ r zs-a' #5@ 12' � S= ���:.'•. h11�LIN0�5w'" GRADE e;col i1�`ot� y EXISTING GROUND EL. Co FIRE STATION RL SEE DWG C I.I - 2-0' CH37-975C _-- RAWLAND n \ FT 599 S McLean Blvd. PROVIDE 4-4"0 PVC DRAIN PIPESAT Elgin,IL 60120 EAST,NORTH,AND SOUTH WALLS SPACED EQUALLY SHEET TITLE: �' 4" 2-4" —� FOUNDATION #5@ 12" PLAN 1 / •. - 6#5 O 2004 TRANSCEND-NIKE CORP ALL RIGHTS RESERVED SHEET NUMBER: 4'-6" 1 S2.1 I T . •N .obf y 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 Tel 773-444-5400 I ,/o Fax 773-444-5521 l0 REQUIRED.USE OF EROSION CONTROL MESH OR MULCH NET WILL BE AN B. FABRIC SHALL BE SIX FEET HIGH 3.3 PROTECTION:UPON COMPLETION OF ERECTION,INSPECT ITI II 3 IXUVATION(CONTINUED) ACCEPTABLE ALTERNATE. (VERIFY WIPROJECT MANAGER)TWO INCHES CHAIN UNK MESH OF NO.9 FENCE MATERIAL AND PAINT FIELD CUTS OR GALVANIZING BREAKS - GAUGE(0.I48")WARE.THE FABRIC SHALL HAVE A KNUCKLED FINISH FOR THE WITH ZINC-BASED PAINT COLOR TO MATCH THE GALVANIZING TOP AND BOTTOM EDGES,FABRIC SHALL CONFORM TO THE SPECIFICATIONS PROCESS. i tv 7, 3.3 INSTALLATION(AS REQUIRED) B. ALL TREES PLACED IN CONJUNCTION WITH A LANDSCAPE CONTRACT WILL BE OF ASTM A-392 CLASS I. WRAPPED,TIED WITH HOSE PROTECTED WIRE AND SECURED TO 2 INCHES X 2 INCHES X 4 FEET STEEL ANGLE EXTENDING TWO FEET INTO THE GROUND ON SPECIAL CONSTRUCTION A. THE SITE AND TURNAROUND AREAS SHALL BE AT THE SUB-BASE COURSE FOUR SIDES OF THE TREE. C. ALL POSTS SHALL BE SCHEDULE 40 GALVANIZED Transcend-Nike Corporation ELEVATION PRIOR TO FORMING FOUNDATIONS.GRADE OR FILL THE SITE AND STEEL PIPE AND SHALL BE TYPE I ASTM A-I 28 AND OF THE FOLLOWING TOWER.*ANTENNA INBTAl1ATION 2112 W.GALENA BLVD.STE.8-188 ACCESS ROAD AS REQUIRED WITH THE SOIL RESULTING FROM EXCAVATING C. ALL EXPOSED AREAS SHALL Be PROTECTED AGAINST WASHOUTS AN SOIL DIAMETER(OD PER FENCE INDUSTRY STANDARD). AURORA,IL 80508 THE FOUNDATIONS(PROVIDE EVEN DISTRIBUTION).THE ELEVATIONS ARE TO EROSION. BE X'OI CULATED FROM THE RESULTING GRADE. UNE 1-7/8 INCHES PART I-GENERAL TEL.830-888-1281 CORNER 3 INCHES FAX.83P888-1282 B. CLEAR EXCESS SPOILS,IF ANY,FROM JOB SITE AND DO NOT SPREAD PACE OP REQUIRED) GATE 3 INCHES 1.I WORK INCLUDED TNC PROJECT NUMBER:617 BEYOND THE UMITS OF THE OWNERS LEASE PROPERTY UNLESS AUTHORIZED BY PROJECT MANAGER,IN WRITING. PART I-GENERAL D. ALL TOP AND BRACE RAILS SHALL BE I I/4'DIAMETER SCHEDULE 40, A. INSTALL ANTENNAE AS INDICATED ON DRAWINGS AND OWNER MECHANICAL-SERVICE PIPE.FRAMES SHALL HAVE WELDED CORNERS. SPECIFICATIONS. k^„yam �' inc. C. THE ACCESS ROAD SHALL BE BROUGHT TO BASE COURSE ELEVATION PRIOR 1.1 WORK INCLUDED:REFER TO THE SITE PLANS FOR SIZE AND LOCATION OF a���J�/ 11 TO FOUNDATION CONSTRUCTION. FENCE AND GATES TO BE INSTALLED. E. GATE FRAMES SHALL HAVE A FULL-HEIGHT VERTICAL BRACE AND A FULL- B. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON CONSULTING ENGINEERS WIDTH HORIZONTAL BRACE,SECURED IN PLACE BY USE OF GATE BRACE DRAWINGS. D. AVOID CREATING DEPRESSIONS WHERE WATER MAY POND. I.2 RELATED WORK CLAMPS. 406 Meadow Ridge C. INSTALL FURNISHED GALVANIZED STEEL WAVEGUIDE LADDER OR Prospect HegMs,IL 6C1070 E. THE CONTRACT INCLUDES ALL NECESSARY GRADING.BANKING,DITCHING A. COORDINATE FENCE GROUNDING WITH ELECTRICAL SUBCONTRACTOR. F. GATE HINGES SHALL BE MERCHANTS METAL MODEL 64386 HINGE ADAPTER WITH ATTACHMENT DEVICE. Tel.(847)870.7413 AND UNLESS OTHERWISE INDICATED,COVERING UP TO SIX INCHES OF MODEL 6409,188 DEGREE ATTACHMENT,OR EQUAL. Fax:(847)870.7434 SURFACE COURSE.ALL ROADS OR ROUTES UTILIZED FOR ACCESS TO THE B. REFER.TO CONCRETE SPECIFICATIONS FOR DETAILS OF CONCRETE AND D. INSTALL WAVEGUIDE BRIDGE AND CABLE ATTACHMENTS AS INDICATED SITE,COMMENCING AT THE POINT OF INTERSECTION WITH THE NEARESTE-Mall:kamlyBDg.Com GROUT. G. THE GUIDE(LATCH ASSEMBLY)SHALL BE MERCHANTS METAL MODEL 2083.OR ON DRAWINGS. PUBUC THOROUGHFARE,ARE INCLUDED IN SCOPE UNLESS OTHERWISE EQUAL NOTED. 1.3 QUALITY ASSURANCE E. SUPPLY AND INSTALL ONE ISOLATED GROUND BAR AT LOCATIONS H. LATCHES.STOPS AND KEEPERS SHALL BE PROVIDED FOR ALL GATES. INDICATED ON GROUNDING PLAN. N F. WHEN IMPROVING AN EXISTING ACCESS ROAD.GRADE THE EXISTING ROAD F W F R p 9 O 9 TO REMOVE ANY ORGANIC MATTER AND SMOOTH THE SURFACE BEFORE A. ALL STEEL MATERIALS UTILIZED IN CONJUNCTION WITH THIS SPECIFICATION Q N .11 IX) 0) PLACING FILL OR STONE. WILL BE GALVANIZED OR STAINLESS STEEL.WEIGHT OF ZINC COATING ON I. ALL STOPS SHALL HAVE KEEPERS CAPABLE OF HOLDING THE GATE LEAF IN THE F. SUPPLY AND INSTALL GROUNDING STRAP KITS WITH LONG BARREL 0CV X.IQ , uj, THE FABRIC SHALL BE NOT LESS THAN 12 OUNCES PER SQUARE FOOT OF OPEN POSITION. COMPRESSION LUGS(SIM.TO ANDREW-223700TBD OR APPROVED G. PLACE FILL OR STONE IN SIX INCHES MAXIMUM LIFTS AND COMPACT BEFORE MATERIAL COVERED.POSTS SMALL BE HOT-DIPPED IN GRADE E ZINC.1.8 EQUAL)AT TOWER BASE BEFORE ENTERING THE EQUIPMENT. PLACING NEXT LIFT. OUNCES PER SQUARE FOOT. J. DOUBLE GATES SHALL HAVE A FULL HEIGHT PLUNGER BAR WITH DOME CAP. GROUNDING STRAPS TO BE CONNECTED TO ISOLATED GROUND BAR. JJJ 1- H. THE FINISH GRADE,INCLUDING TOP SURFACE COURSE.SHALL EXTEND A I.4 SEQUENCING K. A NO.9 GAUGE ZINC COATED TENSION WIRE SHALL BE USED AT THE BOTTOM OF G. ASSIST OWNER TECHNICIANS IN PERFORMING SWEEP TEST OF 3 MINIMUM OF ONE FOOT BEYOND THE SITE FENCE AND SHALL COVER THE THE FABRIC,TERMINATED WITH BAND CUPS AT CORNER AND GATE POSTS. INSTALLED COAX. W Q' Z AREA AS INDICATED. A. IF THE SITE AREA HAS BEEN BROUGHT UP TO SURFACE COURSE ELEVATION W d I- W PRIOR TO FENCE CONSTRUCTION,FENCE POST EXCAVATION SPOILS MUST L PLACE A SIX IrJGYI BY 1/2 INCH DIAMETER EYE-BOLT TO HOW TENSION WIRE AT 1.2 REQUIREMENTS OF REGULATORY AGENCIES LU w ZO MI IX I. RIPRAP SHALL BE APPUED TO THE SIDE SLOPES OF ALL FENCED SITE AREAS, BE CONTROLLED TO PRECLUDE CONTAMINATION OF SAID SURFACE COURSE. UNE POSTS. F 0 S_ EE Q I U) cn PARKING AREAS SAND TO ALL OTHER SLOPES GREATER THAN 2:I WHEN I.5 SUBMITTALS A. SFUTALL IN CONFORMANCE WITH U.L.ISH U.L.USTED EQUIPMENT STANDARDS WHERE APPLICABLE. R'ERE SUCH LABELS AVAILABLE. a. O) O O . U M. STRETCHER BARS SHALL BE 3/16 INCH BY 3/4 INCH OR HAVE EQUIVALENT 0 LL c0 Lu CROSS SECTIONAL AREA. N t) IY J. RIPRAP SHALL BE APPUED TO THE SIDES OP DITCHES OR DRAINAGE SWALES A. MANUFACTURER'S DESCRIPTIVE UTERATURE. B. INSTALL ANTENNA.ANTENNA CABLES AND GROUNDING SYSTEM IN W O W 0 C) (1] AS INDICATED ON PLANS. ACCORDANCE WITH DRAWINGS AND SPECIFICATION IN EFFECT AT a OD U- O O. ALL CORNER GATE AND END PANELS SHALL HAVE A 3/8 INCH TRUSS ROD WITH W U) a B. CERTIFICATE OF COMPLIANCE THAT SPECIFICATIONS HAVE BEEN MET. TURNBUCKLES. PROJECT LOCATION AND IN COMPLIANCE WITH RECOMMENDATIONS W I W OF STATE AND 1 XX-AI BUILDING CODES,SPECIAL CODES HAVING U) : C.) 0 K. RIPRAP ENTIRE DITCH FOR SIX FEET IN ALL DIRECTIONS AT CULVERT JURISDICTION OVER SPECIFIC PORTIONS OF WORK.THIS INCWDES OPENINGS. cn I.6 APPLICABLE STANDARDS P. ALL POSTS EXCEPT GATE POSTS SHALL HAVE A COMBINATION CAP.GATE POSTS BUT IS NOT LIMITED TO SECTION 1.3 BELOW. - _ SHALL HAVE A DOME CAP. 0 L SEED,FERTILIZER AND STRAW COVER SHALL BE APPLIED TO ALL OTHER ASTM-A 120 SPECIFICATION FOR PIPE,STEEL BLACK AND HOT-DIPPED 1.3 APPLICABLE STANDARDS DISTURBED AREAS AND DITCHES,DRAINAGE,SWAlES,NOT OTHERWISE ZINC COATED(GALVANIZED)WELDED AND SEAMLESS FOR ORDINARY Q. OTHER HARDWARE INCLUDES BUT MAY NOT BE LIMITED TO TIE CUPS.BAND WRAPPED. USES. CUPS AND TENSION BAND CUPS. A. EIA-ELECTRONIC INDUSTRIES ASSOCIATION EIA-22-F. M. UNDER NO CIRCUMSTANCES WILL DITCHES,SWALES OR CULVERTS BE STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA PLACED 50 THEY DIRECT WATER TOWARDS,OR PERMIT STANDING WATER ASTM-A 123 ZINC(HOT-DIP GALVANIZED)COATING ON IRON AND STEEL R. ALL CAPS SHALL BE CAST STEEL SUPPORTING STRUCTURES. O .- N Pf a N IMMEDIATELY ADJACENT TO SITE.IF DESIGNS OR ELEVATIONS CONFLICT WITH PRODUCTS. Z 00 0 0 0 THIS GUIDANCE ADVISE THE OWNER IMMEDIATELY,IN WRITING. PART 3 EXECUTION B. FAA-FEDERAL AVIATION ADMINISTRATION ADVISORY �`..\��` ASTM-A 153 STANDARD SPECIFICATION FOR ZINC COATING(HOT-DIP)ON CIRCULAR AC 7017460-1H,OBSTRUCTION MARKING AND UGHTING. ��\���. apt, IRON AND STEEL HARDWARE. N. IF DITCH UES WITH SLOPES GREATER THAN TEN PERCENT,MOUND 3.1 INSPECTION:EXCAVATE POST HOLES PER CONSTRUCTION .� • •NAa{ DIVERSIONARY HEADWALLS IN THE DITCH AND RIPRAP THE UPSTREAM SIDE DOCUMENTS.CONFIRM PROPER DEPTH AND DIAMETER OF POST HOLE C. FCC-FEDERAL COMMUNICATIONS COMMISSION RULES AND •••••••••• 1, OF THE HEADWALL AS WELL A5 THE DITCH POR SIX FEET ABOVE THE CULVERT ASTM-A392 SPECIFICATION FOR ZING-COATED STEEL CHAIN UNK FENCE EXCAVATIONS. REGULATIONS FORM 715,OBSTRUCTION MARKING AND UGHTING r Q�•/•1�•� •�J_! ENTRANCE. FABRIC. SPECIFICATIONS FOR ANTENNA STRUCTURES AND FORM 715A,HIGH u• 062 �• �. INTENSITY OBSTRUCTION UGHTING SPECIFICATIONS FOR ANTENNA I-4„;i • ✓��I 3.2 INSTALLATION STRUCTURES. #4'• � •/'r O. SEED AND FERTILIZER SHALL BE APPUED TO SURFACE CONDITIONS WHICH ASTM-A49I SPECIFICATION FOR ALUMINUM-COATED STEEL CHAIN UNK • • e WILL ENCOURAGE ROOTING.RAKE AREAS TO BE SEEDED TO EVEN THE FENCE FABRIC. • i A. POST FOUNDATIONS SHALL HAVE A MINIMUM SIX-INCHES CONCRETE Pe PROFESSIONAL SURFACE AND LOOSEN THE SOIL. D. AISC-AMERICAN INSTITUTE OF STEEL CONSTRUCTION Pi'{�,�r•Ia�IONAt. COVER,UNDER POST SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 ASTM-A525 STANDARD SPECIFICATION FOR STEEL SHEET ZINC COATED l L'�lnill�ti•A T� P. SOW SEED IN TWO DIRECTIONS IN TWICE THE QUANTITY RECOMMENDED BY (GALVANIZED)BY THE HOT-DIPPED PROCESS. BOLTS. G7YU►f�GGil THE SEED PRODUCER. OP B. ALL FENCE POSTS SHALL BE VERTICALLY PLUMB WITHIN ONE INCH IN OF ow EIGHT FEET. E. CITY OF CHICAGO ELECTRIC CODE.2000-ON TOWER !VI _r ASTM-A570 SPECIFICATION FOR HOT-ROLLED CARBON STEEL SHEET LIGHTING KITS. Q. 1715 THE CONTRACTOR'S RfSPON5IBIUTY TO ENSURE GROWTH OF SEEDED AND STRIP STRUCTURAL QUALITY. C. AT CORNER POSTS,GATE POST AND SIDES OF GATE FRAME,FABRIC '�`,L +Np�S -M AND LANDSCAPED AREAS BY WATERING UP TO THE PONT OF RELEASE FROM SHALL BE ATTACHED WITH STRETCHER AND TENSION BAND-CUPS AT THE CONTRACT.CONTINUE TO REWORK BARE AREAS UNTIL COMPLETE ASTM�585 SPECIFICATION FOR ALUMINUM COATED STEEL BARBED 15 INCH INTERVALS. F. UL-UNDERWRITER'S LABORATORIES APPROVED ELECTRICAL ` M:W.04 COVERAGE IS OBTAINED. 11I� PRODUCTS. 3.4 FIELD QUALITY CONTROL D. AT UNE POSTS.FABRIC SHALL BE ATTACHED WITH BAND-CUPS AT 15 G. IN ALL CASES,PART 77 OR THE FAA RULES AND PARTS 17 FIRE STATION RL FEDERAL SPECIFICATION RR-F-191-FENCING.WIRE AND POST METAL INCH INTERVALS. AND 22 OP THE FCC RULES ARE APPLICABLE AND IN THE EVENT OP (AND GATES,CHAIN UNK FENCE FABRIC AND ACCESSORIES). CONFLICT,SUPERSEDE ANY OTHER STANDARDS OR SPECIFICATIONS. CH37-975C A. COMPACTION SHALL BE 90%MAXIMUM DENSITY IN ACCORDANCE WITH E. ATTACH FABRIC TO BRACE RAILS,TENSION WIRE AND TRUSS RODS RAWLAND ASTM 0.1557 FOR SITE WORK AND 95%UNDER SLAB AREAS.AREAS OF PART 2-PRODUCTS WITH TIE CUPS AT TWO FOOT INTERVALS. SETTLEMENT WILL BE EXCAVATED AND REFILIED AT CONTRACTOR'S EXPENSE. H. LIFE SAFETY CODE NPPA-101. 599 S McLean Blvd. 2.1 FENCE MATERIAL F. A MAXIMUM GAP OF TWO INCHES WILL BE PERMITTED BETWEEN THE Elgin,IL 60120 3.5 PROTECTION CHAIN LINK FABRIC AND THE FINAL GRADE. A. ALL FABRIC WIRE,RAILS,POLES.HARDWARE AND OTHER STEEL MATERIALS SHEET TITLE: A. PROTECT SEEDED AREAS FROM EROSION BY SPREADING STRAW TO A SHALL BE HOT-DIPPED GALVANIZED. G. CONCRETE FOR FENCE POSTS SHALL HAVE A MINIMUM OF 3000 PSI UNIFORM LOOSE DEPTH OF 1-2 INCHES,STAKE AND TIE DOWN AS BREAKING STRENGTH AT 28 DAYS. GENERAL NOTES •2004 TRANSCEND-NIKE CORP ALL RIOMS RESERVED SHEET NUMBER: GN1.2 I T • Mobile• • 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631 • Tel 773-444-5400 23. METER SOCKET AMPERES,VOLTAGE.NUMBER OF PHASES SHALL BE A5 D. ABOVE GRADE CONNECTIONS SHALL BE BURNDY HYGROUND ALL rr MONOPOLES SHALL HAVE TWO GROUND RODS(MINIMUM). Fax 773-444-5521 ly GENERAL ELECTRIC NOTED ON THE DRAWINGS,MANUFACTURED BY"SQUARE D COMPANY",OR COMPRESSIONOR APPROVED EQUAL BELOW GRADE CONNECTIONS ALL OTHER TOWERS SHALL HAVE ONE GROUND ROD PLACED AT APPROVED EQUAL WELDING SYSTEM SHALL BE CADWELD OR OTHER APPROVED EXOTHERMIC THE BASE OF EACH TOWER LEG.EACH MONOPOLE OR TOWER LEG ^ FOR BONDING AS SPECIFIED. CALL BE BONDEDTHE SYSTEM VIA#2 BARE TINNED SOUD Mri- I `X GENERAL ELECTRICAL PROVISION COPPER CONDUCTORS. ORR EXOTHERMICALLYS.EXOTHERMICALLY WELD THE l�K 24. ALL MATERIALS SHALL BE U.L LISTED. CONDUCTORS TO ONLY STRUCTURAL BASE PLATES OR LUGS OR E. XIT OR ADVANCED GROUNDING ELECTRODE(AGE),ALL CHEMICAL GROUND EARS AS MAY BE PROVIDED.NO CONNECTIONS SHALL BE MADE I. SUBMITTAL OF BID INDICATES CONTRACTOR 15 COGNIZANT OF AU. RODS SHALL BE UL APPROVED. JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER THIS 25. CONDUIT TO THE VERTICAL WALLS OF THE STRUCTURE.NEVER GROUND TO CONTRACT. ES 'X HOLLOW LEG MEMBERS. •.".` �. A. RIGID CONDUIT SHALL BE U.L LABEL GALVANIZED ZINC COATED F. SOLID COPPER PLAT OF MINIMUM 33'X I/4"SIZE AS SPECIFIED. Transcend-Nike CorporationWITH ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER 3.7 COAX GROUNDING:SHALL2. CONTRACTOR SHALL PERFORM ALL VERIFICATIONS,OBSERVATION CONCRETE SLABS IN CONTACT WITH THE EARTH,UNDER PUBUC ROADWAYS, G. NOALOX OR APPROVED EQUAL CONDUCTIVE MEDIUM MATERIAL SHALL BE 2112 W.GALENA BLVD.SEE.&188 TESTING AND EXAMINATION WORK PRIOR TO THE ORDERING OF THE IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR,RIGID CONDUIT IN USED IN ALL MECHANICAL CONNECTIONS. AURORA,IL 60506 ELECTRICAL EQUIPMENT AND PERFORMING THE ACTUAL EACH ANTENNA COAXIAL CABLE SHALL TYPICALLY BE GROUNDED CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP CONSTRUCTION.CONTRACTOR SHALL ISSUE A WRITTEN NOTICE OF PROCESS NO.3 AT THREE POINTS USING A COAXIAL CABLE KIT FROM THE TEL 630-688-1281 ALL CONDITIONS TO THE OWNER USTING ALL MALFUNCTIONS, H. f6 AWG STRANDED INSULATED(GREEN)FOR ALL INTERNAL EQUIPMENT MANUFACTURER OF THE ANTENNA CABLE.A TYPICAL INSTALLATION FAX.630-688-1282 FAULTY EQUIPMENT AND DISCREPANCIES. GROUNDING. SHALL BE AS FOLLOW`: INC PROJECT NUMBER:617 B. ELECTRICAL METAWC TUBING SHALL HAVE U.L.LABEL,FITTING 3. HEIGHTS SHALL BE VERIFIED WITH CONTRACTOR PRIOR TO AND SHALL BE GLAND RING COMPRESSIONTYPE.EMT SHALL BE USED ONLY FOR I. MECHANICAL FASTENERS(I.E.,DOUBLE LUGS,SPOT BOLTS PARALLEL A. THE FIRST GROUND CONNECTION SHALL OCCUR 12 INCHES FROM AFTER ALL INSTALLATIONS. INTERIOR RUNS. CONNECTORS)SHALL BE BRONZE,BRASS,COPPER OR STAINLESS STEEL THE MAIN COAX TERMINATION.THIS GROUND SHALL TERMINATE AND HAVE NOALOX BETWEEN CONDUCTOR AND CONNECTION. ON THE TOP AGB. kam�? inc 4. THESE PLANS ARE DIAGRAMMATIC ONLY,FOLLOW AS CLOSELY AS C. FLEXIBLE HEEHAWS CONDUIT SHALL HAVE U.L LISTED LABEL AND J POSSIBLE. MAY BE USED WHERE PERMITTED BY CODE. J. BOLTS,NUTS AND SCREWS USED TO FASTEN MECHANICAL CONNECTORS B. THE SECOND GROUND SHALL BE MADE AT THE BOTTOM OF THE CONSULTING ENGINEERS SHALL BE STAINI F5s STEEL WITH STAR TYPE STAIN'PCS STEEL LOCK VERTICAL RUN OF THE COAXIAL CABLE A5 IT TURNS OUT AWAY 406 Meadow Ridge 5. ELECTRICAL SERVICE SHALL BE 120/240 VAC SINGLE PHASE 3 WIRE D. PARALLEL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 WASHERS. FROM THE TOWER TOWARDS THE BTS.THISGROUND SHALL BE Prospect Heights,IL 60070 200 AMP SERVICE UNLESS OTHER WISE CONVEYED BY OWNER. (UNLESS NOTED OTHERWISE)AT A MINIMUM DEPTH OF 30'BELOW GRADE- TERMINATED AT THE GROUND BAR AT BASE OF TOWER.THE STACKED UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40(UNLESS K. ALL LUG TUBE FASTENERS SHALL PROVIDE TWO HOLES TO ALLOW A DOUBLE GROUND BAR SHALL HAVE TWO(2)LEADS OF#2 AWG BARE Tel.(847)670-7413 NOTED OTHERWISE)AT A MINIMUM DEPTH OF 24"BELOW GRADE. BOLT CONNECTION. TINNED SOUD COPPER WIRE,AND SHALL TERMINATE AT THE Fax(847)670-7434 G. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TOWER GROUND RING. E-Mail:kam a TAGGED IN EACH PANEL BOARD,PULL BOX,J-BOX,SWITCH BOX, ry Ggcom ETC.,IN COMPUANCE WITH OCCUPATIONAL SAFETY AND HEALTH ACT E. ABOVE GROUND CONDUIT SHALL BE P.V.C.SCHEDULE 80 3.2 MASTER GROUND BAR(MGB): (O.S.H.AJ. (UNLESS NOTED OTHERWISE). C. THE THIRD GROUND SHALL BE MADE PRIOR TO COAX ENTRY INTO BTS.THE GROUND WIRE SHALL BE TERMINATED AT MASTER THE PURPOSE OF THE MASTER GROUND BAR 15 TO GROUND THE MAIN GROUND BAR.THE MASTER GROUND BAR SHALL HAVE TWO(2) 7 27. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT ENGRAVED W '7 O 7. CONTRACTOR SMALL PROVIDE ALL LABOR.MATERIALS,INSURANCE, PLASTIC LABELS. COAX AND ANY OTHER METAWC OBJECTS AROUND THE BTS. LEADS OF#2 AWG BARE TINNED SOUD COPPER WIRE,AND SHALL F O O O 4 9 EQUIPMENT,INSTALLATION,CONSTRUCTION TOOLS, TERMINATE AT THE TOWER GROUND RING. Q N N OJ TRANSPORTATION,ETC.,FOR A COMPLETE AND PROPERLY C x- IF AN MGB IC NOT PROVIDED WITH THE BTS.THE MGB SHALL BE AS N el 7 IQ OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED 28. COORDINATE THE ELECTRICAL SERVICE WITH THE UTILITY COMPANY,AND FOLLdY+S. ON DRAWINGS,A5 SPECIFIED HEREIN AND/OR AS OTHERWISE PROVIDE DAILY UPDATES TO PM UNTIL FINAL ELECTRICAL SERVICE IS THE MGB IS A COPPER BAR MEASURING 4"W x 24'L X I/4"LOCATED AS REQUIRED. EFFECTED. -.E CLOSE TO THE BTS 05 POSSIBLE.THE MGB SHALL HAVE A MINIMUM NUMBER OF 28 EACH 3/8"HOLES.GROUND BAR SHALL BE SUPPORTED BY 1- 8. ALL MATERIALS AND EQUIPMENT SMALL BE NEW AND IN PERFECT 29. UPON COMPLETION OF WORK,CONDUCT CONTINUITY,SHORT CIRCUIT,AND MOUNTING BRACKETS WITH INSULATOR STANDOFFS.(2)#2 TINNED SHALL CONDITION WHEN INSTALLED AND SMALL BE OF THE BEST GRADE FALL OF POTENTIAL GROUND TESTS FOR APPROVAL SUBMIT TEST REPORTS BE MECHANICALLY ATTACHED(2 HOLE COMPRESSION LUG 3/8'HOLES.I- W 3 W 2 Z AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS TO PROJECT MANAGER CLEAN PREMISES OF ALL DEBRIS RESULTING FROM CENTER TO CENTER SPACING)TO THE MGB AND DOWN LEADS THEN TAKEN 5 W It.' W W OR GROUP OF EQUIPMENT.MATERIALS SHALL BE LISTED"J"WHERE WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. THROUGH CONDUIT TO THE GROUND RING.THIS CONDUCTOR SMALL BE Z W 5 7 J W CC SUBJECT TO SUCH APPROVAL MATERIALS SHALL MEET WITH KEPT SEPARATE AND ISOLATED UNTIL TERMINATING AT THE MAIN 0 W ZZ W 0 EX APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GROUNDING PONT,(I.E. TERIOR GROUND RING OR BUILDING STEEL). F e cc Q 2 co GOVERNING BODIES HAVING JURISDICTION.MATERIALS SHALL BE 30. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR CONNECTIONCl. O Q OF TEMPORARY AND PERMANENT POWER TO THE SITE.THE TEMPORARY OJ O U MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS POWER AND ALL HOOKUP COSTS TO BE PAID BY CONTRACTOR. 3.3 ANTENNA GROUND BAR(AGB): U O c cc 0 m ~ ESTABLISHED BY ANSI,NEMA AND NBFU. LL W d LL Iw al GROUNDING STANDARDS THE PURPOSE OF THE ANTENNA GROUND BAR 15 PRIMARILY FOR UGHTNING 0 Op U. Z 0 9. ALL CONDUIT INSTALLED SHALL BE SURFACE MOUNTED OR DIRECT W I-• pROTECnON.COAXIAL CABLE 15 USUALLY THE ONLY ITEM GROUNDED TO co 0 BURIAL UNLESS OTHERWISE NOTED. 0 0) W 2 W 1.0 DEFINITIONS THIS BAR HOWEVER IT IC ACCEPTABLE TO BOND EXTERIOR CABLE TRAY, In C.)- 2 CB WAVE GUIDE PORTS AND CANTILEVERED WAVE GUIDE BRIDGES TO THE AGB. U) U) QZ 10. CONTRACTOR SHALL CARRY OUT THEIR WORK IN ACCORDANCE WITH co ALL GOVERNING STATE,COUNTY AND INX'41 CODES AND D.5.HA. AGB ANTENNA GROUND BAR I AWG AMFRICAN WIRE GAUGE. THE AGB 5 A COPPER BAR MEASURING 4'W X 24'L X I/4"ON WHICH THE 0 CAD WELDING:AN EXOTHERMIC WELDING PROCESS WHICH CREATES POSITIVE COAXIAL CABLE FROM THE ANTENNAS ARE PRIMARILY GROUNDED.THERE I I. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS CONTACT OF POSITIVE CONTACT OF GROUNDING CONDUCTORS SHALL BE TWO AGES,ONE LOCATED AT THE TOP OF THE TOWER AT THE AND PAY ALL REQUIRED FEES. EMT f1ECTRJUL METAL TUBING(LIGHT GAUGE METAL CONDUIT) START OF THE VERTICAL RUN OF COAX..THE OTHER AT THE BOTTOM OF ROC RIGID GALVANIZED CONDUIT,5CI7 40 OR HIGHER THE VERTICAL RUN OF COAX BEFORE IT MAKE ITS BEND.(IF THE TOWER 15 12. COMPLETE JOB SMALL BE GUARANTEED FOR A PERIOD OF ONE(I) PVC POLY VINYL CHLORIDE CONDUIT OVER 200 THERE SHALL BE A THIRD AGB LOCATED AT HE MIDDLE OF THE YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER. MASTERANY WORK, MOB GROUND BAR TOWER).THE AGB SHALL HAVE A MINIMUM OF 28 EACH 3/8'HOLES. C N CI 7 u'I MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT Rh RADIO FREQUENCY INTERFERENCE GROUND BARS SHALL BE SUPPORTED BY MOUNTING BRACKETS WITH z o O 0 0 O INSULATOR STANDOFFS.USE#2 AWG SOUD TINNED WIRE W/2�tOLE SHORT PERIOD SHALL BE CORRECTED AT ONCE.UPON WRITTEN THW LETTER TYPE DESIGNATION FOR CONDUCTOR INSULATION THAT IS A �t't� BARREL COMPRESSION LUGS 3/8'HOLES,I CENTER TO CENTER SPACING). �t NOTIFICATION.AT THE EXPENSE OF THE CONTRACTOR. MOISTURE AND HEAT RESISTANT THERMOPLASTIC WITH A MAXIMUM ti Z, THIS CONDUCTOR E SHALL BE KEPTUDINSEPG AND ISOLATEDEXTERIUNTIL / 0����t/ Y..j5���� OPERATING TEMPERATURE OF 75 DEGREES CELSIUS OR I67 DEGREES w S� O FAHRENHEIT. TERMINATING AT THE MAIN GROUNDING POINT(I.E.,EXTERIOR GROUND •� 13. ALL EMPTY CONDUITS SHALL HAVE A PULL WIRE OR ROPE. RING,OR BUILDING STEEL). - TA TENANT IMPROVEMENT is 14. PROVIDE OWNER WITH ONE SET OF COMPLETE ELECTRICAL"AS 3.4 GROUND ROD AND GROUND RING PLACEMENT: 1L • 062-033842 INSTALLED'DRAWINGS AT THE COMPLETION OF THE JOB,SHOWING 2.0 BACKGROUND ; : •':....• �j ACTUAL DIMENSIONS,ROUTINGS AND CIRCUITS. f ' REGISTERED f►I� THE OUTSIDE GROUND RING SHALL BE PLACED AROUND THE BTS AT A 2.2 A/C GROUNDING: e •' • DISTANCE OF TWO(2)FEET FROM THE BTS AT A DEPTH OF 3'-6'OR 6' .4 • PROFESSIONAL • >r 15. ALL BETC.,ROCHURES.SHALL OPERATING BE TURNEDVER TO THE OWNER P BELOW THE AT JOB IN THIS GROUNDING SYSTEM THE NC SERVICE GROUND SHALL BE KEPT A DEPTH SUCH TTJHAT THE TOP OF THE RODS 5 AT THELEVEL OF THE DRIVEN SHALL BE TO ]{j Y T ENGINEER COMPLETION. ISOLATED FROM THE EQUIPMENT FRAME WORK AND LIGHTNING PROTECTION GROUND RING CONDUCTOR.THE RODS SHALL BE PLACED ALONG THE RING irb GROUND SYSTEMS EXCEPT FOR ONE SPECIFIC PONT.THIS POINT 15 THE AT THE FOLLOWING LOCATIONS: I 6. USE T-TAP CONNECTIONS ON ALL MULTI-CIRCUITS WITH COMMON o. MAIN GROUNDING POINT OF THE SYSTEM.THIS WOULD TYPICALLY BE �.- NEl1TRAL CONDUCTOR FOR LIGHTING FIXTURES. CONNECTING THE NC SERVICE GROUND AT THE COMMERCIAL POWER RISER A. ow BELOW THE AREA OF THE INTERNAL MASTER GROUND r)/�� POLE DISCONNECT/METER BASE TO THE EXTERNAL GROUND RING.ALLBAR(MGB)FOR CONNECTION TO THE AGB. ✓`11r O •V GROUNDING CONNECTIONS INSIDE OF CABINETS SHALL BE SCRAPED TO �� 1 NAMR_r ~~ 17. ALL CONDUCTORS SHALL BE COPPR BARE METAL AND COATED WTTH NOALOX. B. NEAR THE CORNERS OF THE BTS. 18. AU.CIRCUIT BREAKERS,FUSES AND ELECTRICAL EQUIPMENT SMALL 3.0 STATION GROUNDING SYSTEM FIRE STATION RL HAVE AN INTERRUPTING SHORT CIRCUIT CURRENT TO WHICH THEY C. A5 REQUIRED TO ACHIEVE A MAXIMUM SPACING OF TEN MAY BE SUBJECTED,AND A MINIMUM OF 22,000 K.A.I.C. (10)FEET BETWEEN GROUND RODS ALONG THE RING PERIMETER. CH37-975C 3.1 MATERIALS: RAW LAN D 19. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS A. 12 AWGWIRES BARE SOLID TINNED COPPER TO BE USED FOR ALL EXTERIOR D. A5 REQUIRED ALONG THE RING PERIMETER TO ACHIEVE 599 S McLean Blvd. REQUIRED BY ALL APPLICABLE CODES. CONDUCTORS AND TOWERGROUND BAR CONDUCTORS OR AS OTHERWISE 10 OHMS OR LESS RESISTANCE WHEN TESTE Elgin,IL 60120 SPECIFIED..OROUNDS TO THE LNAS SHALL BE NO.6 STANDARD GREEN 20. PATCH,REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN INSULATED JUMPERS.THE GROUND WIRE TO THE MGB SHALL BE GREEN E. ONE ROD LOCATED AT EACH TOWER LEG OR TWO RODS ON THE COURSE OF THE ELECTRICAL WORK. JACKETED STRANDED#2 TINNED WIRE BURNOY CONNECTED TO THE BUSS OPPOSITE SIDE FOR MONOPOLES. SHEET TITLE: BAR AND CONNECTED TO THE GROUND RING ON A GROUND ROD. ' 21. WIRE AND CABLE CONDUCTORS SHALL BE COPPER f 12 AWG F. ONE ROD LOCATED ADJACENT TO THE STANDBY GENERATOR AND MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS. B. 02 AWG,INSULATED STRANDED COPPER CABLE 15 ACCEPTABLE FOR IF SEPARATED BY MORE THAN EIGHT(8)FEET.ONE LOCATED GENERAL INTERIOR GROUND BAR CONDUCTORS ON TENANT IMPROVEMENT SITES. ADJACENT TO THE FUEL TANK 22. GROUNDING CONDUCTORS SHALL BE SOUD TINNED COPPER NOTES UNLESS OTHERWISE NOTED. C. 5/8'OX 10'GROUND ROOS OF SOUD COPPER,STAINLESS STEEL OR 3.6 TOWER GROUNDING(IF REQUIRED): COPPER CLAD HIGH STRENGTH STEEL •2004 TRANSCEND-NIKE CORP.ALL RIGHTS RESERVED SHEET NUMBER: GN1.3 T " Mobile• " 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 60631lip Tel 773-444-5400 GROUNDING STANDARDS(CONTINUED) Fax 773-444-5521 19) 3.8 PERIMETER FENCE GROUNDING(AS REQUIRED): A. CORNER AND END POSTSIlikINC ALL FENCE CORNER AND END POSTS(MINIMUM OF TWO)SHALL HAVE ONE #2 SOUD TINNED COPPER GROUND WIRE CONNECTED TO THE GROUND RING WITH A#2 SOUD TINNED COPPER GROUND WIRE. B. GATE POSTS Transcend-Nike Corporation GATE POSTS SHALL BE GROUNDED TO THE SITE GROUND RING WI111 A AWG BARE SOUD TINNED COPPER WIRE. 2112 W.GALENA BLVD.STE.8-186 AURORA,IL 60506 C. GATES TEL 630888-1281 GATES SHALL BE BONDED TO GATE POSTS WITH A#4/0 FINE BRAIDED FAX.630388-1262 WIRE EXOTHERMICALLY WELDED TO THE GATE AND GATE POST. TNC PROJECT NUMBER:617 3.9 EQUIPMENT ROOM GROUNDING(IF REQUIRED): karnry, inc. THE MASTER GROUND BAR(MGB)SERVES AS THE COLLECTION POINT FOR THE BT5 AS WELL AS ALL INTERIOR NON ELECTRICAL GROUNDED METAL MATERIALS; CONSULTING ENGINEERS HVAC GRILLS.DOOR FRAMES/DOORS,TELCO BOARD,UNISTRLITS,CABLE TRAYS, ALARM JUNCTION BOX,ETC.,SHALL BE GROUNDED WITH#0 AWG STRANDED 406 Meadow Ridge (GREEN)GROUND WIRES WITH INDIVIDUAL RUNS BACK TO THE MGB. E CABLE Prospect Heights,IL 60070 TRAY,DOOR/FRAME AND UNISTRUT MAY BE JUMPERED TOGETHER AND HAVE A SINGLE GROUND WIRE CONNECTION TO THE MGB.) Tel.(847)670-7413 Fax:(847)870.7434 3.10 WALL PENETRATIONS SLEEVES(IF REQUIRED): E-Mail:kamryerlg.com INSTALL PER CONSTRUCTION DRAWINGS. 3.1 I AC COMMERCIAL POWER GROUNDING CONNECTIONS(IF REQUIRED): AT THE ON-SITE RISER POLE LOCATION OR UNDERGROUND SERVICE ENTRANCE W o `,. O .4- O LOCATION,THE NC SERVICE SHALL BE MECHANICALLY BONDED TO THE AC Q M N li)o or In SERVICE ENTRANCE GROUND AS SPECIFIED BY THE NATIONAL ELECTRIC CODE, N ARTICLE 250,AND/OR APPROPRIATE LOCAL CODES.A SEPARATE GROUND ROD tV M 4 SHALL BE PROVIDED AT THIS POINT.AND SHALL BE CONNECTED TO THE EXTERIOR GROUNDING RJNG.A SEPARATE NC SERVICE GROUND AND NEUTRAL SHALL THEN BE ROUTED TO AND CONNECTED TO THE MAIN DISCONNECT AS REQUIRED BY -J LOCAL AUTHORITY. • 3.12 GENERATOR RECEPTACLE GROUNDING: W CCLJ UwJ W THE GENERATOR RECEPTACLE(HUBBLE PLUG)SHALL BE GROUNDED TO THE EGR. W W d ~ W O - w ZO W V 3.13 CAD WELD 4 BURNDY CONNECTION: F 0 cc Q i N CAD WELDS(EXOTHERMIC WELDS)AND BURNDY CONNECTIONS SHALL BOND ALL 0. ° Er p O UNDERGROUND AND DAMP LOCATION CONNECTIONS.SHELTER SKID GROUNDS, 2cc O m H U TONER OR MONOPOLE GROUNDS,FENCING CORNER AND AND GATE POSTS, W 0 LUO O m ANTENNA GROUND BARS,(AGE.)SURGE ARRESTER GROUND BAR,AND THE Z MASTER GROUND BAR(MGB).MECHANICAL CONNECTIONS SHALL BE TYPICALLY CI 0 j LL Q O USED TO BOND ALL INTERIOR EQUIPMENT,COAX CABLE BRIDGES AND COAXIAL W Tn O I W CABLE GROUND KITS.ALL LUG TYPE MECHANICAL CONNECTORS TO THE MGB OR w - w U Ur AGB SHALL BE TWO HOLE TYPE CONNECTED WITH STAINLESS STEEL BOLTS AND (/) CO Z NUTS WITH STAINLESS STEEL LOCK WASHERS AND NOALOX ON EITHER SIDE OF N Q THE BUSS BAR I U 3.14 CHEMICAL GROUND RODS(IF REQUIRED): CHEMICAL GROUND RODS SHALL BE INSTALLED ONLY FOR SPECIAL DESIGN APPUCATIONS THAT REQUIRE SINGLE POINT GROUNDING DUE TO SPECIFIC SITE CONDITIONS. C CV En V ICI 3.15 TENANT IMPROVEMENT SITE GROUNDING:SEE GROUNDING PLAN DETAILS z o 0 O 0 0 3.16 OMITS OF BEND RADIUS: n.��t K y. D IT IS IMPORTANT THAT THE GROUNDING CONDUCTOR CONNECTING THE INSIDE (V V {7..�.� AND OUTSIDE GROUND SYSTEMS BE AS STRAIGHT AS POSSIBLE,WITH NO TURN Q� •,••"•.."• •• i� OR BEND SHORTER THAN ONE FOOT RADIUS WITH A THREE FOOT RADIUS ``.. ' PREFERRED.NO RIGHT ANGLE OR SHARP BENDS SHALL BE ALLOWED. �V • V V2-0338 2 ��It, 3.17 BONDING PREPARATION 4 FINISH: �Z ALL SURFACES REQUIRE PREPARATION PRIOR TO BONDING OF EITHER CAD WELD 7 • PROFESSIONAL EGISic •• OR BURNDY FASTENERS.GALVANIZED SURFACES SMALL BE GROUND OR SANDED r : 2• e TO THE POINT OF EXPOSING THE STEEL SURFACE BELOW,PRIOR TO BONDING THE E�N�jGf�I(NrF�}r�}� i GROUND CONDUCTOR.FOR OTHER SURFACES INCLUDING COPPER BUSS BARS J• E+••+•�E• :: ALL PAINT.RUST TARNISH AND GREASE SHALL BE REMOVED PRIOR TO BONDING �it THE D CONDUCTOR. #a. 04, CAD WELD NTYPE BONDS SHALL BE FINISHED WITH THE APPUCATION OF COLD II _~ GALVANIZATION AND WHEN APPLICABLE.FINISH PAINTED WITH AN APPROPRIATE III 11�L l Ili O,S��Y COLOR AS REQUIRED. f\ jam '\ MECHANICAL TYPE BONDS ON BUSS BARS SHALL BE FINISHED WITH THE ,N�`�Q�`~ APPUCATION OF NOALOX OR OTHER APPROVED CONDUCTIVE MEDIUM MATERIAL BETWEEN CONNECTOR AND BUSS BAR. MECHANICAL TYPE BONDS ON ALL OTHER SURFACES SHALL BE FINISHED WITH FIRE STATION RL THE APPLICATION OF COLD GALVANIZATION AND OR THE APPROPRIATE PAINT TO CH37-975C MATCH AS REQUIRED. RAWLAND 3.18 TESTING: THE OUTSIDE GROUND RING SHALL BE TESTED AFTER INSTALLATION BUT PRIOR TO 599 S McLean Blvd. BACKFIWNG THE GROUND RING TRENCH.THE GROUND FIELD RESISTANCE SHALL Elgin,IL 60120 MEASURE 5 OHMS OR LESS TO GROUND.ANY DIFFICULTY IN ACHIEVING THIS LEVEL OF RESISTANCE MUST BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER THE RESISTANCE TO GROUND SHALL BE MEASURED USING THE FALL SHEET TITLE: OF POTENTIAL METHOD.TESTING SHALL BE PERFORMED BY THE CONTRACTOR FROM WHICH A WRITTEN REPORT SHALL BE PRODUCED FOR REVIEW BY THE OWNER GENERAL 3.19 SPECIAL CONDITIONS: NOTES LUMEN SOIL CONDITIONS IX15T(I.E.,NON-COMPACTABIE ROCK,GRAVEL,SF1AlE, ETC.)THAT PREVENTS THE INSTALLATION OF THE STANDARD GROUNDING SYSTEM 1 AND PROCEDURES.THEN OWNER SHALL PROVIDE FURTHER DIRECTION. •NM TRANSCENLINIKE CORP ALL RIGHTS RESERVED SHEET NUMBER: GN1.4 EQUIPMENT/FOUNDATION PLAN , 4 SCALE: NTS T • iYlobile' 8550 W Bryn Mawr Ave.Ste 100 Chicago,IL 80631 3 EA 3"RIGID(UNDERGROUND) NEW 8.-0'W UTILITY EASEMENT Tel 773-444-5400 I y Fax 773-444-5521 EACH WI 3-500MCM,#0 GR THWN (OR AS REM) L ELECTRIC UTILITIES TO R.O.W.;COORDINATE W/UTIUTY - '— It I COMPANY AND PROJECT MANAGER FOR EXACT CONFIGURATION - _ _ — — — — —' AND TERMINATION I — — —— — a a Transcend-Nike (ni porn ..,11 _ 1c � K v� ur UT 2112 W.GALENA BLVD.STE.8-186 — —Y[ K m Pc K K AURORA,IL 60506 ME O �r—�_ , I NEW 3 GANG ELECTRIC SERVICE METER SOCKET 200AMP, .S30-68E4281 _ /j/ j//j jj j -.II I 120/24 W SINGLE PHASE 3 WIRE W/BY-PASS FEATURE FAXL.830.88&1282 { (MILBANK OR EQUAL)OR APPROVED EQUAL);FURNISHED TNC PROJECT NUMBER:617 I AND INSTALLED BY CONTRACTOR I I ,/ j j / r. _- — kamry, inc. II CONSULTING ENGINEERS I ` j j ,)' 406 Meadow Ridge B 9 Prospect Heights,IL 60070 NEW 200 AMP NEMA 3R OUTDOOR LOAD CENTER; (AS MANE.ATLANTIC SCIENTIFIC CORP.) Tel.(847)670-7413 3"DIA.PVC CONDUIT FOR TELEPHONE SERVICE.SEAL ALL j. % I +��,�.� Fax (647)670-7434 JOINTS.42'MINIMUM BELOW FINISHED GRADE.END S- GENERATOR RECEPTACLE COORDINATE WI T-MOBILE FOR E-Mail:kamryeng.corn TERMINATING INSIDE THE SHELTER SHALL BE COMPLETLY �/ € / SPECIFIC MAKE AND MODEL SEALED AFTER INSTALLATION OF TELEPHONE SERVICE BY LOCAL _ / / �,. 0 y / UTIUTY COMPANY.SUPPLY FULL LENGTH PULL ROPE; FIREHOUSE 30W X 24"H X 129 NEMA 3R ENCLOSURE SUPPLIED AND INSTALLED BY CONTRACTOR '.-'' �� ���� I� • • ••• • — ''^ -- W/BACKBOARD FOR TELEPHONE 0 0 0 0 • j/ / r ..� EQUIPMENT;HOFFMAN OR EQUAL Q N . �_ I �� . I Imo..._-=...—____L--_� .//� I I • - I / —_ .- W w w z O % / IIs �' w w w w �;' F o x zd co /,,/,/*7/,//'//' j/ O� OVERYIEAD ELECTRIC l/ a p Y OE v cc O m }- U '.: ❑ ❑• UE— UNDERGROUND ELECTRIC Ur-- w O Ow O Z7 °3 12 ` 1 LE /// -�.� OT— OVERHEAD TELEPHONE O� 0303 0 O O m i /� ZZ ✓�� � `,/ UT— UNDERGROUND TELEPHONE U L — O UTIUTY POLE UTILITY PLAN AT BTS ''TRENCH DETAIL SCALE: NTS z 0 0° 0 0 0 , SCALE: NTS NOTE:SEE ALSO UTIUTY CONTRACT CONSTRUCTION PLAN: I S" ,'`V~,�i1 CONFUCTS SHALL . BE CLARIFIED WITH OWNER IN WRITING " ,; t �.� 062 033842 ;9��► NEW T-MOBILE EQUIPMENT '£' '� SLAB/PLATFORM RESTORE PREVIOUS GRASS OR.GRAVEL ' 4*• REGIgrE D ���1 SURFACE OR INSTALL WITH NEW • PROFESSIONAL SURFACE MATERIAL;PER PLANS OR TO Z Y • i T T T (3)NEW UNDERGROUND ELECTRIC CONDUITS MATCH EXISTING E G NEFR Te . PRIMA=', E5-15#2 BT,3 3 I FRM PPC TO EACH BTS f411 ^ 3TSti 1t r I i tttl /(LI '�\5 .` !rr f I MARKING TAPE 11 1^' I' . - I (I)2'0 PVC UNDERGROUND CONDUIT o o \\\�lL�� u W / I FROM DEMARC ENCLOSURE TO PRIMARY > BTS CABINET;INCWDE UNDERGROUND CLASS"A"BACKFILL WITH CLAY FREE OF DEBRIS ! I / I FIRE STATION RL j•.., I PULL ROPE LABELLED AT EACH END AND AND ORGANIC MATERIAL-COMPACT IN 9'LIFTS 1••.. .. 1 , / CH37-975C 12 PR SHIELDED TELEPHONE CABLE I I / I O-G. SELECT MATERIAL;COMPACT 9"UFTS RAWLAND L 4 J. 1-- CALL JUUE TOLL FREE i. ELECTRICAL BEDDING MATERIAL 599 S McLean Blvd. L / NEW HINGED COVER NEMA 3R MEDIUM ENCLOSURE I(800)892-0 123 L— � (SAND ORARGHITECTAPPROVED Elgin,IL60120 1 L-UE---yam -,I I I FORT LCO INSTALLATION;INCWDE GROUND KIT AND 0PQATGS 24 HOURSA EQUAL) BACKBOARD(HOFFMAN#A-3OR3O 12HCR OR DAY SGS DAh A'MAII o Td APPROVED EQUAL) WARNING I-G. ���4$' TELEPHONE SERVICE CONDUIT(5) SHEET TITLE : 2'0 PVC CONDUIT UNDERGROUND FOR V S U NEW H-FRAME FOR PPC � � �,/� ALARM CIRCUIT FROM PPC CABINET TO I (SEE ELECTRICAL SITE PLAN) PRIMARY BTS + *A, ��-''�s►��� UTILITY PLAN NEW 3-GANG METER BANK. 120/240V,3W NEW UNDERGROUND ELECTRIC SERVICE L POWER SERVICE CONDUITS AND ____— ate• CONDUCTRORS;SEE ELECTRICAL SINGLE PHASE,GOOA NEMA 3R ENCLOSURE. a NEW UNDERGROUND TELEPHONE SERVICE O-3' _J I-0" �— 0-3" PLAN W/INDIVIDUAL(3)200A BREAKERS ON _----K S GALLBE�� -NI MIN. 02004TRANSCENDKECORPALLRIGHTSRESERVED LOAD SIDE You DIG CALL SHEET NUMBER: I(800)892.o 123 48 HOURS BEFORE E 1.1 YOU DIG - VA TREE PLANTING DETAIL . ,,...=,\!. .. SCALE: NTS . T . aiNlobile• a 8550 W Bryn Mawr Ave.Ste 100 - Chicago,IL 60631 2.5 MINIMUM CAUPER(4*IN GREATER DOWNTOWN AREA) Tel 773-444-5400 SHADE TREE WI.M1 STRONG CENTRAL LEADER(DO NOT Fax 773-444-5521 1 PRUNE,STAKE,OR WRAP TREES UNLESS DIRECTED TO DO 50) i * 2"MULCH LAYER IN GI DIAMETER RING(DO NOT PLACE 10.,. Mir.Ilk III lift e 1 t.4 , MULCH IN CONTACT WITH TREE TRJNK) . 4.4 Willork pLANTFW5:15WITIIHIPPEDUISw:GAG:ADR:BIZAA5VIKETNG 46..4*1.111111." ROOTBAI.L AROUND'ME ROOT BALL,CUT WIRE IN FOUR PLACES AURORA,IL 60508 oCRIF:0TOBALLF . !MM. • Aille,,o_...... . ........,,,,. .41/415 , I W11111P"irr# .-. TRUNK FLARE VISIBLE ATT11E TOP OF TI-IE ROOTBALL REMOVE ALL TMNE,ROPE,WIRE AND BURLAP FROM TOP HALF AND POW DOWN 8'INTO PLANTING HOLE) • . ... Transcend-Nike Corporation 2112 W.GALENA BLVD.STE.8-188 --- pe(ApIr----- 4"HIGH SOIL SAUCER BEYOND EDGE OF ROOT BALL l'i TEL.830-6884281 FAX.WO-688-1282 •.....• •• •• .. .. .. .. .. .. .. .. . .. .. .. .. • PLANTING SOIL BACKPILL . .. .... .. .. .. .. . INC PROJECT NUMBER:617 W,- .. . .. . .. .. .. .. .. . .. . .. . . TAMPED SOIL AROUND BASE '- •• •'••- •••'' ' '• '' ' ..•.,. ..... .. .. .. -l I Iiitl allrOltii .. .. .. .. . .. .. .. .. • ..... ........ •• •• " " " • kamry, inc. , .•5.- .-L- ROOT BALL ON UNINCAVATED OR TAMPED SOIL . .• . .. .... .. .. ... rili-- _. = ."..2....'............•.....','.....'..*. (-- -V--- . 11 l' I i—i II— ....... .. . ... ... .. .. CONSULTING ENGINEERS .. .. .. .. .. . 406 Meadow Ridge A Prospect Heights,IL 60070 ... ...,. .. .. .. .. . ..THREE PIT 3 TIMES WIDER TI-IAN DIAMETER OF ROOT . ...... .. .. .. .. .. .. . 3-FOSN/30'HT. Tel.(847)870-7413 ..... .. . .. .. .. .. .. BALL(EDGES OF PIT TO BE ROUGHENED) . I Fax:(847)670-7434 .. ..... .. . .. E-Mail:kamryeng.com WALKWAY;SUBMIT AND ••, •- - •• •• •• '''' ______________ "C -..-._,.,..._,J.......\...._ --/ . vl .• 511RU5 PLANTING DETAIL SAMPLES "USE OWNER APPROVED . . -1 1 •rr I W 9 a 9 9 :fs 471,1J' SCALE: NTS I-PIM/GI-IL gsi L I i; " •- ctl , ,.,, '7 7 -..::.:•;:.'..'..,,-A.,"7 • ,.1' I. 0 ‘/. IO ‘- ..- I -; ,\-.., , : 1 ' i 3-0015/30"HT. •• .• -. •• : - 2. -• I . -- -11,1 . t I 'f 5 Lii teLl Lu Lu Cr SHRUB ca- cc o Y CROWN OF ROOT BALL FLUSH WITH EXISTING GRADE 0 ''Y Et" ROOT BALL WITH BURLAP 1/2 REMOVED •'..•:.''..' .. ' .. ' .. ' .. '.: •• • ' ''''/; '-:: - - ' -.•' co 0 cc 11.1 co LLJ LL u j 0 CD 2'MULCH LAYER IN SAUCER SHAPE •` ?1,%../"..•' '.',•.?.,.; ‹,..'e>'. . z:it-; -• Ci) ILI .... i 0 . . .. . .. 000 . .. • co i .... ... . .. co . 0_4010. . .. . .. . . - FINISH GRADE Illall—=11E--7111•41 . . 11=111= PLANTING SOIL . •.- . . ... - — . - • ' __ ci .,- Ol cc ..rt ici . EXISTING SUBGRADE . . ... .... . . . . Z 0 0 0 0 0 . . . . . . . . .. . . . . .• . I i . . _..... . . . . . . . .. .. .. .. .. . . . . . ..........„...‘,N._‘‘‘ti. . .. . . . .. . . .. . . . . • . ••••••... I• ... . .. . .. . .. .. . .. 4-0.\C, Y. Seit,tti. . . .... . .• .. .. . • . - . ..•- • -/ .. .. . . . ...—*5-............,iv'lb 4i.' 062-033842 •••• :rt..: .....- r - te'r •.14-• REGISTERED .. .. .. . . . . .. .. . .. .. ------ , • PERENNIAL/GROUNDCOVER PLANTING ., ' e : PROFESSIONAL - ", SCALE: NTS ir ENGINEER. 7. oF qt. ... i-GL5K/2.5 CAL. ..- ....1 ill /41.1NO‘ lit Aso Ow Armr MAANWNS... GROUNDCOVER/PERENNIAL PLANT SPACING VARJE5 DEPENDING ON PLANT SPECIES AND SIZE SEE PLAN FOR.SPACING. FIRE STATION RL ' CH37-975C • 1-----...,\ RAWLAND i 599 S McLean Blvd. • INN Elgin,IL 60120 / •71/ .. PERENNIAL/GROUNDCOVER OUAN. M BOTANICAL NAME/COMMON NAME SIZE CONDITION SHEET TITLE: FINISH GRADE A. eel... 2'MULCH LAYER I GLSK GLEDITSIA TRIACANTI105'SKYLINE 2.5'CAL BIB ...e.,•_ ••l•11 ,"••_.,L Wei ........................... I 1. ....• • i % PLANTING BED RAI5ED FOR ADEQUATE DRAJNAGE LANDSCAPE —II 1=-1 •''.•.••:!... :-. •• •••-:'' ..'1: ; I PINI PINUS NIGRA C.HT Be PLAN 1 i_ , t. ... ... , ". ; .... PLANTING SOIL A1.15.T.NAktriNc 1_ -I I I_ I _ _ _ 1 EXISTING SUBGRADE 3 C015 CORNUS SERJCEA'15ANT1' 30'HT. BIB \ e 2004 TRANSCENO.NIKE CORP ALL RIGHTS RESERVED -I I I—I I I—I I I—I I I—I I i LSAAM REDOSIER DOGWOOD 3 FOSN FORSYTHIA SUSPENSA SUNRISE 30'HT. BIB SHEET NUMBER: SUNRISE FORSYNTHIA , , L1.1 INSTALL T . Mobile. . • O'TRUE ANTENNA ANTENNA ANTENNA ANTENNA ANTENNA ELECTRICAL MECHANICAL ppSTALL7 ANTENNA DT5 NO- SECTOR QUANTITY POSITION MANE MODEL AZIMUTH DO NTILT DOWNTILT A FKAPJY COLOR. REFERENCE FUNCTION JUMPER MAIN UNE JUMPER 8550 W Bryn Mawr Ave.Ste 100 A I Al EMS DRCS-19-O2DPQ 0' 0° 0 Y I RED MAIN TX I/RX MAIN I/2"0(6'-YU I-5/8'0(140-0'L) I/2'0(6'-(7L) Chicago,IL 60631 3 RED RESERVE TX3 T el 5 RED RESERVE TX5 Fax 773 444552�1177 RED RESERVE TX7 1� t A2 EMS DR65-I9-02DPQ 0' 0° 0° Y 2 RED SECONDARY TX2/RX DIVERSITY 1/2'0(6'-0R) I-5/8'0(140-0'U 1/2'0(C-0'L) IIIII r- . SECTOR'A' 4 RED RESERVE TX4 i I I �` YA I A2 6 RED RESERVE TX6 —' NQ 8 RED RESERVE Tx8 Transcend-Nike (:urporxtiuu 1 I B I B I EMS DRGS-19-02DPQ 120' D• 1' Y I BLUE MAIN TX'/RX MAIN I/2'0(G.-01) I-5/8"0(140-01) I/2'0(6'-01.) 2112 W.AURORA,ILLENA LVD.STE.8-188 �.♦ i. 3 BLUE RESERVE TX3 I TEL 630-688-1281 I 1IFrI FAX.630-88&1282 ♦♦�♦ �� 8 1 5 BWE RESERVE TXS TNC PROJECT NUMBER:617 �31A C2 a 8 7 BWE RESERVE TX7 + I B2 EMS DR65-I9-02DPQ 120° G° I° Y 2 BWE SECONDARY TX2/RX DIVERSITY I/2.0(6'-0"l.) I-5/8r 0(140'-0'u 1/2'0(6'-O'IJ 1. kamry, inc. � 4 BWE RESERVETX4 OP 6BWE RESERVETX6 CONSULTING ENGINEERS 406 Meadow RiOge 8 BWE RESERVETX8 Romped Heights,IL 80070 C I C I EMS DR65-19-02DFQ 240° D° G' Y I WHITe MAIN TX I/RX MAIN I/2'0(6'-0'L) I-5/8'0(140'-0'L) I/2'0(6'-0"L) TeL(847)670.7413 Fax:(847)670-7434 �4� ' 3 WHITE RESERVETX3 E-Mail:kamryeng.O3M ♦ :� Lp 5 WHITE RSERVE TX5 ♦ B2 7 WHITE RESERVE 7X7 1 1 v v o C I I C2 EMS ()RCS- 9-02DFC] 240° tD• O' Y 2 WHITE SECONDARY TX2/RX DIVERSITY I/2.0(6'-01.) I-5/8'0(I40-0'L) I/2'0(6'-0'L) QO N : : m ................„,,/ N In 4 WHITE RESERVE 7X4 6 WHITE RESERVE 'MG 8 WHITE RESERVE TX8 I I • I— w w w CC z ANTENNA/COAXIAL CABLE NOTES w w w w J w A.EACH UNE OF COAX SHALL BE LABELED PURSUANT TO THE COLOR CODING SCHEDULE 12'BEFORE ANY CONNECTOR AND WHEREVER IT O cc w zO = U cn PASSES THROUGH A WAVERGUIDE PORT.COLOR CODING METHOD I5 BY MEANS OF I"WIDE COLORED ELECTRICAL TAPE WRAPPED a o EC ¢ 0 AROUND COAX THREE TIMES TO PRODUCE A STRIPE.(I.E.TWO RED WILL HAVE TWO STRIPES) (2rn IYC) O 0 B.ALL MAN COAX UNES WILL E GROUNDED IFIED LOCATIONS AND ACCORDING TO ATIONS. C.ALL INSTANCES WHERE THE C COAX HAS BEENTCUT,CMODIFED,SPLICED,OR STRIPPED SHALL BE PROPERLY MANUFACTURER'S G TO co OLL Cl p 0Z m MANUFACTURER'S SPECIFICATIONS EXCEPT WHEN LOCATED IN THE EQUIPMENT SHELTER. 0 OD U Q 0O D.ALL COAX 15 TO BE PROPERLY INSPECTED UPON RECEIPT AND SHALL BE HANDLED ACCORDING TO THE MANUFACTURERS jLij I w SPECIFICATIONS.R SHALL NOT BE BENT BEYOND SPECIFICATIONS. — n U (D cn E.COAX SHALL BE FASHIONED TO SHED WATER IMMEDIATELY AT HORIZONTAL BENDS — to ' F.ANTENNA AZIMUTHS ARE DEGREES OFF OF TRUE NORTH,BEARING CLOCKWISE,IN WHHIC THE ANTENNA FACES DIRECTED.ALL — U ANTENNAS(AND SUPPORTING STRUCTURES AS PRACTICAL)SHALL BE ACCURATELY ORIENTATED IN THE SPECIFIED DIRECTION. ANTENNA DOWNTILT DETAIL vs EQUIPMENT/FOUNDATION PLAN el SCALE: NTS SCALE: NTS z° 0 0 0 `0 0 ` t. I )THE GPS ANTENNA MOUNT IS DESIGNED TO FASTEN TO A STANDARD I-I/4"0, '_ r�•KK t �; DOWNTILT ASSEMBLY ..'V ..""Y. 0 A, SCH.40 GALVANIZED OR STAINLESS STEEL PIPE.THE PIPE MUST BE THREADED ..•` t • AT THE ANTENNA MOUNT END.THE PIPE SHALL BE CUT TO THE REQUIRED "' Q °• ����p� °'•'9 GPS ANTENNA LENGTH(MIN OF 18")USING A HAND OR ROTARY PIPE CUTTER TO ASSURE A I ' •06G 842 •°•• Ft SMOOTH PERPENDICULAR CUT.THE CUT PIPE END SHALL BE DEBURRED AND ���(t�� .Z i i . SMOOTH ANTENNAS MOUNT.)�AGAINST THE NEOPRENE GASKET ATTACHED TO V.14(1. P ESSIONat. - i PANEL ANTENNA PIPE CAP IR 1-1/4'SCHED 40 x 18'LNG If ___ MIN.SS OR GALV.PIPE 1 t4 ENGINEER • 2) GPS ANTENNA MUST BE PLUMB TO WITHIN I/8"OVER G'-0" ?4 OF r • 3) INSTALL ANTENNA AS INDICATED ON SITE PLAN.IF INSTALLING ON CABLE BRIDGE GPS IS TO =III ~w. �+ III, CABLE TO PIPE GND KIT. t i` `.74%. WELDED PIPE TO PIPE IIP I10' BURNDY TYPE GAR BE PLACED A MINIMUM OF 10 ABOVE GRADE,ON THE FURTHEST POST FROM THE TOWER TO ATTAIN tX%�LIINO�1 CLAMP'MTS.X55-510 WI� MAXIMUM EXPOSURE TO SKY 1t>>�1/4" OR EQUAL HORIZONTAL/LEVEL }Will �' #2 A 4)GPS TO BE PLACED WITH OPTIMUM 360°VIEW OF SKY;WHEN PLACING ON THE SIDE FIRE STATION RL �VE Icj,I/IIl. ;: T AS SPECIFIED I(!�'r OF A WALL OR VERTICAL STRUCTURE,GPS MUST BE A MINIMUM OF 3'AWAY ON STANDOFFS CH37-975C IN SCHEDULE —_ RAWLAND WEATHERPROOFING KIT.ANDREW ' N221213 OR EQUAL.VERIFY 599 S McLean Blvd. �` 1� i WITH PROJECT MANAGER Elgin,IL 60120 • IC I i %ra ANTENNA MOUNT PIPE IIIr SHEET TITLE: SEE SITE PLAN C I/2'0 COAX CABLE(OR EQUAL) II MIN.BENDING RADIUS PER MFGS SPECIFICATIONS ANTENNA CABLE TO PIPE GROUND , CABLE(PROVIDED W/KIT) SCHEDULE KIT.BURNDY TYPE GROUND I M6 GROUNDING KIT. ll 1/2 AWG BCW TO TOWER O 2004 TRANSCEND-NIKE CORP ALL RIGHTS RESERVED GROUND BAR.CONNECT WITH 111 T CADWELD CONNECTOR SHEET NUMBER: �-- TO GROUND RF1.1 ,� ' FOUNDATION PLAN '„ SCALE: NTS ly-8 T • Mobile 8550 W Bryn Mawr Ave.Ste 100 r-o- I T-8' I.-G• Chicago,IL 60631 b Tel 773-444-5400 - Fax 773-444-5521 i l Th �� I— `I Transcend-Nike CorpoI atian -4 I 211E W.GALENA BLVD.SEE.B-186 - AURORA.IL 60506 G j•; / - • TEL 630-8661261 ' G 4 . 4 FAX FA 830 88&1282 • U _ TNC PROJECT NUMBER:617 V. G . 4 F t y • ` inc. kamry, G l' -• �' iv CONSULTING ENGINEERS . O 406 Meadow Ridge . ._ .. O Prospect Heights,IL 60070 N iV Tel.(847)670-7413 '' — Fax:(847)670-7434 A - - E-Mail:kamryeng.com Li . . • Ae - G ` 0 0 0 0 9 • N 4 • • <G 'I NN . LO g W a w z ( Z TY 5 p W CC W L J • I F o 7 _ 0. rn p O Y w LLLL p u. O 0Z DD O p : LI- Z FO m co WW I W U) ((I) U Z U 0 GENERAL NOTES C. AU.BOLTS.NUTS AND WASHERS FOR STRUCTURAL STEEL FRAMING SMALL CONFORM TO THE REQUIREMENTS OF ASTM A325. SUP CRITICAL TYPE BOLTS AU.EXPOSED FASTENERS:NUTS 4 WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE c. DCCEPT WHERE OTHERWISE INDICATED,CONCRETE SMALL BE NORMAL WEIGHT AND WITH MINIMUM 7-DAY a. DESIGN AND CONSTRUCTION OF THE STRUCTURE SHALL CONFORM TO ALL APPLICABLE BUILDING CODES. NOTED. COMPRESSIVE STRENGTHS OF Pc-4000 P51. AU.EXTERIOR EXPOSED CONCRETE SHALL BE AIR ENTRAINED WITH G%AIR O CV17 . a, CONTENT. Z o 0 0 0 0 B. DESIGN CRITERIA: D. ALL WELDING SHALL BE DONE BY QUAUFIED WELDERS AND SMALL CONFORM TO AWES DI.1 STRUCTURAL WELDING 0y.1.a10‘11. • t'1 CODE',LATEST EDITION. ALL WELDING ELECTRODES SMALL BE E70XX.MIN.FILLET WELD 512E SMALL BE 3/16- /�{( Y `i� �ti"r�' �`�t UVE LOAD:100 POP d. ALL CONCRETE WORK SMALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF A, `A, 1V•`..•. .9t:�j 1 ' \I•ik Y. BE t EQUIPMENT LOAD:(3)CABINETS-EACH 1200LBS e. ALL CONNECTIONS SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR. THE CONNECTIONS SHALL BE DESIGNED V '., LJ _ ! �......... ;i EQUIPMENT SIZE:5'-3-H 4'-5'W 2'-I•D BY,OR UNDER THE SUPERVISION OF A UCENSED STRUCTURAL ENGINEER IN THE STATE OF I W NOIS. DETAIUNG SHALL BE e. CEMENT SHALL CONFORM TO ASTM C 150 TYPE I. AGGREGATES SHALL CONFORM TO ASTM �O -1 ; r V� ••.{/ t� WIND SPEED:90 MPH PERFORMED USING RATIONAL ENGINEERING DESIGN AND STANDARD PRACTICE IN ACCORDANCE WITH THE CONTRACT WEIGHT). . 4: C81 Q4Q1 ••-r 4i Q /• ••��,,(�'�QQ� • �� SNOW LOAD 25 PSP DOCUMENTS. THE GENERAL DETAILS SHOWN ON THE DRAWINGS ARE CONCEPTUAL ONLY AND DO NOT INDICATE THE n r w"•^""''� ••� / SEISMIC ZONE:I REQUIRED NUMBER OF BOLTS OR WEW SIZES.UNLESS SPECIFICALLY NOTED. ADVISE THE ENGINEER IMMEDIATELY IF THE I. NO CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE. �'•• REGISTERED •�Z F %�• nc^'`' ft '.y,� INFORMATION ON THE DRAWING 15 NOT SUFFICIENT FOR COMPLETE DESIGN OF CONNECTIONS. U . f • REGIS V S c. THE GENERAL CONTRACTOR SMALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY g. CONCRETE MIX DESIGN SHALL BE SUBMITTED TO ENGINEER FOR REVIEW. 1 STRUCTURAL j �e : {y���`�`(��e) _ DISCREPANCIES PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. I. THE FABRICATOR/ERECTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW,ENGINEERED AND CHECKED DRAWINGS A' .• L�tdG•'N i � P • PROFESSIONAL SHOWING SHOP FABRICATION DETAILS,FIELD ASSEMBLY DETAILS AND ERECTION DIAGRAMS FOR ALL STRUCTURAL STEEL h. REINFORCING BARS SHALL CONFORM TO ASTM AC 15,GRADE CO. ALL WELDED WIRE FABRIC ft el • ; 1 1!t SSW ./ d. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS OF ALL DRAWINGS INTO THEIR SHOP WITH EACH SUBMITTAL OP SHOP DRAWINGS,THE FABRICATORS ENGINEER SHALL CERTIFY THAT THE CONNECTIONS HAVE BEEN ASTM A 185. 6 OF T a DRAWINGS AND WORK. DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE AISC SPECIFICATIONS AND THE CONTRACT DOCUMENTS. �✓t •_m �� r e. NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF CERTIFIED MILL TEST REPORTS SHALL ALSO BE SUBMITTED. AND SECURED IN PLACE N.. ALL CONCRETE NACCORDA C WITH BEFORCEMENT SHALL DETAILED, PAROCEDURES AND DREQUIREMENTS OUTUNED ELED.SUPPORTED D j=t �CuNp15,�" Ili OF N THE ENGINEER OF THE'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES' Z ����� .11 /4 jNo�S �• g. EXCEPTION IS TAKEN TO ALSC CODE OF STANDARD PRACTICE PARAGRAPH 4.2.1 REGARDING OWNERS AND SUPPORTS IN CONTACT WITH EXPOSED SURFACES SHALL BE PLASTIC TIPPED. `` • ♦�~. I. THE STRUCTURE 15 DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR SMALL FURNISH ALL FABRICATORS RESPONSIBIUTY FOR CONNECTION DESIGN AND ADEQUACY OF SHOP DRAWINGS. COMPLIANCE WITH THE >>>�� TEMPORARY BRACING AND/OR SUPPORTS REQUIRED AS THE RESULT OF THE CONTRACTORS CONSTRUCTION METHODS AND/OR REQUIREMENTS SHOWN ON DRAWINGS AND/OR SPECIFICATIONS,CONNECTION DESIGN AND DETAIUNG 15 THE CONTRACTORS J. UNLESS NOTED OTHERWISE.ALL SLABS ON GRADE SHALL BE REINFORCED WITH ONE(I)LAYER OF 6 X 6-W2.9 x SEQUENCES. RESPONSIBIUTY. ENGINEERS REVIEW OF SHOP DRAWINGS 15 FOR GENERAL CONSIDERATIONS ONLY AND DOES NOT W2.9 W.W.F.AT MID HEIGHT OF SLAB. CONSTITUTE AN ACCEPTANCE OF THESE RESPONSIBIUTITS BY THE OWNER AND/OR ENGINEER. FIRE STATION RL g. DO NOT SCALE THESE DRAWINGS.USE DIMENSIONS. k. ALL REINFORCING SPUCES SHALL CONFORM TO THE REQUIREMENTS OF ACI 318,LATEST EDITION.BUT IN NO CASE CH37-975C H. MINIMUM SMEAR CAPACITIES:PROVIDE AT LEAST ONE HALF OF THE UNIFORM LOAD CARRYING CAPACITY OF THE BEAM SHALL BE LESS THAN 36 EAR DIAMETERS,UNLESS NOTED OTHERWISE. ALL WELDED WIRE FABRIC SHALL BE LAPPED TWO(2) h. THE CONTRACTOR SMALL INFORM THE ENGINEER IN WRITING OF ANY DEVIATION PROM THE CONTRACT DOCUMENTS. WITH THE ASSUMPTION OF FULLY BRACED COMPRESSION FLANGE. FULL MESH PANELS AND TIES SECURELY, WHERE REQUIRED,DOWELS SHALL MATCH SIZE AND NUMBER OF MAIN RAW LAND THE CONTRACTOR SMALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY THE ENGINEERS APPROVAL OF REINFORCING. SHOP DRAWINGS.PRODUCT DATA.ETC.,UNLESS THE CONTRACTOR MA5 SPEOPICALLY INFORMED THE ENGINEER OF SUCH I. THE DEPTH OF A SIMPLE SMEAR CONNECTION SHALL NOT BE LESS THAN ONE HALF OF THE NOMINAL DEPTH OF THE 599 S McLean Blvd. DEVIATION AT THE TIME OF SUBMISSION,AND THE ENGINEER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION. BEAM. THE MINIMUM NUMBER OF BOLTS PER CONNECTION SHALL BE TWO(2)-44-0 BOLTS I. WELDING OF REINFORCEMENT IS NOT PERMITTED. Elgin,IL 60120 ALL THINGS WHICH,IN THE OPINION OF THE CONTRACTOR.APPEAR TO BE DEFICIENCIES,OMISSIONS.CONTRADICTIONS.. J. ALL BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER UP. PROVIDE CAMBER.OR SHORING AS INDICATED ON m. MINIMUM CONCRETE COVER 15 3 INCHES. APPROVED SPACERS SHALL BE USED TO ENSURE MINIMUM COVER. AND AMBIGUITIES,IN THE PLANS AND SPECIFICATIONS SMALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PLANS THE DRAWINGS. SHEET TITLE: AND/OR SPECIFICATIONS WILL BE CORRECTED,OR A WRITTEN INTERPRETATION OF THE ALLEGED DEFICIENCY,OMISSION, n. PLACE ALL SLABS OIJ GRADE WITH AN APPROVED PATTERN AND SEQUENCE OF CONSTRUCTION AND CONTROL JOINTS CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE ENGINEER BEFORE THE AFFECTED WORK PROCEEDS. P. THERE SHALL BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES (MAXIMUM OF 15'-O'O.L.)TO MINIMIZE SHRINKAGE CRACKS. WITHOUT THE PRIOR APPROVAL.OP THE ENINGEER. FOUNDATION o. ALL DEPOSED EDGES OF CONCRETE SLABS SHALL BE ROUNDED OVER AND QIAMFERED 3/4.. STRUCTURAL 51121110115 I. ALL DAMAGE TO GALV.COATINGS SHALL BE REPAIRED. NO ZINC OR PRE-GALV.SHALL BE USED FOR REPAIRS. p. CONSTRUCTION SHALL BE IN ACCORDANCE WITH GENERALLY ACCEPTED INSTALLATION PRACTICES. PLAN a. ALL STRICTURE STEEL WORK SHALL CONFORM TO THE RISC SPECIFICATION FOR THE DESIGN.FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS',LATEST EDITION,AND THE MSC'CODE OF STANDARD PRACTICE FOR STEEL CONCRETE NOTES q. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE MATERIALS.AND BUILDINGS AND BRIDGES'.LATEST EDITION,EXCEPT AS MODIFIED BELOW OR IN THE SPECIFICATIONS. INFILTRATION OF WATER.SOIL,AND OTHER OCCURRENCES WHICH MAY DECREASE THE STRENGTH OF DURABIUTY OF THE O 20d TRANSCEND-NIKE CORP ALL RIGHTS RESERVED S. ALL FOUNDATIONS SHALL BEAR ON UNDISTURBED,NATURAL SUBCRADE WITH A MINIMUM BEARING CAPACITY OF FOUNDATION. b. ALL STRUCTURAL STEEL PLATES.SHAPES AND BARS SHALL CONFORM TO ASTM A36,UNLESS NOTED OTHERWISE. 3000 PSI AS INSPECTED AND APPROVED BY THE OWNERS SOIL TESTING LABORATORY. THE SUITABLE BEARING MATERIAL SHEET NUMBER: COLD FORMED TUBING SHALL CONFORM TO ASTM A500 GRADE B. PIPES SMALL CONFORM TO ASTM A53 TYPE E OR 5. ALL SMALL BE VERIFIED BY AUGER PROBE OR EQUIVALENT MEANS BY THE OWNERS SOIL TESTING LABORATORY. STRUCTURAL STEEL.COMPONENTS 4 FABRICATED ASSEMBLIES SHALL BE MOT DIPPED GALVANIZED AFTER FABRICATION. b. ALL PERIMETER WALL AND COLUMN FOOTINGS SHALL BEAR A MINIMUM OF 3'-G'BELOW FINISHED GRADE UNLESS S 1.1 OTHERWISE SHOWN ON THE DRAWINGS itto 1 City of Elgin Agenda Item No. 3 TE p tos' E L '}��� 0 G April 8, 2005 Iwo ' moo ,di N rots! TO: Mayor and Members of the City Council FINANCIALLY STABLE CITY GOVERNMENT EF F K:RN I SE WIC:E`;. AND QUALITY INFRASTRUCTURE FROM: Olufemi Folarin, City Manager Richard G. Kozal, Assistant Co oration Counsel SUBJECT: Proposed Lease with T-Mobile to Establish Cellular Communications Tower at Fire Station No. 4 (599 South McLean Boulevard) PURPOSE The purpose of this memorandum is to provide the mayor and members of the City Council with information for considering a proposed lease agreement with T-Mobile that would allow the telecommunications provider to establish a cellular communications tower at Fire Station No. 4 (599 South McLean Boulevard). RECOMMENDATION It is recommended that the City Council approve the proposed agreement with T-Mobile to establish a cellular communications tower at Fire Station No. 4. BACKGROUND Representatives from T-Mobile USA, Inc. (operating as a subsidiary of VoiceStream GSM I Operating Company, LLC) approached the City last year seeking approval to establish a cellular communications tower at Fire Station No. 4, 599 South McLean Boulevard. Establishing a cellular communications tower at that location requires conditional use approval. The zoning and subdivision hearing board has unanimously recommended approval of the conditional use permit and that recommendation is being presented to the City Council for consideration on this agenda as a separate item. Should the City Council wish to enter into the proposed lease agreement with T-Mobile, it will also be necessary to approve T-Mobile's application for a conditional use permit. The City negotiated the terms of the proposed lease agreement with T-Mobile while its conditional use application was being processed. The lease establishes an initial five-year term with three, five-year renewal periods (for a total of twenty years). The lease provides for an annual rent of $18,000 (paid monthly) that is annually increased by four percent over the preceding year's rent. T-Mobile Lease at Fire Station No. 4 April 8, 2005 Page 2 The lease agreement also contemplates co-location on T-Mobile's cellular communications tower by additional cellular communications providers. Any additional telecommunications provider seeking to co-locate on the T-Mobile tower would be required to execute a separate ground lease with the City for its communications equipment, providing the City with an additional revenue stream from the lease of the property. Should the City ever need to reuse the leased property for a capital project approved by the City Council, the lease agreement may be terminated after the initial five-year term after providing T- Mobile with six months' notice. COMMUNITY GROUPS/INTERESTED PERSONS CONTACTED None. ANCIAL IMPACT The revenue generated from the lease agreement will be $18,000 per annum with said amount increased by an additional 4 percent every year of the agreement. The resulting proceeds from this agreement will be credited to General Fund, account number 010-0000-546.02-19 "Rental- Land & Buildings—T. Mobile". \oxyLEGAL IMPACT None. ALTERNATIVES 1. Approve the proposed lease agreement with T-Mobile to establish a cellular communications tower at Fire Station No. 4 (599 South McLean Boulevard). 2. Reject the proposed lease agreement with T-Mobile to establish a cellular communications tower at Fire Station No. 4 (599 South McLean Boulevard). Respectfully submitted for Council consideration. rgk Attachment