Loading...
HomeMy WebLinkAbout19-39 Resolution No. 19-39 RESOLUTION AUTHORIZING EXECUTION OF A PURCHASE AGREEMENT WITH SLY INCORPORATED FOR PURCHASE OF BIN VENT DUST COLLECTORS BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN, ILLINOIS, that pursuant to Elgin Municipal Code Section 5.02.020B(9)the City Council hereby finds that an exception to the requirements of the procurement ordinance is necessary and in the best interest of the city; and BE IT FURTHER RESOLVED BY THE CITY COUNCIL OF THE CITY OF ELGIN, ILLINOIS, that Richard G. Kozal, City Manager, and Kimberly A. Dewis, City Clerk, be and are hereby authorized and directed to execute a Purchase Agreement on behalf of the City of Elgin with Sly Incorporated, for purchase of bin vent dust collectors, a copy of which is attached hereto and made a part hereof by reference. s/David J. Kaptain David J. Kaptain, Mayor Presented: March 20, 2019 Adopted: March 20, 2019 Omnibus Vote: Yeas: 8 Nays: 0 Attest: s/Kimberly Dewis Kimberly Dewis, City Clerk PURCHASE AGREEMENT This Agreement is hereby made and entered into this 20th day of March , 2019 by and between the City of Elgin, a municipal corporation (herein referred to as the "City") and Sly Incorporated, an Ohio corporation(herein referred to as"SLY"). NOW THEREFORE, for and in consideration of the mutual promises and covenants contained herein, the sufficiency of which is hereby mutually acknowledged, the parties hereto hereby agree as follows: 1. PURCHASE. City shall purchase and SLY shall sell the goods and services described in Attachment A, said attachment being the proposal for replacement bin vent dust collectors prepared by SLY, consisting of eight (8)pages, dated March 11, 2019, attached hereto and made a part hereof by this reference. 2. TERMS. This agreement shall be subject to the terms and conditions contained herein and as provided by Attachment A. 3. CONFLICT. In the event of any conflict between any of the terms and provisions of this purchase agreement and Attachment A hereto,the terms and provisions of this purchase agreement shall control. 4. LAW/VENUE. This agreement is subject to and governed by the laws of the State of Illinois. Venue for the resolution of any disputes or the enforcement of any rights arising out of or in connection with this agreement shall be the Circuit Court of Kane County, Illinois,without jury. SLY hereby irrevocably consents to the jurisdiction of the Circuit Court of Kane County, Illinois for the enforcement of any rights,the resolution of any disputes and/or for the purposes of any lawsuit brought pursuant to this agreement or the subject matter hereof; and SLY agrees that service by first class U.S. mail to Sly Incorporated, 8300 Dow Circle, Suite 600, Strongsville, Ohio,44136 shall constitute effective service. 5. NO MODIFICATION. There shall be no modification of this agreement, except in writing and executed with the same formalities as the original. 6. MERGER. This agreement embodies the whole agreement of the parties. There are no promises, terms, conditions, or obligations other than those contained herein, and this agreement shall supersede all previous communications,representations,or agreements,either verbal,written or implied between the parties hereto. 7. INTEREST. SLY hereby waives any and all claims or rights to interest on money claimed to be due pursuant to this agreement,and waives any and all such rights to interest to which it may otherwise be entitled, pursuant to law, including, but not limited to, pursuant to the Local Government Prompt Payment Act(50 ILCS 505/1, et seq.)as amended or the Illinois Interest Act (815 ILCS 205/1 et seq.) as amended. The provisions of this paragraph shall survive any expiration,completion, and/or termination of this agreement. 8. SEVERABILITY. The terms of this agreement shall be severable. In the event any of the terms or the provisions of this agreement are deemed to be void or otherwise unenforceable for any reason,the remainder of this agreement shall remain in full force and effect. 9. COMPLIANCE WITH LAW. Notwithstanding any other provision of this agreement it is expressly agreed and understood that in connection with the performance of this agreement, SLY shall comply with all applicable,federal,state,city and other requirements of law,including, but not limited to, any applicable requirements regarding prevailing wages, minimum wage, workplace safety and legal status of employees. Without limiting the foregoing, SLY hereby certifies,represents, and warrants to the City that all of SLY's employees and/or agents who will be providing products and/or services with respect to this agreement shall be legally authorized to work in the United States. SLY shall also at its expense secure all permits and licenses, pay all charges and fees, and give all notices necessary and incident to the due and lawful prosecution of the work,and/or the products and/or services to be provided for in this agreement. The City shall have the right to audit any records in the possession or control of SLY to determine SLY's compliance with the provisions of this section. In the event the City proceeds with such an audit, SLY shall make available to the City, SLY's relevant records at no cost to the City.City shall pay any and all costs associated with any such audit. 10. PAYMENT. City shall pay$89,906.00 to SLY pursuant to Attachment A within thirty (30) days of delivery or City's receipt of invoice, whichever is later. The aforementioned total sum is inclusive of all freight,shipping and applicable taxes,which shall be at SLY's sole expense. 11. DELIVERY. SLY shall complete delivery of all goods on or befo e K 4,2019. 12. LIMITATION OF DAMAGES. In no event shall City be liable for any monetary damages in excess of the purchase price contemplated by this agreement. In no event shall City be liable for any consequential, special, or punitive damages resulting from loss of profit. 13. EXECUTION. This agreement may be executed in counterparts, each of which shall be an original and all of which shall constitute one and the same agreement. For the purposes of executing this agreement,any signed copy of this agreement transmitted by fax machine or e-mail shall be treated in all manners and respects as an original document. The signature of any party on a copy of this agreement transmitted by fax machine or e-mail shall be considered for these purposes as an original signature and shall have the same legal effect as an original signature. Any such faxed or e-mailed copy of this agreement shall be considered to have the same binding legal effect as an original document. At the request of either party any fax or e-mail copy of this agreement shall be re-executed by the parties in an original form. No party to this agreement shall raise the use of fax machine or e-mail as a defense to this agreement and shall forever waive such defense. 14. TRANSFER OF TITLE/RISK. Transfer of title and risk of loss shall pass to the City upon delivery of the goods. All transportation and delivery shall be at SLY's sole expense. 15. INDEMNIFICATION. To the fullest extent permitted by law, SLY agrees to and shall indemnify, defend and hold harmless the City, its officers, employees, boards and commissions from and against any and all claims, suits,judgments,costs, attorney's fees, damages or any and all other relief or liability arising out of or resulting from or through or alleged to arise out of any acts or negligent acts or omissions of SLY or SLY's officers,employees,agents or subcontractors in the performance of this agreement, including but not limited to,all goods delivered or services or work performed hereunder. In the event of any action against the City,its officers,employees, agents, boards or commissions covered by the foregoing duty to indemnify, defend and hold harmless, such action shall be defended by legal counsel of the City's choosing. 16. AUTHORITY. The person signing this Agreement on behalf of SLY represents and warrants that s/he has the authority to commit SLY to this Agreement, and has been authorized to execute this Agreement on its behalf. IN WITNESS WHEREOF, the City of Elgin and SLY Incorporated have caused this contract to be executed by their duly authorized representatives this 20th day of March ,2019 SLY INCORPORATED CITY OF ELGIN David Mosinski //`logKediK, l P*.if Richard G.Kozal, City Manager Signa Atte he/04(46 Regional Sales Manager City Cl- Title 3 ATTACHMENT A Proposal for Replacement Bin Vent Dust Collectors by SLY Inc., Consisting of Eight (8) Pages, Dated March 11, 2019 B91 Quotation Number R conal Manager FOB — _ 6314-r4 CHI(0) Dave Mosinski Shipping Point IMC _ ._..._.._..___. 440-274-0381 _mm__, Expiration Sales Representative Payment Terms . .-,.; ,,,,:ahs =>,--:-.;nw -— ._..... TECHNOLOGY FOR A April 30,2019 Bill Harding 30/30/40 CLEAN ENVIRONMENT i 630-897-17181 8300 Dow Circle,Suite 600,Strongsville,ON 44136 _ __ www.sinc.com March 11,2019 Ms.Nora Bertram CITY OF ELGIN Water Department 150 Dexter Court Elgin, IL 60120 Ph: 847-544-1193 Email: bertram_n@cityofelgin.org Subject: Replacement Bin Vent Dust Collectors Nora, Please accept this as our formal proposal for replacement dust collection equipment at your facility. We've included this initial summary below with details on the following pages. Equipment/Proposal Summary: (Qty: 1)Carbon Powder Dust Collector(SBR-55-4), $23,634.00 Exhaust Fan(Cincinnati PB-14A),$3,940.00 304L SS construction, $5,909.00 Filter/Regulator(Wilkerson R30),$750.00 Rotary Airlock(Meyer 8 x 8 HDX), $4,579.00 Total: $38,812.00 (Qty:2)Lime&Soda Ash Bin Vents(SBR-55-4BV),$14,022.00 Exhaust Fan(Cincinnati PB-14A), $3,940.00 304L SS construction, $4,935.00 Filter/Regulator(Wilkerson R30), $750.00 $23,647.00 each,Total:$47,294.00 Estimated Freight to Jobsite: $3,800.00 Proposed order total including(1)carbon dust collector,(2)bin vents and freight: $89,906.00 Equipment/Proposal Details: CARBON POWDER DUST COLLECTOR WITH SUPPORT LE S We understand the proposed equipment is to operate under the following conditions: Application: Silo Ventilation Material Collected: Carbon Powder Location: Outdoors Air Volume: 1,200 ACFM Bulk Density: 38 PCF(assumed) Particle Size: Unknown Temperature: 70 deg. F Inlet Loading: Unknown Design Pressure: +80"/-20"w.g. Sly Quote#6314r4-CHI(0) -2- THE ABOVE MATERIAL IS CLASSIFIED BY NFPA AS A COMBUSTIBLE DUST (Kst=113, Pmax=8.6 assumed) WHEN PARTICLE SIZES ARE 500 MICRON OR SMALLER. SLY RECOMMENDS EXPLOSIVITY TESTING PER ASTM E1226 "STANDARD TEST METHOD FOR EXPLOSIBILITY OF DUST CLOUDS" OF THE PRODUCT BE PERFORMED BY AN INDEPENDENT THIRD PARTY FOR VERIFICATION. SLY RESERVES THE RIGHT TO TURN BACK AN ORDER BASED ON THIS PROPOSAL UNLESS VERIFICATION THAT THIS TESTING HAS BEEN COMPLETED IS PROVIDED.SHOULD THE DUST TEST POSITIVE,SLY RESERVES THE RIGHT TO MODIFY THE PROPOSAL TO BE IN COMPLIANCE. OSHA REGULATES FACILITIES REGARDING COMBUSTIBLE DUSTS AND THE END USER IS ULTIMATELY RESPONSIBLE FOR THE SAFETY OF THE INSTALLATION.SEE SLY'S PRODUCT DISCLAIMER AS INCLUDED IN THE ATTACHED TERMS AND CONDITIONS. Sly recommends the following equipment selection: Model: SBR-55-4 Air/Cloth Ratio: 1.7: 1 Filter Area: 705 sq.ft. No. of bags/diameter: 25/5-3/4" Interstitial Velocity: 182 FPM Bag Length: 41.38" Filter Media: 8 oz.spun-bonded Type of Bags: Pleated with molded polyester wide spacing urethane top/bottom Special bag Stainless steel construction: grounded scrim The approximate dimensions of this model are: Length: 3'-4"(inside dimension) Width: 3'-4"(inside dimension) Height: 12'-7"(including support) The compressed air requirement for this model is 5 SCFM @ 70-80 psig. The dust collector will be fabricated as follows: Clean air plenum 12 gauge Carbon steel Pulse pipes Schedule 40 Carbon steel Tubesheet 10 gauge Carbon steel Dusty air plenum 12 gauge Carbon steel Hopper 12 gauge Carbon steel Stiffeners Structural channel Carbon steel The equipment will be prepared and painted as follows: -Collector internal surfaces to be treated with SSPC-SP3 preparation and one prime coat of Mobile Silicone Alkyd, 1-2 mils DFT. Color: Gray. -Collector external surfaces to be treated with SSPC-SP6 preparation, one prime coat of Mobile MoPoxy epoxy primer, 1-2 mils OFT and two coats of Mobile MoPoxy epoxy finish, 2-4 mils OFT. Color: Blue. - Supports to be treated with SSPC-SP6 preparation,one prime coat of Mobile MoPoxy epoxy primer, 1-2 mils DFT and two coats of Mobile MoPoxy epoxy finish,2-4 mils DFT. Color: Blue. -Access platform to be treated with SSPC-SP3 preparation,one prime coat of Mobile Armor Tech Alkyd, 1-2 mils DFT and one coat Mobile Acrylic Enamel, 1-2 mils DFT. Handrails and ladder Color: Safety Yellow.Grating: Black The following features are included: Sly Quote#6314-r4-CHI(0) -3- -All welded filter housing with external grounding lugs provided across flanged and gasketed housing connections with interconnecting cables. It is recommended that customer also ground any additional auxiliary equipment and incorporate an interlock to stop the flow of compressed air to the header. Explosion Vent - (1)24"diameter explosion relief vent of 304 SS construction with silicone seal. Price includes reinforced filter housing and vent mounting frames. Pred design is based on two-thirds of the ultimate strength of the metal per NFPA-68-2018, 6.3.1.1. Vent is sized in accordance with NFPA-68-2018 with Pstat= 0.1 bar, Kst=113 and Pmax=8.6 bar, as provided.The vent is shipped loose to prevent damage in transit. - A burst indicator is included. -(1)Hinged and gasketed weather tight housing door is provided for quick access for filter bag inspection&removal. -Tube sheet is provided with bolted,gasketed and galvanized venturis and mounting hub with stainless steel clamps for securely attaching bags. -60 degree all welded pyramidal hopper complete with: -Flanged and baffled diffuser inlet. -8"x 8"product discharge flange to mate with airlock. -Access port with neoprene gasket. -Factory installed compressed air header assembly/pulse cleaning system: -Compressed air manifold of carbon steel,schedule 40 pipe. -Goyen solenoid valves in NEMA-4 enclosure. -Impolene Tubing. -Goyen Diaphragm valves. -Bag cleaning control includes Sly Model MP-404 solid-state timer(1/60/120 VAC)in a NEMA 4 enclosure with pressure module for on demand or for continuous adjustable timed sequential control of the pulse-cleaning operation. Control panel is factory mounted to the collector and wired to the solenoid valves. -(2)1/8"NPT couplings for differential pressure connection. -Differential pressure gauge,complete with bracket,fittings and 20 ft.of Impolene tubing provided, shipped loose for field installation. -Fabrication to Sly standard manufacturing practice includes continuous welds on the exterior and stitch welds on the interior.Weld spatter is removed. -The collector is shop assembled including the pulse cleaning system. Bags are shipped loose. 1 - Structural support designed for 115 MPH wind load(per ASCE 7-10), constructed of carbon steel to allow 5 feet clearance below hopper discharge flange. 1 - Access walkway to the filter housing access door with standard access ladder&safety chain. Price, F.O.B.,Shipping Point $23,634.00 Cincinnati Fan Size PB-14A,Arrangement No.4HM direct drive horizontal mount. Sly Quote#6314-r4-CHI(0) -4- Fan to handle: 1,200 ACFM at an estimated 8"static pressure,3500 RPM, 3.67 BHP at 70 deg. F. Accessories included: Flanged inlet Manual outlet damper Weather hood &bird screen AMCA"C"spark-proof construction 5 HP, 1800 rpm, TEFC wash-down premium efficiency motor for 3/60/230-460 volts Price, F.O.B.,Shipping Point $3,940.00 Optional 304L stainless steel construction in lieu of carbon steel and epoxy coated. Add, F.O.B.,Shipping Point $5,909.00 Optional filter/regulator/gauge for compressed air supply. Consists of Wilkerson R30 compressed air regulator and F-30 filter,with Ashcroft 1009, 0-160 psig gauge. Components are shipped loose with Sly equipment for field assembly and installation. Add, F.O.B.Shipping Point $750.00 Rotary Valve - Meyer 8 x 8 HDX, cast iron rotary valve with a 3/4 HP,TEFC motor and 15 RPM chain drive package for 3/60/230/460 VAC operation. Includes 8-vane rotor with beveled edges and finger guard. Construction to comply with NFPA-69-2014, 12.2.4 for deflagration isolation only. For deflagration isolation per NFPA-69-2014, 12.2.4.5,the rotary valve will be supplied with 8- vane beveled edge rotors with initial nominal clearances of 0.005"and not to exceed 0.006" measured from rotor tip to housing bore and rotor end to headplate. Per NFPA-69-2014, 12.2.4.5.3,these clearances must be maintained so as not to exceed 0.0079"(0.2 mm). This minimum clearance must be maintained by the end user. Since all rotary valves are subject to internal wear,it is recommended that the clearances of the rotary valve be checked periodically by the end user and corrective measures be taken before wear results in these minimum acceptable clearances being exceeded. Per NFPA-69,an interlock will be required to stop the rotary valve in the event of a fire or deflagration to prevent discharge of burning material into the bin or drum below the rotary valve. This instrumentation is by others. Add, F.O.B. Shipping Point $4,579.00 TOTAL FOR ABOVE $38,812.00 Estimated shipping weight $2,500 pounds LIME&§ODA ASIj,BIN VENT FILTERS We understand the proposed equipment is to operate under the following conditions: Application: Bin Vent Material Collected: Lime or Soda Ash Sly Quote#6314-r4-CHI(0) -5- Location: Outdoors Air Volume: 1,200 ACFM Bulk Density: Various Particle Size: Unknown Temperature: 70 deg. F Inlet Loading: Unknown Design Pressure: +/-20"w.g. Sly recommends the following equipment selection: Model: SBR-55-4 BV Air/Cloth Ratio: 1.7: 1 Filter Area: 705 sq.ft. No.of bags/diameter: 25/5-3/4" Interstitial Velocity: 182 FPM Bag Length: 41.38" Filter Media: 8 oz.spun-bonded Type of Bags: Pleated with molded polyester wide spacing urethane top/bottom The approximate dimensions of this model are: Length: 40"(inside dimension) Width: 40"(inside dimension) The compressed air requirement for this model is 5 SCFM @ 70-80 psig. The dust collector will be fabricated as follows: Clean air plenum 12 gauge Carbon steel Pulse pipes Schedule 40 Carbon steel Tubesheet 10 gauge Carbon steel Dusty air plenum 12 gauge Carbon steel Stiffeners Structural channel Carbon steel The equipment will be prepared and painted as follows: -Collector internal surfaces to be treated with SSPC-SP3 preparation and one prime coat of Mobile Silicone Alkyd, 1-2 mils DFT. Color: Gray. -Collector external surfaces to be treated with SSPC-SP6 preparation, one prime coat of Mobile MoPoxy epoxy primer, 1-2 mils DFT and two coats of Mobile MoPoxy epoxy finish,2-4 mils DFT.Color:Blue. The following features are included: -All welded filter housing. - Hinged and gasketed weather tight housing door is provided for quick access for filter bag inspection& removal. -Tube sheet is provided with bolted,gasketed and galvanized venturis and mounting hub with stainless steel clamps for securely attaching bags. -Factory installed compressed air header assembly/pulse cleaning system: -Compressed air manifold of carbon steel, schedule 40 pipe. -Goyen solenoid valves in NEMA-4 enclosure. -Impolene Tubing. -Goyen Diaphragm valves. Sly Quote#6314-r4-CHI(0) -6- -Bag cleaning control includes Sly Model MP-404 solid-state timer(1/60/120 VAC)in a NEMA 4 enclosure with pressure module for on demand or for continuous adjustable timed sequential control of the pulse-cleaning operation. Control panel is factory mounted to the collector and wired to the solenoid valves. -Full internal safety grid with transition to existing silo flange pattern. -(2) 1/8"NPT couplings for differential pressure connection. -Differential pressure gauge,complete with bracket,fittings and 20 ft. of Impolene tubing provided, shipped loose for field installation. -Fabrication to Sly standard manufacturing practice includes continuous welds on the exterior and stitch welds on the interior.Weld spatter is removed. -The collector is shop assembled including the pulse cleaning system. Bags are shipped loose. Price, F.O.B.Shipping Point $14,022.00 each Estimated shipping weight 988 pounds each Cincinnati Fan Size PB-14A,Arrangement No. 4HM direct drive horizontal mount Fan to handle: 1,200 ACFM at an estimated 8"static pressure, 3500 RPM, 3.67 BHP at 70 deg. F. Accessories included: Flanged inlet Manual outlet damper Weather hood&bird screen AMCA"C"spark-proof construction 5 HP, 1800 rpm,TEFC wash-down premium efficiency motor for 3/60/230-460 volts Price, F.O.B.Shipping Point $3,940.00 each Optional 304L stainless steel construction in lieu of carbon steel and epoxy coated. Add, F.O.B.Shipping Point $4,935.00 Optional filter/regulator 1 gauge for compressed air supply. Consists of Wilkerson R30 compressed air regulator and F-30 filter,with Ashcroft 1009, 0-160 psig gauge.Components are shipped loose with Sly equipment for field assembly and installation. Add, F.O.B. Shipping Point $750.00 TOTAL FOR ABOVE(TWO BIN VENT FILTERS) $47,294.00 Freight for above to City of Elgin, IL 60120 $3,800.00 Estimated TOTAL FOR ALL EQUIPMENT SHIPPED TO JOBSITE TOTAL ORDER $89,9006.00 Sly Quote#6314r4-CHI(0) -7- Dust Collector Installations with Combustible Particulate Solids or Explosion Hazards Process and ventilation systems which handle combustible particulate solids and / or gases shall be designed by and installed under the supervision of qualified engineers who are knowledgeable about these systems and their associated hazards. OSHA regulates facilities regarding combustible dusts and the end user is ultimately responsible for the safety of the installation. Sly's equipment is one component of the total dust control system. In some instances Sly may recommend explosion protection or protective equipment. However, it is the ultimate responsibility of the customer to adhere to the applicable ATEX, NFPA and OSHA standards and Sly cannot assume any liability for the system design. See our"Product Disclaimer" in the attached terms and conditions. It is the responsibility of our customers to ensure the safety of equipment and personnel around the proposed equipment and to ensure the proper design and installation of the ventilation and material handling systems, including electrical integration per NFPA Standards/Guidelines. Sly is offering explosion protection with its products as devices to safeguard our equipment. Inasmuch as possible, we follow the applicable codes, guidelines, and standards in regard to the design of the dust collection equipment Sly provides. Sly cannot assume liability for the fitness of such devices on a system- wide basis at a given plant location after installation by others. TEMPERATURE AND MOISTURE PARAMETERS: Paint: Interior paint has maximum operating temperature of 400 deg. F. Exterior paint has a maximum operating temperature of 250 deg. F. Gaskets: Gaskets have a maximum operating temperature of 175 deg. F. Filter Media: Filter media has a maximum operating temperature of 275 deg. F. This equipment must be operated at a temperature above the dew point at all times and below the maximum operating temperatures outlined above. In some elevated temperature processes or high humidity applications,the use of insulation, auxiliary heat, and special operating and start-up and shut- down procedures may be required. VALIDITY: The prices contained herein are valid for a period of 30 days, after which we reserve the right to review our quote. ORDERS: Purchase orders should be addressed to Sly Incorporated,8300 Dow Circle, Suite 600, Strongsville,Ohio 44136.Written purchase orders must be received and accepted by Sly before engineering commences. TERMS: 30%with order NET 10 days. 30%with submittal of engineering approvals(NET 30 or before shipment,whichever occurs first). 40% NET 30 DAYS. Prices are firm for acceptance in 30 days and shipment as noted below. An order placed on any or all the above equipment/services is subject to attached "Terms and Conditions". Any additional terms or conditions contained in Buyers Request for Quote or Purchase Order shall be deemed of no consequence to the contract and shall not be binding upon Seller unless agreed to in writing by the Sly Quote#6314r4-CHI(0) -8- Seller. Acknowledgment of Buyer's Purchase Order by Seller will not constitute acceptance of Buyer's Terms and Conditions regardless of statements to the contrary. Terms are subject to credit approval at time of order. Note: A fee of 5%of the invoice value will be administered to all payments made with credit cards. FREIGHT: See above. SHIPMENT: Approval drawings are typically submitted 3 to 4 weeks after date of order acknowledgment. Submittal of approval drawings will be confirmed based on Sly's engineering schedule at time of order. Drawings will be provided in AutoCAD and PDF format. If an alternate format is required please advise immediately to avoid additional charges and/or delays. Shipment is typically 7 to 8 weeks after receipt of signed approval drawings. Final shipment will be confirmed based on Sly's shop schedule at time signed approval drawings are received. Sly may be able to offer expedited delivery upon request; please contact us with your requirements. NOTE: ABOVE SUBJECT TO VERIFICATION AT TIME OF ORDER. If you have any questions regarding this quotation or have any further requirements, please contact me direct at 440-274-0381 or our local representative, Bill Harding at: Indutrial Sales Midwest. Inc. Ph: 630-897-1718 wbharding@sbcglobal.net 419 Harmony Drive North Aurora, IL 60542-1513